Operating Instructions Radar sensor for continuous level measurement VEGAPULS 31 Two-wire 4 ... 20 mA/HART Document ID: 57820 2 Contents VEGAPULS 31 • Two-wire 4 ... 20 mA/HART 57820-EN-191014 Contents 1 About this document ...............................................................................................................4 1.1 Function ...........................................................................................................................4 1.2 Target group .....................................................................................................................4 1.3 Symbols used...................................................................................................................4 2 For your safety .........................................................................................................................5 2.1 Authorised personnel .......................................................................................................5 2.2 Appropriate use ................................................................................................................5 2.3 Warning about incorrect use .............................................................................................5 2.4 General safety instructions ...............................................................................................5 2.5 EU conformity ...................................................................................................................6 2.6 Installation and operation in the USA and Canada ...........................................................6 2.7 Safety instructions for Ex areas ........................................................................................6 3 Product description .................................................................................................................7 3.1 Configuration ....................................................................................................................7 3.2 Principle of operation........................................................................................................9 3.3 Adjustment .......................................................................................................................9 3.4 Packaging, transport and storage ...................................................................................10 3.5 Accessories....................................................................................................................11 4 Mounting .................................................................................................................................12 4.1 General instructions .......................................................................................................12 4.2 Mounting instructions .....................................................................................................13 4.3 Measurement setup - Flow .............................................................................................16 5 Connecting to power supply .................................................................................................19 5.1 Preparing the connection ...............................................................................................19 5.2 Connecting .....................................................................................................................20 5.3 Wiring plan .....................................................................................................................21 5.4 Switch-on phase.............................................................................................................22 6 Access protection ..................................................................................................................23 6.1 Bluetooth radio interface ................................................................................................23 6.2 Protection of the parameterization ..................................................................................23 7 Set up with the integrated display and adjustment unit ....................................................25 7.1 Adjustment system .........................................................................................................25 7.2 Measured value and menu item display .........................................................................26 7.3 Menu overview ...............................................................................................................27 7.4 Parameter adjustment ....................................................................................................28 8 Setup with smartphone/tablet (Bluetooth) ..........................................................................36 8.1 Preparations ...................................................................................................................36 8.2 Connecting .....................................................................................................................36 8.3 Parameter adjustment ....................................................................................................37 9 Setup with PC/notebook (Bluetooth) ...................................................................................38 9.1 Preparations ...................................................................................................................38 9.2 Connecting .....................................................................................................................38 9.3 Parameter adjustment ....................................................................................................39 10 Setup with PC/notebook (VEGACONNECT) ........................................................................40 3 Contents VEGAPULS 31 • Two-wire 4 ... 20 mA/HART 57820-EN-191014 10.1…
Text truncated - open the document above for the full version.
Operating Instructions Radar sensor for continuous level measurement VEGAPULS 11 Two-wire 4 ... 20 mA Document ID: 58350 2 Contents VEGAPULS 11 • Two-wire 4 ... 20 mA 58350-EN-191014 Contents 1 About this document ...............................................................................................................4 1.1 Function ...........................................................................................................................4 1.2 Target group .....................................................................................................................4 1.3 Symbols used...................................................................................................................4 2 For your safety .........................................................................................................................5 2.1 Authorised personnel .......................................................................................................5 2.2 Appropriate use ................................................................................................................5 2.3 Warning about incorrect use .............................................................................................5 2.4 General safety instructions ...............................................................................................5 2.5 EU conformity ...................................................................................................................6 2.6 Installation and operation in the USA and Canada ...........................................................6 2.7 Safety instructions for Ex areas ........................................................................................6 3 Product description .................................................................................................................7 3.1 Configuration ....................................................................................................................7 3.2 Principle of operation........................................................................................................8 3.3 Adjustment .......................................................................................................................8 3.4 Packaging, transport and storage .....................................................................................9 3.5 Accessories....................................................................................................................10 4 Mounting .................................................................................................................................11 4.1 General instructions .......................................................................................................11 4.2 Mounting instructions .....................................................................................................12 4.3 Measurement setup - Flow .............................................................................................15 5 Connecting to power supply .................................................................................................18 5.1 Preparing the connection ...............................................................................................18 5.2 Connecting .....................................................................................................................19 5.3 Wiring plan .....................................................................................................................20 5.4 Switch-on phase.............................................................................................................21 6 Access protection ..................................................................................................................22 6.1 Bluetooth radio interface ................................................................................................22 6.2 Protection of the parameterization ..................................................................................22 7 Setup with smartphone/tablet (Bluetooth) ..........................................................................24 7.1 Preparations ...................................................................................................................24 7.2 Connecting .....................................................................................................................24 7.3 Parameter adjustment ....................................................................................................25 8 Setup with PC/notebook (Bluetooth) ...................................................................................26 8.1 Preparations ...................................................................................................................26 8.2 Connecting .....................................................................................................................26 8.3 Parameter adjustment ....................................................................................................27 9 Menu overview .......................................................................................................................28 10 Diagnostics and servicing ....................................................................................................30 10.1 Maintenance ..................................................................................................................30 10.2 Rectify faults ...................................................................................................................30 10.3 Diagnosis, fault messages .............................................................................................31 10.4 Status messages according to NE 107 ..........................................................................31 3 Contents VEGAPULS 11 • Tw…
Text truncated - open the document above for the full version.
Operating Instructions Radar sensor for continuous level measurement of liquids VEGAPULS 21 Two-wire 4 ... 20 mA/HART Document ID: 58351 2 Contents VEGAPULS 21 • Two-wire 4 ... 20 mA/HART 58351-EN-191014 Contents 1 About this document ...............................................................................................................4 1.1 Function ...........................................................................................................................4 1.2 Target group .....................................................................................................................4 1.3 Symbols used...................................................................................................................4 2 For your safety .........................................................................................................................5 2.1 Authorised personnel .......................................................................................................5 2.2 Appropriate use ................................................................................................................5 2.3 Warning about incorrect use .............................................................................................5 2.4 General safety instructions ...............................................................................................5 2.5 EU conformity ...................................................................................................................6 2.6 Installation and operation in the USA and Canada ...........................................................6 2.7 Safety instructions for Ex areas ........................................................................................6 3 Product description .................................................................................................................7 3.1 Configuration ....................................................................................................................7 3.2 Principle of operation........................................................................................................8 3.3 Adjustment .......................................................................................................................8 3.4 Packaging, transport and storage .....................................................................................9 3.5 Accessories....................................................................................................................10 4 Mounting .................................................................................................................................11 4.1 General instructions .......................................................................................................11 4.2 Mounting instructions .....................................................................................................12 4.3 Measurement setup - Flow .............................................................................................15 5 Connecting to power supply .................................................................................................18 5.1 Preparing the connection ...............................................................................................18 5.2 Connecting .....................................................................................................................19 5.3 Wiring plan .....................................................................................................................20 5.4 Switch-on phase.............................................................................................................21 6 Access protection ..................................................................................................................22 6.1 Bluetooth radio interface ................................................................................................22 6.2 Protection of the parameterization ..................................................................................22 7 Setup with smartphone/tablet (Bluetooth) ..........................................................................24 7.1 Preparations ...................................................................................................................24 7.2 Connecting .....................................................................................................................24 7.3 Parameter adjustment ....................................................................................................25 8 Setup with PC/notebook (Bluetooth) ...................................................................................26 8.1 Preparations ...................................................................................................................26 8.2 Connecting .....................................................................................................................26 8.3 Parameter adjustment ....................................................................................................27 9 Setup with PC/notebook (VEGACONNECT) ........................................................................28 9.1 Connect the PC ..............................................................................................................28 9.2 Parameter adjustment with PACTware ............................................................................29 9.3 Saving the parameterisation data ...................................................................................30 10 Menu overview .......................................................................................................................31 3 Contents VEGAPULS 21 • Two-wire 4 ... 20 mA/HART 58351-EN-191014 11 Diagnostics and servicing .......................................................................…
Text truncated - open the document above for the full version.
VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach VEGAPULS 11 VEGAPULS 21 VEGAPULS 31 1 European Union Hereby, VEGA Grieshaber KG declares that the radio equipment type VEGAPULS 11, VEGAPULS 21, VEGAPULS 31 are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.vega.com 2 USA FCC ID O6QBRA300 FCC § 15.19 Labelling requirements This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC § 15.21 Information to user "Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment." FCC §15.105 statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF Exposure Requirements To comply with FCC RF exposure compliance requirements, the device must be installed to provide a separation distance of at least 20 cm from all persons. 3 Canada IC: 3892A-BRA300 This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Canada Class B statement This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. RF Exposure Requirements This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Déclaration d’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. 4 Australia 5 Belarus 6 Brazil Atendimento à Regulamentação Anatel Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL www.anatel.gov.br 8 China 9 CU declaration 10 Hong Kong 11 India ETA: XXX/20XX/XXXX 12 Indonesia [certificate no.] [PLG. ID no.] 13 Israel 14 Japan 15 Malaysia 16 Mexico IFT: XXXXXXXXXX La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. 17 New Zealand R-NZ 18 Philippines 19 Russia Registration Nr. XX-XXXX HHHHH-AA-FFFFF XXXXX-XX ZZZZ VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach 20 Serbia 21 Singapore Complies with IMDA Standards [Dealer's License No.] 22 South Africa TA-YEAR/XXXX 23 South Korea R-C/R-ABC-XXXXXXXXXXX 해당 무선 설비는 운용 중 전파혼신 가능성이 있음. This wireless device has possibility to electric wave interference in operation. 24 Taiwan XXXXZZXXZZZZXZ 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電 機,非經許可,公司、商號或使用者均不得擅 自變更頻率、加大功率或變更原設計之特性及 功能。第十四條 低功率射頻電機之使用不 得影響飛航安全及干擾合法通信;經發現有干 擾現象時,應立即停用,並改善至無干擾時方 得繼續使用。 前項合法通信,指依電信法規定作業之無線電 通信。 25 Ukraine VEGA Grieshaber KG заявляет, что это тип радиоустройства: Радарный датчик для измерения уровня. Модель: VEGAPULS 11, VEGAPULS 21, VEGAPULS 31, соответствует Техническим Правилам радиосвязи, пожалуйста, обратите внимание на декларацию о доступности на сайте и одновременно на адрес VEGA Grieshaber KG: https:www.VEGA.com 26 Vietnam
FCC, Request for non-disclosureDate:21-Nov-2018 RF_501, Issue8Page 1 of 1 Company Name:VEGA Grieshaber KG Address:Am Hohenstein 113 City:77761 Schiltach Country:Germany To:Telefication B.V.,Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject:Request for confidentiality FCC ID:O6QBRA300 Reference number:###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuantto 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of MaterialBlock Diagrams Operational DescriptionSchematic DiagramsTune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitiveharm and provide unjustifiedbenefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant toPublic Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rulesin 47 CFR §2.1204, applicanthereby requests Short-Term Confidential treatment of the following materials (Seenotesbelow): Internal PhotosUser’s ManualTest Set-up PhotosExternal Photos Justification:These documents contain detailed system and equipment description and related information. This information should never get into the possession of competitors, which would be harmful for our business. Date:05/05/2020Name and signature of applicant:Melanie Anastassiou Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180days max.)! Theplanneddate shouldstated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration ofthe STC period
External Photos VEGAPULS 11und 21: VEGAPULS31:
VEGAPULS 11 VEGAPULS 11 s/n 12345678 FCC - ID : O6QBR A300, IC : 3892A - BR A300 12...30V 4...20mA HART 2020 www.vega.co m Made in Germany D - 77761 Schil tach 15m IP66/67, Type 4x Tag - Name PVDF MWP 3bar/300kPa IP/Type ra ti ng on ly wi th tigh tl y clo sed cove r 123456 Location for FCC/IC Location for FCC/IC VEGAPULS 21, VEGAPULS 31 0044 VEGAPULS 21 s/n 12345678 PTB 19 ATEX 1234X II 1G, 1/2G, 2G E x i a IIC T4 Ga, Ga/ Gb, Gb IE CEx P TB 19.0001234X II 1G, 1/2G, 2G Ex ia II C T4 Ga, Ga/Gb, Gb C SA 19.12345678 (I S) CL I D IV 1 GP A BC D; CL I I DIV 1 GP EFG, Txx °C. .. yy° C; C l I , Zn0,0/1 A /Ex ia I IC T4 Ga, Ga/Gb FM (IS ) CL I D IV 1 GP A BCD ; CL I I D IV 1 GP EFG, Tx x° C. ..y y° C; Ins tall per Drawing 123456 FC C - ID: O6QBRA300, IC: 3892A - BR A300 12...30V 4...20mA HART 2020 www.vega.co m Made in Germany D - 77761 Schil tach 15m IP66/67, Type 4x Tag - Name PVDF MWP 3bar/300kPa 123456 Location for FCC/IC Location for FCC/IC Location for FCC/IC
InternalPhotos VEGAPULSxx series:
Test Laboratory: 7layersGmbH Borsigstraße 11 40880 Ratingen Germany Note: The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts without the written approval of the test laboratory. 7layers GmbHRegistergerichtregistered in: Borsigstraße 11Geschäftsführer /Düsseldorf, HRB 75554 40880 Ratingen, GermanyManaging Directors:USt-IdNrVAT No.: T +49 (0) 2102 749 0Frank SpillerDE203159652 F +49 (0) 2102 749 350Bernhard RetkaTAX No.147/5869/0385 www.7layers.comAlexandre Norré-OudardABureau Veritas Group Company RF Exposureand Maximum ERP/EIRPAssessment For VEGAPULS 11, 21, 31 FCC ID:O6QBRA300 IC:3892A-BRA300 Assessment Reference:MDE_VEGA_1902_MPE_03 Assessment Reference: MDE_VEGA_1902_MPE_03Page2of6 Table of Contents 0Summary3 Technical Report Summary3 1Administrative Data4 Laboratory4 Project Data4 Applicant Data4 Manufacturer Data4 2Test object Data5 General EUE Description5 EUT Main components5 Ancillary Equipment5 Auxiliary Equipment5 3Evaluation Results6 RF Exposure Evaluation6 Assessment Reference: MDE_VEGA_1902_MPE_03Page3of6 0Summary Technical Report Summary Type ofReport RF Exposure and Maximum ERP/EIRP Assessment forRadar sensorswithRadar and Bluetooth Low Energy. ApplicableFCCandISEDRules For RF Exposure: OET Bulletin 65 Edition 97-01 August 1997 FCC 47 CFR §1.1307 FCC 47 CFR §1.1310 RSS-102 Issue 5–March 2015 ForMaximum ERP/EIRP: FCC 47 CFR §15.247 FCC 47 CFR §15.256 IC RSS-247, Issue2 IC RSS-211, Issue1 Report version control Rev Version Release dateChanges Version validity -02.04.2020Initial versionInvalid 104.05.2020Corrected EIRP value forRadarInvalid 206.05.2020 Maximum radiated value for Radar changed Valid Assessment Reference: MDE_VEGA_1902_MPE_03Page4of6 1Administrative Data Laboratory Company Name:7layersGmbH AddressBorsigstr. 11 40880 Ratingen Germany FCC accreditationDesignation Number: DE0015 TestFirm Registration #: 929146 Industry Canada Test Site AcceptanceCAB identifier: DE0007 Test Firm Registration #: 3699A The test facility is also accredited by the following accreditation organisation: Laboratory accreditation no.:DAkkSD-PL-12140-01-01 DAkkS D-PL-12140-01-02 DAkkS D-PL-12140-01-03 Responsible for Accreditation Scope:Dipl.-Ing. Bernhard Retka Dipl.-Ing. Robert Machulec Dipl.-Ing. Andreas Petz Dipl.-Ing. Marco Kullik Report Template Version:2020-02-19 Project Data Responsible forassessmentand report:Mrs. Melanie Anastassiou Date of Report:2020-05-06 Applicant Data Company Name:VEGA Grieshaber KG Address:Am Hohenstein 113 77761 Schiltach Germany Contact Person:Mr.PatrickFriedmann Manufacturer Data Company Name:please see applicant data Address: Contact Person: Assessment Reference: MDE_VEGA_1902_MPE_03Page5of6 2Test object Data General EUEDescription Equipment underEvaluationVEGAPULS 11, 21, 31 Type Designation:VEGAPULS Kind of Device:Radar sensors General product description: Radar sensors for continues level measurement of liqiudswith Bluetooth Low Energy. EUT Main components Type, S/N, Short Descriptions etc. used in this Test Report ShortDescriptionEquipment under Evaluation Type Designation Serial No.HW StatusSW Status EUEA (BLE)VEGAPULS 21VEGAPULSPULS 21 Bluetooth …
Text truncated - open the document above for the full version.
Am Hohenstein 113 · Schiltach · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15.209 | 77.69 GHz - 82.01 GHz | - |

VEGAMET-Air-841-842
Equipment Class
DTS - Digital Transmission SystemDisplay, adjustment and communication module
Equipment Class
DTS - Digital Transmission System
VEGAMET Air 141 / VEGAMET Air 142
Equipment Class
DTS - Digital Transmission System
VEGAPULS 42 radar sensor for continuous level measurement
Equipment Class
LPR - Level Probing Radar
Radar sensors for continuous level measurement
Equipment Class
DTS - Digital Transmission System