
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 53 of 56 Appendix H: User Manual Please refer to the following pages. OperatingInstructions VEGAPULS68 4...20mA/HARTtwo-wire DocumentID: 36535 Radar Contents 1Aboutthisdocument 1.1Function.................................. 4 1.2Targetgroup.............................. 4 1.3Symbolismused............................ 4 2Foryoursafety 2.1Authorisedpersonnel........................ 5 2.2Appropriateuse............................ 5 2.3Warningaboutmisuse....................... 5 2.4Generalsafetyinstructions.................... 5 2.5CEconformity............................. 6 2.6FulfillmentofNAMURrecommendations.......... 6 2.7RadioapprovalforEurope.................... 6 2.8RadioapprovalforUSA/Canada................ 6 2.9Environmentalinstructions..................... 6 3Productdescription 3.1Configuration.............................. 7 3.2Principleofoperation........................ 8 3.3Packaging,transportandstorage............... 8 3.4Accessoriesandreplacementparts.............. 9 4Mounting 4.1Generalinstructions......................... 11 4.2Mountingpreparations-Hornantenna............ 11 4.3Mountingpreparations-Parabolicantenna......... 12 4.4Mountinginstructions........................ 13 5Connectingtopowersupply 5.1Preparingtheconnection..................... 27 5.2Connection................................ 28 5.3Wiringplan,singlechamberhousing............. 30 5.4Wiringplan,doublechamberhousing............ 30 5.5WiringplanwithdoublechamberhousingExd..... 31 5.6Wiringplan-versionIP66/IP68,1bar........... 32 5.7Switchonphase............................ 32 6Setupwiththeindicatingandadjustmentmodule 6.1Insertindicatingandadjustmentmodule........... 33 6.2Adjustmentsystem.......................... 34 6.3Parameteradjustment........................ 35 6.4Savingtheparameteradjustmentdata............ 43 7SetupwithPACTware 7.1ConnectingthePC.......................... 44 7.2ParameteradjustmentwithPACTware............ 45 7.3Savingtheparameteradjustmentdata............ 46 2VEGAPULS68•4...20mA/HARTtwo-wire Contents 36535 - EN - 100607 8Setupwithothersystems 8.1DDadjustmentprograms..................... 47 8.2Communicator375,475...................... 47 9Diagnosis,faultrectificationandservice 9.1Maintenance.............................. 48 9.2Measuredvalueandeventmemory.............. 48 9.3ErrormessagesaccordingtoNE107............ 49 9.4Rectifymalfunctions......................... 52 9.5Exchangingtheelectronicsmodule.............. 53 9.6Softwareupdate............................ 53 9.7Howtoproceedincaseofrepair................ 54 10Dismounting 10.1Dismountingsteps.......................... 55 10.2Disposal................................. 55 11Supplement 11.1Technicaldata............................. 56 11.2Dimensions............................... 65 SafetyinstructionsforExareas PleasenotetheEx-specificsafetyinformationforinstallationand operationinExareas.Thesesafetyinstructionsarepartofthe operatinginstructionsmanualandcomewiththeEx-approved instruments. VEGAPULS68•4...20mA/HARTtwo-wire3 Contents 36535 - EN - 100607 1Aboutthisdocument 1.1Function Thisoperatinginstructionsmanualprovidesalltheinformationyou needformounting,connectionandsetupaswellasimportant instructionsformaintenanceandfaultrectification.Pleasereadthis informationbeforeputtingtheinstrumentintooperationandkeepthis manualaccessibleintheimmediatevicinityofthedevice. 1.2Targetgroup Thisoperatinginstructionsmanualisdirectedtotrainedqualified personnel.Thecontentsofthismanualshouldbemadeavailableto thesepersonnelandputintopracticebythem. 1.3Symbolismused Information,tip,note Thissymbolindicateshelpfuladditionalinformation. Caution:Ifthiswarningisignored,faultsormalfunctionscan result. Warning:Ifthiswarningisignored,injurytopersonsand/orserious damagetotheinstrumentcanresult. Danger:Ifthiswarningisignored,seriousinjurytopersonsand/or destructionoftheinstrumentcanresult. Exapplications ThissymbolindicatesspecialinstructionsforExapplications. lList Thedotsetinfrontindicatesalistwithnoimpliedsequence. àAction Thisarrowindicatesasingleaction. 1Sequence Numberssetinfrontindicatesuccessivestepsinaprocedure. 4VEGAPULS68•4...20mA/HARTtwo-wire 1Aboutthisdocument 36535 - EN - 100607 2Foryoursafety 2.1Authorisedpersonnel Alloperationsdescribedinthisoperatinginstructionsmanualmustbe carriedoutonlybytrainedspecialistpersonnelauthorisedbytheplant operator. Duringworkonandwiththedevicetherequiredpersonalprotective equipmentmustalwaysbeworn. 2.2Appropriateuse VEGAPULS68isasensorforcontinuouslevelmeasurement. Youcanfinddetailedinformationontheapplicationrangeinchapter "Productdescription". Operationalreliabilityisensuredonlyiftheinstrumentisproperlyused accordingtothespecificationsintheoperatinginstructionsmanualas wellaspossiblesupplementaryinstructions. 2.3Warningaboutmisuse Inappropriateorincorrectuseoftheinstrumentcangiveriseto application-specifichazards,e.g.vesseloverfillordamagetosystem componentsthroughincorrectmountingoradjustment. 2.4Generalsafetyinstructions Thisisastate-of-the-artinstrumentcomplyingwithallprevailing regulationsandguidelines.Theinstrumentmustonlybeoperatedina technicallyflawlessandreliablecondition.Theoperatorisresponsible forthetrouble-freeoperationoftheinstrument. Duringtheentiredurationofuse,theuserisobligedtodeterminethe complianceoftherequiredoccupationalsafetymeasureswiththe currentvalidrulesandregulationsandalsotakenoteofnew regulations. Thesafetyinstructionsinthisoperatinginstructionsmanual,the nationalinstallationstandardsaswellasthevalidsafetyregulations andaccidentpreventionrulesmustbeobservedbytheuser. Forsafetyandwarrantyreasons,anyinvasiveworkonthedevice beyondthatdescribedintheoperatinginstructionsmanualmaybe carriedoutonlybypersonnelauthorisedbythemanufacturer.Arbitrary conversionsormodifica…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 47 of 56 Appendix B: Agency Authorization Letter Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 48 of 56 Appendix C: FCC Confidentiality Request Letter Please refer to the following page.
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Ph: 703-689-0368 Fax: 703-689-2056 External Photograph Report VEGA Grieshaber KG MODELS: VEGAPULS 67 VEGAPULS 68 FCC ID: O6QPS60XS1 Report No: 2009282-6768EP August 12, 2010 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 2 Table of Contents Photograph 1: 245-mm Parabolic Horn Antenna ............................................................................................ 3 Photograph 2: 95-mm Horn Antenna .............................................................................................................. 4 Photograph 3: 75-mm Horn Antenna .............................................................................................................. 5 Photograph 4: 50-mm Horn Antenna .............................................................................................................. 6 Photograph 5: 40-mm Horn Antenna .............................................................................................................. 7 Photograph 6: 80-mm Plastic Horn Antenna .................................................................................................. 8 Photograph 7: 75-mm Metal Antenna ............................................................................................................. 9 Photograph 8: 48-mm Metal Antenna ........................................................................................................... 10 Photograph 9: ½” Stub Antenna ................................................................................................................... 11 Photograph 10: ½” Standpipe Antenna ......................................................................................................... 12 Photograph 11: Antenna Port ....................................................................................................................... 13 Photograph 12: Plastic Housing Front View ................................................................................................. 14 Photograph 13: Plastic Housing inside View ................................................................................................ 15 Photograph 14: Plastic Housing Fitting ......................................................................................................... 16 Photograph 15: Aluminum Housing .............................................................................................................. 17 Photograph 16: Aluminum Housing Front View ............................................................................................ 18 Photograph 17: Double Aluminum Chamber Housing Fitting ....................................................................... 19 Photograph 18: Double Aluminum Housing Fitting Front View ..................................................................... 20 Photograph 19: Double Aluminum Chamber Housing Rear View ................................................................ 21 Photograph 20: Stainless Steel Housing Fitting ........................................................................................... 22 Photograph 21: Stainless Steel Housing Front View .................................................................................... 23 Photograph 22: Stainless Steel Housing Top View ...................................................................................... 24 Photograph 23: LCD Display Top View ........................................................................................................ 25 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 3 Photograph 1: 245-mm Parabolic Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 4 Photograph 2: 95-mm Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 5 Photograph 3: 75-mm Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 6 Photograph 4: 50-mm Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 7 Photograph 5: 40-mm Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 8 Photograph 6: 80-mm Plastic Horn Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 9 Photograph 7: 75-mm Metal Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768EP 10 Photograph 8: 48-mm Metal Antenna Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 He…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 49 of 56 Appendix D: ID Label Please refer to the following page for ID label samples. Photograph 1: ID Label Location
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Ph: 703-689 -0368 Fax: 703-689- 2056 Internal Photograph Report VEGA Grieshaber KG MODELS: VEGAPULS 67 VEGAPULS 68 FCC ID: O6QPS60XS1 Report No: 2009282-6768IP August 25, 2010 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP Table of Contents Photograph 1: Adjustment Board (Component side) ............................................................................... 2 Photograph 2: Adjustment Board (Solder side) ........................................................................................ 2 Photograph 3: Power Supply Board (Component side) ........................................................................... 3 Photograph 4: Power Supply Board (Solder side) ................................................................................... 4 Photograph 5: CPU Board (Component side) .......................................................................................... 5 Photograph 6: CPU Board (Solder side) .................................................................................................. 6 Photograph 7: Frequency Control Board (Component side with shield) .................................................. 6 Photograph 8: Frequency Control Board (Solder side) ............................................................................ 7 Photograph 9: Microwave Board (Component side) ................................................................................ 8 Photograph 10: Microwave Board (SOLDER side) ................................................................................ 8 Photograph 11: Microwave Board (Component side with shield) .......................................................... 9 Photograph 12: Microwave Shield Inside ............................................................................................. 10 Photograph 13: Microwave Shield Outside .......................................................................................... 10 Photograph 14: Electronics Cover (Component side) .......................................................................... 11 Photograph 15: Electronics Cover (Solid side) .................................................................................... 11 Photograph 16: Electronic Kit View 1 ................................................................................................... 12 Photograph 17: Electronic Ki t View 2 ................................................................................................... 12 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 1: ADJUSTMENT BOARD (COMPONENT SIDE) PHOTOGRAPH 2: ADJUSTMENT BOARD (SOLDER SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 3: POWER SUPPLY BOARD (COMPONENT SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 4: POWER SUPPLY BOARD (SOLDER SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 5: CPU BOARD (COMPONENT SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 6: CPU BOARD (SOLDER SIDE) PHOTOGRAPH 7: FREQUENCY CONTROL BOARD (COMPONENT SIDE WITH SHIELD) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 8: FREQUENCY CONTROL BOARD (SOLDER SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 9: MICROWAVE BOARD (COMPONENT SIDE) PHOTOGRAPH 10: MICROWAVE BOARD (SOLDER SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 11: MICROWAVE BOARD (COMPONENT SIDE WITH SHIELD) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 12: MICROWAVE SHIELD INSIDE PHOTOGRAPH 13: MICROWAVE SHIELD OUTSIDE Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 14: ELECTRONICS COVER (COMPONENT SIDE) PHOTOGRAPH 15: ELECTRONICS COVER (SOLID SIDE) Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768IP PHOTOGRAPH 16: ELECTRONIC KIT VIEW 1 PHOTOGRAPH 17: ELECTRONIC K IT VIEW 2
Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 46 of 56 Appendix A: RF Exposure Compliance - §2.1093 Per FCC 1.1310 Table 1B, the maximum permissible RF exposure for an uncontrolled environment is 1 mW/cm 2 for the frequencies used in this device. The worst-case power for each antenna at the center frequency of the band of operation is used for the calculation below. The power density at a 20 cm distance is shown for the antenna used. As shown, the calculated power density is well below the FCC’s limit. The actual power density for the EUT is calculated as shown below. )4/()( 2 dGPS×××=π where: S = power density P = transmitter conducted power in (W) G = antenna numeric gain d = distance to radiation center (m) The EUT power at the input of the antenna is +10 dBm - 25.3 dB = -15.3 dBm or 0.0295 mW. -25.3dB is derived from duty cycle = 10*log (PRF*Pulse width) = 10*log (280 ns*0.6 ns) = -25.3 dB where PRF = 3.56 MHz, and Pulse width = 0.6 ns. Frequency (GHz) Antenna Antenna Max Gain (dBi) Numeric Gain Power (W) Separation Distance (cm) Power Density (mW/cm 2 ) 26 245-mm Parabolic Horn 33.0 302 0.0295 E -3 20 0.02 Note: The 245-mm Parabolic Horn antenna represents the highest antenna gain of all the antennas listed in Table 3-1. Demonstration of compliance to the FCC’s RF Exposure limit using this antenna guarantees that all antennas listed in Table 3-1 meet the FCC’s RF Exposure limit. NOTICE: Radiation Exposure Statement This equipment shall only be installed and operated with the antennas listed in Table 3-1 of this report and shall be installed with a minimum of 20 cm of separation distance between the antenna and all persons during normal operation. Please note that the installation of the EUT in closed tank applications in which tank diameters are always greater than 20 cm satisfy the 20 cm minimum RF exposure distance requirement.
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 F F C C C C P P a a r r t t 1 1 5 5 C C e e r r t t i i f f i i c c a a t t i i o o n n R R e e p p o o r r t t VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany MODELS: VEGAPULS 67 VEGAPULS 68 FCC ID: O6QPS60XS1 August 12, 2010 Frequency Range Output Power (W) Conducted Frequency Tolerance (ppm) Emission Designator 26 GHz 0.01 N/A N/A Report Prepared By: Desmond A. Fraser Document Number: 2009282-6768 I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve compliance with these standards. Furthermore, there was no deviation from, additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15 and ANSI C63.4. Signature: Date: August 12, 2010 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. and VEGA Grieshaber KG. The test results relate only to the item(s) tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445 . Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 2 of 56 Table of Contents 1 General Information ................................................................................................................................. 5 1.1 Test Facility ......................................................................................................................................... 5 1.2 Referenced Standards ........................................................................................................................ 5 2 EUT Configuration, Exercise and Measurement .................................................................................. 6 2.1 Test Equipment Consideration ........................................................................................................... 6 3 Pulse De-sensitizing Factor and Duty Cycle ......................................................................................... 8 3.1 Calculation of Pulse Desensitization Factor ....................................................................................... 8 3.2 Field Strength Calculation .................................................................................................................. 9 3.3 EUT Antenna Data............................................................................................................................ 10 3.4 Test Distance .................................................................................................................................... 10 3.5 Test Set-up ....................................................................................................................................... 11 4 Conducted Emissions - §15.207 ........................................................................................................... 12 4.1 Conducted Limits - §15.207 Test Procedure .................................................................................... 12 4.2 Conducted Emission Limits Test Data.............................................................................................. 12 5 Radiated Emissions - §15.209 .............................................................................................................. 13 5.1 Radiated Emission Limits - §15.209 – Test Procedure .................................................................... 13 5.2 Radiated Emissions Limits Test Data ............................................................................................... 13 6 Restricted Bands - §15.205 ................................................................................................................... 41 6.1 Restricted Band Limits - §15.205 – Test Procedure ......................................................................... 41 7 Bandwidth Measurement - §15.403(c) .................................................................................................. 42 7.1 26 dB Emission Bandwidth Procedure ............................................................................................. 42 7.2 2/ (τ eff ) Bandwidth Calculation .......................................................................................................... 43 8 Test Equipment ...................................................................................................................................... 44 9 Conclusion ............................................................................................................................................. 45 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report Number: 2009282-6768 Page 3 of 56 Table of Tables Table 2-1: Equipment Under Test (EUT) ......................................................................................................................... 6 Table 3-1: EUT Antenna Data ....................................................................................................................................... 10 Table 4-1: Conducted Emissions Limits - Neutral Side (Line 1) .................................................................................... 12 Table 4-2: Conducted Emissions Limits – Hot Side (Line 2) ..........................................................…
Text truncated - open the document above for the full version.
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Ph: 703-689- 0368 Fax: 703-689-2056 Test Configuration Photograph Report VEGA Grieshaber KG Models: VEGAPULS 67 VEGAPULS 68 FCC ID: O6QPS60XS1 Report No: 2009282-6768TP August 12, 2010 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768TP 2 Table of Contents 1 Conducted Emissions 4 Photograph 1: Conducted Emissions EUT View A 4 Photograph 2: Conducted Emissions EUT View B 5 2 Radiated Emissions 6 2.1 Radiated Emissions EUT in Metal Tank 6 Photograph 3: 245mm Horn Antenna Front View Metal Tank 6 Photograph 4: 245mm Horn Antenna Rear View Metal Tank 7 Photograph 5: 95mm Horn Antenna Front View Metal Tank 8 Photograph 6: 95mm Horn Antenna Rear View Metal Tank 9 Photograph 7: 40mm Horn Antenna Front View Metal Tank 10 Photograph 8: 40mm Horn Antenna Rear View Metal Tank 11 Photograph 9: 75mm Metal Antenna Front View Metal Tank 12 Photograph 10: 75mm Metal Antenna Rear View Metal Tank 13 Photograph 11: 48-mm Metal Antenna Front View Metal Tank 14 Photograph 12: 48-mm Metal Antenna Rear View Metal Tank 15 Photograph 13: 80mm Plastic Horn Antenna Front View Metal Tank 16 Photograph 14: 80mm Plastic Horn Antenna Rear View Metal Tank 17 Photograph 15: ½” Stub Antenna Front View Metal Tank 18 Photograph 16: ½” Stub Antenna Rear View Metal Tank 19 Photograph 17: ½” Standpipe Antenna Front View Metal Tank 20 Photograph 18: ½” Standpipe Antenna Front View Metal Tank 21 2.2 Radiated Emissions EUT in Concrete Tank 22 Photograph 19: 245mm Antenna Front View Concrete Tank 22 Photograph 20: 245mm Antenna Rear View Concrete Tank 23 Photograph 21: 95mm Antenna Front View Concrete Tank 24 Photograph 22: 95mm Antenna Rear View Concrete Tank 25 Photograph 23: 40mm Antenna Front View Concrete Tank 26 Photograph 24: 40mm Antenna Rear View Concrete Tank 27 Photograph 25: 75mm Metal Antenna Front View Concrete Tank 28 Photograph 26: 75mm Metal Antenna Rear View Concrete Tank 29 Photograph 27: 48mm Metal Antenna Front View Concrete Tank 30 Photograph 28: 48mm Metal Antenna Rear View Concrete Tank 31 Photograph 29: 80mm Plastic Antenna Front View Concrete Tank 32 Photograph 30: 80mm Plastic Antenna Rear View Concrete Tank 33 Photograph 31: ½” Stub Antenna Front View Concrete Tank 34 Rhein Tech Laboratories, Inc. Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 67 / 68 Suite 1400 FCC ID: O6QPS60XS1 Herndon, VA 20170 Standard: FCC 15.209 http://www.rheintech.com Report No: 2009282-6768TP 3 Photograph 32: ½” Stub Antenna Rear View Concrete Tank 35 Photograph 33: ½” Standpipe Antenna Front View Concrete Tank 36 Photograph 34: ½” Standpipe Antenna Rear View Concrete Tank 37 2.3 Radiated Emissions EUT in Reinforced Fiberglass Tank 38 Photograph 35: 245mm Antenna Front View Fib…
Text truncated - open the document above for the full version.
360 Herndon Parkway Suit 1400 · Herndon · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 26.00 GHz - 26.00 GHz | - |

VEGAMET-Air-841-842
Equipment Class
DTS - Digital Transmission SystemDisplay, adjustment and communication module
Equipment Class
DTS - Digital Transmission System
VEGAMET Air 141 / VEGAMET Air 142
Equipment Class
DTS - Digital Transmission System
VEGAPULS 42 radar sensor for continuous level measurement
Equipment Class
LPR - Level Probing Radar
Radar sensors for continuous level measurement
Equipment Class
DTS - Digital Transmission System