Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 19, 2006
Application Purpose
Original Equipment
Date of Application
Mar 16, 2006
Equipment Note
VEGAPULS 61/62/63 Radar Sensors
Frequency Range
26000.00000000 - 26000.00000000
Company
VEGA Grieshaber KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗
↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

OperatingInstructions VEGAPULS62 4...20mA/HART Contents 1Aboutthisdocument 1.1Function............................. 5 1.2Targetgroup.......................... 5 1.3Symbolismused....................... 5 2Foryoursafety 2.1Authorisedpersonnel.................... 6 2.2Appropriateuse........................ 6 2.3Warningaboutmisuse................... 6 2.4CEconformity......................... 6 2.5Compatibilityacc.toNAMURNE53......... 7 2.6FCC/IC-Conformity(onlyforUSA/Canada).... 7 2.7SafetyinformationforExareas............. 8 2.8Manufacturerdeclaration................. 8 2.9Environmentalinstructions................ 9 3Productdescription 3.1Configuration.......................... 10 3.2Principleofoperation.................... 11 3.3Adjustment........................... 12 3.4Storageandtransport................... 12 4Mounting 4.1Generalinstructions..................... 14 4.2Mountingpreparations-Hornantenna....... 15 4.3Mountingpreparations-Parabolicantenna.... 16 4.4Mountinginformation.................... 17 4.5Mountinginformation.................... 18 5Connectingtopowersupply 5.1Preparingtheconnection................. 25 5.2Connectionprocedure-Instrumenthousing.... 26 5.3Wiringplans,singlechamberhousing........ 27 5.4Wiringplans,doublechamberhousing....... 29 5.5Wiringplans,doublechamberhousingExd.... 31 5.6Wiringplans,versionIP66/IP68,1bar...... 33 5.7Switch-onphase....................... 33 6Setupwiththeindicatingandadjustmentmodule PLICSCOM 6.1Shortdescription....................... 34 6.2Installingtheindicatingandadjustmentmodule PLICSCOM........................... 34 2VEGAPULS62-4...20mA/HART Contents 28435 - EN - 060317 6.3Adjustmentsystem..................... 35 6.4Adjustmentsystem..................... 36 6.5Setupprocedure....................... 37 6.6Menuschematic....................... 43 6.7Savingtheparameteradjustmentdata....... 46 7SetupwithPACTware™andotheradjustment programs 7.1ConnectingthePC..................... 47 7.2ParameteradjustmentwithPACTware™...... 48 7.3ParameteradjustmentwithAMS™andPDM.. 49 7.4Savingtheparameteradjustmentdata....... 49 8Maintenanceandfaultrectification 8.1Maintenance.......................... 50 8.2Faultrectification....................... 50 8.3Exchangeoftheelectronicsmodule......... 51 8.4Instrumentrepair....................... 52 9Dismounting 9.1Dismountingprocedure.................. 54 9.2Disposal............................. 54 10Supplement 10.1Technicaldata......................... 55 10.2Dimensions........................... 70 10.3Industrialpropertyrights.................. 78 VEGAPULS62-4...20mA/HART3 Contents 28435 - EN - 060317 Supplementaryoperatinginstructionsmanuals Information: VEGAPULS62isavailableindifferentversionsandis suppliedspecificallyacc.totheorder.Dependingonthe selectedversion,supplementaryoperatinginstructionsman- ualscomewiththeshipment.Thesupplementaryoperating instructionsarestatedinparagraph"Productdescription". Operatinginstructionsmanualsforaccessoriesand replacementparts Tip: ToensurereliablesetupandoperationofyourVEGAPULS62, VEGAoffersaccessoriesandreplacementparts.Thecorre- spondingdocumentationsare: lOperatinginstructionsmanual"Externalindicatingand adjustmentunitVEGADIS61" lOperatinginstructionsmanual"OscillatorVEGAPULS series60" lSupplementaryinstructionsmanual"Antennaimpedance coneVEGAPULS62and68" lSupplementaryinstructionsmanual"Flangesacc.toDIN- EN-ASME-JIS" 4VEGAPULS62-4...20mA/HART Contents 28435 - EN - 060317 1Aboutthisdocument 1.1Function Thisoperatinginstructionsmanualhasalltheinformationyou needforquicksetupandsafeoperation.Pleasereadthis manualbeforeyoustartsetup. 1.2Targetgroup Thisoperatinginstructionsmanualisdirectedtotrained, qualifiedpersonnel.Thecontentsofthismanualshouldbe madeavailabletothesepersonnelandputintopracticeby them. 1.3Symbolismused Information,tip,note Thissymbolindicateshelpfuladditionalinformation. Caution:Ifthiswarningisignored,faultsor malfunctionscanresult. Warning:Ifthiswarningisignored,injurytopersonsand/or seriousdamagetotheinstrumentcanresult. Danger:Ifthiswarningisignored,seriousinjurytopersons and/ordestructionoftheinstrumentcanresult. Exapplications ThissymbolindicatesspecialinstructionsforExapplications. lList Thedotsetinfrontindicatesalistwithnoimpliedsequence. àAction Thisarrowindicatesasingleaction. 1Sequence Numberssetinfrontindicatesuccessivestepsinaprocedure. VEGAPULS62-4...20mA/HART5 Aboutthisdocument 28435 - EN - 060317 2Foryoursafety 2.1Authorisedpersonnel Alloperationsdescribedinthisoperatinginstructionsmanual mustbecarriedoutonlybytrainedspecialistpersonnel authorisedbytheoperator.Forsafetyandwarrantyreasons, anyinternalworkontheinstrumentsmustbecarriedoutonly bypersonnelauthorisedbythemanufacturer. 2.2Appropriateuse VEGAPULS62isasensorforcontinuouslevelmeasurement. DetailedinformationontheapplicationrangeofVEGAPULS 62isavailableinchapter"Productdescription". 2.3Warningaboutmisuse Inappropriateorincorrectuseoftheinstrumentcangiveriseto application-specifichazards,e.g.vesseloverfillordamageto systemcomponentsthroughincorrectmountingoradjustment. 2.4Generalsafetyinstructions VEGAPULS62isahigh-techinstrumentrequiringthestrict observanceofstandardregulationsandguidelines.The emittingfrequenciesofallradarsensorsareintheCorK-band range(dependingontheinstrumentversion).Thelowtrans- mittingpowerisfarbelowtheinternationallypermittedlimit values,andwhenusedcorrectly,nohealth-endangering effectsaretobeexpected.Theinstrumentcanalsobeused withoutrestrictiononthesideofmetallic,closedvessels.The usermusttakenoteofthesafetyinstructionsinthisoperating instructionsmanual,thecountry-specificinstallationstandards (e.g.theVDEregulationsinGermany)aswellasallprevailing safetyregulationsandaccidentpreventionrules. 2.5CEconformity VEGAPULS62isinCEconformitywithEMVG(89/336/EWG), R&TTEdirective(1999/5/EC),fulfilsNAMURrecommenda- tionNE21andisinCEconformitywithLVD(73/23/EWG). 1) Conformityhasbeenjudgedacc.tothefollowingstandards: 1) R&TTE-Richtlinie(1999/5/EC):Notwithversionwithincrea…

Text truncated - open the document above for the full version.

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 December 2, 2005 RE: VEGA Grieshaber KG FCC ID: O6QPULS616263 After a review of the submitted information, I have a few comments on the above referenced Application. 1) The test report mentions an off the shelf type power supply was used for AC powerline emissions, however radiated photographs appear to support a lab bench power supply. Please review/explain. Response : The unit is 24 VDC powered; conducted emission is really not applicable in this case because the device does not use an off-the-shelf type power supply. The statement in the report about an “off- the-shelf AC power supply” was an error. The device would typically be installed in industrial sites where a central 24 VDC supply already exists. The conducted data was taken with an unfiltered power line lab bench supply to simulate unfiltered industrial VDC supplies. 2) Please explain the XXXX in section 3 of the report. Response : This was an oversight in the report. This reference was an attestation that conducted output power was verified under normal measurement mode at the manufacturer’s facility. 3) Please explain the duty factor of section 5.3 given the operational description cites a pulse of 1 nS. This makes nearly a 5 dB difference to average readings. Note that the pulse plot appears to support close to 1 ns as well. Response : The duty cycle factor used in the report is correct. The plot used in the report supplied by the manufacturer is that of their 6.3 GHz model radar system. We used the attached attestation provided by the manufacturer to calculate the duty cycle factor. It is evident from the plot values that the pulse period is indeed 1.58 nS; you are right the plot does reveal a 280 nS pulse width and a 1.2 nS pulse period. As you can see from the plot received from the manufacturer we believe that this is an inadvertent mistake and that the values from the attestation are correct. Nonetheless, the attestation is correct with 600 pS pulse width and 280 pS pulse period used for the duty cycle calculation. 4) Given the test distances necessary in the report (3 cm and 30 cm), please explain why the test antennas appear to be at 3 meters in test photos, especially for the parabolic antenna. Response : The test photographs represent mostly the 3 meter test distance when the EUT was investigated between 30 MHz and 1 GHz as a digital device. In the future, photographs of all test distances used will be provided for clarity. 5) FYI...It appears that a straight 20 dB/decade correction factor was applied for correction of distance. However following general mm-wave procedures, you may also use a 40 dB to correct from test distance to far field edge, and then 20 dB is applied for edge of far field to desired distance. Additionally, the far field edge is determined following equations that are dependent on the radiating and receiving elements. Please see attached guidelines for mm-wave measurements. Response : FYI information noted. The FCC /TCB Council Millimeter Wave Test Procedure was used as the guiding document when the device was tested. American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 6) Due to the frequencies and antennas involved, extreme caution should be used when measuring the field strength of emission. The beamwidths are extremely narrow and therefore very small adjustments to the position of the test antennas are required in order to ensure that the measuring instrumentation is within the maximum beam of the transmitted signal. As a result, it is recommended that handheld field strength measurements be made (i.e., the test antenna (horn) is held in the hand). Please provide further detail about how the signals were measured to ensure the main beam was adequately captured. Response : The EUT was tested as described in the FCC/TCB Council Millimeter Wave Test Procedure as stated in #5 in which the mixer/horn was used in a handheld configuration because of the very low nature of the signal level and narrow beamwidth. 7) For table 5-5, please explain the 5.2.0 data shown. Response : Please refer to the revised test report for the proper data in Table 5-5. The spectrum analyzer level column plus the cable loss column plus the antenna gain column equals the spectrum analyzer level corrected. The antenna gain is that of the receiving test antenna. 8) Please explain why the parabolic antenna is only 10 to 14 dB higher than other antennas, but the results appear almost 37 dB higher. This suggests an error in testing, calculations, or possibly a bad sample may have been received. Please review. Response : The difference you noted is a result of the errors in Table 5-5. Please refer to the revised test report uploaded with this response. With Table 5-5 corrected, the difference of 10-14 dB gain between the parabolic antenna and the other antennas is now reduced from 12-19 dB. This difference is well within the uncertainty of the test equipment and the EUT antenna gain used during the measurement. 9) Please explain why the antenna gain in tables 5-1 to 5-4 is 16.8 dB, while table 5-5 is 40 dB. Response : Please see the revised test report uploaded with this response. The gain should be 16.8 dBi from the receiving test antenna. 10) The wording in the manual section 2.7 appears odd. In effort to ensure proper wording for FCC and IC, please add the following to the manual: This device complies with Part 15 and RSS-210 rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. Response : Please see the revised manual uploaded with this response. 11) For IC, please add the information required by RSS-GEN 7.1.4 for detachable antennas to the manual. Response : Please see the revised manual uploaded with this response. 12) For IC, please pro…

Text truncated - open the document above for the full version.

Cover Letter(s)

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 23 of 87 Appendix A: Agency Authorization Please see the following page.

Cover Letter(s)

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 24 of 87 Appendix B: Confidentiality Request Please see the following page.

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 43 of 87 Appendix I: External Photographs Photograph 17: EUT Plastic Housing Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 44 of 87 Photograph 18: EUT Plastic Housing Inside View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 45 of 87 Photograph 19: EUT Plastic Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 46 of 87 Photograph 20: EUT Aluminum Housing Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 47 of 87 Photograph 21: EUT Aluminum Housing Front View

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 48 of 87 Photograph 22: EUT Double Aluminum Chamber Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 49 of 87 Photograph 23: EUT Double Aluminum Housing Fitting Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 50 of 87 Photograph 24: EUT Double Aluminum Chamber Housing Rear View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 51 of 87 Photograph 25: EUT Stainless Steel Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 52 of 87 Photograph 26: EUT Stainless Steel Housing Front View

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 53 of 87 Photograph 27: EUT Stainless Steel Housing Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 54 of 87 Photograph 28: EUT with 19 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 55 of 87 Photograph 29: 19 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 56 of 87 Photograph 30: EUT with 21.2 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 57 of 87 Photograph 31: 21.2 dBi Rod Antenna

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 58 of 87 Photograph 32: EUT with 19.5 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 59 of 87 Photograph 33: 19.5 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 60 of 87 Photograph 34: EUT with 24.7 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 61 of 87 Photograph 35: 24.7 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 62 of 87 Photograph 36: EUT with 33 dBi Parabolic Antenna

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 63 of 87 Photograph 37: 33 dBi Parabolic Antenna Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 64 of 87 Photograph 38: 33 dBi Parabolic Antenna Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 65 of 87 Photograph 39: 33 dBi Parabolic Antenna Side View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 66 of 87 Photograph 40: EUT Antenna Port

ID Label/Location Info

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 26 of 87 Appendix D: Label and Location Photograph 1: FCC ID/IC ID Label Sample for Model VEGAPULS 61 Photograph 2: FCC ID/IC ID Label Sample for Model VEGAPULS 62 Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 27 of 87 Photograph 3: FCC ID/IC ID Label Sample for Model VEGAPULS 63 Photograph 4: FCC ID/IC ID Label Location

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 43 of 87 Appendix I: External Photographs Photograph 17: EUT Plastic Housing Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 44 of 87 Photograph 18: EUT Plastic Housing Inside View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 45 of 87 Photograph 19: EUT Plastic Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 46 of 87 Photograph 20: EUT Aluminum Housing Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 47 of 87 Photograph 21: EUT Aluminum Housing Front View

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 48 of 87 Photograph 22: EUT Double Aluminum Chamber Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 49 of 87 Photograph 23: EUT Double Aluminum Housing Fitting Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 50 of 87 Photograph 24: EUT Double Aluminum Chamber Housing Rear View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 51 of 87 Photograph 25: EUT Stainless Steel Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 52 of 87 Photograph 26: EUT Stainless Steel Housing Front View

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 58 of 87 Photograph 32: EUT with 19.5 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 59 of 87 Photograph 33: 19.5 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 60 of 87 Photograph 34: EUT with 24.7 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 61 of 87 Photograph 35: 24.7 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 62 of 87 Photograph 36: EUT with 33 dBi Parabolic Antenna

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 63 of 87 Photograph 37: 33 dBi Parabolic Antenna Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 64 of 87 Photograph 38: 33 dBi Parabolic Antenna Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 65 of 87 Photograph 39: 33 dBi Parabolic Antenna Side View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 66 of 87 Photograph 40: EUT Antenna Port

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 77 of 87 Photograph 51: EUT Module Parts Inside View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 78 of 87 Photograph 52: EUT Module Parts Side View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 79 of 87 Photograph 53: Module Parts PCB1 Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 80 of 87 Photograph 54: Module Parts PCB1 Bottom View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 81 of 87 Photograph 55: Module Parts PCB2 Top View

Test Report

Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway Suite 1400 Herndon, VA 20170 Phone: 703-689-0368 Fax: 703-689-2056 T T Y Y P P E E C C E E R R T T I I F F I I C C A A T T I I O O N N R R E E P P O O R R T T VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany MODELS: VEGAPULS 61 & VEGAPULS 62 & VEGAPULS 63 FCC ID: O6QPULS616263 IC: 3892A-PS616263 July 30, 2005 Standards Referenced for this Report Part 2: 2001 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15: 2001 Radio Frequency Devices - §15.209: Radiated Emissions Limits RSS-210 Low Power License-Exempt Radio Communication Devices (All Frequency Bands) ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals Frequency Range Output Power (W) Conducted Frequency Tolerance (ppm) Emission Designator 26 GHz N/A 2G3P0N REPORT PREPARED BY TEST ENGINEER: DESMOND FRASER Document Number: 2005169/QRTL05-304 No part of this report may be reproduced without the full written approval of Rhein Tech Laboratories, Inc. Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS61/62/63 Suite 1400 FCC ID: O6QPULS616263 Herndon, VA 20170 Standards: FCC 15.209/RSS-210 http://www.rheintech.com Report Number: 2005169 2 of 87 Table of Contents 1 General Information .................................................................................................................................................... 6 1.1 Test Facility ............................................................................................................................................................................. 6 1.2 Related Submittal(s)/Grant(s)................................................................................................................................................... 6 2 Conformance Statement ............................................................................................................................................. 7 3 Exercising the EUT ..................................................................................................................................................... 8 4 Conducted Limits - §15.207 ........................................................................................................................................ 9 4.1 Conducted Emission Limits Test Data...................................................................................................................................... 9 5 Radiated Emission Limits - §15.209; IC RSS-210 Issue 6 Section 2.6. General Field Strength Level......................10 5.1 Radiated Emission Limits Test Procedure.............................................................................................................................. 10 5.2 Field Strength Calculation ...................................................................................................................................................... 10 5.3 Duty Cycle Calculation.........................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Patrick Friedmann(Product Compliance & QM)
[email protected]+49783650537Fax: +49783650201

Technical Contact

Rhein Tech LaboratoriesDesmond Fraser
[email protected]703 689 0368

360 Herndon Parkway, Suite 1400 · Herndon, Virginia · United States

Non-Technical Contact

Rhein Tech LaboratoriesKathy Grzovic
[email protected]703 689 0368

Test Firm

Rhein Tech Laboratories, Inc.Rick McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115C26.00 GHz - 26.00 GHz-
Confidentiality
Long Term
Grant Notes
This device is authorized for use only with the antennas listed within this application.

Other Applications from VEGA Grieshaber KG

VEGAMET-Air-841-842 - FCC ID O6QMETA84X - VEGA Grieshaber KG
O6QMETA84X

VEGAMET-Air-841-842

Aug 14, 2026

Equipment Class

DTS - Digital Transmission System
O6QDAC1

Display, adjustment and communication module

Jul 27, 2026

Equipment Class

DTS - Digital Transmission System
VEGAMET Air 141 / VEGAMET Air 142 - FCC ID O6QMETA14X - VEGA Grieshaber KG
O6QMETA14X

VEGAMET Air 141 / VEGAMET Air 142

Jul 10, 2026

Equipment Class

DTS - Digital Transmission System
VEGAPULS 42 radar sensor for continuous level measurement - FCC ID O6QPS40W - VEGA Grieshaber KG
O6QPS40W

VEGAPULS 42 radar sensor for continuous level measurement

May 11, 2023

Equipment Class

LPR - Level Probing Radar
Radar sensors for continuous level measurement - FCC ID O6QBRA200 - VEGA Grieshaber KG
O6QBRA200

Radar sensors for continuous level measurement

May 13, 2020

Equipment Class

DTS - Digital Transmission System