FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. VEGA Grieshaber KG/
  3. O6QPULS6566

O6QPULS6566VEGAPULS 65/66 Radar Sensor

VEGA Grieshaber KG
VEGAPULS 65/66 Radar Sensor - FCC ID O6QPULS6566 - VEGA Grieshaber KG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 25, 2005
Application Purpose
Original Equipment
Date of Application
Oct 25, 2005
Equipment Note
VEGAPULS 65/66 Radar Sensor
Frequency Range
6300.00000000 - 6300.00000000
Company
VEGA Grieshaber KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 24 of 47 Appendix G: Manual Please see the following pages. 3TIVEXMRK -RWXVYGXMSRW :)+%4907 Q%,%68 ABILITY WE'VE GOTOO 'SRXIRXW %FSYXXLMWHSGYQ I RX *YRGXMSR 8EVKI X KVSYT 7] QFSPMWQYWIH *SV]SYVWEJI X] %YXLSVMWIHTIVWSRRI P %TTVST VMEXIYWI ;EVRMRK EF SYX Q MWYWI +I RI VEPWEJI X]MRWXVYGXMSRW ')/SRJSVQMXÇX 7EJI X]MRJSVQEXMSR JSV )\ EVIEW  )RZMVSRQ I RXEPMRWXVYGXMSRW 4VSHYGX HI WGVMTXMSR 'SRJMKYVEXMSR %VFI MXW[IMWI %HNYWXQI RX 7XSVEKI ERH XVERWTSVX 1SYRXMRK 1SYRXMRK MRWXVY GXMSRW 1SYRXMRK T VSGI HYVI 1SYRXMRK I \ EQ T PIW 'SRRIGXMRK XSTS[ IVWYTTP] 4VITEVMRK XLI GSRRI GXMSR 'SRRIGXMSR T VSGI HYVI ;MVMRK T PERWWMRKPI GLEQ FI VLSYWMRK ;MVMRK T PERWHSYF PI GLEQ FI VLSYWMRK 7I XYT [ MXLXLI MRHMGEXMRK ERH EHNYWXQIRX QSHYPI40-'7'31 7LSVXHI WGVMTXMSR :)+%4907Q%,%68 'SRXIRXW       )2        -RWXEPPMRK XLI MRHMGE XMRK ERH EHNYWXQI RXQSHYPI 40-' 7' 3 1 %HNYWXQI RXW]WXIQ 7I XYT T VSGI HYVI 1IRYWGL I Q E XMG 7I XYT [ MXL4%'8[EVI¬ 'SRRIGXMRK XLI 4 ' 1EMRXI RERGI ERH JEYPXVIGXMJMGEXMSR 1EMRXIRERGI *EYPXVIGXMJMGE XMSR 6I TEMVMRK XLI MRWXVYQ I RX (MWQSYRXMRK (MWQSYRXMRK T VSGI HYVI (MWTSWEP 7YTTPIQIRX 8I GL RMGE P H E XE (MQI RWMSRW :)+%4907Q%,%68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z0MWX 8LI HSXWIXMRJVSRX MRHMGE XIWEPMWX[ MXLRSMQTPMIH WIUYIRGI Æ%GXMSR 8LMWEVVS[ MRHMGE XIWEWMRKPIEGXMSR :)+%4907Q%,%68 %FSYXXLMWHSGYQ I RX       )2        7I UYI RGI 2YQFI VWWIXMRJVSRX MRHMGE XIWYGGI WWMZI WXITWMRE TVSGI HYVI :)+%4907Q%,%68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 * SV] SYVWEJI X]       )2        ')/SRJSVQMXÇX (IV:)+%4907MWX' )OS R JS VQ^Y)1:+  );+ YRH 2 7 6 );+ WS[ MIHIV6?88) 6MGL XPMRMI )' YRH I VJ²PPXHMI2EQYV )QTJI LPYRK 2) (MI/SRJSVQMXÇX[ YVHI REGL JSPKI RHI R 2 SVQIRFI[ IVXIX z)1:+  )QMWWMSR )2 /PEWWI& -Q Q MWWMSR )2% z276 )2 z- )87 )\TI VX3 TMRMSR 2 S7 ) ) 2SXMJMIH&SH] 2S 7EJI X]MRJSVQ EXMSR JSV) \ EVIEW 4PIEWIRSXIXLI )\ WTI GMJMGWEJI X]MRJSVQEXMSR JSV MRWXEPPEXMSR ERH ST I VEXMS…

Text truncated - open the document above for the full version.

Cover Letter(s)

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 17 of 47 Appendix A: Agency Authorization Please see the following page.

Cover Letter(s)

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 18 of 47 Appendix B: Confidentiality Request Please see the following page.

External Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 28 of 47 Appendix I: External Photographs Photograph 10: Plastic Housing Front View Photograph 11: Plastic Housing Inside View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 29 of 47 Photograph 12: Plastic Housing Fitting Photograph 13: Aluminum Housing Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 30 of 47 Photograph 14: Aluminum Housing Front View Photograph 15: Double Aluminum Chamber Housing Fitting Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 31 of 47 Photograph 16: Double Aluminum Housing Fitting Front View Photograph 17: Double Aluminum Chamber Housing Rear View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 32 of 47 Photograph 18: Stainless Steel Housing Fitting Photograph 19: Stainless Steel Housing Front View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 33 of 47 Photograph 20: Stainless Steel Housing Top View Photograph 21: EUT with 17.0 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 34 of 47 Photograph 22: 17.0 dBi Rod Antenna Photograph 23: EUT with 10.0 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 35 of 47 Photograph 24: 10.0 dBi Horn Antenna Photograph 25: EUT with 21.0 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 36 of 47 Photograph 26: 21.0 dBi Horn Antenna Photograph 27: EUT Antenna Port

ID Label/Location Info

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 20 of 47 Appendix D: Label Information Photograph 1: FCC ID & IC ID Label Sample – VEGAPULS 65 Photograph 2: FCC ID & IC ID Label Sample – VEGAPULS 66 Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 21 of 47 Photograph 3: ID Label Location FCC ID & IC ID Label Here

Internal Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 37 of 47 Appendix J: Internal Photographs Photograph 28: EUT lCD Display Top View Photograph 29: EUT lCD Display Bottom View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 38 of 47 Photograph 30: EUT lCD Display Inside View Photograph 31: EUT lCD Display-PCB Bottom View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 39 of 47 Photograph 32: EUT lCD Display-PCB Top View Photograph 33: Module-Antenna Port View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 40 of 47 Photograph 34: Module Front View Photograph 35: Module Rear View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 41 of 47 Photograph 36: Module Inside View Photograph 37: Module Parts Inside View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 42 of 47 Photograph 38: Module Parts Side View Photograph 39: Module Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 43 of 47 Photograph 40: Module Parts PCB1 Bottom View Photograph 41: Module Parts PCB1 Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 44 of 47 Photograph 42: Module Parts PCB2 Bottom View Photograph 43: Module Parts PCB2 Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 45 of 47 Photograph 44: Module RF PCB with Port Top View Photograph 45: Module RF PCB without Port Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 46 of 47 Photograph 46: Module RF PCB without Port Bottom View Photograph 47: Module RF PCB Shield Top View Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 47 of 47 Photograph 48: Module RF PCB Shield Bottom View

Test Report

Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway Suite 1400 Herndon, VA 20170 Phone: 703-689-0368 Fax: 703-689-2056 T T Y Y P P E E C C E E R R T T I I F F I I C C A A T T I I O O N N R R E E P P O O R R T T VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany MODELS: VEGAPULS 65 & VEGAPULS 66 FCC ID: O6QPULS6566 IC: 3892A-PS6566 July 29, 2003 Standards Referenced for this Report Part 2: 2001 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15: 2001 Radio frequency devices - §15.209: Radiated Emissions Limits ANSI C63.4-2003 Standard Format Measurement/Technical Report Personal Computer and Peripherals RSS-210 Low Power License-Exempt Radio Communication Devices (All Frequency Bands) Frequency Range Output Power (W) Conducted Frequency Tolerance (ppm) Emission Designator 6.3 GHz N/A N/A REPORT PREPARED BY TEST ENGINEER: DESMOND FRASER Document Number: 2005VEGA/QRTL05-304 No part of this report may be reproduced without the full written approval of Rhein Tech Laboratories, Inc. Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 2 of 47 Table of Contents 1 General Information........................................................................................................................................................................................5 1.1 Test Facility ............................................................................................................................................................................. 5 1.2 Related Submittal(s)/Grant(s)................................................................................................................................................... 5 2 Conformance Statement................................................................................................................................................................................6 2.1 Exercising the EUT .................................................................................................................................................................. 7 3 Conducted Limits - §15.207.........................................................................................................................................................................7 4 Radiated Emission Limits - §15.209..........................................................................................................................................................8 4.1 Radiated Emission Limits Test Procedure................................................................................................................................ 8 4.2 Field Strength Calculation ........................................................................................................................................................ 8 4.3 Radiated Emission Limits Test Data......................................................................................................................................... 8 4.4 Test Equipment Used for Testing........................................................................................................................................... 10 5 Tested System Details.................................................................................................................................................................................11 6 Test Plots..........................................................................................................................................................................................................12 7 Conclusion........................................................................................................................................................................................................16 Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 3 of 47 Table of Tables Table 4-1: Field Strength of Carrier with 17.0 dBi Rod Antenna and Plastic Housing ....................................................... 8 Table 4-2: Field Strength of Carrier with 21.0 dBi Horn Antenna and Plastic Housing...................................................... 8 Table 4-3: Field Strength of Carrier with 10.0 dBi Horn Antenna with Plastic Housing ..................................................... 9 Table 4-4: Field Strength of Carrier with All Antennas and Plastic Housing ...................................................................... 9 Table 4-5: Radiated Spurious Emissions Test Equipment .............................................................................................. 10 Table 5-1: Equipment Under Test (EUT)......................................................................................................................... 11 Table of Plots Plot 6-1 Pulse Width and Rise Time Normal Measurement Mode...............................................................................12 Plot 6-2 EUT 17.0 dBi Rod Antenna - 100% Duty Cycle Mode ................................................................................... 13 Plot 6-3 EUT 10.0 dBi Horn Antenna - 100% Duty Cycle Mode .................................................................................. 14 Plot 6-4 EUT 21.0 dBi Horn Antenna - 100% Duty Cycle Mode .................................................................................. 15 Table of Figures Figure 5-1: Configuration of Tested System ................................................................................................................ 11 Table of Appendices Appendix A: Agency Authorization ............................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 25 of 47 Appendix H: Test Configuration Photographs Photograph 4: Radiated Emissions Front View – 17.0 dBi Rod Antenna Photograph 5: Radiated Emissions Rear View – 17.0 dBi Rod Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 26 of 47 Photograph 6: Radiated Emissions Front View - 10.0 dBi Horn Antenna Photograph 7: Radiated Emissions Rear View - 10.0 dBi Horn Antenna Rhein Tech Laboratories Client: VEGA Grieshaber KG 360 Herndon Parkway Models: VEGAPULS 65 & 66 Suite 1400 FCC ID: O6QPULS6566 Herndon, VA 20170 Standards: FCC 15.209 http://www.rheintech.com Report Number: 2005VEGA 27 of 47 Photograph 8: Radiated Emissions Front View - 21.0 dBi Horn Antenna Photograph 9: Radiated Emissions Rear View 21.0 dBi Horn Antenna

Contact Information

Applicant

Patrick Friedmann(Product Compliance & QM)
[email protected]+49783650537Fax: +49783650201

Technical Contact

Rhein Tech LaboratoriesDesmond Fraser
[email protected]703-689-0368

360 Herndon Parkway, Suite 1400 · Herndon, Virginia · United States

Test Firm

Rhein Tech Laboratories, Inc.Rick McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115C6.30 GHz - 6.30 GHz-
Confidentiality
Long Term
Grant Notes
This grant is valid only when the antennas in the Certification filing are used.

Other Applications from VEGA Grieshaber KG

VEGAMET-Air-841-842 - FCC ID O6QMETA84X - VEGA Grieshaber KG
O6QMETA84X

VEGAMET-Air-841-842

Aug 14, 2026

Equipment Class

DTS - Digital Transmission System
O6QDAC1

Display, adjustment and communication module

Jul 27, 2026

Equipment Class

DTS - Digital Transmission System
VEGAMET Air 141 / VEGAMET Air 142 - FCC ID O6QMETA14X - VEGA Grieshaber KG
O6QMETA14X

VEGAMET Air 141 / VEGAMET Air 142

Jul 10, 2026

Equipment Class

DTS - Digital Transmission System
VEGAPULS 42 radar sensor for continuous level measurement - FCC ID O6QPS40W - VEGA Grieshaber KG
O6QPS40W

VEGAPULS 42 radar sensor for continuous level measurement

May 11, 2023

Equipment Class

LPR - Level Probing Radar
Radar sensors for continuous level measurement - FCC ID O6QBRA200 - VEGA Grieshaber KG
O6QBRA200

Radar sensors for continuous level measurement

May 13, 2020

Equipment Class

DTS - Digital Transmission System