Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Sep 20, 2001
Application Purpose
Original Equipment
Date of Application
Jun 12, 2001
Frequency Range
450.00000000 - 490.00000000
Company
Midland Radio Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗
↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 44 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX G: MANUAL PL2445 / PL2245 Operating Instructions ProLine Series ABOUT Topaz3 Topaz3 is the exclusive supplier of Maxon , Legacy and Tru Talk brand communication products. Our product line ranges from FCC licensed two-way radios suitable for Business and Industry (B&I) markets like farm, government, law enforcement, utility, etc. to consumer recreational and light-duty business markets. Product offerings include a variety of UHF and VHF handheld and mobile radios, repeaters and RF link modules as well as FRS (Family Radio Service), GMRS (General Mobile Radio Service) radios, Citizen’s Band radios and weather monitors. Available accessory items include: a variety of carrying cases, spare batteries, desktop and mobile chargers, ear bud speaker microphones, and more for each radio model. For additional information on our product line, visit our website: www.topaz3.com Table of contents . FCC RF Exposure Compliance Requirements for Occupational Use Only . Unpacking and Checking Equipment . Getting started Charging the NiMH Battery Pack Attaching and Removing the Battery Pack Installing the Antenna Installing the Belt Clip Installing the Speaker Mic. Jack Cover Attaching the Optional Speaker Microphone . Radio Control Buttons / Operation Speaker Features . Radio Operation Power On / Transmit . Channel Frequency Selection . CTCSS Tone Signaling VIII. Radio Functions Scan Modes Busy Channel Lockout Marked Idle TX delay Time-Out-Timer (T-O-T) Time-Out-Timer Penalty Battery Save Low Battery Warning Two-tone Decode I . Licensing, Safety and Service Information FCC Licensing Safety Information Service X. Maintenance I. Software Copyrights II. Topaz3 / Legacy Product Warranty . FCC RF Exposure Compliance Requirements for Occupational Use Only The Federal Communications Commission (FCC), with its action in General Docket 93-62, November 7, 1997, has adopted a safety standard for human exposure to Radio Frequency (RF) electromagnetic energy emitted by FCC regulated equipment. Topaz3 / Legacy subscribes to the same safety standard for the use of its products. Proper operation of this radio will result in user exposure far below the Occupational Safety and Health Act (OSHA) and Federal Communications Commission limits. Caution: DO NOT transmit for more than 50% of total radio use time (50% duty cycle). Transmitting more than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. l This radio is NOT approved for use by the general population in an uncontrolled environment. This radio is restricted to occupational use, work related operations only where radio operator must have the knowledge to control the user’s exposure conditions for satisfying the higher exposure limit allowed for occupational use. l When transmitting, hold the radio in a vertical position with its microphone 2 inches (5 cm) away from your mouth. l This device has been approved for use, at a maximum duty factor of 50%, using the specific belt clip and leather belt-holster tested for body-worn SAR compliance. Other belt clips or body-worn accessories may not comply and should be avoided. The radio is transmitting when the red LED on the front of the radio is illuminated. You can cause the radio to transmit by pressing the P-T-T bar ont he radio. l These are required operating configurations for meeting FCC RF exposure compliance. Failure to observe these restrictions mean violation. . Unpacking and Checking Equipment Carefully unpack the radio and its accessories. Use the item list below to identify the components included in the product packing, to ensure that no items are discarded in the packing materials. Radio Body Antenna Battery Charger (with plastic spacer) AC Adapter NiMH Battery Pack Speaker Microphone Jack Cover Belt Clip Screw Set Operating Instructions If any items are missing or damaged, you should contact the Topaz3 Customer Service Department. Dial 1-800-821- 7848, Ext. 499 for assistance. . Getting Started Charging the NiMH Battery Pack You will need to change the battery pack fully before initial use. For best results from your charging cycle, follow these tips: l Ensure the ambient temperature is between 41 and 104 (5 and 40) while charging. Temperatures outside this range may not fully charge the battery. l Always switch OFF the transceiver equipped with a NiMH battery pack before charging. Using the radio during the charging cycle will hinder correct charging. l Do not recharge the battery pack if it is already fully charged. Doing so may cause the life of the battery pack to shorten or the battery pack may be damaged. l If the battery is stored for 2 months or more, it is a good idea to complete the charge / discharge cycle two or three times to allow the battery capacity to return to normal. l Never dispose of the battery in fired – it can explode causing personal injury. l Never attempt to disassemble the battery or remove its case material or charging contacts. Do not short the battery terminals. Note: The first few uses from the battery will not be at “normal” capacity. After repeating the charge / discharge cycle two or three times, the battery capacity will increase to provide full capacity. 1. Plug the AC adapter cable in the adapter jack located on the rear of the charger, then into an AC outlet. 2. Slide the NiMH battery pack (or the radio equipped with a NiMH battery pack) into the charging slot. 3. Ensure that the metal contacts on the battery pack come in contact with the charging terminals. 4. When charging the NiMH battery pack alone, insert the provided plastic spacer into the charging well, then insert the battery pack. 5. The charger LED will light to advise that charging has begun. Charge the standard battery pack for 9 hours, THEN REMOVE THE PACK OR RADIO FROM THE CHARGER. …

Text truncated - open the document above for the full version.

Block Diagram

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 43 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX F: BLOCK DIAGRAM      

External Photos

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 51 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX J: EXTERNAL PHOTOGRAPHS PHOTOGRAPH 9: FRONT VIEW 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 52 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 10: LEFT SIDE VIEW 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 53 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 11: RIGHT SIDE VIEW 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 54 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 12: REAR VIEW 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 55 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 13: TOP VIEW 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 56 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 14: BOTTOM VIEW

ID Label/Location Info

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 40 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX C: LABEL INFORMATION FCC ID Label Topaz3, L.L.C. PL12245/PL2445 Mobile Radio FCC ID: O7KPL450A CAUTION LABEL DEVICE MUST BE RESTRICTED TO OCCUPATIONAL USE TO SATISFY FCC RF EXPOSURE COMPLIANCE. SEE OWNER’S MANUAL FOR SPECIFIC OPERATING INSTRUCTIONS. CAUTION “FCC Caution Label” prints white letters on black adhesive stock. Typefont is Universe Condensed, 8 pt. Trim marks do not print. Final cut label is 31 mm wide x 13 mm tall !!!! ! !!!! !

Internal Photos

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 47 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX I: INTERNAL PHOTOGRAPHS PHOTOGRAPH 5: FRONT VIEW OF PCB 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 48 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 6: BACK VIEW OF PCB 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 49 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 7: FRONT VIEW OF PCB INSIDE CHASSIS 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 50 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio PHOTOGRAPH 8: INSIDE VIEW OF FRONT CHASSIS

Operational Description

Frequency Range148-174 MHz450-490 MHz Channels4 (PL2415); 2 (PL2215)4 (PL2245); 2 (PL2245P) Channel Spacing25 / 30 / 15 / 12.5 kHz 25 / 12.5 kHz PLL Step2.5 / 5 / 6.25 / 7.5 kHz 5.0 / 6.25 kHz Channel Spread26 MHz40 MHz Antenna Impedance50 Ω50 Ω Operating Voltage7.2V DC Nominal7.2V DC Nominal Battery Life (with 750 mAh NiMH battery)11 Hours @ 2 W11 Hours @ 2 W (90-5-5 duty cycle)(90-5-5 duty cycle) (with optional 1350 mAh NiMH battery)19 Hours @ 2 W19 Hours @ 2 W (90-5-5 duty cycle)(90-5-5 duty cycle) Operating Temperature-22 o F to +140 o F (-30 o C to +60 o C) Frequency Stability (-30 o C to +60 o C)± 5.0 ppm± 5.0 ppm Dimensions (H x W x D) (with battery)4-7/8" x 2-1/4" x 1-1/4" (125 x 58 x 32 mm) Weight (with 750 mAh NiMH battery and antenna)13.6 oz. (380 gm) FCC IdentifierPendingPending FCC ComplianceParts 22, 74, 80, 90Parts 22, 74, 90, 95 IC Certification NumberPendingPending StandardStandard StandardStandard Standard 810F810F 810F810F 810F Metho Metho Metho Metho Metho dd dd d / Procedure / Procedure / Procedure / Procedure / Procedure Light Rain506.4 / Proc. II Humidity507.4 / Proc. I Dust510.4 / Proc. I Vibration514.5 / Proc. I Shock516.5 / Proc. I, IV Sensitivity 12 dB SINAD.25 μV @12.5 kHz; .28 μV @25 kHz Selectivity>60 dB @12.5 kHz; >65 dB @ 25 kHz Intermodulation60 dB @ 12.5 kHz; 65 dB @ 25 kHz Spurious Response60 dB60 dB Audio Output500 mW (Int.) @ 8 Ω; 500 mW (Ext.) @ 8 Ω (Method @ <10% THD level) RF Output2 Watts2 Watts Spurious and Harmonic Emissions60 dB60 dB Modulation16K0F3E, 11K0F3E FM Hum and Noise>34 dB @ 12.5 kHz; >40 dB @ 25 kHz Audio Distortion<5%<5% Specifications are subject to change without notice. spespe spespe spe cc cc c ii ii i ff ff f icationsications icationsications ications 10828 NW Air World Drive Kansas City, Missouri 64153 800-821-7848, Ext. 699 ï Fax: 816 / 891-8815 www.topaz3.com For more information, contact: receiver (measurement procedures made per ANSI / TIA / EIA - 603) ProLine PL2415 / PL2445; PL2215 / PL2245P VHF modelUHF model PL2415; PL2215 PL2445; PL2245P Batteries:Batteries: Batteries:Batteries: Batteries: 750 mAh NiMH Battery pack (ACC-201); 1350 mAh NiMH Battery pack (ACC-202) Antenna:Antenna: Antenna:Antenna: Antenna: VHF Antenna, 6", 148-174 MHz (ACC-115); UHF Antenna, 6", 450-490 MHz (ACC-145) Charger:Charger: Charger:Charger: Charger: Single unit desktop "slow" charger (ACC-410) Audio:Audio: Audio:Audio: Audio: Lapel speaker microphone with ear jack, locking connector (ACC-726) Carrying:Carrying: Carrying:Carrying: Carrying: Leather case (ACC-302) accessories / optionsaccessories / options accessories / optionsaccessories / options accessories / options Supplier of MaxonÆ, Legacy and TruTalk products MILMIL MILMIL MIL -STD methods / pr-STD methods / pr -STD methods / pr-STD methods / pr -STD methods / pr ocedurocedur ocedurocedur ocedur eses eses es general The ProLine PL2415, PL2445, PL2215 and PL2245 meet the following: ï 4 Channel, 2 Watt VHF model PL2415; UHF model PL2445 2 Channel, 2 Watt VHF model PL2215; UHF model PL2245P ï Programmable wide or narrow channel spacing ï Meets MIL-STD810F specifications ï 38 Standard, 11 non-standard CTCSS tones; 104 DCS tones ï Programmable two-tone decode ï Programmable scan ï Locking single-pin accessory connector ï TX Inhibit ï Time-out-timer ï Battery save circuitry ï Die-cast aluminum frame, polycarbonate cabinet ï Tri-color LED ï Spring steel belt clip ï Manufactured under ISO 9002 quality standards ï FCC Certified for use in U.S.A and its possessions featurfeatur featurfeatur featur es / functionses / functions es / functionses / functions es / functions P/N: 680-120-2038, Rev. A transmitter (measurement procedures made per ANSI / TIA / EIA - 603)

Parts List/Tune Up Info

360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com FCC And Canadian Certification Report Page 41 of 57 2001140 / QRTL01-118 Topaz3, L.L.C. PL2445/PL2245P Mobile Radio APPENDIX D: PARTS LIST                     ! !" #  ## $%&       '(   )  $ &"&      '(   $  *# $%&       '(   *  *) %       '(   +  ,*  %  +& &"&      '(   ,   *+! +&,*- ..( "('! /  # && +&,*- ..( "('! &  ) $"%! +&,*- ..( "('!   $ ##& +&,*- ..( "('! #  * +, +&,*- ..( "('! )  + *! +&,*- ..( "('! $  % && +&,*- ..( "('! *  , &! +&,*- ..( "('! +  / ##& +&,*- ..( "('! %  & *&! +&,*- ..( "('! ,   )")! +&,*- ..( "('! /  # ##& +&,*- ..( "('! #&  ) )/0 +&,*- ..( "('! #  $ $%0 +&,*- ..( "('! ##  * +,&0 +&,*- ..( "('! #)  + $"%0 +&,*- ..( "('! #$  % && +&,*- ..( "('! #*  , &&0 +&,*- ..( "('! #+  / 0 +&,*- ..( "('! #%  #& &! +&,*- ..( "('! #,  # #"%! +&,*- ..( "('! #/  ## ,& +&,*- ..( "('! )&  #) &! +&,*- ..( "('! )  #$ 0 +&,*- ..( "('! )#  #* &0 +&,*- ..( "('! ))  #+ &0 +&,*- ..( "('! )$  #% #"%0 +&,*- ..( "('! )*  #, )"+0 +&,*- ..( "('! )+  #/ )")0 +&,*- ..( "('! )%  )& 0 +&,*- ..( "('! ),  ) 0 +&,*- ..( "('! )/  )# $%! +&,*- ..( "('! $&  )) ##& +&,*- ..( "('! $  )$ 1&,&*2  *- ..( "('! $#  )* ,"#0 +&,*- ..( "('! $)  )+ #"#0 +&,*- ..( "('! $$  )% )/ +&,*- ..( "('! $*  ), ##&0 +&,*- ..( "('! $+  )/ &0 +&,*- ..( "('! $%  $& ##! +&,*- ..( "('! $,  $ $"%! +&,*- ..( "('! $/  $# &0 +&,*- ..( "('! *&  $) &! +&,*- ..( "('! *  $$ &! +&,*- ..( "('! *#  $* &! +&,*- ..( "('! *)  $+ &! +&,*- ..( "('! *$  $% &&! +&,*- ..( "('! **  $, &&! +&,*- ..( "('! *+  $/ ##0 +&,*- ..( "('! *%  *& ",! +&,*- ..( "('! *,  * 0 +&,*- ..( "('! */  *# $%&0 +&,*- ..( "('! +&  *) +#0 +&,*- ..( "('! +  *$ )"/0 +&,*- ..( "('! +#  ** ,"#0 +&,*- ..( "('! +)  *+ & +&,*- ..( "('! +$  *% +, +&,*- ..( "('! +*  *, ,& +&,*- ..( "('! ++  */ ##&0 +&,*- ..( "('! +%  +& ",0 +&,*- ..( "('! +,  + &&0 +&,*- ..( "('! +/  +# ! +&,*- ..( "('! %&  +) ,"#0 +&,*- ..( "('! %  +$ ' +&,*- ..( "('! %#  +* *0 +&,*- ..( "('! %)  ++ &&0 +&,*- ..( "('! %$  +% #&&0 +&,*- ..( "('! %*  +, )/&0 +&,*- ..( "('! %+  +/ *0 +&,*- ..( "('! %%  %& *! +&,*- ..( "('! %,  % #"%0 +&,*- ..( "('! %/  %# $%&0 +&,*- ..( "('! ,&  %) & +&,*- ..( "('! ,  %$ #"#0 +&,*- ..( "('! ,#  %* ##! +&,*- ..( "('! ,)  %+ *+&! +&,*- ..( "('! ,$  %% )"/! +&,*- ..( "('! ,*  %, & +&,*- ..( "('! ,+  %/  ,%  ,& &"&      '(   ,,  , ,#0 +&,*- ..( "('! ,/  ,# &&0 +&,*- ..( "('! /&  ,) #&0 +&,*- ..( "('! /  ,$ &&0 +&,*- ..( "('! /#  ,* *&0 +&,*- ..( "('! /)  ,+ &&0 +&,*- ..( "('! /$  ,% ##! +&,*- ..( "('! /*  ,, )/0 +&,*- ..( "('! /+  ,/ ))0 +&,*- ..( "('! /%  /& ))! +&,*- ..( "('! /,  / #%! +&,*- ..( "('! //  /# ##&0 +&,*- ..( "('! &&  /) +,&! +&,*- ..( "('! &  /$ +,0 +&,*- ..( "('! &#  /* #0 +&,*- ..( "('! &)  /+ #"%! +&,*- ..( "('! &$  /% &! +&,*- ..( "('! &*  /, +,0 +&,*- ..( "('! &+  // && +&,*- ..( "('! &%  && #"#0 +&,*- ..( "('! &,  & 0 +&,*- ..( "('! &/  &# &! +&,*- ..( "('! &  &) && +&,*- ..( "('!   &$ ##0 +&,*- ..( "('! #  &* )/0 +&,*- ..( "('! )  &+ ))&0 +&,*- ..( "('! $  &% $"%0 +&,*- ..( "('! *  &, )0 +&,*- ..( "('! +  &/ 0 +&,*- ..( "('! %  & #&0 +&,*- ..( "('! ,   ))0 +&,*- ..( "('! /  # $%& +&,*- ..( …

Text truncated - open the document above for the full version.

RF Exposure Info

CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. CERTIFICATE OF COMPLIANCE SAR EVALUATION This wireless portable device has been shown to be compliant for localized Specific Absorption Rate (SAR) for controlled environment/occupational exposure limits specified in ANSI/IEEE Std. C95.1-1992 and has been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1999. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Lab 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information: TOPAZ3, LLC 10828 NW Air World Drive, Kansas City, Missouri 64153-1238 FCC ID: O7KPL450A Model(s): PL2445 EUT Type: Portable UHF PTT Radio Transceiver Modulation: FM (UHF Band) Tx Frequency Range: 450.0125 - 489.9875 MHz Max. Power Tested: 2.16 Watts (Conducted) No. of Channels: 4 FCC Rule Part(s): 2.1093; ET Docket 96-326 CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TABLE OF CONTENTS 1.0 INTRODUCTION.................................................................. 1 2.0 DESCRIPTION OF EUT.......................................................... 1 3.0 SAR MEASUREMENT SYSTEM ............................................. 2 4.0 MEASUREMENT SUMMARY.................................................. 3-5 5.0 DETAILS OF SAR EVALUATION............................................ 6 6.0 EVALUATION PROCEDURES................................................. 6 7.0 SAR LIMITS........................................................................ 7 8.0 SYSTEM VALIDATION.......................................................... 7 9.0 SIMULATED EQUIVALENT TISSUES...................................... 8 10.0 TISSUE PARAMETERS......................................................... 8 11.0 SYSTEM SPECIFICATIONS.................................................... 9 12.0 TEST EQUIPMENT LIST........................................................ 10 13.0 MEASUREMENT UNCERTAINTIES........................................ 11 14.0 REFERENCES...................................................................... 12 APPENDIX A - SAR MEASUREMENT DATA........................................ 13 APPENDIX B - DIPOLE VALIDATION................................................ 14 APPENDIX C - PROBE CALIBRATION............................................... 15 APPENDIX D - SAR TEST SETUP PHOTOGRAPHS............................... 16 APPENDIX E - EUT PHOTOGRAPHS................................................. 17 CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TOPAZ3 FCC ID: O7KPL450A (Model: PL2445) 1 Portable UHF PTT Radio Transceiver (450-490MHz) 1.0 INTRODUCTION This measurement report shows compliance of the TOPAZ3 PL2445 Portable UHF PTT Radio Transceiver FCC ID: O7KPL450A with the regulations and procedures specified in FCC Part 2.1093, ET Docket 96-326 Rules (controlled exposure) for mobile and portable devices. The test procedures, as described in American National Standards Institute C95.1-1992 (1), FCC OET Bulletin 65-1997 were employed. A description of the product and operating configuration, detailed summary of the test results, methodology and procedures used in the evaluation, equipment used, and the various provisions of the rules are included within this test report. 2.0 DESCRIPTION of Equipment Under Test (EUT) Front of EUT Right Side of EUT Left Side of EUT Back of EUT EUT with Holster Rule Part(s) FCC 2.1093; ET Docket 96.326 Modulation FM (UHF Band) EUT Type Portable UHF PTT Radio Transceiver Tx Frequency Range (MHz) 450.0125 - 489.9875 Model No.(s) PL2445 Max. RF Output Power Tested 2.16 Watts (Conducted) Serial No. Pre-production Power Supply 7.2V NiMH Battery Antenna Type Whip Antenna Length 153 mm CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TOPAZ3 FCC ID: O7KPL450A (Model: PL2445) 2 Portable UHF PTT Radio Transceiver (450-490MHz) 3.0 SAR MEASUREMENT SYSTEM Celltech Research SAR measurement facility utilizes the Dosimetric Assessment System (DASY™) manufactured by Schmid & Partner Engineering AG (SPEAG™) of Zurich, Switzerland. The DASY system is comprised of the robot controller, computer, near-field probe, probe alignment sensor, and the generic twin phantom containing brain or muscle equivalent material. The robot is a six-axis industrial robot performing precise movements to position the probe to the location (points) of maximum electromagnetic field (EMF). A cell controller system contains the …

Text truncated - open the document above for the full version.

RF Exposure Info

Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 •• Fax. 250-860-3110 •• [email protected] www.celltechlabs.com September 13, 2001 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Joe Dichoso SUBJECT: TOPAZ3, L.L.C. FCC ID: O7KPL450A 731 Confirmation No.: EA101329 Correspondence Ref. No.: 20546 Dear Joe: On behalf of Topaz3, L.L.C. we hereby submit our response to Item #1 of your e-mail dated September 07, 2001 requesting additional information for the subject application. At the time the device was evaluated for RF exposure, the thickness of the planar phantom had not yet been addressed by the manufacturer. The system was validated at the time of the device evaluation and the target numbers were achieved to within the measurement error allotted. Due to the recent reported increase in the thickness of phantom from the required 2.0mm to 3.2mm, the manufacturer reported new system validation target values for our newly calibrated 1800MHz and 900MHz dipoles. At 1800MHz with a separation distance of 10mm from the center of the dipole axis to the fluid, and at 900MHz with separation distances of 15mm, the new target values are lower then expected by 12% and 8% respectively. As the frequency is reduced further, the error due to the increased phantom thickness becomes less significant. Since the manufacturer has not given target values for other frequencies, it is estimated by extrapolation that at 450MHz the actual measured SAR values are approximately 5% lower than expected. This would cause both face-held and body-worn RF exposure evaluations to be approximately 5% lower than reported since they were both performed in the planar section of the phantom. Please find attached the revised SAR test report showing the extrapolated SAR values and reported increase in phantom thickness from the system manufacturer. This device is intended to be granted for Controlled Exposure/Occupational, and in both face-held and body-worn configurations there is sufficient margin for SAR at a 100% duty cycle with a spatial peak limit of 8.0W/Kg. If you have any questions or comments concerning the above, please do not hesitate to contact me. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Topaz3 L.L.C. Rhein Tech Labs CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. CERTIFICATE OF COMPLIANCE SAR EVALUATION This wireless portable device has been shown to be compliant for localized Specific Absorption Rate (SAR) for controlled environment/occupational exposure limits specified in ANSI/IEEE Std. C95.1-1992 and has been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1999. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Lab 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information: TOPAZ3, LLC 10828 NW Air World Drive, Kansas City, Missouri 64153-1238 FCC ID: O7KPL450A Model(s): PL2445 EUT Type: Portable UHF PTT Radio Transceiver Modulation: FM (UHF Band) Tx Frequency Range: 450.0125 - 489.9875 MHz Max. Power Tested: 2.16 Watts (Conducted) No. of Channels: 4 FCC Rule Part(s): 2.1093; ET Docket 96-326 CELLTECH RESEARCH INC. Test Report S/N: 052801-121O7K 1955 Moss Court, Kelowna Date(s) of Tests: May 31, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TABLE OF CONTENTS 1.0 INTRODUCTION.................................................................. 1 2.0 DESCRIPTION OF EUT.......................................................... 1 3.0 SAR MEASUREMENT SYSTEM ............................................. 2 4.0 MEASUREMENT SUMMARY.................................................. 3-5 5.0 DETAILS OF SAR EVALUATION............................................ 6 6.0 EVALUATION PROCEDURES................................................. 6 7.0 SAR LIMITS........................................................................ 7 8.0 SYSTEM VALIDATION...........................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jeff Brame(Director of Engineering)
[email protected]816-241-8500Fax: 816-241-5713

Technical Contact

Rhein Tech Laboratories Inc.Bruno Clavier
[email protected]703-689-0368

360 Herndon Parkway · Herndon, Virginia · United States

Non-Technical Contact

Rhein Tech Laboratories, Inc.Melissa Carter
[email protected]703-689-0368

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222,74,90,95A450 MHz - 490 MHz2.18 W16K0F3E5 ppm

Other Applications from Midland Radio Corporation

VHF Radio Transmitter - FCC ID O7KSD161 - Midland Radio Corporation
O7KSD161

VHF Radio Transmitter

Jun 12, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
UHF Data Transceiver - Transmitter - FCC ID O7KSD164 - Midland Radio Corporation
O7KSD164

UHF Data Transceiver - Transmitter

Jun 02, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
UHF 32 Channel Mobile Radios - FCC ID O7KML3245 - Midland Radio Corporation
O7KML3245

UHF 32 Channel Mobile Radios

Jan 27, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
32 Channel Mobile Radio - FCC ID O7KML3215 - Midland Radio Corporation
O7KML3215

32 Channel Mobile Radio

Jan 09, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
PL5164 Portable Radio - FCC ID O7KPL5164 - Midland Radio Corporation
O7KPL5164

PL5164 Portable Radio

May 29, 2002

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face