OGN5032-49R3 Channel Turbo Bump

Kwok's Winty Manufacturing Ltd.
3 Channel Turbo Bump - FCC ID OGN5032-49R - Kwok's Winty Manufacturing Ltd.
Click to zoom

Application Details

Equipment Class
CRR - Superregenerative Receiver
Date of Grant
Oct 18, 2000
Application Purpose
Original Equipment
Date of Application
Sep 07, 2000
Equipment Note
3 Channel Turbo Bump
Frequency Range
49.82000000 - 49.90000000
Company
Kwok's Winty Manufacturing Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Schematics

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FRONT VIEW OF DEVICE

ID Label/Location Info

BOTTOM VIEW OF DEVICE WITH FCC ID LABEL FCC ID LABEL FCC ID:OGN5032-49R MADE IN CHINA This device complies with part 15 of FCC Rules. Operation is subject to the following two condition: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FRONT VIEW OF THE PRINTED WIRING BOARD BOTTOM VIEW OF THE PRINTED WIRING BOARD

Test Report

Date: 2000-08-31 TEST REPORT Page 1 of 5 No.: HM102887 Law Man KitKitty ChoyPatrick Wong Test EngineerVerify byPatrick Wong Director for Managing APPLICANT: (CODE:KWW003) KWOK’S WINTY MANUFACTURING LTD. Unit A 12/F., Shing King Ind. Bldg., 45 Kut Shing Street, Chai Wan, Hong Kong. DATE OF SAMPLE(S) RECEIVED: 2000-07-06 DATE OF TESTING: 2000-08-15 DESCRIPTION OF SAMPLE(S): A sample of product said to be: Product:3 CHANNEL TURBO BUMP Manufacturer:KWOK’S WINTY MANUFACTURING LTD. Model Number:05032 Brand Name:N/A Rating:3.0V d.c. Origin:CHINA INVESTIGATIONS REQUESTED: Measurement to the relevant clauses of F.C.C. Rules and Regulations Part 15 Subpart B - Unintentional Radiator. RESULT/ REMARK:Please see attached sheet(s). CONCLUSION: From the measurement data obtained, the tested sample was considered to have COMPLIED after modification with the clause 15.109(a) & ANSI C63.4:1992 section 12.1.1.1-2 of Federal Communications Commission Rules and Regulations Part 15. TEST EQUIPMENT AUDIT: Please see Appendix A MODIFICATION: Changed the length of the antenna to 23cm. Date: 2000-08-31 TEST REPORT Page 2 of 5 No.: HM102887 T E S T S U M M A R Y ***UNINTENTIONAL RADIATOR*** (A) Measurement of Radiated Emissions.................................................Satisfactory (B) Line Conducted Voltage Test............................................................Not applicable T E S T D A T A Please refer to the attached result sheets. Date: 2000-08-31 TEST REPORT Page 3 of 5 No.: HM102887 ***UNINTENTIONAL RADIATOR*** ** RECEIVER SECTION ** (A) Measurement of Radiated Interference TEST REFERENCE: FCC Rules Part 15 Subpart B section 15.109(a) TEST CONDITION : Normal TEST DATE : 2000-08-15 ================================================================== Freq. to Freq. of PolarizationMeterAntennaField Strength (at 3m)FCC whichthereadingfactorLimit tunedemission(at 3m)@ MHzMHzH-VdBdB( μV)μV/mμV/m 49.8649.9H21.9+15.036.970.040100 99.7<1.0+12.2<13.2<4.643.5150 149.6<1.0+9.8<10.8<3.543.5150 199.4<1.0+11.5<12.5<4.243.5150 249.3<1.0+15.9<16.9<7.046200 299.2<1.0+17.0<18.0<7.946200 349.0<1.0+17.2<18.2<8.146200 398.9<1.0+18.8<19.8<9.846200 448.7<1.0+19.7<20.7<10.846200 498.6<1.0+20.6<21.6<12.046200 548.5<1.0+22.2<23.2<14.546200 598.3<1.0+23.4<24.4<16.646200 648.2<1.0+23.5<24.5<16.846200 698.0<1.0+25.0<26.0<20.046200 747.9<1.0+26.3<27.3<23.246200 797.8<1.0+27.2<28.2<25.746200 847.6<1.0+26.6<27.6<24.046200 897.5<1.0+27.1<28.1<25.446200 947.3<1.0+28.0<29.0<28.246200 997.2<1.0+28.5<29.5<29.954500 ================================================================== ==========SUMMARY========== All data is within limits ============================= Broad-band Antennas were used and both polarizations of emissions were measured Polarizations at highest reading indicated as: H -- HorizontalV -- Vertical ============================ Date: 2000-08-31 TEST REPORT Page 4 of 5 No.: HM102887 NOTES FOR THE RADIATION MEASUREMENT (1) Test site facility: Open field test site located at Taipo (Hong Kong) with a metal ground plane on filed with the FCC pursuant to section 2.948 of the FCC Rules. (2) Distance between the EUT and measuring antenna: 3 meters. (3) Measuring instrumentation’s: CISPR Quasi-peak type field strength meter (25 MHz - 1000 MHz.). 6 dB bandwidth set at 120 KHz. Also, peak level of the fundamental emissions was measured in order to determine compliance with the 20dB peak to average limit specified in Section 15.35(b) of the FCC new Rules. (4) Measuring antenna: Broad band antenna for the frequency range 25-1000 MHz, connected with 10 meters coaxial cable. Cable loss of the coaxial cable included in the Antenna Factor for measurement data. The antenna are capable of measuring both horizontal and vertical polarizations. (5) Frequency range scanned: The frequency range from 25 MHz to 1000 MHz had been searched. Readings of the highest emissions relating to the limit were reported as above. (6) Arrangement of EUT: During the test, the sample was operated at rated supply voltage and arranged for maximum emissions. (7) Measuring Procedure: In accordance with the relevant clauses of the FCC Rules Part 15 section 15.109(a) and ANSI C63.4:1992 section 12.1.1.1-2. For superregenerative receivers, an independent signal generator had been used to radiated an unmodulated were (cw) signal to the receiver at its operating frequency in order to “cohere” or resolve the individual components of the characteristic broadband emission from such a receiver. The level of such signal may need to be adjusted in order to accomplish this. (8) Measuring Uncertainty: The calculated uncertainty for measurement performed at 3M test distance are:- 30MHz to 300MHz = ± 3.7dB, 300MHz to 1000MHz = + 3.0dB/-2.7dB. Remark: Purpose of this test is to provide the Applicant with the necessary test data of their device for the submission to FCC with application for Equipment Authorization under FCC’s Equipment Authorization Program. This test itself is not an Approval Test. *** End of Document *** Date: 2000-08-31 TEST REPORT Page 5 of 5 No.: HM102887 TEST EQUIPMENT AUDIT Radiated Emission EQP NO.DESCRIPTIONMANUFACTURERMODEL NO.SERIAL NO.LAST CAL. EM007SPECTRUM ANALYZERHEWLETT PACKARDHP85660B3144A2119218/07/00 EM008SPECTRUM ANALYZER DISPLAYHEWLETT PACKARDHP85662A3144A2051418/07/00 EM009QUASI PEAK ADAPTORHEWLETT PACKARDHP85650A3303A0170218/07/00 EM010RF PRESELECTORHEWLETT PACKARDHP85685A3221A0141018/07/00 EM011ATTENNUATOR/SWITCHHEWLETT PACKARDHP11713A2508A1059518/07/00 EM012PRE-AMPLIFIERHEWLETT PACKARDHP8449B3008A0026218/07/00 EM013CONTROLLER (COMPUTER), COLOR MONITOR, KEYBOARD & MOUSE FLOPPY DRIVE HEWLETT PACKARD HEWLETT PACKARD HEWLETT PACKARD HP9000 HP A1097C HP9133L 6226A60314 3151J39517 2623A02468 CM EM131PORTABLE SPECTRUM ANALYSERHEWLETT PACKARD8595EM3710A0015525/11/99 EM017ANTENNAARA INC.LPB-2513/A106917/02/00 EM020HORN ANTENNAEMCO3115403230/06/97 EM072SIGNAL GENERATORHEWLETT PACKARD8640B1948A1189230/03/98 EM083HKSTC OPEN AREA TEST SITEHKSTCN/AN…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Paul Chan(Director)
852-2558-2118

Technical Contact

The Hong Kong Standards & Testing Centre Ltd.Patrick Wong
[email protected]852 2666 1820

10 Dai Wang St., Taipo Ind'l Estate · NT · Hong Kong

Non-Technical Contact

The Hong Kong Standards & Testing Centre Ltd.Patrick Wong
[email protected]852 2666 1820

Test Firm

Hong Kong Standards & Testing Cen.Wilson Wong
[email protected]852-2666-1888Fax: 852-2664-4353

Technical Specifications

#Rule PartsFrequency RangePower Output
115B49.82 MHz - 49.9 MHz-

Other Applications from Kwok's Winty Manufacturing Ltd.

3 Channel Turbo Blimp - FCC ID OGN5032-27T - Kwok's Winty Manufacturing Ltd.
OGN5032-27T

3 Channel Turbo Blimp

Jan 24, 2001

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Toy Remote Control - FCC ID OGN5032-49T - Kwok's Winty Manufacturing Ltd.
OGN5032-49T

Toy Remote Control

Sep 28, 2000

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
REMOTE CONTROL TOY CAR - FCC ID OGN7221 - Kwok's Winty Manufacturing Ltd.
OGN7221

REMOTE CONTROL TOY CAR

May 24, 1999

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter