FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CIAS Elettronica S.R.L./
  3. OIFERMO-482XPRO-K

OIFERMO-482XPRO-KMicrowave barrier

CIAS Elettronica S.R.L.
Microwave barrier - FCC ID OIFERMO-482XPRO-K - CIAS Elettronica S.R.L.
Click to zoom

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Jan 21, 2013
Application Purpose
Original Equipment
Date of Application
Jan 21, 2013
Equipment Note
Microwave barrier
Frequency Range
24123.00000000 - 24123.00000000
Company
CIAS Elettronica S.R.L.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ERMO 482x PRO Barriera a Microonde per protezioni esterne Manuale di Installazione External Microwave Protection Barrier Installation Handbook Edizione / Edition 5.1  CIAS Elettronica S.r.l. Ed. 5.1 Manuale di Installazione Pagina 1 di 59 ERMO 482X PRO INDICE 1. DESCRIZIONE ....................................................................................................................................................................... 3 1.1 DESCRIZIONE ...................................................................................................................................................................... 3 1.2 SCHEMA A BLOCCHI ............................................................................................................................................................ 4 2. INSTALLAZIONE .................................................................................................................................................................. 5 2.1 INFORMAZIONI PRELIMINARI ............................................................................................................................................... 5 2.2 NUMERO DI TRATTE ............................................................................................................................................................ 5 2.3 CONDIZIONI DEL TERRENO .................................................................................................................................................. 6 2.4 PRESENZA DI OSTACOLI ...................................................................................................................................................... 6 2.5 AMPIEZZA DEI FASCI SENSIBILI ........................................................................................................................................... 7 2.6 LUNGHEZZA DELLE ZONE MORTE IN PROSSIMITÀ DEGLI APPARATI ..................................................................................... 9 3. COLLEGAMENTI ............................................................................................................................................................... 11 3.1 MORSETTIERE, CONNETTORI E FUNZIONALITÀ DEI CIRCUITI ............................................................................................. 11 3.1.1 Circuito Trasmettitore ............................................................................................................................................. 11 3.1.2 Circuito Ricevitore ........................................................................................................................................... 14 3.2 COLLEGAMENTO ALL’ALIMENTAZIONE PRINCIPALE ......................................................................................................... 17 3.2.1 Collegamento all’Alimentazione ............................................................................................................................. 17 3.2.2 Collegamento all’Alimentazione di Riserva ............................................................................................................ 17 3.3 COLLEGAMENTO ALLA CENTRALE .................................................................................................................................... 18 3.3.1 Contatti di allarme: Allarme, Guasto, Manomissione ............................................................................................ 18 3.3.2 Connessioni per Sincronismo .................................................................................................................................. 19 3.3.3 Connessioni per Stand-by ....................................................................................................................................... 19 3.3.4 Connessioni per Test ............................................................................................................................................... 19 3.3.5 Connessioni per Linea Bilanciata ........................................................................................................................... 19 3.4 LINEA SERIALE RS-485 .................................................................................................................................................... 21 3.4.1 Interfaccia Linea Seriale RS-485 / 232 / USB ......................................................................................................... 21 3.4.2 Connessioni per Linea Seriale RS-485 .................................................................................................................... 21 3.4.3 Configurazione Rete e Rigeneratori di segnale ...................................................................................................... 21 4. ALLINEAMENTO E VERIFICA........................................................................................................................................ 23 4.1 ALLINEAMENTO E VERIFICA .............................................................................................................................................. 23 4.1.1 Operazioni sul Trasmettitore................................................................................................................................... 23 4.1.2 Operazioni sul Ricevitore ........................................................................................................................................ 24 4.2 ALLINEAMENTO E VERIFICA CON SOFTWARE .................................................................................................................... 28 5. MANUTENZIONE E ASSISTENZA .................................................................................................................................. 29 5.1 RICERCA GUASTI ...........................................................................................................................................…

Text truncated - open the document above for the full version.

External Photos

Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 26 of 32 An ne x B E x te rna l ph ot ogra phs o f the E UT Photo 3: Photo 4:

ID Label/Location Info

Label for Ermo 482 Transmitter Label for ERMO482XPROF5 Transmitter Trade Name: CIAS Elettronica Model No:ERMO482 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: OIFERMO-482 IC: 332510-21411A CIAS Elettronica ERMO482XPROF5 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: OIFERMO-482X-PRO-K IC: 3325A-ERMOPROK

Internal Photos

Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 27 of 32 An ne x C Inte r na l p ho to gra phs o f the E UT Photo 5: Photo 6: Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 28 of 32 Photo 7: Photo 8: Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 29 of 32 Photo 9: Photo 10: Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 30 of 32 Photo 11: Photo 12:

Test Report

2012-09-04 Page 1 of 32 TEST REPORT Test report no.: 1-4554/12-01-02-B Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Area of Testing: Radio/Satellite Communications CIAS Elettronica s.r.l. Via Durando, 38 20158 Milano / ITALY Phone: +39 0 23 76 71 61 Fax: +39 0 23 93 11 225 Contact: Alfonso Orsanigo e-mail: [email protected] Phone: +39 0 23 76 71 61 Manufacturer CIAS Elettronica s.r.l. Via Durando, 38 20158 Milano / ITALY Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I Part 15 - Radio frequency devices RSS - 210 Issue 8 Spectrum Management and Telecommunications - Radio Standards Specification Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Microwave barrier Model name: ERMO482XPROF5 FCC ID: OIFERMO-482PRO-K IC: 3325A-ERMOPROK Frequency: 24.075 GHz – 24.175 GHz Antenna: Parabolic integrated Power Supply: 13.8 V DC from power supply Temperature Range: -25 °C to +55 °C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: Karsten Geraldy Meheza Walla Senior Testing Manager Expert Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 2 of 32 1 Table of contents 1 Table of contents............................................................................................................................................2 2 General information .......................................................................................................................................3 2.1 Notes and disclaimer ..........................................................................................................................3 2.2 Application details...............................................................................................................................3 3 Test standard/s ...............................................................................................................................................3 4 Test environment............................................................................................................................................4 5 Test item ..........................................................................................................................................................4 6 Test laboratories sub-contracted .................................................................................................................4 7 Summary of measurement results ...............................................................................................................5 8 RF measurement testing................................................................................................................................6 8.1 Description of test setup ....................................................................................................................6 8.1.1 Radiated measurements.............................................................................................................6 8.1.2 Additional comments ..................................................................................................................7 9 Measurement results......................................................................................................................................8 9.1 Field strength of emissions (wanted signal) ....................................................................................8 9.2 Occupied bandwidth (99% bandwidth) ...........................................................................................11 9.3 Field strength of emissions (radiated spurious) ............................................................................14 9.4 Conducted spurious emissions < 30 MHz ......................................................................................21 10 Test equipment and ancillaries used for tests ...................................................................................23 11 Observations .........................................................................................................................................24 Annex A Photographs of the test setup ......................................................................................................25 Annex B External photographs of the EUT.................................................................................................26 Annex C Internal photographs of the EUT ..................................................................................................27 Annex D Document history ..........................................................................................................................31 Annex E Further information........................................................................................................................31 Annex F Accreditation Certificate ...............................................................................................................32 Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 3 of 32 2 General information 2.1 Notes and disclaimer The test results of this test report relate exclusively to the test item specified in this test report. CET…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report no.: 1-4554/12-01-02-B 2012-09-04 Page 25 of 32 An ne x A P ho tog ra phs o f t h e te s t s e tu p Photo 1: Photo 2:

Contact Information

Applicant

Giuseppe Leonardi(President, Executive Board)
[email protected]+39 02 3767161Fax: +39 02 39311225

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115.24524.12 GHz - 24.12 GHz-
Confidentiality
Long Term

Other Applications from CIAS Elettronica S.R.L.

Microwave Protection Barrier - FCC ID OIFERMO-482X3PROK - CIAS Elettronica S.R.L.
OIFERMO-482X3PROK

Microwave Protection Barrier

Oct 08, 2023

Equipment Class

FDS - Part 15 Field Disturbance Sensor
MICROWAVE BARRIER - FCC ID OIFCORAL-PLUS - CIAS Elettronica S.R.L.
OIFCORAL-PLUS

MICROWAVE BARRIER

Sep 27, 2015

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Microwave Sensor - FCC ID OIFMURENA - CIAS Elettronica S.R.L.
OIFMURENA

Microwave Sensor

Sep 07, 2010

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Microwave Barrier - FCC ID OIFERMO-482X-PRO - CIAS Elettronica S.R.L.
OIFERMO-482X-PRO

Microwave Barrier

Mar 20, 2005

Equipment Class

FDS - Part 15 Field Disturbance Sensor
FDS - Part 15 Field Disturbance Sensor - FCC ID OIFERMO-482 - CIAS Elettronica S.R.L.
OIFERMO-482

FDS - Part 15 Field Disturbance Sensor

Apr 14, 1999

Equipment Class

FDS - Part 15 Field Disturbance Sensor