FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. iFIT Health and Fitness, Inc./
  3. OMC425339

OMC425339Tablet

iFIT Health and Fitness, Inc.
Tablet - FCC ID OMC425339 - iFIT Health and Fitness, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 13, 2020
Application Purpose
Original Equipment
Date of Application
Oct 12, 2020
Equipment Note
Tablet
Frequency Range
2412.00000000 - 2462.00000000
Company
iFIT Health and Fitness, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 ICON Tablet Model: MP10-Argon 2 2 Directions Meanings of icons: Forbidding: forbid improper operations to avoid damaging the tablet. Caution: cautions for operators to avoid potential damages. Please note and remember. Importance: important information, common notes, definitions, general knowledge and references, etc. Other trademarks and trade name may be used in this manual to refer to either the entities claiming the marks and names or their products. The manufacture disclaims any proprietary interest in trademarks and trade names other than its own. Information in this manual is subject to change without notice. Reproduction in any manner whatsoever without the written permission from the manufacture is strictly forbidden. Product images in this manual are for your reference only. 3 Contents Directions ......................................................................... 2 Safety Precautions .......................................................... 5 1 Know Your Tablet......................................................... 7 2 Get to Know Your System ........................................... 7 2-1 Add screen shortcuts ............................................... 8 2-2 Delete screen shortcuts/widgets ........................... 10 2-3 On-screen Keyboard .............................................. 11 3 System Settings ......................................................... 12 3-1 Wireless & networks ............................................... 12 3-2 Device ...................................................................... 15 3-3 Personal .................................................................. 16 3-4 System ..................................................................... 16 4 Browser ....................................................................... 17 4 5 Camera ........................................................................ 18 6 Specifications ............................................................. 20 7 CE Mark ....................................................................... 21 8 Shell ......................................................................... 24 5 Safety Precautions 1. DO NOT expose the tablet to dirty or dusty environment. Keep the environment clean and dry. 2. DO NOT place or drop objects on the top of the tablet. DO NOT shove any foreign objects into the tablet. DO NOT cover the LCD Screen strongly. 3. DO NOT expose the tablet to strong magnetic or electrical fields; DO NOT place the floppy disk near or on the tablet, which may loss the data of the floppy disk. 4. DO NOT leave the tablet facing the sun as it can damage the LCD Screen, especially in the car. 5. DO NOT expose the tablet to or use near liquids, rain, or moisture. 6. DO NOT throw the tablet in municipal waste. Check local regulations for disposal of electronic products. 8. DO NOT insert anything into the tablet that may result in short circuit or damage the circuit. 9. Power off the tablet, if you want to install or remove some external devices which are not support hot-plug. 10. DO NOT disassemble the tablet, only a certified service technician should perform repairs on your computer. Otherwise, problems may result and the manufacturer should not hold responsibility for the damage. 11. Direct current To indicate on the rating plate that the equipment is suitable for direct current only; to identify relevant terminals. 6 12. Meaning of crossed –out wheeled dustbin。Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge. 13. the product complies with the essential requirements of the relevant European health, safety and environmental protection legislation. 14. For AC/DC Adapter, the socket-outlet shall be installed near the equipment and shall be easily accessible. 15. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Please kindly known that the tablet is ONLY used/fixed 7 1 Know Your Tablet KEYS: connect to the console through a cable, so that the host can control the volume or reset AUDIO JACK: connect to the console through a cable to provide audio signal output. Picture1-1 in the treadmill 8 2 Get to Know Your System Connect to the power supply and then it will display the home screen as below picture . Click on the screen for ten times, pause for 5 seconds and then do it again for ten times’ clicks to enter the Setting priviledged mode as below. 9 Quick settings 10 : tap to return to the previous page. : tap to enter Home screen. : tap to open recent APPs list menu. : tap to enter APPs Menu. If it’s your first time to use the tablet, the system will enter the guide menu. Please finish the initial setting following the instructions. 2-1 Add screen shortcuts On the home page, touch and hold the blank area to popup menu to change wallpaper; Touch to access APPS menu as shown in picture 2-3; touch and hold an APPS icon to add it to the home screen. Picture 2-2 11 2-2 Delete screen shortcuts/widgets On the home screen, touch and hold the shortcut or widget to be deleted until the icon “×” appears at the top middle of the home screen. Drag the shortcuts to the remove icon to delete. 2-3 On-screen Keyboard Just touch a text field to open the on-screen keyboard; Touch on the tool bar to close it. Toggle letters & numbers Space Caps lock Backspace Go Picture 2-3 Picture 2-4 Expression 12 3 System Settings 3-1 Wireless & networks 3-1-1 Wi-Fi Touch the Wi-Fi swtich behind of the Wi-…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (obsolete) 4.0 5.0 Sep-16-2014 Updated company name & logo (current) 5.0 6.0 Jun-27-2018 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 6.0 Icon Health and Fitness, Inc. Date:2020-09-09 To: BVCPS, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Icon Health and Fitness, Inc. hereby authorize Bureau Veritas Consumer Product Services, Inc. to act as a Certification Body for certifying for the following project(s): FCC ID: OMC425339 Product Description: Tablet Model: MP10-Argon2 Sincerely, Client’s signature : Client’s name / title: Craig Jensen ,Compliance Engineer Contact information / address: Icon Health and Fitness, Inc. 1500 South 1000 West, Logan Utah, United States 84321 Tel: (435) 786-5915 E-mail :[email protected]

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 3 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526- 1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 - Software Security SCS-F19: Confidentiality Request Letter Page 2 of 3 Rev 6.0 Icon Health and Fitness, Inc. Date:2020-09-09 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: OMC425339 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name & title: Craig Jensen ,Compliance Engineer Contact information / address: Icon Health and Fitness, Inc. 1500 South 1000 West, Logan Utah, United States 84321 Tel: (435) 786-5915 E-mail:[email protected] SCS-F19: Confidentiality Request Letter Page 3 of 3 Rev 6.0 Icon Health and Fitness, Inc. Date:2020-09-09 To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Short Term Confidentiality Request for FCC ID: OMC425339 To Whom It May Concern: Pursuant to sections 0.457 and 0.459 of CFR 47, and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of / / not to exceed 180 days from the Grant Date. See KDB 726920. - User Manual - Internal Photos - Test Setup photos The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Client’s signature: Client’s name & title: Craig Jensen , Compliance Engineer Contact information / address: Icon Health and Fitness, Inc. 1500 South 1000 West, Logan Utah, United States 84321

Cover Letter(s)

SCS-F190 WiFi Channel 12&13 Declaration Letter Page 1 of 2 Rev.2.0 Created by William Graff Approved by Bao-Thuong Nguyen WIFI Channel 12 and 13 Declaration Letter Reason for Amendment Revision History Approved Date From To Initial Release (obsolete) Initial 1.0 December 22, 2015 Modify the select options (current) 1.0 2.0 September 23, 2016 FCC ID: SCS-F190 WiFi Channel 12&13 Declaration Letter Page 2 of 2 Rev.2.0 Created by William Graff Approved by Bao-Thuong Nguyen Icon Health and Fitness, Inc. WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo-location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Craig Jensen ,Compliance Engineer Signature: Phone: (435) 786-5915 Email: [email protected] Date:2020-09-09 OMC425339

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 200618N021 PHOTOGRAPHS OF THE EUT BT/WIFI ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 200618N021 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 200618N021 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 200618N021

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 7 Report Version 1 Test Report No.: FM200618N021 RF EXPOSURE REPORT Applicant Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Manufacturer or Supplier Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Product Tablet Brand Name N/A Model MP10-Argon2 Additional Model & Model Difference N/A Date of tests Jun. 18, 2020 ~ Aug. 31, 2020 FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Lucas Chen Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 25, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 7 Report Version 1 Test Report No.: FM200618N021 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE LIMIT ..................................................................................... 5 3. MPE CALCULATION FORMULA ..................................................................... 5 4. CLASSIFICATION ........................................................................................... 5 5. ANTENNA GAIN .............................................................................................. 6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 7 Report Version 1 Test Report No.: FM200618N021 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM200618N021 Original release Sep. 25, 2020 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 7 Report Version 1 Test Report No.: FM200618N021 1. CERTIFICATION PRODUCT: Tablet BRAND NAME: N/A MODEL NO.: MP10-Argon2 ADDITIONAL MODEL: N/A FCC ID: OMC425339 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: ICON HEALTH AND FITNESS INC. TESTED DATES: Jun. 18, 2020 ~ Sep. 04, 2020 STANDARDS: FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 7 Report Version 1 Test Report No.: FM200618N021 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 7 Report Version 1 Test Report No.: FM200618N021 5. ANTENNA GAIN The antennas provided to the EUT, please refer to the following t…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 41 Report Version 1 Test Report No.: RF200618N021-2 TEST REPORT Applicant Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Manufacturer or Supplier Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Product Tablet Brand Name N/A Model MP10-Argon2 Additional Model & Model Difference N/A Date of tests Jun. 18, 2020 ~ Sep. 04, 2020 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 ANSI C63.10-2013 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Lucas Chen Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 25, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 41 Report Version 1 Test Report No.: RF200618N021-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................. 6 3.2 DESCRIPTION OF TEST MODES ............................................................................................... 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 7 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 10 3.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................... 10 4 TEST TYPES AND RESULTS .......................................................................................................11 4.1 CONDUCTED EMISSION MEASUREMENT .............................................................................. 11 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................ 11 4.1.2 TEST INSTRUMENTS ...................................................................................................... 11 4.1.3 TEST PROCEDURES ..................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 12 4.1.5 TEST SETUP ................................................................................................................... 13 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 13 4.1.7 TEST RESULTS .............................................................................................................. 14 4.2 RADIATED EMISSION MEASUREMENT .................................................................................. 16 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 16 4.2.2 TEST INSTRUMENTS ..................................................................................................... 17 4.2.3 TEST PROCEDURES ..................................................................................................... 18 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 19 4.2.5 TEST SETUP ................................................................................................................... 19 4.2.6 EUT OPERATING CONDITIONS .................................................................................... …

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 54 Report Version 1 Test Report No.: RF200618N021-3 TEST REPORT Applicant Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Manufacturer or Supplier Icon Health and Fitness, Inc. Address 1500 South 1000 West, Logan Utah, United States 84321 Product Tablet Brand Name N/A Model MP10-Argon2 Additional Model & Model Difference N/A Date of tests Jun. 18, 2020 ~ Sep. 04, 2020 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 ANSI C63.10-2013 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Lucas Chen Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Sep. 25, 2020 This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 54 Report Version 1 Test Report No.: RF200618N021-3 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ............................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................... 6 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 8 3.3 DUTY CYCLE OF TEST SIGNAL ............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Kris Luthy(Regulatory Compliance Engineer)
[email protected]8014355420Fax: 435-750-7739

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz261.27 mW
Confidentiality
Long Term
Grant Notes
RF output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from iFIT Health and Fitness, Inc.

OMC-CESIUM1

Tablet

Sep 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
OMC453584C

Tablet

Aug 21, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
OMC453084

Tablet

Jul 15, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
OMC453584V

Tablet

May 10, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Tablet - FCC ID OMC436392E - iFIT Health and Fitness, Inc.
OMC436392E

Tablet

Sep 26, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter