Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Original instructions AUTEC Dynamic Series LIFJRE00-01.fmPart C: FJR transmitting unit ENG DYNAMIC SERIES Part C: FJR transmitting unit INDEX 1 Description ........................................................................................................... C - 2 2 Technical data ...................................................................................................... C - 3 3 Technical data sheet ........................................................................................... C - 3 4 Plates .................................................................................................................... C - 4 5 Light signals ........................................................................................................ C - 4 6 Malfunction signalled by the transmitting unit ................................................. C - 6 Dynamic Series Part C: FJR transmitting unit Description C - 2 1 Description Aconnector for wire control (if present)B actuators (joysticks, selectors, pushbuttons) CSTOP pushbuttonDdisplay or LED (if present) ELEDsFSTART pushbutton GS-KEY (electronic starting key) D A EBB B B G C B F Technical data AUTEC Dynamic Series LIFJRE00-01.fmPart C: FJR transmitting unit C - 3 ENG 2 Technical data Power supply (battery MBM06MH)................................................................. NiMH 7.2 V Antenna ................................................................................................................... internal Housing material ........................................................................................... PA 6 (20% fg) Protection degree ....................................................................................... IP65 (NEMA 4) Dimensions ......................................................... 260 x 200 x 190 mm (10.2 x 7.9 x 7.5 In) Weight .......................................................................................................... 2.0 kg (4.4 Lb) Run time (at 20°C / 68°F) ............................................................................................ 11 h Run time with Data Feedback (at 20°C / 68°F) .......................................................... 9.5 h Run time with Low Power (at 20°C / 68°F) .................................................................. 14 h Run time with Data Feedback and Low Power (at 20°C / 68°F) ............................... 12.5 h 3 Technical data sheet The technical data sheet contains the transmitting unit configuration and shows the matching between commands sent and machine functions/movements. It also contains the wiring diagram showing the connection between the receiving unit and the machine. Each technical data sheet must be filled in, checked and signed by the installer, who is responsible for a correct wiring. A copy of the technical data sheet must always be kept together with this manual (always keep a copy of this data sheet for administrative purposes). The wiring of the receiving unit outputs must always reflect the wiring indi- cated in the technical data sheet. Dynamic Series Part C: FJR transmitting unit Plates C - 4 4Plates The transmitting unit has three plates. 5 Light signals The FJR transmitting units may have two or four LEDs. In both cases, two LEDs are always available, providing information regarding the radio remote control. - a green LED identified with - a red LED identified with PlatePositionContent radio remote control identification plate On the S-KEY: remove the S- KEY to read the plate. Radio remote control serial number (S/N). transmitting unit iden- tification plate In the battery housing: remove the battery to read the plate. Manufacturing year, bar code and transmitting unit identifi- cation number (TU ID). technical data plate In the battery housing: remove the battery to read the plate. MODEL, TYPE and main transmitting unit technical data, marking and possible radio remote control marks. The green LED ... Meaning ... is offThe transmitting unit is switched off. ... blinks fast The transmitting unit is switched on and there is no radio link. ... blinks slowly The radio remote control is started and the radio link is present. Light signals AUTEC Dynamic Series LIFJRE00-01.fmPart C: FJR transmitting unit C - 5 ENG - If it has 4 LEDs, the side LEDs are red and provide information coming from the machine (Data Feedback function). The red LED a ... a. An acoustic signal is also heard when the red LED is illuminated. Meaning ... is offThe transmitting unit works correctly. ...blinksThe battery is nearly flat. ... is on for 2 seconds b b. After this signal, the transmitting unit switches off. The transmitting unit does not work correctly. ... blinks once b At power on, the transmitting unit detects that the STOP pushbutton is activated or damaged. ... blinks twice b At power on, the transmitting unit detects that one of the commands D2-D20 or SAFETY is activated or damaged (see technical data sheet). ... blinks three times b At power on, the transmitting unit detects that the bat- tery is flat. ... blinks four times b At power on, the transmitting unit detects that one of the commands A1-A8, L1-L8 and H1-H8 is activated or damaged (see technical data sheet). Dynamic Series Part C: FJR transmitting unit Malfunction signalled by the transmitting unit C - 6 6 Malfunction signalled by the transmitting unit Use the light signals on the transmitting unit to identify the radio remote control malfunction. If the problem persists after the suggested solution has been carried out, contact the support service of the machine manufacturer. ** Procedure to save the address - press the STOP pushbutton - press the START pushbutton and do not release it until the green LED switches off - unlock the STOP pushbutton Signals Possible reason Solutions The green LED does not switch on when the START pushbutton is pressed, even though both the battery and the S-KEY are inserted. The battery is flat. Replace t…
Text truncated - open the document above for the full version.
Dynamic series user manual Description, warnings and instructions Conformity and frequencies (915 MHz) Original instructions The attached documentation is an integral part of the radio remote control and it aims at provid- ing the instructions needed for using and maintaining the system, with an eye on its safety func- tions. Always remember that: - photos and drawings are useful examples that help understand the instructions and warnings of each radio remote control configuration - if necessary, contact Autec if any of the instructions and/or warnings are not clear No part of the documentation may be reproduced, in any form or by any means, without written permission of Autec (including recording and photocopying). If documentation is lost or damaged, ask Autec for a copy. Please specify the serial number of the related radio remote control. The documentation must be kept for the whole life of the radio remote control: after reading it, keep it on hand for future reference. Information contained in the documentation adds to and completes the information provided by the manufacturer of the remote controlled and/or by those who install the radio remote control on the machine. All installation, usage and maintenance operations must be carried out by qualified technicians who are suitably trained with respect to the relevant norms and laws. Therefore, this documentation must be read and understood in all its parts by the user and by: - the radio remote control owner and/or installer - the person responsible for and in charge of maintenance and/or safety in the workplace where the radio remote control is used. As for instructions and warnings regarding the machine where the radio remote control is installed, follow the instructions given in the machine's manual. Three symbols are employed throughout documentation, which are used to highlight specific safety-related issues. They are classified according to the hazardous situation that may arise and on the possible consequences: This symbol is also used, and it identifies texts to be read carefully. Symbol If the highlighted instructions are not respected this... ... leads to a dangerous situation ... ... may lead to conse- quences for people ... ... may lead to conse- quences for property ... ...highly probable. ... critical (death or physical damage). ... critical. ... probable. ... critical (death or physical damage). ... critical. ... probable. ... moderate (non- severe physical dam- age). ... moderate. AUTEC ENG INDEX Part A: Description, warnings and instructions 1 Dynamic Series description ............................................................................... A - 1 1.1 Technical data ................................................................................................. A - 1 1.2 Applications ..................................................................................................... A - 2 1.3 Radio link ........................................................................................................ A - 2 1.4 Classification of commands ............................................................................ A - 2 1.5 Safety functions .............................................................................................. A - 3 1.6 Identifying the radio remote control ................................................................. A - 4 2 Risk assessment ................................................................................................. A - 5 2.1 Risk assessment for radio remote controlled machines ................................. A - 5 2.2 Working conditions .......................................................................................... A - 6 3 Warnings .............................................................................................................. A - 7 3.1 Before starting to work .................................................................................... A - 7 3.2 During normal operation ................................................................................. A - 7 3.3 After using the radio remote control ................................................................ A - 8 4 Radio remote control lifecycle ........................................................................... A - 9 4.1 Transportation and storage ............................................................................. A - 9 4.2 Installation ....................................................................................................... A - 9 4.3 Use .................................................................................................................. A - 9 4.4 Radio remote control maintenance ............................................................... A - 10 4.5 Machine maintenance ................................................................................... A - 14 4.6 Disposal ........................................................................................................ A - 14 5 General operating instructions ........................................................................ A - 15 5.1 Starting up the radio remote control .............................................................. A - 15 5.2 Command activation ..................................................................................... A - 15 5.3 Data Feedback Function ............................................................................... A - 15 5.4 Radio link interruption ................................................................................... A - 16 5.5 Transmitting unit automatic switch off ........................................................... A - 16 5.6 Switching off the transmitting unit ................................................................. A - 17 5.7 Switching off the receiving unit ..................................................................... A - 17 6 Working ...................................…
Text truncated - open the document above for the full version.
Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 1 of 2 EXTERNAL PHOTO Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 2 of 2
FJR label and its dimension FJR label position Labels_and_position_fjr_rev1.cdr 6 0 , 0 m m 50,0 mm (under the battery) Technical Data POWER SUPPLY.....................................................7.2V RADIO MODULE..............................................FSARTBAU1 FREQUENCY RANGE......................................915-928MHz PROTECTION DEGREE...............................................IP65 TA1201-01 A0TARG01P0943 TYPE NF022MODEL: FJR --- IC: 9061A-FJRNF022 This radio device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. N12335 FCC ID: OQA-FJRNF022
Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 1 of 3 INTERNAL PHOTO Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 2 of 3 Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 3 of 3
Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Test report R12089001 Rev. 1.0 Order M120890 page 1 of 80 TEST REPORT nr. R12089001 Federal Communication Commission (FCC) Industry Canada (IC) Test item Description .................... : Transceiver Unit Trademark ..................... : AUTEC Model/Type ................... : Model FJR Type NF022 Test Specification Standard ........................ : FCC Rules & Regulations, Title 47 (2011) - Part 15 paragraph(s) : 247(a), 247(b), 247(c), 209 and 207 RSS-210 (2010) – Annex 8 Client’s name ............... : AUTEC S.r.l. Address ......................... : Via Pomaroli, 65 - 36030 Caldogno (VI) - ITALY Manufacturer’s name . : Same ad client Address ......................... : Report Tested by ....................... : G. Gandini - Technician Approved by .................. : R. Beghetto - Laboratory Manager Date of issue .................. : 11.02.13 Contents ........................ : 80 pages This test report shall not be reproduced except in full without the written approval of CMC. The test results presented in this report relate only to the item tested. CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) Test report R12089001 Rev. 1.0 Order M120890 page 2 of 80 Index 1. SUMMARY ............................................................................................................................................................. 3 2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ................................................................................. 4 2.1 TEST SITE .............................................................................................................................................................. 4 3. TESTING AND SAMPLING ................................................................................................................................. 4 4. OPERATIVE CONDITIONS................................................................................................................................. 4 5. PHOTOGRAPH(S) OF EUT ................................................................................................................................. 5 6. EQUIPMENT LIST ................................................................................................................................................ 6 7. MEASUREMENT UNCERTAINTY .................................................................................................................... 7 8. REFERENCE DOCUMENTS ............................................................................................................................... 8 9. DEVIATION FROM TEST SPECIFICATION ................................................................................................... 9 10. TEST CASE VERDICTS........................................................................................................................................ 9 11. RESULTS................................................................................................................................................................. 9 11.1 ANTENNA REQUIREMENTS ............................................................................................................................. 10 11.2 20DB BANDWIDTH ......................................................................................................................................... 11 11.3 OCCUPIED BANDWIDTH (99% BW) ................................................................................................................ 12 11.4 CHANNEL SEPARATION ................................................................................................................................... 13 11.5 TIME OF OCCUPANCY ..................................................................................................................................... 14 11.6 NUMBER OF HOPPING CHANNELS ................................................................................................................... 15 11.7 PEAK OUTPUT POWER .................................................................................................................................... 16 11.8 BAND EDGE .................................................................................................................................................... 18 11.9 RADIATED SPURIOUS (TRANSMITTER) ............................................................................................................ 20 11.10 RADIATED SPURIOUS (RECEIVER)................................................................................................................... 23 12. GRAPHS AND TABLES ...................................................................................................................................... 25 CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) Test report R12089001 Rev. 1.0 Order M120890 page 3 of 80 1. Summary Standard: FCC Rules & Regulations, Title 47 RSS-210 (2007) Test specifications Environmental Phenomena Tests sequence Result FCC – Title 47 Part 15.203 and 15.204 IC – RSS-210 Antenna Requirement 1 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 20 dB Bandwidth 2 Complies IC – RSS-210 Annex 8 Occupied Bandwidth (99% BW) 3 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 Channel Separation 4 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 Time of Occupancy 5 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 Number of Hopping Frequency 6 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 Peak Output Power 7 Complies FCC – Title 47 Part 15.247 IC – RSS-210 Annex 8 Band Edge 8 Complies FCC – Title 47 Par…
Text truncated - open the document above for the full version.
Independent Testing Laboratory CMC Centro Misure Compatibilità S.r.l. Via dell’Elettronica, 12/C 36016 Thiene (VI) – ITALY Tel./Fax +39 0445 367702 www.cmclab.it - [email protected] Accredited by Ministry of Communications – Notified Body EMC Directive 2004/108/EC n° NB 2044 Page 1 of 1 SETUP PHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915.05 MHz - 927.95 MHz | 23.30 mW |

Transceiver Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Transceiver unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Transceiver unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Transceiver Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Transceiver Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter