FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Autec s.r.l./
  3. OQA-TF02B07D

OQA-TF02B07DRemote Control Transmitter TF02B07D

Autec s.r.l.
Remote Control Transmitter TF02B07D - FCC ID OQA-TF02B07D - Autec s.r.l.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 19, 2004
Application Purpose
Original Equipment
Date of Application
Sep 19, 2004
Equipment Note
Remote Control Transmitter TF02B07D
Frequency Range
902.15000000 - 927.72500000
Company
Autec s.r.l.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Transmitter System USER’S MANUAL Modular Series Follow the indications and warnings given by the machine producer regarding the machine controlled by the radio remote control. The information contained in this manual considers a representative configuration of the radio remote control: please find radio remote control real configuration in the technical data sheet (attached to the manual). If this manual is lost or damaged, ask for a copy from AUTEC. Please specify the serial number of the relative radio remote control. Contact AUTEC if any of the instructions and/or warnings given in this manual are not clear. The information contained in this manual is subject to modification without notice and is not binding. No parts of this manual may be reproduced by any means without the written permission of AUTEC (including recording and photocopying). LIMJNMA01 - Index and conventionsPage 1 of 16 1 INDEX AND CONVENTIONS INDEX 1 Index and conventions..................................................................................................... 1 2 Introduction...................................................................................................................... 2 3 MJ transmitting unit .........................................................................................................5 4 Warnings for use .............................................................................................................7 5 Warnings for maintenance............................................................................................... 8 6 MJ transmitting unit operation ....................................................................................... 11 7 Frequencies...................................................................................................................13 8 Programming ................................................................................................................. 14 9 MJ transmitting unit diagnostics .................................................................................... 15 CONVENTIONS In this manual, all important information is indicated using the following symbols and con- ventions: : WARNINGS : INSTRUC- TIONS : TECHNICAL DATA : IMPORTANT TEXTS abcd.... ! abcd.... abcd....abcd.... THIS MANUAL REFERS EXCLUSIVELY TO THE TRANSMITTING UNIT: THE INSTAL- LATION WARNINGS ARE GIVEN IN THE RECEIVING UNIT MANUAL. BEFORE INSTALLING, STARTING AND USING THE RADIO REMOTE CONTROL, THIS MANUAL MUST BE READ AND UNDERSTOOD CAREFULLY BY ALL PEOPLE WHO INSTALL, USE AND CARRY OUT MAINTENANCE ON THE RADIO REMOTE CONTROL. Page 2 of 162 - IntroductionLIMJNMA0 English 2 INTRODUCTION Industrial radio remote controls of the Modular se- ries are used to command machines from a dis- tance. Each industrial radio remote control is made up of a portable transmitting unit, from which the user can remotely control the machine, and a re- ceiving unit installed on board the machine itself. The transmitting unit uses radio frequencies to transmit a coded message which contains a value called address. Each receiving unit can only de- code the messages coming from a transmitting unit with the same address. This excludes the possibility of an interference ac- tivating any system function. If the radio frequency transmission is disturbed, incorrect or interrupted, the receiving unit autonomously stops the whole system. Each Modular series radio remote control complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party re- sponsible for compliance could void the user’s authority to operate the equipment. Autec cannot be held responsible if the radio remote control is in- stalled on applications that are different from those permitted: PERMITTED USES Material lifting machines (construction cranes, industrial bridge cranes, machines for moving material in general, . . . ). FORBIDDEN USES Machines installed in areas where equipment with explosion-proof characteristics are being used. Machines for moving, raising and transporting people. Receiving unit Transmitting unit ! ! LIMJNMA02 - IntroductionPage 3 of 16 All machines must undergo a risk analysis; therefore it is necessary to evaluate, within the limits of this analysis, if the machine can be radio remote controlled. The machine producer and/or the person who decides upon radio remote control use and installation is responsible for this analysis. Autec cannot be held responsible if the risk analysis is not carried out correctly. To guarantee correct radio remote control operation, all current regulations regarding safety at work and accident prevention should be respected. All current user country national laws regarding the use of both the machine and the radio remote control MUST ALWAYS be respected. Autec cannot be held responsible if the radio remote control is used in unlawful working conditions. System must be installed by a licensed technician and in accordance with all rel- evant local, state/provincial and federal regulations, including but not limited to NEC, OSHA, CE etc. In any cases of emergencies, faults or damaged parts, ALWAYS stop the “machine + radio remote control” system until the problem has been solved. Any damaged parts can ONLY be replaced by authorised Autec personnel or service representative, and only using original Autec spare parts. ! Page 4 of 162 - IntroductionLIMJNMA0 English INSTRUCTIONS FOR DOCUMENT MANAGEMENT The following minimum documentation is supplied with each radio remote control: - transmitting unit manual - receiving unit manual - battery charger manual - a guarantee certificate - the radio remote control technical data sheet. Make sure that the following documents have been supplied: if they a…

Text truncated - open the document above for the full version.

ID Label/Location Info

RADIO MODULE.............................................E16STXUS1 FREQUENCY RANGE....................................902-928MHz POWER SUPPLY................................MBM06MH 7,2V PROTECTION DEGREE..............................................IP65 TYPE TF02MODEL B07D Technical Data TRANSMITTER TA901/0 - A0TARG01P0663 ------ FCC ID: OQA-TF02B07D This radio device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Operational Description

1 Operational Description for Type TF02 Model B07D transmitting unit Operational Description for Type TF02 Model B07D transmitting unit 1Identification of the unit where: TYPE: identifies type of unit (transmitting, receiving or transceiving), type of casing and used electronic modules. MODEL: differentiates power supply, type of actuators and radio frequency band CONFIGURATION: refersto the specific set of components and accessories of the unit TRADE NAME: commercial reference 2Difference between the units There are some Configurations which differ each other for the type of the actuators used in the unit: - Configuration M08 has 2 joystick type Gessmann with double contacts - Configuration M09 hasn’t joysticks (only toggle switch, pushbutton and rotary switch) - Configuration M10 has 2 joystick type Euchener - Configuration M11 has 3 joystick type Euchener - Configuration M12 has 2 joystick type Gessmann with single contacts Ty p eTF02 ModelB07D ConfigurationM08 Equipmentremote control transmitting unit Trasmitting radio moduleE16STXUS1 Used frequency band902 - 928 MHz Trade nameMJ FCC IdentifierOQA-TF02B07D Manufacturer AUTEC srl Via Pomaroli, 65 I-36030 CALDOGNO (VI) 2 Operational Description for Type TF02 Model B07D transmitting unit 3Operational description Industrial radio remote controls are used to command machines from a distance. Each industrial radio remote control is made up of a portable transmitting unit, from which the user can remotely control the machine, and a receiving unit installed on board the machine itself. The MJ transmitting unit is a handheld unit. The MJ contains E16STXUS1. It is the radio transmitting module. A logic section collects commands coming from various actuators (joysticks and or pushbut- tons and switches present in the E16SIC01A interface card ) and combines them with an address code stored an EEPROM memory ("address Key"); a serial data telegram at 2200- 2600 baud is so obtained. After a Gaussian spectrum shaping filter, the telegram is frequency modulated on a carrier generated by a PLL synthesizer and then trasmitted over a 25kHz channel in the 902-828 MHz band; 32 different frequencies my be chosen, so as to allow cohexistence of multiple units on the same location (for details see relative block diagrams). Transmission is continuous (100% duty cycle) even with no command activated, since the reciver is expected to monitor continuously the presence of a valid radio signal. A receiving unit will decode only messages coming from a transmitter with the same address code. This excludes the possibility of an interference activating any function unwantedly. Receiving unit Transmitting unit 3 Operational Description for Type TF02 Model B07D transmitting unit 4Exploded view 2 led card Casing E16STXUS1 transmitting module (contains encoder and radio transmitter) Joystick Gessmann V20 E16SIC01A interface card STOP pushbutton Keyswitch selector for powering the unit Pushbutton Joystick Euchner Rotative switch Antenna Toggle switch Toggle switch START pushbutton for starting the unit Pushbutton Address key (contains the address of the telegram) 4 Operational Description for Type TF02 Model B07D transmitting unit 5Technical data E16STXUS1 trasmitting radio module 6Power supply: MBM06MH battery pack MBM06MH batteries must only be recharged using MBC____ battery chargers. Use the battery until it is totally discharged (the led of the transmitting unit flashes quickly when the battery used is discharged). Used frequency band902 - 928 MHz Type of modulation2200 - 2600 Baud GFSK Channel spacing25 kHz Designation of emission (ITU code)16K5F1D Strenght fieldsee relative Test Report Duty cycle up to 100 % (continuous duty), depends on user’s need Duplex directionsimplex Antenna typededicated Data telegram132 bit Hamming distance> 8 Probability of non-recognition of error<10 exp-11 number of NiMH elements6 nominal voltage of 1 element (V)1,2 total nominal voltage of the battery (V)7,2 battery voltage after discharge (V)6 voltage of the charged battery (V)8,4 capacity (mAh)750 number of cycles in average life400 autonomy (hours)up to 15 recharge time (approx) 3

Test Report

FCC.TR. TEST REPORT 04.205 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 30/07/04 sheet 1 of 26 EQUIPMENT UNDER TEST : APPARECCHIO IN PROVA : MJ waist-portable unit with 2 joystick type Gessmann Type TF02, Model B07D, Configuration M08 DERIVED MODELS : APPARECCHI DERIVATI : Configuration M09 – M10 – M11 – M12 REFERENCE STANDARDS : NORME DI RIFERIMENTO : FCC 47 CFR Part 15 CUSTOMER: RICHIEDENTE: • Dept. / Firm : Ente / Società’: AUTEC S.r.l. • Mr.: Sig.: BIANCHIN STEFANO • Address: Indirizzo: VIA POMAROLI, 65 - 36030 CALDOGNO (VI) - ITALY • Tel. : Telefono : ++39 0444 901000 • Telefax Fax : ++39 0444 901080 • E-mail: e-mail [email protected] Site of test execution: Via Campagna, 92 - 22020 Gaggino Faloppio (CO) - Italy Località esecuzione prove: Date of test samples receipt: 26/05/04 Date of start test: 26/05/04 Data ricevimento campioni: Data inizio prove: Date of end test: 07/06/04 Data fine prove: Witness to the test: Presenti alle prove: Signature of the engineers: Firma esecutore prove: Signature of the Laboratory Director: Firma Direttore Laboratori: Nobody / Nessuno ......................................................... .......................................................... F. Barbierato .......................................................... R. Furfari The test results recorded in this Test Report are exclusively referred to the tested samples. I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. Reproduction of this EMC-Test Report in whole or in part is prohibited without the written authorization of the Laboratory Director La riproduzione di questo Rapporto in modo parziale o totale è PROIBITO senza l’autorizzazione scritta della Direzione del Laboratorio FCC.TR. TEST REPORT 04.205 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 30/07/04 sheet 2 of 26 0. CONTENTS Page Rev Date 0. CONTENTS ................................................................................................. 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ........ 1.1 Identification ......................................................................................... 1.2 Technical data ...................................................................................... 1.3 Transmitter technical data ................................................................... 1.4 Modifications incorporated in E.U.T...................................................... 1.5 Ports identification ................................................................................ 1.6 Auxiliary equipment .............................................................................. 2. TEST CONDITIONS .................................................................................... 2.1 Operating test modes and test conditions ............................................ 2.2 Test overview ....................................................................................... 3. REFERENCE STANDARD FOR PERFORMED TESTS ............................. 4. Summary of test results ............................................................................... 4.1 Tests..................................................................................................... 4.2 Emission limits...................................................................................... 5. TEST RESULTS .......................................................................................... 6. EUT TECHNICAL DOCUMENTATION........................................................ 6.1 Wiring diagrams.................................................................................... 6.2 Technical manual ................................................................................. 6.3 Photographic documentation ................................................................ 7. TECHNICAL REPORT OF ANALYSIS OF DERIVED PRODUCTS ............ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 30/07/04 FCC.TR. TEST REPORT 04.205 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Edition: 1.0 Issue date: 30/07/04 sheet 3 of 26 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) 1.1 Identification Brand name: AUTEC Equipment : MJ waist-portable unit with 2 joystick type Gessmann Model name or No. : Type TF02 Model B07D Serial number : Prototype FCC ID : OQA-TF02B07D Country of manufacturer: ITALY 1.2 Technical data FCC class: Intentional Radiators TX module type : E16STXUS1 Supply voltage: Custom NiMH Battery pack 7,2 Vdc 750mAh model MBM06MH Typical usage : Portable radio remote control used to command Industrial machines EUT single or system: Single EUT dimensions : 255 x 170 x 126 mm FCC.TR. TEST REPORT 04.205 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. F…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Antonio Silvestri(Director)
[email protected]+39-0444-901085Fax: +39-0444-901080

Test Firm

Prima Ricerca & Sviluppo S.r.l.Enrico Banfi
[email protected]39-031-3500011Fax: 39-031-991309

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.15 MHz - 927.725 MHz-
Confidentiality
Long Term

Other Applications from Autec s.r.l.

Transceiver Unit - FCC ID OQA-TM0N2EN0B3 - Autec s.r.l.
OQA-TM0N2EN0B3

Transceiver Unit

Jul 20, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Transceiver unit - FCC ID OQA-TX0N2BC0A3 - Autec s.r.l.
OQA-TX0N2BC0A3

Transceiver unit

Jul 09, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Transceiver unit - FCC ID OQA-TR0N2BC0Z3 - Autec s.r.l.
OQA-TR0N2BC0Z3

Transceiver unit

Jun 09, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Transceiver Unit - FCC ID OQA-FSAACT01A - Autec s.r.l.
OQA-FSAACT01A

Transceiver Unit

Mar 04, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Transceiver Unit - FCC ID OQA-AX0A02Z0W1 - Autec s.r.l.
OQA-AX0A02Z0W1

Transceiver Unit

Feb 24, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter