FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PAC International Limited/
  3. OQLGS3LFS

OQLGS3LFSStandard LF Reader GS3 OneProx

PAC International Limited
Standard LF Reader GS3 OneProx - FCC ID OQLGS3LFS - PAC International Limited
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 01, 2013
Application Purpose
Original Equipment
Date of Application
Aug 01, 2013
Equipment Note
Standard LF Reader GS3 OneProx
Frequency Range
0.12400000 - 0.12400000
Company
PAC International Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GS3-LF Mullion / Standard Reader Installation Guide 17998v3.02DRAFT60Jul2013 2 GS3-LFMullion/ StandardReader InstallationGuide GS3-LFMittelpfosten/ Standard Installationsanleitung GS3-LFLecteurProfilé/ Standard Guided’installation GS3-LFLectorColumelar/ Estándar Guíade instalación GS3-LFSpröjs/ Standard Installationsanvisninar GS3-LFMullion/ Standaard Installatiehandleiding GS3-LFPost / Standard Installasjonsguide GS3-LFStipite/ Standard Guidaall’installazione GS3-LFDe parede/ Standard Guiade Instalação GS3-LFPystykarmi/ Vakio Asennusopas 3 StandardReader· Standardleser· Lecteurstandard· Lectorestándar· Standardläsare· Standaardlezer · Standardleser · Lettorestandard· Leitorstandard· Vakiolukija P/N909020111 Parts· Teile · Pièces· Piezas· Delar · Delen· Deler · Componenti· Componentes· Osat ×4 ×1×1 MOV ×1×1 ×1 Dimensions· Ausmaße· Dimensions· Dimensiones· Mått · Afmetingen· Dimensjoner· Dimensioni· Dimensões· Mitat 20.05 13.75 11.5 85.25 11.5 9.97 40.05 60 82.5 110.5 115 89 28 Alldimensionsmm·AlleAusmaßeinmm·Toutesdimensionsenmm·Todaslasdimensiones enmm·Allamåttimm·Alleafmetingenmm·Alledimensjonerimm·Tutteledimensionisono inmm·Todasasdimensõesemmm·Kaikkimitatovatmm:nä 4 MullionReader· Mittelpfostenleser· Lecteurprofilé· Lectorcolumelar· Spröjsläsare· Mullionlezer · Postleser· Lettoreper stipite· Leitorde parede· Pystykarmilukija P/N909020110 Parts· Teile · Pièces· Piezas· Delar · Delen· Deler · Componenti· Componentes· Osat ×1 ×4 ×1×1×1 MOV ×1 Dimensions· Ausmaße· Dimensions· Dimensiones· Mått · Afmetingen· Dimensjoner· Dimensioni· Dimensões· Mitat 48 105 28 20 83 100.5 41.5 25 27.3 30 17.9 Alldimensionsmm·AlleAusmaßeinmm·Toutesdimensionsenmm·Todaslasdimensiones enmm·Allamåttimm·Alleafmetingenmm·Alledimensjonerimm·Tutteledimensionisono inmm·Todasasdimensõesemmm·Kaikkimitatovatmm:nä 5 Connections· Anschlüsse· Connexions· Conexiones· Anslutningar· Aansluitingen· Tilkoplingar· Connessioni· Ligações· Liitännät 12-24V D1/SIG LED 0V/GND D0/CLK T AMP SOUND +V/12V–24V D1/SIG LED 0V/GND D0/CLK Tamper·Sabotage·Effraction·Manip.fraud.·Manip.·Tamper·Sabotasje· Manomissione·Interferência·Ilkivalta Sounder·Signaltongeber·Alarmesonore·Sonido·Ljudsignal·Alarm·Sirene· Ricevitoreacustico·Dispositivoemissordesons·Äänimerkinantaja Donotuse·Nichtverwenden·N’utiliserpas·Noutilice·Användinte·Niet gebruiken·Ikkebruk·Nonusare·Nãoutilizar·Äläkäytä CableRouting· Kabelführung· Routagedu câble · Recorridodel cable · Kabeldragning· Kabelroute· Kabelføring· Percorsodei cavi · Encaminhamentode cabos· Kaapelireititys 6 OutputFormat·Ausgabeformat·FormatdeSortie·FormatodeSalida· Utdataformat·Uitvoerformaat·Utdataformat·Formatouscita·Formato de saída · Lähtömuoto DefaultSettings· Standardeinstellungen· Paramètresstandards· Ajustesestándares· Standardinställningar· Standaardinstellingen· Standardinnstillinger· Impostazioni standard· Configuraçõespadrões· Oletusasetukset OutputFormat Ausgabeformat Formatde sortie Formatode Salida Utdataformat Uitvoerformaat Utdataformat Formatouscita Formatode saída Lähtömuoto Card / Token Karten/ Token Carte/ Fiche Tarjeta/ Ficha Kort / Nyckel Kaart/ Penning Kort / Nøkkel Scheda/ Contrassegno Cartão/ Token Kortti/ Rahake DIP PAC ON 12345 PAC/KeyPAC WiegandProx PAC64 ON 12345 PAC/KeyPAC WiegandProx Magstripe ON 12345 PAC/KeyPAC WiegandProx 7 OtherSettings· AndereEinstellungen· Autresparamètres· Otrosajustes· Övriga inställningar· Andereinstellingen· Andreinnstillinger· Altre impostazioni· Outras configurações· Muut asetukset OutputFormat Ausgabeformat Formatde sortie Formatode Salida Utdataformat Uitvoerformaat Utdataformat Formatouscita Formatode saída Lähtömuoto Card / Token Karten/ Token Carte/ Fiche Tarjeta/ Ficha Kort / Nyckel Kaart/ Penning Kort / Nøkkel Scheda/ Contrassegno Cartão/ Token Kortti/ Rahake DIP Wiegand26-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand34-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand74-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand74-bit ON 12345 PAC/KeyPAC WiegandWiegandProx 8 Symbols· Symbole· Symboles· Símbolos· Symboler· Symbolen· Symboler· Simboli· Símbolos· Symbolit Datafromcard·DatenvonKarte·Lesdonnéesdelacarte·Losdatosdetarjeta· Datafrånkortet·Gegevensvandekaart·Datafrakortet·Datidallascheda·Os dadosdocartão·Tiedotkortti Paddedortruncateddata·Datenaufgefülltoderabgeschnitten·Lesdonnéessont complétéesoutronquées·Losdatosserellenanosetruncan·Datautfyllseller trunkeras·Gegevenswordenopgevuldofafgekapt·Datapolstreselleravkortes· Datisonoimbottitiotroncati·Osdadossãopreenchidosoutruncados·Tiedoton pehmustettutaikatkaistu Processeddata·Datenverarbeitet·Lesdonnéessonttraitées·Losdatosse procesan·Databearbetas·Gegevenswordenverwerkt·Databehandles·Dati sonotrattati·Osdadossãoprocessados·Tiedotkäsitellään OPSprocesseddata·DatenverarbeitetalsOPS·Lesdonnéessonttraitéescomme OPS·LosdatosseprocesancomoOPS·DatabearbetassomOPS·Gegevens wordenalsOPSverwerkt·DatabehandlessomOPS·DatisonotrattaticomeOPS· OsdadossãoprocessadoscomoOPS·Tiedotkäsitelläänjasalauspuretaan 9 ReaderConfiguration· Konfigurationdes Lesers· Configurationdu lecteur· Configuraciónde lector· Läsarenskonfigurering· Lezerconfiguratie· Leserkonfigurasjon· Configurazionedel lettore· Configuraçãodo leitor · Lukijankonfiguraatio Result· Ergebnis· Résultat· Resultado· Resultat· Resultaat· Resultat· Risultato· Resultado· Tulos DIP Readerbeepswhentokenpresented DerLeserpiept,wenneinTokenvorgezeigtwird. Lelecteurémetunbiplorsquelaficheestprésenté Lectorpitacuandounatarjetaespresentada Läsarenpipernärnyckelvisas Lezerpieptalseentokenwordtaangeboden Leserenpipernårsymboletvises Illettoreemetteunsegnaleacusticoquandovienepresentatoilcontrassegno Oleitoremitesinaissonorosquandootokenéapresentado Lukijapiippaalaitettaessarahakelaitteeseen ON 12345 Readersilentwhentokenpresented DerLeserbleibtstumm,wenneinTokenvorgezeigtwird. Lelecteurrestesilencieuxlorsquelaficheestprésenté Lectorsilenciacuandounatarjetaespresentada Läsarenärtystnärnyckelvisas Lezerstilalseentokenwordtaangeboden Leserenerstillenårsymboletvises Illettoreèsil…

Text truncated - open the document above for the full version.

Users Manual

GS3-LF Mullion / Standard Reader Installation Guide 17998v3.03DRAFT62Jul2013 2 GS3-LFMullion/ StandardReader InstallationGuide GS3-LFLecteurProfilé/ Standard Guided’installation GS3-LFLectorColumelar/ Estándar Guíadeinstalación 3 StandardReader· Lecteurstandard· Lectorestándar P/N909070111 Parts· Pièces· Piezas ×4 ×1×1 MOV ×1×1 ×1 Dimensions· Dimensions· Dimensiones 20.05 13.75 11.5 85.25 11.5 9.97 40.05 60 82.5 110.5 115 89 28 Alldimensionsmm·Toutesdimensionsenmm·Todaslasdimensionesenmm 4 MullionReader· Lecteurprofilé· Lectorcolumelar P/N909070110 Parts· Pièces· Piezas ×1 ×4 ×1×1×1 MOV ×1 Dimensions· Dimensions· Dimensiones 48 105 28 20 83 100.5 41.5 25 27.3 30 17.9 Alldimensionsmm·Toutesdimensionsenmm·Todaslasdimensionesenmm 5 Connections· Connexions· Conexiones 12-24V D1/SIG LED 0V/GND D0/CLK T AMP SOUND +V/12V–24V D1/SIG LED 0V/GND D0/CLK Tamper·Effraction·Manip.fraud. Sounder·Alarmesonore·Sonido Donotuse·N’utiliserpas·Noutilice CableRouting· Routagedu câble · Recorridodel cable 6 OutputFormat· Formatde Sortie· Formatode Salida DefaultSettings· Paramètresstandards· Ajustesestándares OutputFormat Formatde sortie Formatode Salida Card / Token Carte/ Fiche Tarjeta/ Ficha DIP Wiegand74-bit ON 12345 PAC/KeyPAC WiegandWiegandProx Wiegand34-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand26-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand74-bit ON 12345 PAC/KeyPAC WiegandProx OtherSettings· Autresparamètres· Otrosajustes OutputFormat Formatde sortie Formatode Salida Card / Token Carte/ Fiche Tarjeta/ Ficha DIP Magstripe ON 12345 PAC/KeyPAC WiegandProx PAC ON 12345 PAC/KeyPAC WiegandProx PAC64 ON 12345 PAC/KeyPAC WiegandProx 7 Symbols· Symboles· Símbolos Datafromcard·Lesdonnéesdelacarte·Losdatosdetarjeta Paddedortruncateddata·Lesdonnéessontcomplétéesoutronquées·Losdatos serellenanosetruncan Processeddata·Lesdonnéessonttraitées·Losdatosseprocesan OPSprocesseddata·LesdonnéessonttraitéescommeOPS·Losdatosseprocesan comoOPS ReaderConfiguration· Configurationdu lecteur· Configuraciónde lector Result· Résultat· ResultadoDIP Readerbeepswhentokenpresented Lelecteurémetunbiplorsquelaficheestprésenté Lectorpitacuandounatarjetaespresentada ON 12345 Readersilentwhentokenpresented Lelecteurrestesilencieuxlorsquelaficheestprésenté Lectorsilenciacuandounatarjetaespresentada ON 12345 8 English Installation 1. Ensureyourproductcomeswiththeitemsindicatedonpages4–5;ifnotplease contactyourdealer. 2. Feedcablesthroughbackplate. 3. Usetwoscrewstoattachbackplatetowall. 4. Usetwoscrewstoattachtamperplatetowall. 5. Connectcabletocircuitboard—seepage6. 6. Setoutputformat—seepage7. 7. Configurereader—seepage8. 8. Snapreadertobackplateandsecurewithfinalscrew. 9. Applypowerwhenallreadersareinstalled. Notes • Ifpowerisappliedwhenthereaderisnotproperlyattachedtothewall,awall tamperconditionisgenerated. • Donotdistortthebackplateortamperplatewhenmounting,e.g.toabackbox, oraspuriouswalltamper/casetamperconditionmaybegenerated. • Mount readers >3′ / 1m apart, e.g. on either side of the door. Mounting on metal surfaces will reduce the reading range. • If the reader is being used to enter credential information to arm a system, the reader must be located within 3′ / 1m of the panel’s main keypad or display. • Foroutsidereaders,usecorrosion-resistantfixingsandapplysiliconesealantto thebackplatebeforefixingtothewall. • ThesuppliedMOV(MetalOxideVaristor,AngliaComponentsP/NB72207S250K101) shouldbefittedacrossthepowerterminalsofthelocktosuppressbackEMF.Any suppressiondiodesfittedinthelock/lockcircuitmustberemoved. • Outputformatandreaderconfigurationcanbechangedwithoutdisconnectingthe powersupply.Thereaderautomaticallyrestartswiththenewconfiguration. 9 English ReaderTamper Ifthebackplateispulledawayfromthewall,thetamperplateremainsattachedtothewall andawall tamperconditionisgenerated.Likewise,ifthereaderisremovedfromthebackplate, acase tamperconditionisgenerated. ThevoltageontheTamperlineisnormallylow.Ifcasetamperorwalltamperisdetected,the voltageontheTamperlinebecomeshighandthereadersounds3longbeepsevery5seconds fortwominutes,thenstops. Toclearawalltampercondition,reattachthebackplatetothetamperplate.Toclearacase tampercondition,reattachthereadertothebackplate. Usage LEDs YellowRed / GreenGreenRed ArmingsystemAccessdeniedAccesspermittedDefault Sounder • Thereadersounds4rapidbeepswhenitispowereduporrestarted. • Ifspecified,thereaderbeepsoncewhenatokenispresented. CableLengths Sonitroldoorcontrollersonly Distancefrom Readerto ControllerCableGauge 230′ / 70m *7/0.20.34mm²22AWG 230′ / 70m *16/0.20.5mm²20AWG 230′ / 70m *32/0.21.0mm²18AWG 10 English Notes • These figures (*) are for readers powered from the controller. The cable distances can be increased to 1650′ / 500m by locally powering the readers. • LocallypoweredreadersmustbeconnectedtoaUL603powerlimitedClass2 supplyforUS,oraULCS318powerlimitedClass2supplyforCanada. • Ifyouuse22AWG/0.34mm²cables,twistthewiresanddoublethemoverbefore insertingtheminthecrimps. • Maximumcabledistanceswillbelessforreaderswhichhavebeensettogive Wiegandoutput. Specification CurrentPowerReaderRange 100mA(Mullion)/120mA (Standard) 12V–24VDCUp to 4.0′′ / 100mm Note Maximumcurrentdrawislowerat24V. Temperature StorageOperating -40°C—+66°C/-40°F—+151°F-40°C—+66°C/-40°F—+151°F Humidity Operatingfor 24 hours Testedat93%forULCS319.10-85%RH@30±2°C/85±4°F IngressProtection IP65afterinstallation—evaluatedbylabseparatefromUL.Installermustadequatelysealany connectionsmade. Weight 150g(Mullion)/290g(Standard) 11 English Français Installation 1. Vérifierquevotreproduitcontienttouteslesarticlesindiquésàlespages4–5.Encas depiècemanquante,contactervotredistributeur. 2. Passerlescâblesàtraverslesupportdefixation. 3. Utiliserdeuxvispourfixerlesupportdefixationaumur. 4. Utiliserdeuxvispourfixerlesupportd’autoprotectionaumur. 5. Raccorderlecâbleaucircuit—voirpage6. 6. Sélectionnerleformatdesortie—voirpage7. 7. Configurerlelecteur—voirpage8. 8. Fixerfermementlelecteuràsonsupportdefixationetassurerlafixationavecladernière vis. 9. Alimente…

Text truncated - open the document above for the full version.

Users Manual

GS3-LF Mullion / Standard Reader Installation Guide 17998v3.01DRAFT61Jul2013 2 GS3-LFMullion/ StandardReader InstallationGuide GS3-LFMittelpfosten/ Standard Installationsanleitung GS3-LFLecteurProfilé/ Standard Guided’installation GS3-LFLectorColumelar/ Estándar Guíade instalación GS3-LFSpröjs/ Standard Installationsanvisninar GS3-LFMullion/ Standaard Installatiehandleiding GS3-LFPost / Standard Installasjonsguide GS3-LFStipite/ Standard Guidaall’installazione GS3-LFDe parede/ Standard Guiade Instalação GS3-LFPystykarmi/ Vakio Asennusopas 3 StandardReader· Standardleser· Lecteurstandard· Lectorestándar· Standardläsare· Standaardlezer · Standardleser · Lettorestandard· Leitorstandard· Vakiolukija P/N909028111 Parts· Teile · Pièces· Piezas· Delar · Delen· Deler · Componenti· Componentes· Osat ×4 ×1×1 MOV ×1×1 ×1 Dimensions· Ausmaße· Dimensions· Dimensiones· Mått · Afmetingen· Dimensjoner· Dimensioni· Dimensões· Mitat 20.05 13.75 11.5 85.25 11.5 9.97 40.05 60 82.5 110.5 115 89 28 Alldimensionsmm·AlleAusmaßeinmm·Toutesdimensionsenmm·Todaslasdimensiones enmm·Allamåttimm·Alleafmetingenmm·Alledimensjonerimm·Tutteledimensionisono inmm·Todasasdimensõesemmm·Kaikkimitatovatmm:nä 4 MullionReader· Mittelpfostenleser· Lecteurprofilé· Lectorcolumelar· Spröjsläsare· Mullionlezer · Postleser· Lettoreper stipite· Leitorde parede· Pystykarmilukija P/N909028110 Parts· Teile · Pièces· Piezas· Delar · Delen· Deler · Componenti· Componentes· Osat ×1 ×4 ×1×1×1 MOV ×1 Dimensions· Ausmaße· Dimensions· Dimensiones· Mått · Afmetingen· Dimensjoner· Dimensioni· Dimensões· Mitat 48 105 28 20 83 100.5 41.5 25 27.3 30 17.9 Alldimensionsmm·AlleAusmaßeinmm·Toutesdimensionsenmm·Todaslasdimensiones enmm·Allamåttimm·Alleafmetingenmm·Alledimensjonerimm·Tutteledimensionisono inmm·Todasasdimensõesemmm·Kaikkimitatovatmm:nä 5 Connections· Anschlüsse· Connexions· Conexiones· Anslutningar· Aansluitingen· Tilkoplingar· Connessioni· Ligações· Liitännät 12-24V D1/SIG LED 0V/GND D0/CLK T AMP SOUND +V/12V–24V D1/SIG LED 0V/GND D0/CLK Tamper·Sabotage·Effraction·Manip.fraud.·Manip.·Tamper·Sabotasje· Manomissione·Interferência·Ilkivalta Sounder·Signaltongeber·Alarmesonore·Sonido·Ljudsignal·Alarm·Sirene· Ricevitoreacustico·Dispositivoemissordesons·Äänimerkinantaja Donotuse·Nichtverwenden·N’utiliserpas·Noutilice·Användinte·Niet gebruiken·Ikkebruk·Nonusare·Nãoutilizar·Äläkäytä CableRouting· Kabelführung· Routagedu câble · Recorridodel cable · Kabeldragning· Kabelroute· Kabelføring· Percorsodei cavi · Encaminhamentode cabos· Kaapelireititys 6 OutputFormat·Ausgabeformat·FormatdeSortie·FormatodeSalida· Utdataformat·Uitvoerformaat·Utdataformat·Formatouscita·Formato de saída · Lähtömuoto DefaultSettings· Standardeinstellungen· Paramètresstandards· Ajustesestándares· Standardinställningar· Standaardinstellingen· Standardinnstillinger· Impostazioni standard· Configuraçõespadrões· Oletusasetukset OutputFormat Ausgabeformat Formatde sortie Formatode Salida Utdataformat Uitvoerformaat Utdataformat Formatouscita Formatode saída Lähtömuoto Card / Token Karten/ Token Carte/ Fiche Tarjeta/ Ficha Kort / Nyckel Kaart/ Penning Kort / Nøkkel Scheda/ Contrassegno Cartão/ Token Kortti/ Rahake DIP PAC ON 12345 PAC/KeyPAC WiegandProx PAC64 ON 12345 PAC/KeyPAC WiegandProx Magstripe ON 12345 PAC/KeyPAC WiegandProx 7 OtherSettings· AndereEinstellungen· Autresparamètres· Otrosajustes· Övriga inställningar· Andereinstellingen· Andreinnstillinger· Altre impostazioni· Outras configurações· Muut asetukset OutputFormat Ausgabeformat Formatde sortie Formatode Salida Utdataformat Uitvoerformaat Utdataformat Formatouscita Formatode saída Lähtömuoto Card / Token Karten/ Token Carte/ Fiche Tarjeta/ Ficha Kort / Nyckel Kaart/ Penning Kort / Nøkkel Scheda/ Contrassegno Cartão/ Token Kortti/ Rahake DIP Wiegand26-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand34-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand74-bit ON 12345 PAC/KeyPAC WiegandProx Wiegand74-bit ON 12345 PAC/KeyPAC WiegandWiegandProx 8 Symbols· Symbole· Symboles· Símbolos· Symboler· Symbolen· Symboler· Simboli· Símbolos· Symbolit Datafromcard·DatenvonKarte·Lesdonnéesdelacarte·Losdatosdetarjeta· Datafrånkortet·Gegevensvandekaart·Datafrakortet·Datidallascheda·Os dadosdocartão·Tiedotkortti Paddedortruncateddata·Datenaufgefülltoderabgeschnitten·Lesdonnéessont complétéesoutronquées·Losdatosserellenanosetruncan·Datautfyllseller trunkeras·Gegevenswordenopgevuldofafgekapt·Datapolstreselleravkortes· Datisonoimbottitiotroncati·Osdadossãopreenchidosoutruncados·Tiedoton pehmustettutaikatkaistu Processeddata·Datenverarbeitet·Lesdonnéessonttraitées·Losdatosse procesan·Databearbetas·Gegevenswordenverwerkt·Databehandles·Dati sonotrattati·Osdadossãoprocessados·Tiedotkäsitellään OPSprocesseddata·DatenverarbeitetalsOPS·Lesdonnéessonttraitéescomme OPS·LosdatosseprocesancomoOPS·DatabearbetassomOPS·Gegevens wordenalsOPSverwerkt·DatabehandlessomOPS·DatisonotrattaticomeOPS· OsdadossãoprocessadoscomoOPS·Tiedotkäsitelläänjasalauspuretaan 9 ReaderConfiguration· Konfigurationdes Lesers· Configurationdu lecteur· Configuraciónde lector· Läsarenskonfigurering· Lezerconfiguratie· Leserkonfigurasjon· Configurazionedel lettore· Configuraçãodo leitor · Lukijankonfiguraatio Result· Ergebnis· Résultat· Resultado· Resultat· Resultaat· Resultat· Risultato· Resultado· Tulos DIP Readerbeepswhentokenpresented DerLeserpiept,wenneinTokenvorgezeigtwird. Lelecteurémetunbiplorsquelaficheestprésenté Lectorpitacuandounatarjetaespresentada Läsarenpipernärnyckelvisas Lezerpieptalseentokenwordtaangeboden Leserenpipernårsymboletvises Illettoreemetteunsegnaleacusticoquandovienepresentatoilcontrassegno Oleitoremitesinaissonorosquandootokenéapresentado Lukijapiippaalaitettaessarahakelaitteeseen ON 12345 Readersilentwhentokenpresented DerLeserbleibtstumm,wenneinTokenvorgezeigtwird. Lelecteurrestesilencieuxlorsquelaficheestprésenté Lectorsilenciacuandounatarjetaespresentada Läsarenärtystnärnyckelvisas Lezerstilalseentokenwordtaangeboden Leserenerstillenårsymboletvises Illettoreèsil…

Text truncated - open the document above for the full version.

Cover Letter(s)

Christopher Harris Security Compliance Officer Stanley Convergent Security Solutions, Inc. 1707 Orlando Central Parkway, Ste. 500 Orlando, FL 32809  tel +1-407-438-4445x4010  www.stanleycss.com June 12, 2013 Intertek 1365 Adams Ct. Menlo Park, CA 94025 To Whom It May Concern: Intertek is authorized to act on our behalf for the submission of Oneprox GS3-LF Standard, until otherwise notified, for application to Intertek. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Sincerely, Christopher Harris Security Compliance Officer

Cover Letter(s)

Christopher Harris Security Compliance Officer Stanley Convergent Security Solutions, Inc. 1707 Orlando Central Parkway, Ste. 500 Orlando, FL 32809  tel +1-407-438-4445x4010  www.stanleycss.com June 12, 2013 FCC ID: OQLGS3LFS Request for Confidentiality In accordance with 47 C.F.R. Section .0459, we, Stanley Security Solutions, hereby request confidentiality for the following items:  Electrical Schematic  Block Diagram  Theory of Operation/Technical Description  Internal Photographs  Bill of Materials/Parts List Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. Christopher Harris Stanley Convergent Security Solutions, Inc. Security Compliance Officer

ID Label/Location Info

LF Standard Reader

Test Report

TEST REPORT Report Number: 100687320MIN-001B Project Number: G100687320 Testing performed on the Oneprox GS3-LF Standard FCC ID: OQLGS3LFS Industry Canada ID: 7309A-OQLGS3LFS to 47 CFR Part 15.209; Part 15.215:2010 RSS- Gen, Issue 3, 2010 For Stanley Convergent Security Solutions, Inc. Test Performed by: Test Authorized by: Intertek Testing Services NA, Inc. 7250 Hudson Blvd., Suite 100 Oakdale, MN 55128 USA Stanley Convergent Security Solutions, Inc. 1707 Orlando Central Parkway, Suite 500 Orlando, FL 32809, USA Prepared by: Date: June 28, 2013 Uri Spector Reviewed by: Date: June 28, 2013 Simon Khazon This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. EMC Report No: 100687320MIN-001B FCC ID: OQLGS3LFS IC ID: 7309A- OQLGS3LFS Page 2 of 20 TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION.......................................................................................................... 3 1.1 Product Description; Test Facility ....................................................................................... 4 1.3 Environmental conditions.................................................................................................... 5 1.4 Measurement uncertainty ................................................................................................... 6 1.5 Field Strength Calculation................................................................................................... 6 2.0 TEST SUMMARY.......................................................................................................................... 7 3.0 TEST CONDITIONS AND RESULTS........................................................................................ 8 3.1 Field Strength of Fundamental and Spurious Emissions ................................................... 8 3.2 Bandwidth of Emissions.................................................................................................... 12 3.3 Transmitter power line conducted emissions ................................................................... 15 3.4 Receiver/digital device radiated emissions....................................................................... 18 3.5 Digital device conducted emissions.................................................................................. 19 4.0 TEST EQUIPMENT..................................................................................................................... 20 EMC Report No: 100687320MIN-001B FCC ID: OQLGS3LFS IC ID: 7309A- OQLGS3LFS Page 3 of 20 1.0 GENERAL DESCRIPTION Model: Oneprox GS3-LF Standard Type of EUT: Standard LF Card Reader Intertek Sample ID: MIN1306100958-004 FCC ID: OQLGS3LFS Industry Canada ID: 7309A-OQLGS3LFS Related Submittal(s) Grants: None Company: Stanley Convergent Security Solutions, Inc. Customer: Mr. Christopher Harris Address: 1707 Orlando Central Parkway, Suite 500 Orlando, FL 32809 Phone: (407) 206-7415 Fax: (866) 716-9006 e-mail: [email protected] Test Standards: 47 CFR, Part 15:2010, §15.209, §15.215 RSS–210, Issue 8, 2010 RSS-Gen, Issue 3, 2010 47 CFR, Part 15:2010, §15.107 and §15.109, Class ICES-003, Issue 4:2004 Other Type of radio: Stand -alone Module Hybrid Date Sample Submitted: June 10, 2013 Test Work Started: June 10, 2013 Test Work Completed: June 28, 2013 Test Sample Conditions: Damaged Poor (Usable) Good EMC Report No: 100687320MIN-001B FCC ID: OQLGS3LFS IC ID: 7309A- OQLGS3LFS Page 4 of 20 1.1 Product Description; Test Facility Product Description: SGR Standard LF Reader Operating Frequency 123.81kHz Modulation: ASK Emission Designator: 2K7A1D Antenna(s) Info: Integral antenna Antenna Installation: User Professional Factory Transmitter power configuration: Internal battery External power source 120VAC 230VAC 400VAC VDC Other: Amp. 50Hz 60Hz Special Test Arrangement: The transmitter was tested while connected to the SGR 512 Controller and was powered SGR 512 Controller. Conducted Emissions testing was performed at the SGR 512 Controller AC port. Test Facility Accreditation: A2LA (Certificate No. 1427.01) Test Methodology: Measurements performed according to the procedures in ANSI C63.10- 2009 EMC Report No: 100687320MIN-001B FCC ID: OQLGS3LFS IC ID: 7309A- OQLGS3LFS Page 5 of 20 1.2 EUT Configuration The equipment under test was operated during the measurement under the following conditions: - Standby - Continuous - Continuous un-modulated - Test program (customer specific) - Below Operating modes of the EUT: No. Description 1 The transmitter was set to transmit continuously. Cables: No. Type Length Designation Note 1 Communication cable 1m Reader cable, not shielded Support equipment/Services: No. Item Description 1 512 Controller General notes: Standard LF card reader is transmitter only, and has no receiver portion. 1.3 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 86-106 kPa EMC Report No: 100687320MIN-001B FCC ID: OQLGS3LFS IC ID: 7309A- OQLGS3LFS Page 6 of 20 1.4 Measurement uncertainty The expanded uncertainty (k = 2) for radiated e…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shaun C Byrne(Controller Team Leader)
[email protected]+44 161 4063440Fax: +44 161 430 8658

Technical Contact

Stanley Security Solutions, Ltd.Paul Lucas
[email protected]44 161 406 3429

1 Park Gate Close. Bredbury Parkway · Stockport · United Kingdom

Non-Technical Contact

Stanley Security Solutions, Ltd.Christopher L. Harris
[email protected]407-206-7415

Test Firm

Intertek Testing Services NA, Inc.Andrew Waytulonis
[email protected]651-730-1188Fax: 651 702 9132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.124 MHz - 0.124 MHz-
Confidentiality
Long Term

Other Applications from PAC International Limited

Panel LF Reader GS3 OneProx - FCC ID OQLGS3LFP - PAC International Limited
OQLGS3LFP

Panel LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Vandal LF Reader GS3 OneProx - FCC ID OQLGS3LFV - PAC International Limited
OQLGS3LFV

Vandal LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Admin MT Reader GS3 OneProx - FCC ID OQLGS3MTA - PAC International Limited
OQLGS3MTA

Admin MT Reader GS3 OneProx

Jul 31, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PIN MT Reader GS3 OneProx - FCC ID OQLGS3PIN - PAC International Limited
OQLGS3PIN

PIN MT Reader GS3 OneProx

Jul 30, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Standard MT Reader GS3 OneProx - FCC ID OQLGS3MTS - PAC International Limited
OQLGS3MTS

Standard MT Reader GS3 OneProx

Jul 30, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter