Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MD212 www.microlab.cn Microlab Electronics Company Ltd. Made in China © 2012 All rights reserved Disclaimer: All symbols and logos belong to the respective brand holder or registered holder. All specifications and information are subject to changes without further notice. Slight variations and differences might appear between the printed photos and actual product due to product enhancement. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Microlab Electronic Co., Ltd is under license. other trademarks and trade names are those of their respective owners. QDID: B019889 80-MD220-97-0001-01 2012-02-07 80-MD212-97-0001-01 2012-11-12 Caution: To reduce the risk of electric shock, do not dismantle the product and do not expose the apparatus to rain or moisture. No user-serviceable parts inside. Refer servicing to qualified personnel only. Explanation of Graphical Symbols: The lightning flash within an equilateral triangle is intended to alert you to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute an electric shock to a person or persons. The exclamation point within an equilateral triangle is intended to alert you to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. English 2 WARNINGS: 1. Read Instructions - All the safety and operating instructions must be read before the product is operated. 2. Retain Instructions - The safety and operating instructions should be kept with the product for future reference. 3. Heed warnings - All warnings on the product and in the operating instructions should be adhered to. 4. Follow instructions - All operating and users instructions should be followed. 5. Installation - Install in accordance with the manufacturer's instructions. 6. Power sources - This product should be operated only from the type of power source indicated by the marking adjacent to the power cord entry. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. 7. Grounding or polarization - the product is not required to be grounded. Ensure the plug is fully inserted into the wall outlet or extension cord receptacle to prevent blade or pin exposure. Some versions of the product are equipped with a power cord fitted with a polarized alternating line plug (a plug having one blade wide than the other). This plug will fit onto the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug. When using an extension power-supply cord or a power-supply cord other than that supplied with the product, it should be fitted with the appropriate molded plugs and carry safety approval appropriate to the country of use. 8. Power cord protection - Power-supply cords should be routed so that they are not likely to be walked on, kinked or pinched by items placed on or against them, paying particular attention to cords from plugs, receptacles and the point where they exit from the appliance. 9. Overloading - Do not overload wall outlets, extension cords or multiple sockets, as this can result in a risk 80-MD220-97-0001-01 2012-02-07 80-MD212-97-0001-01 2012-11-12 of fire or electric shock. 10. Ventilation - The product must be properly ventilated. Do not place the product on a bed, sofa, or other similar surface. Do not cover the product with any items such as tablecloths, newspapers, etc. 11. Heat - The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products including amplifiers that produce heat. No naked flame sources, such as lighted candles, should be placed on the apparatus. 12. Water and moisture - To reduce the risk of fire or electric shock, do not expose the product to train, dripping, splashing or excessive moisture such as in a sauna or bathroom. Do not use this product near water, for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, or etc. 13. Object and Liquid Entry - Never push objects of any kind into this product through openings, as they may touch dangerous voltage points or short-circuit parts that could result in a fire or electric shock. Never spill liquid of any kind on the product. Do not place any object containing liquid on top of the product. 14. Cleaning - Unplug the product from the wall outlet before cleaning. The cabinet of the subwoofer may be cleaned by dusting with a dry cloth. If you wish to use an aerosol cleaning spray, do not spray directly on the cabinet; spray onto the cloth. Be careful not to damage the drive units. 15. Attachments - Do not use attachments not recommended by the product manufacturers, as they may cause hazards. 16. Accessories - Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket or table recommended by the manufacturer or sold with the product. Any mounting of the product should follow the manufacturers’ instructions and should use a mounting accessory recommended by the manufacturer. 17. Moving the product - A product and cart combination should be moved with care. Quick stops, excessive force and uneven surfaces may cause the product and cart combination to overturn. 18. Un-use periods - The power cord of the device should be unplugged from the outlet during lightning storms or when the apparatus is left unused for a long period of time. 19. Servicing - Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage or oth…
Text truncated - open the document above for the full version.
Microlab Electronics Co., Ltd Nov 20, 2012 To: SIEMIC, INC. 775 Montague Expressway Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, ______Microlab El ectronics C o., Ltd ___hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Description: MULTIMEDIA SPEAKER Model name: MD212 FCC ID: OR8-MD212 We affirm that between SIEMIC and _ Microlab E lectronics C o., Ltd __, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities.
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Microlab Electronics Co., Ltd Nov 20, 2012 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: OR8-MD212 We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature : Client’s name / title : Xueyuan Bai / Manager Contact information / address: South Baozi Rd, Shenzhen Microlab Industrial Park, 518122, Shenzhen, China
Microlab MULTIMEDIA SPEAKER FCC ID: OR8-MD212 USB: 5V 500mA This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device
Antenna
FCC ID : OR8-MD212 1. RF EXPOSURE 1.1. The Requirement System operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. See Section 15.247(b)(4) and Section 1.1307(b)(1) 1.2. Limit For Maximum Permissible Exposure (MPE) Limits for General Population/ Uncontrolled Exposure F = frequency in MHz, * Plane-wave equivalent power density 1.3. MPE Calculations E(V/m) = 30 P G d , Power Density: S( 2 mW/cm) = 2 377 E Where E = Electric Field (V/m) P = Peak Output Power (mW) Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) ( 2 mW/cm) Averaging Time 2 E, 2 H or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100,000 1.0 30 G = Antenna Numeric Gain (numeric) = 10 x , x = Antenna Gain(dBi) /10 d = Separation Distance (cm) We can change the formula to: S = 2 30 377 PG d or, d = 30 377 PG S Because the EUT is belong to general population/uncontrolled exposure. So 1.3.1. We considering the limit of minimum separation distance (d) is 20cm, Maximum Output Power = 0.675mW Antenna Gain = 2.5(dBi) = 1.78(numeric) S = 2 30 377 PG d = 0.00024 2 mW/cm < 1.0 2 mW/cm (limit) Calculated RF Exposure power density is 0.00024 2 mW/cm , less than the limit. 1.3.2. We considering the limit of power density (S) is 1.0 2 mW/cm , Maximum Output Power = 0.675mW Antenna Gain = 2.5(dBi) = 1.78(numeric) d = 30 377 PG S = 0.31 cm < 20 cm Calculated RF Exposure separation distance is 0.35 cm, less than the minimum separation distance 1.3.3.FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, Human proximity to the antenna shall not be less than 20cm(8 inches) during normal operation. Proposed RF exposure safety information to include in User’s Manual.
Page 1 of 80 FCC ID: OR8-MD212 ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20122628 APPLICATION CERTIFICATION On Behalf of Microlab Electronics Co.,Ltd. MULTIMEDIA SPEAKER Model No.: MD212 FCC ID: OR8-MD212 Prepared for : Microlab Electronics Co., Ltd. Address : South Baozi Rd.,Shenzhen MicrolabIndustrial Park, 518122, ShenZhen, China Prepared by : ACCURATE TECHNOLOGY CO. LTD Address : F1, Bldg. A, Changyuan New Material Port, Keyuan Rd. Science & Industry Park, Nanshan, Shenzhen, Guangdong P.R. China Tel: (0755) 26503290 Fax: (0755) 26503396 Report Number : ATE20122628 Date of Test : Nov 17-Nov 30, 2012 Date of Report : Nov 30, 2012 Page 2 of 80 FCC ID: OR8-MD212 ACCURATE TECHNOLOGY CO. LTD REPORT NO. ATE20122628 TABLE OF CONTENTS Description Page Test Report Certification 1. GENERAL INFORMATION .......................................................................................................... 5 1.1. Description of Device (EUT)....................................................................................................................5 1.2. Description of Test Facility ......................................................................................................................6 1.3. Measurement Uncertainty.........................................................................................................................6 2. MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 7 3. OPERATION OF EUT DURING TESTING ................................................................................. 8 3.1. Operating Mode ........................................................................................................................................8 3.2. Configuration and peripherals ..................................................................................................................8 4. TEST PROCEDURES AND RESULTS ......................................................................................... 9 5. 20DB BANDWIDTH TEST............................................................................................................ 10 5.1. Block Diagram of Test Setup..................................................................................................................10 5.2. The Requirement For Section 15.247(a)(1) ............................................................................................10 5.3. EUT Configuration on Measurement .....................................................................................................10 5.4. Operating Condition of EUT ..................................................................................................................10 5.5. Test Procedure ........................................................................................................................................11 5.6. Test Result ..............................................................................................................................................11 6. CARRIER FREQUENCY SEPARATION TEST........................................................................ 15 6.1. Block Diagram of Test Setup..................................................................................................................15 6.2. The Requirement For Section 15.247(a)(1) ............................................................................................15 6.3. EUT Configuration on Measurement .....................................................................................................15 6.4. Operating Condition of EUT ..................................................................................................................15 6.5. Test Procedure ........................................................................................................................................16 6.6. Test Result ..............................................................................................................................................16 7. NUMBER OF HOPPING FREQUENCY TEST ......................................................................... 20 7.1. Block Diagram of Test Setup..................................................................................................................20 7.2. The Requirement For Section 15.247(a)(1)(iii) ......................................................................................20 7.3. EUT Configuration on Measurement .....................................................................................................20 7.4. Operating Condition of EUT ..................................................................................................................20 7.5. Test Procedure ........................................................................................................................................21 7.6. Test Result ..............................................................................................................................................21 8. DWELL TIME TEST ..................................................................................................................... 23 8.1. Block Diagram of Test Setup..................................................................................................................23 8.2. The Requirement For Section 15.247(a)(1)(iii) ......................................................................................23 8.3. EUT Configuration on Measurement .....................................................................................................23 8.4. Operating Condition of EUT ..................................................................................................................23 8.5. Test Procedure ........................................................................................................................................24 8.6. Test Result ........…
Text truncated - open the document above for the full version.
Radiated spurious emission (up to 1G): Radiated spurious emission (Above 1G): Conducted emission:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 675.00 µW |

MULTIMEDIA SPEAKER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Headphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MULTIMEDIA SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter