Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Step 1 1 2 34 Step 2 Step 3 Step 4 SB-250 Sub-Woofer Sub-Woofer Manual of Sound Bar System Sound Bar Speaker(2.1CH) SB-250 Package Contents Quick Connection Guide SB-250 Sound Bar Plug the AC adapter into the wall outlet. The jack is located on the back of the system. Switch Power button to On position to turn on power. Both on Suond Bar and Sub-Woofer have a Power button. Switch on the “Stand-By” button on sound bar. Tune volume, bass, treble with remote control and setting up EQ per your taste. RCA audio cableManual www.foreshot.com 3.5mm audio cableRemote Control Power Adapter (100-240V~50/60Hz) Power Volume DownVolume Up Source FCC Statement Canada Statement Important safety instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio RSS-210. L'exploitation est autorisee aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. CAUTIONCAUTION PRECAUCIONATTENTION Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. RISK OF ELECTRIC SHOCK DO NOT OPEN RIESGO DE CORRIENTAZO NO ABRA RISQUE D'ELECTROCUTION NEPAS OUVRIR WARNING: The battery (battery or batteries or battery pack) shall not be exposed to excessive heat such as sunshine, fire or the like. WARNING: To reduce the ridk of fire or electric shock, do not expose this apparatus to rain or moisture. To reduce the risk of the electric shock, do not remove cover. No user-serviceable parts inside. refer servicing to qualified service personnel. PRECAUCION: Para reducir el riesgo de incendios o descargas electricas, no permita que este aparato quede expuesto a la lluvia o la humedad. Para disminuoir el riesgo de corrientazo. No abra la cubierta. No hay piezas adentro que el usario puedo reparar deje todo mantenimiento a los technicos calificados. EXPLANATION OF GRAPHICAL SYMBOLS: EXPLICACION DE SIMBOLOS GRAFICOS: EXPLICATION DES SYMBÔLES GRAPHIQUES: "DANGEROUS VOLTAGE" "VOLTAJE PELIGROSO" "DANGER HAUTE TENSION" "IT IS NACESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL" "ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES." "REFERREZ-VOUS AU MANUAL D'UTILISATION" ATTENTION: Protégez cet appareil de la pluie et de l'humidité afin d'éviter tout risque d'incendie ou d'électrocution. Pour reduire d'electrocution ne pas enlever le couvercle aucune piece interne n'est repra par l'utilisateur. Pour toute reparation, s'adresser a un technicien qualifie. CONSIGNES DE SÉCURITÉ IMPORTANTES 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus(including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or ground plug: A polarized plug has two blades with one wider than the other. The wide blade is provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plug, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lighting storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spille…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Project No.: 1208C137 Page 3 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 4 of 12 1208C137 1208C137
Neutron Engineering Inc. Project No.: 1208C137 Page 5 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 6 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 7 of 12 1208C137 1208C137 1208C1371208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 8 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 9 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 10 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 11 of 12 1208C137 1208C137 Neutron Engineering Inc. Project No.: 1208C137 Page 12 of 12 1208C137 1208C137
Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 1 of 74 FCC/IC Radio Test Report FCC ID: OT9SB250123601 IC: 10588A-SB250123601 This report concerns (check one) : Original Grant Class II Change Issued Date : Sep. 07, 2012 Project No. : 1208C137 Equipment : Sound Bar Speaker(2.1CH) Model Name : SB-250 Applicant : FORE SHOT Industrial corporation Address : No.7-1,Mincyuan Rd, Da yuan Shiang, Taoyuan County 337,Taiwan(R.O.C) Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Aug. 17, 2012 Date of Test: Aug. 17, 2012 ~ Sep. 06, 2012 Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 2 of 74 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 3 of 74 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 13 4 . EMC EMISSION TEST 14 4.1 CONDUCTED EMISSION MEASUREMENT 14 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 14 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 14 4.1.3 TEST PROCEDURE 15 4.1.4 DEVIATION FROM TEST STANDARD 15 4.1.5 TEST SETUP 15 4.1.6 EUT OPERATING CONDITIONS 15 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 24 4.2.1 RADIATED EMISSION LIMITS 24 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 25 4.2.3 TEST PROCEDURE 26 4.2.4 DEVIATION FROM TEST STANDARD 26 4.2.5 TEST SETUP 27 4.2.6 EUT OPERATING CONDITIONS 28 4.2.7 TEST RESULTS (BELOW 30MHZ) 29 4.2.8 TEST RESULTS (BETWEEN30 – 1000 MHZ) 30 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 34 5 . NUMBER OF HOPPING CHANNEL 48 5.1 APPLIED PROCEDURES / LIMIT 48 5.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 48 5.1.2 TEST PROCEDURE 48 5.1.3 DEVIATION FROM STANDARD 48 5.1.4 TEST SETUP 48 5.1.5 EUT OPERATION CONDITIONS 48 5.1.6 TEST RESULTS 49 Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 4 of 74 Table of Contents Page 6 . AVERAGE TIME OF OCCUPANCY 50 6.1 APPLIED PROCEDURES / LIMIT 50 6.1.1 MEASUREMENT INSTRUMENTS LIST 50 6.1.2 TEST PROCEDURE 50 6.1.3. TEST SETUP LAYOUT 50 6.1.4. TEST DEVIATION 50 6.1.5. EUT OPERATION DURING TEST 50 6.1.6. TEST RESULTS 51 7 . HOPPING CHANNEL SEPARATION MEASUREMENT 53 7.1 APPLIED PROCEDURES / LIMIT 53 7.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 53 7.1.2 TEST PROCEDURE 53 7.1.3 DEVIATION FROM STANDARD 53 7.1.4 TEST SETUP 53 7.1.5 EUT OPERATION CONDITIONS 53 7.1.6 TEST RESULTS 54 8 . BANDWIDTH TEST 56 8.1 APPLIED PROCEDURES / LIMIT 56 8.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 56 8.1.2 TEST PROCEDURE 56 8.1.3 DEVIATION FROM STANDARD 56 8.1.4 TEST SETUP 56 8.1.5 EUT OPERATION CONDITIONS 56 8.1.6 TEST RESULTS 57 9 . PEAK OUTPUT POWER TEST 60 9.1 APPLIED PROCEDURES / LIMIT 60 9.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 60 9.1.2 TEST PROCEDURE 60 9.1.3 DEVIATION FROM STANDARD 60 9.1.4 TEST SETUP 60 9.1.5 EUT OPERATION CONDITIONS 60 9.1.6 TEST RESULTS 61 10 . ANTENNA CONDUCTED SPURIOUS EMISSION 63 10.1 APPLIED PROCEDURES / LIMIT 63 10.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 63 10.1.2 TEST PROCEDURE 63 10.1.3 DEVIATION FROM STANDARD 63 10.1.4 TEST SETUP 63 10.1.5 EUT OPERATION CONDITIONS 63 10.1.6 TEST RESULTS 64 Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 5 of 74 Table of Contents Page 11 . EUT TEST PHOTO 70 Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 6 of 74 1. CERTIFICATION Equipment : Sound Bar Speaker(2.1CH) Brand Name : FORE SHOT Model Name : SB-250 Applicant : FORE SHOT Industrial corporation Factory : FORE TECH Optical(ZHONG SHAN)CO.,LTD. Address : No.8, Zhiye Road Torch Development Zone, Zhong Shan City, Guangdong China Date of Test : Aug. 17, 2012 ~ Sep. 06, 2012 Test Item : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.247) / ANSI C63.4 : 2009 FCC Public Notice DA 00-705, March 30, 2000. Canada RSS-210:2010 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1208C137) were obtained utilizing the test p…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 70 of 74 11. EUT TEST PHOTO Conducted Measurement Photos AUX IN/TV IN with Wireless – TX Smple Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 71 of 74 Conducted Measurement Photos AUX IN/TV IN with Wireless – RX Smple Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 72 of 74 Radiated Measurement Photos 9K-30MHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 73 of 74 Radiated Measurement Photos 30MHz-1GHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1208C137 Page 74 of 74 Radiated Measurement Photos Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 5.00 mW |
Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Stereo BT Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Mini Touch Boom Box
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Portable Stereo Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter