FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Million Concept Electronic (Shenzhen) Co., Ltd/
  3. OVJW183

OVJW183Bluetooth 4.0 Low Energy Heart Rate Monitor

Million Concept Electronic (Shenzhen) Co., Ltd
Bluetooth 4.0 Low Energy Heart Rate Monitor - FCC ID OVJW183 - Million Concept Electronic (Shenzhen) Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 21, 2013
Application Purpose
Original Equipment
Date of Application
Jan 21, 2013
Equipment Note
Bluetooth 4.0 Low Energy Heart Rate Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Million Concept Electronic (Shenzhen) Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

W183 Bluetooth 4.0 Low Energy Heart Rate Monitor User Manual Caring for your sensor and strap the sensor with soft towel or use mild soap and water Bluetooth QD ID : B020362 Important Product Information solution when needed. Do not use alcohol or other cleaning chemicals. Sensor – Remove the sensor from the strap after use. Dry Strap – After use, put the strap under the water and hang to dry. Never put the strap or the sensor in a washing machine or dryer. Dry and store the sensor and strap separately to maintain the battery life. Replace Battery Receiving device can show display the battery level of your heart rate sensor. 2. Remove the old battery. 3. Insert the new battery (CR2032) inside the battery compartment with the positive (+) side up. 4. Make sure the sealing rubber ring is in the groove of the compartment to ensure the water resistance. 5. Put the cover back to senor. 6. Use a coin to turn the cover clockwise to CLOSE. 1. Using a coin and turning the battery cover counterclockwise to OPEN. Battery replacement: Heart Rate Sensor Parts 1. Transmitting sensor send heart rate signal to Bluetooth 4.0 smart ready device. The Heart Rate Sensor have two parts : How to wear the heart rate sensor 1. Moisten the electrode area on strap. Getting Start 2. Adjust strap length to t chest comfortably tightly. 3. Tie strap around your chest below chest muscles and attach the hook to other end of strap. 4.Snap transmitting attach sensor on the textile strap button. Please pay attention to the orientation. 2. Textile strap with electrode area to detect heart rate signal. For rst time of use the chest belt sensor. Turn on the Bluetooth connection on your Smart Ready device(Such as smart phone which equipped with Bluetooth 4.0) and pair up the sensor. To ensure sucient transmission range(within 10m) from sensor to receiving device, keep the device in front of you or place in the pocket. Then you can view your heart rate data on the receiving device. IC warning statements: “This device complies with Industry Canada licence -exempt RSS standard(s).Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this devicemust accept any interference,including interference that may cause undesired operation of the device." - French Warning Statement: - English Warning Statement: “Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement." FCC warning statements: Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 1 Rev 2.0 Million Concept Electronic (Shenzhen) Co., Ltd Add: No.98,Xiashanmen Road, Songgang Town, Bao'an District, Shenzhen, China Tel: 86 755 33663118 Fax: 86 755 33925026 2013-01-04 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: OVJW183 We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics Diagram - Block Diagram - Operation description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s name / title : Amy Yan / Manager Contact information / address : No.98,Xiashanmen Road, Songgang Town, Bao'an District, Shenzhen, China Tel: 86 755 33663118 Fax: 86 755 33925026 E-Mail: [email protected]

Cover Letter(s)

Million Concept Electronic (Shenzhen) Co., Ltd Add: No.98,Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Tel: 86 755 33663118 Fax: 86 755 33925026 2013-01-04 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD We, Million Concept Electronic (Shenzhen) Co., Ltd, declare that this product (FCC ID: OVJW183) Only supports Bluetooth 4.0 (DTS only) without other previous BT version (DSS) function. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Client’s name / title: Amy Yan / Manager Contact information / address: No.98,Xiashanmen Road, Songgang Town, Bao'an District, Shenzhen, China Tel: 86 755 33663118 Fax: 86 755 33925026 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 4 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 4 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 4 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 4 Fig.7

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size: L2.0cm*W1.5cm Label Location Model No.: W183 FCC ID: OVJW183 Made in China

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 4 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 4 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 4 Fig.6 Fig.6 Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 4 Fig.7

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.: LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 36 FCC TEST REPORT For Million Concept Electronic (Shenzhen) Co., Ltd Bluetooth 4.0 Low Energy Heart Rate Monitor Model No.: W183 Prepared for : Million Concept Electronic (Shenzhen) Co., Ltd Address : No.98, Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Date of receipt of test sample : December 19, 2012 Number of tested samples : 1 Serial number : Prototype Date of Test : December 19, 2012 - January 04, 2013 Date of Report : January 04, 2013 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.: LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 36 FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) / RSS-210 Issue 8/RSS-Gen Issue 3 Report Reference No. .............. : LCS121219117QF Date of Issue ................................ : January 04, 2013 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................ : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure........ : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name....................... : Million Concept Electronic (Shenzhen) Co., Ltd Address ........................................ : No.98, Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Test Specification Standard ....................................... : FCC CFR 47 PART 15 C(15.247) / RSS-210 Issue 8/ RSS-Gen Issue 3 Test Report Form No................. : LCSEMC-1.0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Bluetooth 4.0 Low Energy Heart Rate Monitor Trade Mark .................................. : Model/ Type reference................. : W183 Ratings ......................................... : DC 3.0V by button cell Result ......................................... : Positive Compiled by: Supervised by: Approved by: Yoyo Wang/ File administrators Vito Cao/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.: LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 36 FCC -- TEST REPORT Test Result: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS121219117QF January 04, 2013 Date of issue Type / Model........................... : W183 EUT......................................... : Bluetooth 4.0 Low Energy Heart Rate Monitor Applicant............................... : Million Concept Electronic (Shenzhen) Co., Ltd Address.................................. : No.98, Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Million Concept Electronic (Shenzhen) Co., Ltd Address................................... : No.98, Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Factory................................... : Million Concept Electronic (Shenzhen) Co., Ltd Address................................... : No.98, Xiashanmen Road, Songgang Town, Bao’an District, Shenzhen, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.: LCS121219117QF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 36 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................................. 5 1.1. DESCRIPTION OF DEVICE (EUT) ....................................................................................................................................... 5 1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS......................................................................................................... 5 1.3. EXTERNAL I/O PORT......................................................................................................................................................... 5 1.4. DESCRIPTION OF TEST FACILITY....................................................................................................................................... 6 1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY........................................................................................................ 6 1.6. …

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: OVJW183 Report No.:LCS121219117QF _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 1. TEST SETUP PHOTOGRAPHS Radiated Emission Measurement Fig.1 Fig.2

Contact Information

Applicant

Yiqin Liu
[email protected]86-755-33663118Fax: 86-755-33925026

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]86-0755-82591330Fax: 86-0755-82591332

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz770.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Million Concept Electronic (Shenzhen) Co., Ltd

Physical activity belt - FCC ID OVJ-MZSWITCH2 - Million Concept Electronic (Shenzhen) Co., Ltd
OVJ-MZSWITCH2

Physical activity belt

Feb 11, 2026

Equipment Class

DTS - Digital Transmission System
Physical activity belt - FCC ID OVJMZSW - Million Concept Electronic (Shenzhen) Co., Ltd
OVJMZSW

Physical activity belt

Apr 12, 2021

Equipment Class

DTS - Digital Transmission System
Physical Activity Belt - FCC ID OVJMZ-3 - Million Concept Electronic (Shenzhen) Co., Ltd
OVJMZ-3

Physical Activity Belt

Aug 20, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Wristband - FCC ID OVJW307 - Million Concept Electronic (Shenzhen) Co., Ltd
OVJW307

Bluetooth Wristband

Jul 30, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Activity & Sleep Monitor Wristband - FCC ID OVJ-W240 - Million Concept Electronic (Shenzhen) Co., Ltd
OVJ-W240

Bluetooth Activity & Sleep Monitor Wristband

Aug 28, 2014

Equipment Class

DTS - Digital Transmission System