OXJTF40Forehead Thermometer

NantCare LLC
Forehead Thermometer - FCC ID OXJTF40 - NantCare LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 28, 2012
Application Purpose
Original Equipment
Date of Application
Aug 28, 2012
Equipment Note
Forehead Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
NantCare LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Version # 2 05-17-2012, VJ Smart Forehead Thermometer - User Guide 1.1. Introduction Thank you for choosing the NantLife Smart Forehead Thermometer. This innovative medical device relies on advanced infrared (IR) technology to measure temperature instantly. Your new digital thermometer uses the infrared heat generated by patient’s skin. The thermometer then converts it into a temperature value displayed on the OLED screen. Note: The thermometer does not emit any infrared signal. With its unique wireless integrated technology, the NantLife Smart Forehead Thermometer enables you to perform first-class, comfortable and extremely gentle body temperature measurements. You have chosen the most up-to-date form of healthcare management. Measured values are transmitted automatically to a secured database via a Bluetooth-enabled mobile phone and/or the HBox hub. Choose between 2 basic configurations: a) Smart Medical Home with the HBox b) Mobile Health with your Bluetooth-enabled smartphone The NantLife Smart Forehead Thermometer comes with the following components: • Monitor with OLED display • ON/OFF button • Instruction Manual printed in English, French and Spanish • Warranty card Thank you for your trust; we are available at any time for service and product questions. More Information at: www.NantLife.com SAVE THESE INSTRUCTIONS 1.2. Intended Use • NantLife Smart Forehead Thermometer is intended for home monitoring of body temperature. • The NantLife Smart Forehead Thermometer is not intended to be a diagnostic device. • Never change your medication on the basis of results you have obtained. The evaluation of the measurements and the treatment based on them may only be carried out by the treating physician. • This device is intended for use in measuring body temperature b 1.3. Safety Information To assure the correct use of the thermometer, basic safety measures should always be followed including the warnings and cautions lifted in this instruction manual. 1.3.1 Operating the device - 1.3.1.1 Warnings! Read all of the information in the instruction manual and any other instruction in the box before operating the thermometer. If you experience discomfort during a measurement- Remove the probe and stop using the device. Please contact NantLife Customer Service. In addition, please note: • Proper technique is crucial to getting accurate temperature readings. Please read this manual carefully before using the device. • Basic safety precautions should always be observed, especially when the thermometer is used on or near children and disabled persons. • Do not under any circumstances use the device in the bath or the shower. If, however, liquid get into the device, you must remove the batteries immediately and refrain from further use. Contact our service department (see front cover). • The device may not be used near a nuclear magnetic tomographic resonance. • Using components that are not part of the scope of delivery can produce faulty measurements (Exception: battery replacement). • DO NOT subject the monitor to strong shocks such as dropping the unit on the floor. • DO NOT damage the batteries. If battery fluid gets in your eyes, immediately rinse with plenty of clean water and contact a physician immediately. • Keep away from source of fire and/or heat. • Store the device in a clean, safe location. • DO NOT disassemble the Forehead Thermometer. • DO NOT use the Forehead Thermometer in a MRI or CT environment. • DO NOT use the Forehead Thermometer in the presence of flammable anesthetics. • Explosion hazard: DO NOT use the Forehead Thermometer in an explosive atmosphere. • Chemicals from OLED panel are toxic if ingested. Use caution if the Forehead Thermometer display screen is broken. • The Forehead Thermometer is intended only as an adjunct in patient assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms. • Check the Forehead Thermometer application site frequently to determine skin sensitivity of the patient. • Use only 1.5V alkaline batteries with this device. Other type of battery may damage the unit. • Follow local ordinances and recycling instructions regarding disposal or recycling of the device components, including batteries. • Only the authorized service personnel can repair this device. 1.3.1.2 Cautions • Autoclaving, ethylene oxide sterilizing, or immersing the Forehead Thermometer in liquid may cause inaccurate measurements. • Excessive user movement may cause inaccurate readings. • All NantLife devices are designed to be compliant with rules and regulations in locations they are sold and are labeled as required. • Any changes or modifications to NantLife equipment, not expressly approved by NantLife void the user’s authority to operate the device. 1.4 Before taking a Measurement General information about normal body temperature and fever. Body temperature can vary from one individual to the next. It also varies by location on the body and time of the day. See below the statistical normal ranges for different sites: Body Site Normal Temperature Range Oral 35.5°C – 37.5°C 95.9°F – 99.5°F Axillary (underarm) 34.7°C – 37.3°C 94.5°F – 99.1°F Rectal 36.6°C – 38.0°C 97.9°F – 100.4°F Ear 35.8°C – 38.0°C 96.4°F – 100.4°F Chamberlain, J.M. Terndrup, T.E., New Light on Thermometer Readings, Contempory Pediatrics, March 1994 Temperatures measured from different sites, even at the same time, should not be compared. Fever indicates that the body temperature is higher than normal. This symptom may be cause by infection, overdressing or immunization. Some people may not experience fever even if they are ill. These include, but are not limited to, infants under 3 months old, persons with compromised immune systems, person with chronic diseases, person taking antibiotics, steroids or antipyretic such as aspirin, ibuprofen and/or acetaminophen. Please consult your physician when you feel ill even if you do not have fever. Your healthcare provider…

Text truncated - open the document above for the full version.

Cover Letter(s)

Aug Fed Aut FCC Re: Pur s requ 1: B 2: C 3: O 4: P Th e rele app Th e all a app Sin c Nan Con g. 9, 2012 deral Comm thorization C ID: OXJT : Confiden suant to Se uests confid Block Diagra Circuit Diagra Operational D Parts List e above mat ased to the licant and p e Applicant u accompanyi lication. cerely, ntCare LLC ntact Peop munication and Evalu TF40 ntiality Re ctions 0.457 ential treatm m am Description terials conta e public. The rovide unjus understands ng docume n C ple: Rechar n Commiss uation Divis quest 7 and 0.459 ment of infor ain trade se e public dis stified benef that pursua ntation will rd Binier sion sion 9 of the Com rmation appl ecrets and p sclosure of t fits to its com nt to Rules 0 not be mad mmission’s R ied this app proprietary these matte mpetitors. 0.457, disclo e before th Rules, the a lication as o information ers might be osure of this e date of th applicant he outlined belo not custom e harmful to s Application he Grant for ereby ow: marily o the n and r this

External Photos

PHOTOGRAPHS OF THE EUT Top View of EUT Button View of EUT Front of EUT Back View of EUT Left View of EUT Right View of EUT

ID Label/Location Info

Forehead Thermometer Model Name:TF4.0 Brand Name:NantLife FCC ID: OXJTF40

Internal Photos

Open View of EUT-1 Internal View of EUT-1 Internal View of EUT-2 Internal View of EUT-3 Bluetooth Antenna

Test Report

FCC PART 15&RSS­210 Test Report Report No.: AGC026120701F2 FCC ID : OXJTF40 IC : 10549A‐TF40 PRODUCT DESIGNATION : Forehead Thermometer BRAND NAME : NantLife TEST MODEL : TF4.0 CLIENT : NantCare LLC DATE OF ISSUE : Aug.08, 2012 STANDARD(S) : FCC Part 15 Rules& RSS‐210 REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC026120701F2 Page 1 of 37 VERIFICATION OF COMPLIANCE Applicant NantCare LLC 2929 N. 44th Street, Suite 110 Phoenix, AZ 85018 Manufacturer Shenzhen Jian Lang Technology Ltd. C202, 2F, Blook 1, Nanyou Tian'an Industry Town, SZ. R.P.C Product Designation Forehead Thermometer Brand Name NantLife Model Name TF4.0 FCC ID OXJTF40 IC 10549A-TF40 Report Number AGC026120701F2 Date of Test Jul.30, 2012 to Aug.03, 2012 WE HEREBY CERTIFY THAT: The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) .The sample tested as described in this report is in compliance with the FCC Rules Part 15 and RSS-210 requirements The test results of this report relate only to the tested sample identified in this report. Tested By Bart Xie Aug.08, 2012 Reviewed By Forrest Lei Aug.08, 2012 Approved By Solger Zhang Aug.08, 2012 Report No.: AGC026120701F2 Page 2 of 37 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................................. 4 1.1 PRODUCT DESCRIPTION ....................................................................................................................... 4 1.2 TABLE OF CARRIER FREQUENCYS ...................................................................................................... 4 1.3 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................... 5 1.4 TEST METHODOLOGY ............................................................................................................................ 5 1.5 TEST FACILITY ......................................................................................................................................... 5 1.6 SPECIAL ACCESSORIES ......................................................................................................................... 5 1.7 EQUIPMENT MODIFICATIONS ................................................................................................................ 5 2. SYSTEM TEST CONFIGURATION ................................................................................................................................... 6 2.1 CONFIGURATION OF TESTED SYSTEM................................................................................................ 6 2.2 EQUIPMENT USED IN EUT SYSTEM ...................................................................................................... 6 3. SUMMARY OF TEST RESULTS ....................................................................................................................................... 7 4. DESCRIPTION OF TEST MODES .................................................................................................................................... 7 5. PEAK OUTPUT POWER ..................................................................................................................................................... 8 5.1 LIMITS ........................................................................................................................................................ 8 5.2 MEASUREMENT PROCEDURE ................................................................................................................ 8 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ....................................................................... 8 5.4 MEASUREMENT EQUIPMENT USED ....................................................................................................... 9 5.5 MEASUREMENT RESULT ......................................................................................................................... 9 6. DB BANDWIDTH ................................................................................................................................................................. 10 6.1 LIMITS ...................................................................................................................................................... 10 6.2 MEASUREMENT PROCEDURE ............................................................................................................. 10 6.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ..................................................................... 10 6.3 MEASUREMENT EQUIPMENT USED ................................................................................................... 10 6.5 MEASUREMENT RESULTS .................................................................................................................... 10 7. 99% BANDWIDTH ............................................................................................................................................................... 13 7.1 LIMITS ...................................................................................................................................................... 13 7.2 MEASUREMENT PROCEDURE .............................................................................................................. 13 7.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ..................................................................... 13 7.4 MEASUREMENT EQUIPMENT USED .........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

PHOTOGRAPHS OF THE TEST SETUP RADIATED SPURIOUS EMISSION

Contact Information

Applicant

Richard Binier
[email protected]1-855-626-8227Fax: 1-602-293-3717

Test Firm

Attestation of Global Compliance Shenzhen Co. Ltd.Forrest Lei
[email protected]86-755-29081966Fax: 86-755-26008484

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.50 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from NantCare LLC

HPod - FCC ID OXJHPOD40 - NantCare LLC
OXJHPOD40

HPod

Oct 10, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Pulse Oximeter - FCC ID OXJOF40 - NantCare LLC
OXJOF40

Smart Pulse Oximeter

Oct 10, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Ear Thermometer - FCC ID OXJTE40 - NantCare LLC
OXJTE40

Smart Ear Thermometer

Oct 10, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Body Scale - FCC ID OXJBS40 - NantCare LLC
OXJBS40

Smart Body Scale

Oct 10, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Arm Blood Pressure Monitor - FCC ID OXJBP40 - NantCare LLC
OXJBP40

Smart Arm Blood Pressure Monitor

Aug 29, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter