FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Comuniq Inc./
  3. OXLPMC-E1T1

OXLPMC-E1T1PMC Telecommunication Card

Comuniq Inc.
PMC Telecommunication Card - FCC ID OXLPMC-E1T1 - Comuniq Inc.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Mar 29, 2000
Application Purpose
Original Equipment
Date of Application
Mar 15, 2000
Equipment Note
PMC Telecommunication Card
Company
Comuniq Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SMAS E1/T1 BOARD User Guide Comuniq ASA Version 2.0 – March 2000 Comuniq ASA SMAS User Guide 2.0 Page 2 of 9 Statement of compliance This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE The information in this publication is subject to change without notice. This document contains proprietary information disclosed under a non-disclosure agreement. Disclosure to any third party without written permission from Comuniq ASA is in violation of the non-disclosure agreement. COMUNIQ ASA SHALL NOT BE HELD LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIA L. This publication contains information protected by copyright. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without written permission from Comuniq ASA. Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. © 2000 Comuniq ASA, All rights reserved. Comuniq ASA SMAS User Guide 2.0 Page 3 of 9 Corporate HQCustomer Support Comuniq ASAComuniq Inc. Solakrossen 112046 Samco Rd. N-4050 SolaRapid City, SD 57701 NorwayUSA Phone: +47 51 71 55 55Phone: 1-605-388-3251 Fax: +47 51 71 55 56Fax: 1-605-348-4030 WEB: http://www.comuniq.comE-Mail: [email protected] Comuniq ASA SMAS User Guide 2.0 Page 4 of 9 Table of Contents CHAPTER 1..................................................................................................... INTRODUCTION 5 CHAPTER 2...................................................................................................... INSTALLATION 6 2.1H ARDW ARE ..................................................................................................................... 6 2.2S OFTWARE ...................................................................................................................... 8 2.3U PDATING THE FIRMWARE ON THE SMAS BOARD .............................................................. 9 Comuniq ASA SMAS User Guide 2.0 Page 5 of 9 Chapter 1 Introduction Comuniq’s Streaming Media Application Server (SMAS) E1/T1 resource board provides a powerful and flexible IP telecom platform for a variety of telecom functions. These include: interactive voice response, voice over IP, and unified messaging system applications. Powerful on-board CPU/DSP resources handle up to 60 channels of voice traffic, and allow extensive IP signal processing using a single PCI slot. The boards are 100% compliant with PMC specifications and fit both PCI and cPCI systems. The SMAS board draws a maximum power-load of 7.1319 volts +/- 5% and an average power load of 6.0672 volts. This hardware is supported by an integrated software suite that offers easy access to all of the SMAS board’s functio ns using Wi ndo ws NT, Solaris, or Li nu x. The open Application Progra mmer ’s Interface (API) and extensible message interface facilitates efficient development and integration of third party software. Using the SMAS API, a programmer working with visual studio can develop a simple voice mail system with remarkably little code. Developers using the Microsoft COM environment can also access the board’s functionality using the SMAS COM object or ActiveX control. This document explains the installation and use of the E1/T1 interface board and software. The target system for the SMAS board must comply with the following requirements: ProcessorPentium 200MHz, minimum HD space100 MB of available hard-disk space, minimum Memo ry64 MB, mi ni mu m 128 MB, recommended when running more than 30 channels of IVR DisplayVGA, 800 x 600, 256-color video adapter Operating SystemWindows NT 4.0 (service pack 3 or later) Development EnvironmentVisual Studio with service pack 3 or later MotherboardPCI ver 2.1 or later, 32 bit @ 33 MHz Comuniq ASA SMAS User Guide 2.0 Page 6 of 9 Chapter 2 Installation 2.1 Hardware 2.1.1 Safety Notes Before installation, please observe the following: WARNING! Turn the computer off, disconnect the power source, and allow the internal components to cool before beginning installation. This will reduce the risk of personal injury from hot surfaces and electrical hazards . The SMAS board is a static sensitive device and requires compliance with static precaution measures. CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly grounded before beginning this procedure. Proper packaging and grounding techniques are necessary precautions to prevent damage. To prevent electrostatic damage observe the following precautions: • Transport products in static-safe containers such as conductive tubes, bags, or boxes. • Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations. • Cover work areas with an approved static-dissipating material. Wear a grounding wrist strap that has been connected to the work surface, and make sure that all tools and equipment are properly grounded. • Keep work area free of non-conductive materials including the plastic assembly aids and foam used in packing. • Always wear a properly grounded wrist strap when touching a static-sensitive component or assembly. • Avoid touching pins, leads, or circuitry. 2.1.2 Installation Before beginning installation, turn off all power to the computer designated for the installation of the SMAS board. Failure to do so may damage the computer and/or SMAS board. Insert the SMAS board into an available PCI or Compact PCI slot. Ensure that the board is securely held in place by either screws or clips. Comuniq ASA SMAS User Guide 2.0 Page 7 of 9 Figure 2-1 This photograph shows the SMAS board installed i…

Text truncated - open the document above for the full version.

Block Diagram

SMAS E1/T1 BOARD Block Diagram Comuniq ASA Version 2.0 – March 2000 Comuniq ASA SMAS User Guide 2.0 Page 2 of 5 NOTICE The information in this publication is subject to change without notice. This document contains proprietary information disclosed under a non-disclosure agreement. Disclosure to any third party without written permission from Comuniq ASA is in violation of the non-disclosure agreement. COMUNIQ ASA SHALL NOT BE HELD LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIA L. This publication contains information protected by copyright. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without written permission from Comuniq ASA. Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. © 2000 Comuniq ASA, All rights reserved. Corporate HQCustomer Support Comuniq ASAComuniq Inc. Solakrossen 112046 Samco Rd. N-4050 SolaRapid City, SD 57701 NorwayUSA Phone: +47 51 71 55 55Phone: 1-605-388-3251 Fax: +47 51 71 55 56Fax: 1-605-348-4030 WEB: http://www.comuniq.comE-Mail: [email protected] Comuniq ASA SMAS User Guide 2.0 Page 3 of 5 This document will give the reader an understanding of the functionality of the SMAS. The first section describes the system, followed by a functional description of the SMAS board. 1.1 The SMAS System SMAS is a firmware platform that enables system integrators to implement services such as Automatic Call Distribution (ACD), Interactive Voice Response (IVR), Private Branch Exchange (PBX), and IP- telephony for E1/T1 connections. The SMAS system is a scalable telephony system, which may consist of a maximum of 36 SMAS cards per Compact PCI PC. The main host of the system is a Windows NT server. The block diagram in Figure 1 illustrates the scalability where a large number SMAS cards can be attached on the PCI bus under supervision of Windows NT or a user defined host. Figure 1 – A block diagram of the SMAS telephony system. The system utilizes the PCI bus to transfer telecommunication data in a maximum configuration of 4320 voice channels for E1 and 3456 voice channels for T1. 1.2 Hardware The hardware is divided into four layers. Of these four layers, all but the host computer are physically located on the SMAS card. - Host computer, Windows NT (NT) - Embedded I 2 O Processor, Intel 80960RD (i960) - Digital Signal Processor, Texas Instrument’s TMS320C6201 (C6) - Line Interface Adapter, Siemens Falc’54 (FALC’54) The architecture enables a total of 120 full duplex voice channels per card for an E1 interface and a total of 92 (or 96) full duplex voice channels per card for a T1 interface. The E1 has, in addition, four D-channels and four synchronization channels, and T1 may have four D-channels when it is configured for use with 92 voice channels. For E1 the line interface runs at 2.048 Mbps, and for the T1 line interface runs at 1.544 Mbps. The data format on the E1/T1 side is G.711, which is standard A-Law (Europe) or μ-Law (USA and Japan). Figure 2 show the SMAS card architecture, which consists of three main components: Falc’54, C6 and i960. Windows NT I960Rx TI C62xTI C62x FALCFALCFALCFALC E1/T1 E1/T1 E1/T1 E1/T1 I960Rx TI C62xTI C62x FALCFALCFALCFALC E1/T1 E1/T1 E1/T1 E1/T1 I960Rx TI C62xTI C62x FALCFALCFALCFALC E1/T1 E1/T1 E1/T1 E1/T1 SMAS #1SMAS #2SMAS #N E1/T1E1/T1E1/T1E1/T1 SMAS #N-1 PCI/I20 Comuniq ASA SMAS User Guide 2.0 Page 4 of 5 Figure 2 also shows the memory configuration and the data flow throughout the system. The PCI interface is 32 bits and runs at 33 MHz, and it interfaces with the i960, which also runs at 33 MHz. The C6 has a 50 MHz external clock allowing 200 MHz internal operation. The Flash contains the IxWorks operating system for the i960 and the firmware code for the Altera, not illustrated in Figure 2. Downloading the program code directly from an NT application configures the system. The i960 has 16 Mbytes external DRAM memory to store data and programs. The i960 runs at 33 MHz on the peripheral interface but has a core clock frequency of 66 MHz. The C6’s each have 16 Mbytes of DRAM for storage of algorithms and data. When fully configured, the SMAS board will handle four full duplex E1/T1 trunks, with each Falc’54 handling one trunk. Figure 2 – A block diagram of the SMAS hardware. The FALC54 requires a 16.384 MHz crystal between XTAL1 and XTAL2 for E1/T1 operation; in addition a 12.352 MHz crystal is required between XTAL3 and XTAL4 for proper T1 operation. XTAL1 and XTAL2 are the in-/outputs for the DCO1, these internal PLL circuitry generates the jitter free system clocks (16 MHz, 8 MHz, 4 / 2 MHz and 8 KHz). XTAL3/4 are the in-/outputs for the DCO2, the main task of the DCO2 in T1 is to generate the dejittered transmit clocks. The crystals should be connected as illustrated in figure 3. Figure 3 -- Jitter free transmit clock requires crystal interconnection. The jitter attenuator requires unique performance specifications for the crystals. The following typical crystal parameters will meet these specifications: - Motional capacitance C1 = 25fF min. - Shunt capacitance C0 = 7pF max. - Load capacitance CL = 15pF typ. FALC'54 FALC'54 TI C62x I960RD E1/T1 E1/T1 Local Bus E1/T1 E1/T1 FALC'54 FALC'54 TI C62x 32 PCI DRAM 16MByte FLASH 2MByte 1616 DRAM 16MByte DRAM 16MByte 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM 2.048Mbps TDM Comuniq ASA SMAS User Guide 2.0 Page 5 of 5 The motional capacitance C1 is responsible for the overall pulling range of the crystal. The load capacitance CL defines the accuracy of the free running frequency. The FALC requires 10pF load capacitance to GND at XTAL1 (XTAL3) and XTAL2 (XTAL4). With additional internal capacitance (about 20pF to GND in free running mode) the cr…

Text truncated - open the document above for the full version.

ID Label/Location Info

I D : O X L P M C - E 1 T 1 Placem ent of m arking s on PM C -E1/T1 FC C ID: OXLPM C-E1T1

Operational Description

Operational Description Comuniq ASA Version 2.0 – March 2000 Comuniq ASA SMAS User Guide 2.0 Page 2 of 3 NOTICE The information in this publication is subject to change without notice. This document contains proprietary information disclosed under a non-disclosure agreement. Disclosure to any third party without written permission from Comuniq ASA is in violation of the non-disclosure agreement. COMUNIQ ASA SHALL NOT BE HELD LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIA L. This publication contains information protected by copyright. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without written permission from Comuniq ASA. Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. © 2000 Comuniq ASA, All rights reserved. Corporate HQCustomer Support Comuniq ASAComuniq Inc. Solakrossen 112046 Samco Rd. N-4050 SolaRapid City, SD 57701 NorwayUSA Phone: +47 51 71 55 55Phone: 1-605-388-3251 Fax: +47 51 71 55 56Fax: 1-605-348-4030 WEB: http://www.comuniq.comE-Mail: [email protected] Comuniq ASA SMAS User Guide 2.0 Page 3 of 3 This document is intended to give the reader an overview of how the Streaming Media Application Board (SMAS) works. Additional information is available in the Block Diagram and User Manual attachments to form 731. The SMAS is designed to interface E1/T1 telephone connections to a standard personal computer. A PCI interface and an I2O protocol handle the transport of multimedia traffic (voice, video, and data) from the board to the PC. A 32-bit local bus interfaces the board and the E1/T1 connection. The card enables system integrators to implement services such as Automatic Call Distribution (ACD), Interactive Voice Response (IVR) and Private Branch Exchange (PBX) for E1/T1 connections. A distributed organization of the computation power and the Digital Switching Network (DSN) limits the traffic over the PCI bus. On one side, the DSN communicates with the I960 and I2O to get a peer- to-peer communication between two SMAS cards or between a telephone channel and a hard drive. On the other side, a channel connection, compression, services, and echo canceling are handled by the C6. Having a DSN level at C6, which means that data is available in uncompressed and unpacked form, enables conferencing summarization at that level. DSN is entirely controlled by the call control, which indicates which channels are connected, which signaling technique are used, and which compression and packaging is used. The line adaptation (LAD) consists of three main functions; I/O, packing and compression. Most of this functionality is handled by the digital signal processing units. The I/O consists of interfaces to external formats such as IP, HD, E1/T1 and ISDN BRI. The supported packaging will include ATM frames and ISDN BA. The compression unit converts compressed data to a format that is feasible for the DSN. The compression standards supported will be G721, G722, G723.1, G711, G729A and G726.

Schematics

1 2 3 4 5 6 78 A BC D 8 7 6 5 4 3 2 1 D CBA 9 C om un i q A S ASolakrossen 11,P.O. Box 27,N-4050 SolaNorway 9 433 9 1 6- M ar - 2 00 0 1 8: 5 2 : 59 C:\Roy\smas\Pmc-e1.prj TitleSize : N umber : Date: File : Revision: Sheet of Time: Error : Comuniq logo.bmp file not f o A3 ET1S1, ET1S2, ET1D1, ET1D2 or ET1Q2 DATA-BUSADDR-BUS CTRL-BU S TDM-BUS JTAG-BUS I 960/Alte r a/FL ASHPmc-e1qa.sch DATA-BUSADDR-BUS CTRL-BU S TDM-BUS JTAG-BUSCTRL-BU SJTAG-BUS TDM-BUS I960 PCI InterfacePmc-e1qb.sch CTRL-BU SJTAG-BUS TDM-BUS DATA-BUSADDR-BUSCTRL-BU STDM-BUSJTAG-BUS DSP0Pmc-e1qc.sch DATA-BUSADDR-BUSCTRL-BU STDM-BUSJTAG-BUSDATA-BUSADDR-BUSCTRL-BU STDM-BUS DSP1Pmc-e1qd.sch DATA-BUSADDR-BUSCTRL-BU STDM-BUSDATA-BUSADDR-BUSCTRL-BU STDM-BUS ISDN-BUS JTAG-BUS FAL C0/1Pmc-e1qe.sch DATA-BUSADDR-BUSCTRL-BU STDM-BUS ISDN-BUS JTAG-BUSDATA-BUSADDR-BUSCTRL-BU STDM-BUS ISDN-BUS JTAG-BUS FAL C2/3Pmc-e1qf.sch DATA-BUSADDR-BUSCTRL-BU STDM-BUS ISDN-BUS JTAG-BUS ISDN-BUS T1/E1 connector + 2.5v supplyPmc-e1qg.sch ISDN-BUS PCI Bus Power supply to various chipspmc-pwr.sch 1 2 3 4 5 6 78 A BC D 8 7 6 5 4 3 2 1 D CBA 1 C om un i q A S ASolakrossen 11,P.O. Box 27,N-4050 SolaNorway 9 433 9 1 6- M ar - 2 00 0 1 8: 5 5 : 59 C:\Roy\smas\Pmc-e1qa.sch TitleSize : N umber : Date: File : Revision: Sheet of Time: Error : Comuniq logo.bmp file not f o A3 ET1S1, ET1S2, ET1D1, ET1D2 or ET1Q2 BE0BE1BE2BE3 DATA-BUSADDR-BUSCTRL-BU STDM-BUS DATA-BUSADDR-BUS CTRL-BU STDM-BUS REDGREEN LED1 REDGREEN LED2 REDGREEN LED4 REDGREEN LED3 DATA-BUSADDR-BUSCTRL-BU S CE0 L3 CE1 L1 ADS B21 ALE C20 BLA ST C23 DEN A23 BE0 A22 BE1 B22 BE2 C21 BE3 A21 DACK AD3 D /C/RST_MO DE AF4 W/R C22 DT/R B23 WIDTH/HLTD0 AF5 WIDTH/HLTD1/RETRY AE5 HOLD V1 HOLDA V3 RDY RCV B19 MWE0 J3 MWE1 J1 MWE2 J2 MWE3 K3 DREQ AD2 WA IT N3 PI CCLK U3 PI CD 0 T1 PI CD 1 T2 SCL U1 SDA U2 FAI L AD5 LRST AD6 TCK B24 TDI D26 TDO D25 TRST C25 STE ST AE3 AD0 A18 AD1 B18 AD2 C17 AD3 A17 AD4 B17 AD5 C16 AD6 A16 AD7 B16 AD8 C15 AD9 A15 AD10 B15 AD11 C14 AD12 A14 AD13 B14 AD14 C13 AD15 A13 AD16 B13 AD17 C12 AD18 A12 AD19 B12 AD20 C11 AD21 A11 AD22 B11 AD23 C10 AD24 A10 AD25 B10 AD26 C9 AD27 A9 AD28 B9 AD29 C8 AD30 A8 AD31 B8 DP0 C2 DP1 D3 DP2 D1 DP3 D2 MA0 C7 MA1 A7 MA2 B7 MA3 C6 MA4 B6 MA5 C5 MA6 A5 MA7 B5 MA8 C4 MA9 B4 MA10 C3 MA11 B3 RAS0 E3 RAS1 E1 RAS2 E2 RAS3 F3 CAS0 F1 CAS1 F2 CAS2 G3 CAS3 G1 CAS4 G2 CAS5 H3 CAS6 H1 CAS7 H2 LEAF0 L2 LEAF1 M3 DWE0 K1 DWE0 K2 DALE0 M1 DALE1 M2 TMS C24 LOCK/ONCE AD4 LRD YRCV C19 ICEADS AC1 ICEBRK AA1 ICEBUS0 V2 ICEBUS1 W3 ICEBUS2 W1 ICEBUS3 W2 ICEBUS4 Y3 ICEBUS5 Y1 ICEBUS6 Y2 ICEBUS7 AA3 ICECLK AB2 ICELOCK AB3 ICEMSG AA2 ICESEL AC2 ICEVLD AB1 MSGFRM AC3 NMI T3 U100BINTEL I960RD D0D1D2D3D4D5D6D7D8D9D10D11D12D13D14D15D16D17D18D19D20D21D22D23D24D25D26D27D28D29D30D31 D0D1D2D3D4D5D6D7D8D9D10D11D12D13D14D15D16D17D18D19D20D21D22D23D24D25D26D27D28D29D30D31 A2A3A4A5A6A7A8A9A10A11A12DWE0RAS0CAS0CAS1A2A3A4A5A6A7A8A9A10A11A12DWE0RAS0CAS2CAS3 RAS0CAS0CAS1CAS2CAS3A2A3A4A5A6A7A8A9A10A11A12A13DWE0LEAF0 CS0RD LRDY MWE0TMSTCKTDaTDbTRSTRESCS1 R1091K5 A13A13 R233 1K5 R2342k7 R2421K5 JTAG-BUS JTAG-BUS JTA G D0 3 Q0 2 D1 4 Q1 5 D2 7 Q2 6 D3 8 Q3 9 D4 13 Q4 12 D5 14 Q5 15 D6 17 Q6 16 D7 18 Q7 19 OE 1 LE 11 U116A74LV373 D14D15D16D17D18D19D20D21 A14A15A16A17A18A19A20A21 ALE ALEBLASTDENADS 3 6 RN105C2k7 2 7 RN105B 2k7 4 5 RN105D 2k7 1 8 RN105A 2k7 1 8 RN104A 2k7 3 6 RN104C 2k7 2 7 RN104B 2k7 45 RN104D2k7 R241 2K7 SDA 1 SCL 2 Tout 3 Gnd 4 A2 5 A1 6 A0 7 Vdd 8 U117DS1621S A0 19 A1 20 A2 21 A3 22 A4 23 A5 24 A6 27 A7 28 A8 29 A9 30 A10 31 WE 13 RAS 14 OE 36 UCAS 37 LCAS 38 D0 2 D1 3 D2 4 D3 5 D4 7 D5 8 D6 9 D7 10 D8 41 D9 42 D10 43 D11 44 D12 46 D13 47 D14 48 D15 49 A11 32 NC 33 U114AKM416V4104AS-6 A0 19 A1 20 A2 21 A3 22 A4 23 A5 24 A6 27 A7 28 A8 29 A9 30 A10 31 WE 13 RAS 14 OE 36 UCAS 37 LCAS 38 D0 2 D1 3 D2 4 D3 5 D4 7 D5 8 D6 9 D7 10 D8 41 D9 42 D10 43 D11 44 D12 46 D13 47 D14 48 D15 49 A11 32 NC 33 U115AKM416V4104AS-6 A0 1 A1 2 A3 3 Vss 4 SDA 5 SCL 6 NC 7 Vcc 8 U104 24LC65/SM REDGREEN LED5 R236330 FAI L FAI L D0D1D2D3D4D5D6D7 A2A3A4A5A6A7A8A9A10A11A12A13BE1A14A15A16A17A18 MWE1 MWE0RD FALC INT0FALC INT1FALC INT2FALC INT3XINT6DSPINT0 1 8 RN103A 2 7 3 6 4 5 2K7 DSPINT1 1 8 2 7 3 6 4 5 RN1022K7 BE0 C126100nF A19A20A21 A0 25 A1 24 A2 23 A3 22 A4 21 A5 20 A6 19 A7 18 A8 8 A9 7 A10 6 A11 5 A12 4 A13 3 A14 2 A15 1 A16 48 A17 17 A18 16 DQ0 29 DQ1 31 DQ2 33 DQ3 35 DQ4 38 DQ5 40 DQ6 42 DQ7 44 DQ8 30 DQ9 32 DQ10 34 DQ11 36 DQ12 39 DQ13 41 DQ14 43 Dq15/A1 45 BYTE 47 RESET 12 CE 26 OE 28 WE 11 RY/BY 15 A19 9 NC 10 NC 13 NC 14 U118AAM29LV160B C113100nF Vss Vcc DCLK CS0 Config D28D30D31A2A3 A4 D29 A9 A10A11 A12 A13ALED0D1D2 D3 D4 D5 D6 D7 CLK2M_E LCLK BE0BE1 BE3 BLASTCS1 DEN DSP0RDY DSP1RDY SYNC RD DELTA_ E DSP0CSDSP1CSF ALC _R DF ALC _W RFALC0FALC1FALC2FALC3 LRDYPLLFS_EMWE0SYNCaSCLK2M C107100nF C115100nF TCK_ B TDbTDcTMS R1030R TDbTDc Use L4GL4RL3GL3RL2GL2RL1GL1R L2GL1GL3GL4GL4RL3R L2RL1RE1R ES DSP1RES DSP0RES CS1MWE0 R10712k ConfiguredConfigDCLK Configured R108 330 R1061K5 RCLK2RCLK1RCLK3SCLK8MADSRCLK0SYNC2M D0 RES 1 8 330r 2 7 3 6 4 5 RN100D 1 8 330r 2 7 3 6 4 5 RN101D TDOTDhTDb GND GND GND GND GND GND GND GND GNDGND SCL GND +3.3 +3.3 +3.3 +3.3 +3.3 +3.3 +3.3 +3.3 +3.3 DCLK 128 CON F_D ON E 105 CE 4 CON FIG 53 IO 86 IN 92 IN 17 IN 20 MSEL 33 STA T US 56 TCK 34 CLK USR 100 CS 114 CEO 70 CS 111 DEV_CLR 130 DEV_OE 123 IO 93 IO 43 IO 45 IO 46 IO 71 IO 144 IO 37 IO 24 IO 129 IO 121 IO 136 IO 61 IO 81 IO 82 IO 72 IO 119 IO 132 IO 57 IO 44 IO 122 IO 141 IO 108 IO 143 IO 68 IO 47 IO 124 IO 15 IO 58 IO 63 IO 25 IO 49 IO 51 IO 26 IO 135 IO 69 IO 142 IO 118 IO 116 IO 112 IO 60 IO 59 IO 83 IO 84 IO 22 IO 38 IO 39 IN 89 IO 40 IO 41 IO 66 IO 11 IO 139 IO 10 IO 42 IO 106 IO 21 IO 140 IO 95 IO 87 IO 115 IO 88 IO 138 IO 23 IO 52 IO 50 IO 109 IO 2 IO 14 IO 12 IO 35 IO 48 DATA 125 IO 64 IO 113 IO 131 IO 62 IO 133 IO 67 IO 110 IO 1 IO 36 IO 134 IO 137 IO 16 IO 107 IO 96 IO 85 IO 65 INIT_DONE 94 RD_BSY 97 RS 120 TDI 13 TDO 73 TMS 27 WS 117 U106AEPF6010T(144) D 13 Q0 4 Q1 5 S0 1 Q2 6 S1 2 Q3 7 S2 3 Q4 9 Q5 10 G 14 Q6 11 CLR …

Text truncated - open the document above for the full version.

Test Setup Photos

Photos of test-setup included in Test-report.

Contact Information

Applicant

Eirik Stephansen(VP Engineering)
[email protected](605)348-7650Fax: (605)348-4030

Technical Contact

Comuniq Inc.Bernt A Askildsen
[email protected](605)348-7650

2046 Samco Road · Rapid City, South Dakota · United States

Test Firm

DELTA Electronic TestingJorgen Christensen
[email protected]45-4586-7722Fax: 45-4586-5898

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Comuniq Inc.

PCI-to-PMC Carrier Card - FCC ID OXLPCI-PMC - Comuniq Inc.
OXLPCI-PMC

PCI-to-PMC Carrier Card

Mar 24, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral