1.1. Test Result of RF Exposure Evaluation . Product: Wireless Mouse . Test Item: RF Exposure Evaluation Data . Test site: OATSI-SD . Test Mode: Normal Operation 1.1.1. Antenna Gain The maximum Gain is 1.47 dBi. 1.1.2. EUT Operation condition Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 1.1.3. Output Power into Antenna & RF Exposure Evaluation Distance Modulation Standard: GFSK Test Date: Jan. 25, 2008 Temperature: 25°C Humidity: 60% Channe lChannel Frequency (MHz) Output Power to Antenna (dBm) Power Density (S) (mW/cm 2 ) 01 2402 -46.150.0000000068 08 2439 -45.910.0000000072 16 2479 -46.220.0000000067 The MPE is calculated as 0.0000000072 mW / cm 2 < limit 1 mW / cm 2 . So, RF exposure limit warning or SAR test are not required. For 2402~2479 MHz, the EUT will only be used with a separation of 2.5cm or greater between the antenna and nearby persons and can therefore be considered a mobile transmitter per 47CFR2.1091 (b). The RF Exposure Information page from the manual is included here for reference.
Report No.: NEI-FCCP-1-0801C085 Page 2 of 47 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: NEI-FCCP-1-0801C085 Page 3 of 47 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 15 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 17 4.2.1 RADIATED EMISSION LIMITS 17 4.2.2 MEASUREMENT INSTRUMENTS LIST 18 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 EUT OPERATING CONDITIONS 20 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 21 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 23 4.2.9 TEST RESULTS (2400 – 2483.5 MHz) 35 4.2.10 TEST RESULTS (Restricted Bands Requirements) 36 5 . BANDWIDTH TEST 40 5.1 MEASUREMENT INSTRUMENTS LIST 40 5.2 TEST PROCEDURE 40 5.3 DEVIATION FROM STANDARD 40 5.4 TEST SETUP 40 5.5 EUT OPERATION CONDITIONS 40 5.6 TEST RESULTS 41 Report No.: NEI-FCCP-1-0801C085 Page 4 of 47 Neutron Engineering Inc. Table of Contents Page 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 43 6.1 APPLIED PROCEDURES / LIMIT 43 6.1.1 MEASUREMENT INSTRUMENTS LIST 43 6.1.2 TEST PROCEDURE 43 6.1.3 DEVIATION FROM STANDARD 43 6.1.4 TEST SETUP 43 6.1.5 EUT OPERATION CONDITIONS 44 6.1.6 TEST RESULTS 45 7 . EUT TEST PHOTO 47 Radiated Measurement Photos 47 Report No.: NEI-FCCP-1-0801C085 Page 5 of 47 Neutron Engineering Inc. 1. CERTIFICATION Equipment : Wireless Mouse Trade Name : N/A Model Name. : L167;IVR-61010 A p p l i c a n t : Areson Technology Corporation Date of Test : Jan. 18, 2008~ Jan. 25, 2008 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANCI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-0801C085) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: NEI-FCCP-1-0801C085 Page 6 of 47 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Standard Section Test Item Judgment Remark 15.207 Conducted Emission - N/A 15.249 Radiated Spurious Emission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: NEI-FCCP-1-0801C085 Page 7 of 47 Neutron Engineering Inc. 2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of No.132-1, Lane 329, Sec. 2, Palain Road, Shijr City, Taipei, Taiwan. Neutron's test firm number is 95335 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE OS-01 ANSI30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 OS-02 ANSI30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Report No.: NEI-FCCP-1-0801C085 Page 8 of 47 Neutron Engineering Inc. 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Wireless Mouse Trade Name N/A Model Name. L167;IVR-61010 OEM Brand/Model Name N/A Model Difference This product is defined two different names, but they are in fact the same product. Product Description The EUT is a Wireless Mouse. Product Type Low Power Communication Device Operation Frequency: 2402~2479 MHz Modulation Type: GFSK Number Of Channel 16CH Antenna Designation: Printed antenna Antenna Gain(Peak) 1.47 dBi (Mouse) Output Power: 49.39 dBuV/m (AV Max.) Based on the application, features, or specification exhibited in Us…
Text truncated - open the document above for the full version.
Report No.: NEI-FCCP-1-0801C085 Page 47 of 47 Neutron Engineering Inc. 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode Report No.: NEI-FCCP-1-0801C085 Page 47 of 47 Neutron Engineering Inc. 7. EUT TEST PHOTO Radiated Measurement Photos TX Mode
No.3,JinShaGang 1stRoad, ShiXia, DaLang Town · Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

2.4 GHz Wireless Trackball Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Touch Pad
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Receiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter