FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ARESON Technology Corp./
  3. P5A-CL0005

P5A-CL0005Wireless Mouse

ARESON Technology Corp.
Wireless Mouse - FCC ID P5A-CL0005 - ARESON Technology Corp.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Feb 24, 2008
Application Purpose
Original Equipment
Date of Application
Feb 24, 2008
Equipment Note
Wireless Mouse
Frequency Range
2402.00000000 - 2479.00000000
Company
ARESON Technology Corp.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wheel button/ Dpi switching indicator/ Low power indicator Dpi button ID reset button Mouse Introduction Congratulations on your purchase of the most innovative wireless mouse. With an incredible sensitivity to surface details and high tracking speed than other mice, the mouse can track reliably even on tricky polished or wood-grain surfaces. It offers even more advance that will make you more productive and more comfortable. A. Hardware Installation 2.4GHz (distance 6~8m), 16 Channels/4096 ID Using state-of-art technology. High tracking speed and sensitivity. 4-way scrolling. Rubber side grips and finger grooves. One year battery life. (*Optional for specific laser long-life models) Auto-Link, Plug and Play! No need to set the channel ID. Power on/off switch. Ergonomic design. 800/1600 dpi switchable button. 2*AA Alkaline batteries included. Power on/off switch This product complies with IEC 60825-1, Class I laser product. The product complies with FCC and CE rules. Safety Notice Please DO NOT direct the laser beam at anyone's eyes. Features + - A wrong battery placement may cause batteries overheat. Battery compartment cover 2 * AA batteries Battery cover 2. Connect the receiver a. Turn on your PC. b. Connect the receivere to USB port on PC PC USB port The unit of fers a strong power saving management. Once the mouse accesses the sleeping mode, " to click any button of the mouse" is compulsory to wake it up. Power on/off: There is a Power on/off switch designed to save the batteries power while non-usage of a longer period. User can push DPI button to change the resolution. The LED on scroll wheel will be flashed when dpi has been sucessfully swithced. Internet Forward & Backward button 1. Insert the batteries a. Remove the battery compartment cover on the bottom case of the mouse. b. Fit in the batteries accordingly to the diagram indicated in the battery cabinet. c. Close the battery compartment cover properly. d. Make sure the Power on-off swich on the bottom of the mouse is ON. e. The Low Power LED in the scroll wheel will blink 3 seconds if the mouse power is on. Receiver Led

Users Manual

3. Communication : The mouse & the receiver The 2.4Ghz RF mouse features a dual-way transmission technology which enables the mouse and the receiver auto-communication. A. Auto-link mode 1. Make sure the Power On-Off Switch on the bottom of the mouse is ON. 2. Operate the mouse, and the LED in the receiver will blink fast. Now the mouse and the receiver is auto-linked successfully.. While the mouse is working, if encountering any interference, the mouse and the receiver will automatically source out and transfer to another free channel. During the transferring, the cursor movement may have a second delay. Note 4. Replace the new batteries Please replace a pair of new batteries and follow the previous instructions. (2, 3) The red LED on the scroll wheel is a low batteries power indicator. It indicates that batteries inside the mouse need to be replaced. Note 5. Operation 4-Way Scrolling: a. Vertical Scrolling Roll wheel up to scroll up; roll wheel down to scroll down. b. Horizontal Scrolling Hold the wheel to left to scroll left; hold the wheel to right to scroll right. Release wheel to stop scrolling function. The 4-Way scrolling function is only effective under successful installation of the original mouse driver. The driver is an optional item included in the package or it can be downloaded from the website of your local brand vendor. To function the 4-way scrolling in some applications in Window VISTA such as Word, Excel, Powerpoint and etc., the driver should be installed. Note B. Driver Installation The mouse features plug & play. It is not necessary to install the driver to operate the mouse. The driver is an optional item included. However if the model purchased is with 4- Way Scrolling function, you may require the mouse software driver to make the 4-Way scrolling function effective. 1. Un-install or removing the current mouse driver Before installing the driver of the mouse, we suggest that you check if any other mouse driver installed in your system. If yes, in order not to make conflict, please un-install or remove that driver before installing the mouse. 2. Install the mouse 4-Way Scrolling driver a.Select setup.exe to install the driver from the CD. b.or you can download the 4-Way Scrolling driver from vendor's website. Trouble Shooting a. Make sure you have connected the receiver correctly to the computer's USB port. b. For the best performance, we suggest you to locate the receiver with a distance from other electrical devices, such as the computer, the computer monitor or external storage drives. c. Make sure you have set the communication between the receiver and the mouse. Refer to the channel setting instruction (refer to No. 3) in your manual. d. Some system devices might conflict with the mouse. Confirm the IRQ/address settings of these devices for conflicts, and change the settings as required. e. Make sure that you are not working the mouse on glossy or reflective surfaces. f. Try unplugging then reconnecting the receiver cable to your computer. Battery use reminders 1. Remove worn-out batteries from equipment immediately and dispose of promptly. 2. Keep all batteries (used or new) out of the reach of children. 3. To have the batteries with a regular check and replace new batteries if not used for a long time. 4. Never dispose of batteries in fire, as they could explode. 5. Always replace all the batteries at the same time. Mixing old and new batteries or mining types (such as alkaline with zinc carbon) will reduce overall performance and could cause leakage or rupture. 6. If the lower power indicator is blinking, please change the battery immediately. Otherwise, you may need to reset ID after replacing the battery. 7. Do not mix different types of batteries (e.g. Ni-MH, NiCd, alkaline, and etc) in the mouse. 8. Remove batteries from the electrical device if the device is not going to be used for a long time. 9. If the performance of the batteries decreases substantially, it is time to replace the batteries. Press ID reset button Execute ID connection software Led indicator blinks faster 1 23 4 ID links OK! B. Manual mode If you find the communication channel does not connect well, you can use the software connection tool to re-connect the mouse & receiver to reset a new channel ID. You are able to get the software from the included diskette of the package or download from your local brand vendor's website.

External Photos

Project No.: 0801C121 Page 2 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 2 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 3 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 3 of 15 Neutron Engineering Inc. 0801C121 0801C121

ID Label/Location Info

L190 Laser Wireless Mouse C28 L190 Laser 43.8mm 37mm 19mm 9mm FCC ID : P5A-CL0005 Rating:3V 100mA

Internal Photos

Project No.: 0801C121 Page 4 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 4 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 5 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 5 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 6 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 6 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 7 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 7 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 8 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 8 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 9 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 9 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 10 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 10 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 11 of 15 Neutron Engineering Inc. 0801C121 0801C121 Project No.: 0801C121 Page 11 of 15 Neutron Engineering Inc. 0801C121 0801C121

Test Report

Report No.: NEI-FCCP-1-0801C121 Page 2 of 47 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: NEI-FCCP-1-0801C121 Page 3 of 47 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 15 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 17 4.2.1 RADIATED EMISSION LIMITS 17 4.2.2 MEASUREMENT INSTRUMENTS LIST 18 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 EUT OPERATING CONDITIONS 20 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 21 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 23 4.2.9 TEST RESULTS (2400 – 2483.5 MHz) 35 4.2.10 TEST RESULTS (Restricted Bands Requirements) 36 5 . BANDWIDTH TEST 40 5.1 MEASUREMENT INSTRUMENTS LIST 40 5.2 TEST PROCEDURE 40 5.3 DEVIATION FROM STANDARD 40 5.4 TEST SETUP 40 5.5 EUT OPERATION CONDITIONS 40 5.6 TEST RESULTS 41 Report No.: NEI-FCCP-1-0801C121 Page 4 of 47 Neutron Engineering Inc. Table of Contents Page 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 43 6.1 APPLIED PROCEDURES / LIMIT 43 6.1.1 MEASUREMENT INSTRUMENTS LIST 43 6.1.2 TEST PROCEDURE 43 6.1.3 DEVIATION FROM STANDARD 43 6.1.4 TEST SETUP 43 6.1.5 EUT OPERATION CONDITIONS 44 6.1.6 TEST RESULTS 45 7 . EUT TEST PHOTO 47 Report No.: NEI-FCCP-1-0801C121 Page 5 of 47 Neutron Engineering Inc. 1. CERTIFICATION Equipment : Wireless Mouse Trade Name : N/A Model Name. : L190 A p p l i c a n t : Areson Technology Corporation Date of Test : Jan. 24, 2008~ Feb. 01, 2008 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANCI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-0801C121) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Test result included in this report is only for the Mouse part of the product. Report No.: NEI-FCCP-1-0801C121 Page 6 of 47 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Standard Section Test Item Judgment Remark 15.207 Conducted Emission - N/A 15.249 Radiated Spurious Emission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: NEI-FCCP-1-0801C121 Page 7 of 47 Neutron Engineering Inc. 2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of No.132-1, Lane 329, Sec. 2, Palain Road, Shijr City, Taipei, Taiwan. Neutron's test firm number is 95335 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE OS-01 ANSI30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 OS-02 ANSI30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Report No.: NEI-FCCP-1-0801C121 Page 8 of 47 Neutron Engineering Inc. 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Wireless Mouse Trade Name N/A Model Name. L190 OEM Brand/Model Name N/A Model Difference N/A Product Description The EUT is a Wireless Mouse. Product Type Low Power Communication Device Operation Frequency: 2402~2479 MHz Modulation Type: GFSK Number Of Channel 16CH Antenna Designation: Printed antenna Antenna Gain(Peak) 6.10 dBi (Mouse) Output Power: 50.59 dBuV/m (AV Max.) Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computi…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: NEI-FCCP-1-0801C121 Page 47 of 47 Neutron Engineering Inc. Radiated Measurement Photos TX Mode Report No.: NEI-FCCP-1-0801C121 Page 47 of 47 Neutron Engineering Inc. Radiated Measurement Photos TX Mode

Contact Information

Applicant

Jane Chang(Product Manager)
[email protected]+886-2-29990505Fax: +886-2-29990606

Technical Contact

Neutron Engineering, Inc.Jojo Zhou
[email protected]+86-769-87082000

No.3,JinShaGang 1st Road, ShiXia, DaLang · Dongguan · China

Test Firm

BTL Inc.Andy Yeh
[email protected]+886-2-2641-8198Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from ARESON Technology Corp.

2.4 GHz Wireless Trackball Mouse - FCC ID P5A-CB0033 - ARESON Technology Corp.
P5A-CB0033

2.4 GHz Wireless Trackball Mouse

Nov 22, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Dongle - FCC ID P5A-CL0033 - ARESON Technology Corp.
P5A-CL0033

2.4GHz Wireless Dongle

Apr 13, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Mouse - FCC ID P5A-CB0020 - ARESON Technology Corp.
P5A-CB0020

2.4GHz Wireless Mouse

Apr 13, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Touch Pad - FCC ID P5A-CB0019 - ARESON Technology Corp.
P5A-CB0019

2.4GHz Wireless Touch Pad

Jul 24, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4GHz Wireless Receiver - FCC ID P5A-CL0032 - ARESON Technology Corp.
P5A-CL0032

2.4GHz Wireless Receiver

Jul 07, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter