FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Tokyo Shinyu Co., Ltd./
  3. P5NSWU-T1-01

P5NSWU-T1-01Silwatch Base Transmitter

Tokyo Shinyu Co., Ltd.
Silwatch Base Transmitter - FCC ID P5NSWU-T1-01 - Tokyo Shinyu Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 06, 2002
Application Purpose
Original Equipment
Date of Application
Mar 06, 2002
Equipment Note
Silwatch Base Transmitter
Frequency Range
426.05000000 - 426.05000000
Company
Tokyo Shinyu Co., Ltd.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

JAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, TELEX 242-2531 JQA J FAX (03) 3416-9691 JQA APPLICATION NO.: 400-10613 Issue Date : February 4, 2002 Page 1 of 31 EMI TEST REPORT JQA APPLICATION NO. : 400-10613 Model No. : SWU-T1-01 Type of Equipment : Silwatch Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : P5NSWU-T1-01 Applicant : Tokyo Shinyu Co., Ltd. Address : Shinjuku KM Building, 1-14-5 Shinjuku, Shinjuku-ku, Tokyo 160-0022, Japan Manufacture : Tokyo Shinyu Co., Ltd. Address : Shinjuku KM Building, 1-14-5 Shinjuku, Shinjuku-ku, Tokyo 160-0022, Japan Received date of EUT : December 7, 2001 Final Judgment : Passed Test results in this report are obtained in use of equipment that is traceable to National Institute of Advanced Industrial Science and Technology (AIST) of Japan and Communication Research Laboratory (CRL) of Japan. The test results only respond to the tested sample. This report should not be reproduced except in full, without the written approval of JQA EMC Engineering Dept. Testing Div. C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 2 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 – 8 1.4 EUT Modifications / Deviation from Standard 9 1.5 Test results 10 1.6 Summary 11 1.7 Test Configuration / Operation of EUT 12 1.8 EUT Arrangement(Drawing) 13 1.9 Preliminary Test and Test-setup (Drawings) 14 – 19 1.10 EUT Arrangement (Photographs) 20 - 23 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz – 30 MHz 24 - 25 2.2 Radiated Emission (Electric Field) 26 – 29 2.3 Frequency Stability N/A 2.4 Occupied Bandwidth 30 – 31 C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 3 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and C (June 23, 1989) Intentional Radiators Test procedure : AC power line conducted emission, radiated emission, frequency stability and occupied bandwidth tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at EMC Engineering Dept. Testing Div. : - No.2 and 3 Anechoic Chambers( 3 meters Site ). - Shielded Enclosure. Expiration date of FCC test facility filing : June 04, 2002 2) EMC Engineering Dept. Testing Div. is recognized under the National Voluntary Laboratory accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200189-0 (Effective through : June 30, 2002) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Silwatch 2) Product Type : Production 3) Category : Security/Remote Control Transmitter 4) EUT Authorization : Certification 5) FCC ID : P5NSWU-T1-01 6) Trade Name : Silwatch 7) Model No. : SWU-T1-01 8) Operating Frequency Range : 426.05 MHz 9) Highest Frequency Used in the EUT : 426.05 MHz 10) Serial No. : 10141 11) Date of Manufacture : None 12) Power Rating : DC 3.0V(Battery) or DC 9.0V(External Input) The EUT is operated with the AC adaptor(Model:NP12-1S-0912, Input:120VAC 60Hz, Output:9.0VDC by GO FORWARD ENTERPRISE CORP.). 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 4 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission x - was performed in the following test site. - was not applicable. Test location : Safety & EMC Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan x - Shielded Enclosure - Anechoic Chamber No. 2 (portable Type) Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESH-2 Rohde & Schwarz 880370/016 June 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/030 May 2001 1 Year x - Test Receiver ESHS10 Rohde & Schwarz 835871/004 Aug. 2001 1 Year - LISN(for Peripheral) KNW-407 Kyoritsu Electrical 8-833-6 Apr. 2001 1 Year x - LISN(for EUT) KNW-407 Kyoritsu Electrical 8-855-2 Apr. 2001 1 Year - LISN KNW-407 Kyoritsu Electrical 8-757-1 Apr. 2001 1 Year x - RF Cable 3D-2W Fujikura 155-21-006E0 Apr. 2001 1 Year - RF Cable 3D-2W Fujikura 155-21-007E0 Apr. 2001 1 Year - 50ohm Termination - SUHNER 154-06-501E0 Jan. 2002 1 Year - 50ohm Termination - SUHNER 154-06-502E0 Jan. 2002 1 Year C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 5 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(9 kHz – 30 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety & EMC Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan - Anechoic Chamber No. 2 (3 meters) x - Anechoic Chamber No. 3 (3 meters) Validation of Site Attenuation : 1) Last Confirmed Date : N/A 2) Interval : N/A Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESH-2 Rohde & Schwarz 880370/016 June 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/030 May 2001 1 Year x - Test Receiver ESHS10 Rohde & Schwarz 835871/004 Aug 2001 1 Year x - Antenna HFH2-Z2 Rohde & Schwarz 881058/62 Nov 2001 1 Year x - RF Cable RG-213/U F & G 155-21-01…

Text truncated - open the document above for the full version.

Test Setup Photos

JAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, TELEX 242-2531 JQA J FAX (03) 3416-9691 JQA APPLICATION NO.: 400-10613 Issue Date : February 4, 2002 Page 1 of 31 EMI TEST REPORT JQA APPLICATION NO. : 400-10613 Model No. : SWU-T1-01 Type of Equipment : Silwatch Regulations Applied : CFR 47 FCC Rules and Regulations Part 15 FCC ID : P5NSWU-T1-01 Applicant : Tokyo Shinyu Co., Ltd. Address : Shinjuku KM Building, 1-14-5 Shinjuku, Shinjuku-ku, Tokyo 160-0022, Japan Manufacture : Tokyo Shinyu Co., Ltd. Address : Shinjuku KM Building, 1-14-5 Shinjuku, Shinjuku-ku, Tokyo 160-0022, Japan Received date of EUT : December 7, 2001 Final Judgment : Passed Test results in this report are obtained in use of equipment that is traceable to National Institute of Advanced Industrial Science and Technology (AIST) of Japan and Communication Research Laboratory (CRL) of Japan. The test results only respond to the tested sample. This report should not be reproduced except in full, without the written approval of JQA EMC Engineering Dept. Testing Div. C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 2 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION TABLE OF CONTENTS Page 1 Documentation 1.1 Test Regulation 3 1.2 General Information 3 1.3 Test Condition 4 – 8 1.4 EUT Modifications / Deviation from Standard 9 1.5 Test results 10 1.6 Summary 11 1.7 Test Configuration / Operation of EUT 12 1.8 EUT Arrangement(Drawing) 13 1.9 Preliminary Test and Test-setup (Drawings) 14 – 19 1.10 EUT Arrangement (Photographs) 20 - 23 2 Test Data 2.1 AC Power Line Conducted Emission 0.45 MHz – 30 MHz 24 - 25 2.2 Radiated Emission (Electric Field) 26 – 29 2.3 Frequency Stability N/A 2.4 Occupied Bandwidth 30 – 31 C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 3 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1 DOCUMENTATION 1.1 TEST REGULATION FCC Rules and Regulations Part 15 Subpart A and C (June 23, 1989) Intentional Radiators Test procedure : AC power line conducted emission, radiated emission, frequency stability and occupied bandwidth tests were performed according to the procedures in ANSI C63.4-1992. 1.2 GENERAL INFORMATION 1.2.1 Test facility : 1) Test Facility located at EMC Engineering Dept. Testing Div. : - No.2 and 3 Anechoic Chambers( 3 meters Site ). - Shielded Enclosure. Expiration date of FCC test facility filing : June 04, 2002 2) EMC Engineering Dept. Testing Div. is recognized under the National Voluntary Laboratory accreditation Program for satisfactory compliance established in title 15, Part 285 Code of Federal Regulations. NVLAP Lab Code : 200189-0 (Effective through : June 30, 2002) 1.2.2 Description of the Equipment Under Test (EUT) : 1) Type of Equipment : Silwatch 2) Product Type : Production 3) Category : Security/Remote Control Transmitter 4) EUT Authorization : Certification 5) FCC ID : P5NSWU-T1-01 6) Trade Name : Silwatch 7) Model No. : SWU-T1-01 8) Operating Frequency Range : 426.05 MHz 9) Highest Frequency Used in the EUT : 426.05 MHz 10) Serial No. : 10141 11) Date of Manufacture : None 12) Power Rating : DC 3.0V(Battery) or DC 9.0V(External Input) The EUT is operated with the AC adaptor(Model:NP12-1S-0912, Input:120VAC 60Hz, Output:9.0VDC by GO FORWARD ENTERPRISE CORP.). 13) EUT Grounding : None 1.2.3 Definitions for symbols used in this test report : x - indicates that the listed condition, standard or equipment is applicable for this report. - indicates that the listed condition, standard or equipment is not applicable for this report. C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 4 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3 TEST CONDITION 1.3.1 The measurement of the AC Power Line Conducted Emission x - was performed in the following test site. - was not applicable. Test location : Safety & EMC Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan x - Shielded Enclosure - Anechoic Chamber No. 2 (portable Type) Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESH-2 Rohde & Schwarz 880370/016 June 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/030 May 2001 1 Year x - Test Receiver ESHS10 Rohde & Schwarz 835871/004 Aug. 2001 1 Year - LISN(for Peripheral) KNW-407 Kyoritsu Electrical 8-833-6 Apr. 2001 1 Year x - LISN(for EUT) KNW-407 Kyoritsu Electrical 8-855-2 Apr. 2001 1 Year - LISN KNW-407 Kyoritsu Electrical 8-757-1 Apr. 2001 1 Year x - RF Cable 3D-2W Fujikura 155-21-006E0 Apr. 2001 1 Year - RF Cable 3D-2W Fujikura 155-21-007E0 Apr. 2001 1 Year - 50ohm Termination - SUHNER 154-06-501E0 Jan. 2002 1 Year - 50ohm Termination - SUHNER 154-06-502E0 Jan. 2002 1 Year C O P Y JQA Application No. :400-10613 FCC ID :P5NSWU-T1-01 Model No. :SWU-T1-01 Issue Date :February 4, 2002 Standard :CFR 47 FCC Rules Part 15 Page 5 of 31 JAPAN QUALITY ASSURANCE ORGANIZATION 1.3.2 The measurement of the Radiated Emission(9 kHz – 30 MHz) x - was performed in the following test site. - was not applicable. Test location : Safety & EMC Center EMC Engineering Dept. Testing Div. 21-25, Kinuta 1-chome, Setagaya-ku, Tokyo 157-8573, Japan - Anechoic Chamber No. 2 (3 meters) x - Anechoic Chamber No. 3 (3 meters) Validation of Site Attenuation : 1) Last Confirmed Date : N/A 2) Interval : N/A Used test instruments : Type Model No. Manufacturer Serial No. Last Cal. Interval - Test Receiver ESH-2 Rohde & Schwarz 880370/016 June 2001 1 Year - Test Receiver ESH-3 Rohde & Schwarz 881460/030 May 2001 1 Year x - Test Receiver ESHS10 Rohde & Schwarz 835871/004 Aug 2001 1 Year x - Antenna HFH2-Z2 Rohde & Schwarz 881058/62 Nov 2001 1 Year x - RF Cable RG-213/U F & G 155-21-01…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ken Takanashi(General Manager)
[email protected]81-3-3358-8000Fax: 81-3-3358-6330

Test Firm

Japan Quality Assurance Org.Katsumi Nishii
[email protected]81-727-29-2243Fax: 81-727-28-6848

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231426.05 MHz - 426.05 MHz-

Other Applications from Tokyo Shinyu Co., Ltd.

Silwatch - FCC ID P5NSWU-R1-01 - Tokyo Shinyu Co., Ltd.
P5NSWU-R1-01

Silwatch

Mar 06, 2002

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter