Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
How to use and administer the Kronos InTouch DX timeclock. Kronos InTouch ® DX User Guide: Workforce Dimensions ™ Document Revision: F The information in this document is subject to change without notice and should not be construed as a commitment by Kronos Incorporated. Kronos Incorporated assumes no responsibility for any errors that may appear in this manual. This document or any part thereof may not be reproduced in any form without the written permission of Kronos Incorporated. © 2020 Kronos Incorporated. All rights reserved. CardSaver, Gatekeeper, Gatekeeper Central, Keep.Trac, Kronos, Kronos InTouch, Kronos Touch ID, the Kronos logo, Kronos Workforce Ready, My Genies, OptiLink, ShiftLogic, ShopTrac, Timekeeper Central, TimeLink, Unicru, Visionware, Workforce Accruals, Workforce Central, Workforce Genie, and Workforce TeleTime are registered trademarks of Kronos Incorporated or a related company. ACA Manager, CMS, Comm.Mgr, CommLink, DKC/ Datalink, eDiagnostics, FasTrack, Hireport, HR and Payroll Answerforce, HyperFind, iBid, Kronos 4500, Kronos 4500 Touch ID, Kronos 4510, Kronos Acquisition, Kronos ByDemand, Kronos e-Central, Kronos Efficient, Kronos Enterprise Archive, Kronos Essentials, Kronos for Dining Accelerated, Kronos for Retail Accelerated, Kronos KnowledgePass, Kronos Paragon, Kronos TechKnowledgy, KronosWorks, KVC ByDemand, KVC OnDemand, Labor Plus, MedSched, MPPXpress, Overall Labor Effectiveness, Schedule Assistant, Smart Scheduler, Smart View, StaffEasy, Start Quality, Start WIP, Starter Series, StartLabor, Stromberg, Timekeeper Decisions, Timekeeper Web, VisionPlus, WebStaff, webTA, webTA Mobile, Winstar Elite, WIP Plus, Workforce Absence Manager, Workforce Acquisition, Workforce Activities, Workforce Analytics, Workforce Attendance, Workforce Auditor, Workforce Budgeting, Workforce Central Portal, Workforce Connect, Workforce Device Manager, Workforce Dimensions, Workforce Employee, Workforce ESP, Workforce Forecast Manager, Workforce HR, Workforce Innovation That Works, Workforce Institute, Workforce Integration Manager, Workforce IntegrityScreen, Workforce Leave, Workforce Manager, Workforce Mobile, Workforce MobileTime, Workforce Operations Planner, Workforce Payroll, Workforce Record Manager, Workforce Recruiter, Workforce Scheduler, Workforce Scheduler with Optimization, Workforce Selection, Workforce Smart Scheduler, Workforce Sourcing Analytics, Workforce Tablet, Workforce Tablet Analytics, Workforce Talent Acquisition, Workforce Task Management, Workforce Tax Filing, Workforce TeleStaff, Workforce TeleTime IP, Workforce Timekeeper, Workforce View, and Workforce Worksheet are trademarks of Kronos Incorporated or a related company. For a complete list of Kronos trademarks, please visit the "trademarks" page at www.kronos.com. The source code for Equinox is available for free download at www.eclipse.org. All other trademarks or registered trademarks used herein are the property of their respective owners and are used for identification purposes only. All specifications are subject to change. When using and applying the information generated by Kronos products, customers should ensure that they comply with the applicable requirements of all applicable law, including federal and state law, such as the Fair Labor Standards Act. Nothing in this Guide shall be construed as an assurance or guaranty that Kronos products comply with any such laws. Published by Kronos Incorporated 900 Chelmsford Street, Lowell, Massachusetts 01851 USA Phone: 978-250-9800, Fax: 978-367-5900 Kronos Incorporated Global Support: 1-800-394-HELP (1-800-394-4357) For links to information about international subsidiaries of Kronos Incorporated, go to http://www.kronos.com Note: To view or print other language versions of this guide, access the customer web site or contact your representative. Nota: Para ver o imprimir versiones de esta guía en otro idioma, acceda al sitio web del cliente o comuníquese con su representante. Remarque : Pour afficher ou imprimer ce guide en d'autres langues, accédez au site Web client ou contactez votre représentant. FCC Notice (for U.S. Customers)—This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes and modifications not expressly approved by Kronos Incorporated can void your authority to operate this equipment under Federal Communications Commissions rules. Canadian DOC Compliance—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. EN 55032 (CISPR 32)—This product is a Class A product. In a domestic environment, it may cause radio interference in which case the user may be required to take adequate measures. RoHS Directive—This data collection device and all hardware options currently qualified to work with this device are designed in accordance with the restricted substance requirements of Directive 2002/95/EC and 2011/65/EU of the European Parliament and of the Council of the European Union, including Commission Delegated Directive (EU) 2015/863 amending Annex II of the Directive. The RoHS directive prohibits the sale of electronic equipment containing certain hazardous substances such as cadmium (Cd), lead (Pb), mercur…
Text truncated - open the document above for the full version.
�KRONOS ® � Kronos Incorporated 900 Chelmsford Street Lowell, MA 01851 Subject: Model similarity for 8610000-009, 8610000-109, 8610000-409 To Whom it may concern, phone +1978250 9800 fax +1 978 367 5900 url www.kronos.com May 07, 2021 The models 8610000-009, 8610000-109, 8610000-409 are electrically identical, the only differences are model name for marketing purposes. Sr. Director of Engineering
EUT View 1 EUT View 2
Labels for 8610000-009: Terminal Packaging Labels for 8610000-109: Terminal Packaging Labels for 8610000-109: Terminal Packaging
Product Label FCC Label Compliance Label
EUT – Uncover View PCB1 Front View PCB1 Rear View PCB2 Front View PCB2 Rear View PCB3 Front View PCB3 Rear View Power Adapter View
Report No.: FCC_RF Exposure_SL20103001-KRO-111 Page No. 1 / 6 Report Format Version: 6.1.1 RF Exposure Report Report No.: FCC_RF Exposure_SL20103001-KRO-111 FCC ID: P5W-8610K009 Test Model: InTouch DX with Legic Part Numbers: 8610000-009, 8610000-109, 8610000-409 Received Date: 11/20/2020 Test Date: 11/25/2020-12/12/2020 Issued Date: 05/03/2021 Applicant: Kronos, Inc Address: 900 Chelmsford Street, Lowell MA 01851 Manufacturer: Kronos, Inc Address: 900 Chelmsford Street, Lowell MA 01851 Issued By: Bureau Veritas Consumer Products Services, Inc. Lab Address: 775 Montague Expressway, Milpitas, CA 95035 Test Location (1): 775 Montague Expressway, Milpitas, CA 95035 FCC Registration / Designation Number: 540430 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any government agencies. Report No.: FCC_RF Exposure_SL20103001-KRO-111 Page No. 2 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 3 1 Certificate of Conformity ................................................................................................................... 4 2 Evaluation Result ............................................................................................................................... 5 3 SAR Test Exclusion Thresholds ....................................................................................................... 6 4 Conclusion ......................................................................................................................................... 6 Report No.: FCC_RF Exposure_SL20103001-KRO-111 Page No. 3 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued FCC_RF Exposure_SL20103001-KRO-111 Orignal Release 05/03/2021 Report No.: FCC_RF Exposure_SL20103001-KRO-111 Page No. 4 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Legic Card Reader Brand: Kronos, Inc Test Model: InTouch DX with Legic Part Numbers: 8610000-009, 8610000-109, 8610000-409 Sample Status: Engineering sample Applicant: 900 Chelmsford Street, Lowell MA 01851 Test Date: 1/25/2020-12/12/2020 Standards: FCC Part 2 (Section 2.1093) KDB 447498 D01 General RF Exposure Guidance v06 IEEE C95.1-1992 The above equipment has been tested by Bureau Veritas Consumer Products Services, Inc., Milpitas Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. Prepared by : , Date:05/03/2021 Gary Chou / Compliance Engineer Approved by : , Date:05/03/2021 Deon Dai / Engineer Reviewer Report No.: FCC_RF Exposure_SL20103001-KRO-111 Page No. 5 / 6 Report Format Version: 6.1.1 2 Evaluation Result Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ꞏ[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation. The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)ꞏ( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)ꞏ10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test…
Text truncated - open the document above for the full version.
Report No.: RF_ FCC_IC_SL20103001-KRO-111 Rev_2.0 Page No. 1 / 28 Report Format Version: 6.1.1 FCC IC RF Test Report Report No.: RF_ FCC_IC_SL20103001-KRO-111 Rev_1.0 FCC ID: P5W-8610K009 IC: 1416A-8610K009 Models: InTouch DX with Legic Part Numbers: 8610000-009, 8610000-109, 8610000-409 Received Date: 11/20/2020 Test Date: 11/25/2020-05/13/2021 Issued Date: 05/13/2021 Applicant name: Kronos, Inc Address: 900 Chelmsford Street, Lowell MA 01851 Manufacturer: Kronos, Inc Address: 900 Chelmsford Street, Lowell MA 01851 Issued By: Bureau Veritas Consumer Products Services, Inc. Lab Address: 775 Montague Expressway, Milpitas, CA 95035 FCC Registration / Designation Number: 540430 ISED# / CAB identifier: 4842D This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any government agencies. Report No.: RF_ FCC_IC_SL20103001-KRO-111 Rev_2.0 Page No. 2 / 28 Report Format Version: 6.1.1 Table of Contents Release Control Record ............................................................................................................................... 3 1 Certificate of Conformity ................................................................................................................... 4 2 Summary of Test Results .................................................................................................................. 5 2.1 Measurement Uncertainty ................................................................................................................. 5 2.2 Modification Record .......................................................................................................................... 5 3 General Information ........................................................................................................................... 6 3.1 General Description of EUT .............................................................................................................. 6 3.2 Description of Test Modes ................................................................................................................ 7 3.2.1 1 channel is provided to this EUT ..................................................................................................... 7 3.2.2 Test Mode Applicability and Tested Channel Detail ........................................................................... 7 3.3 Description of Support Units ............................................................................................................. 8 3.3.1 Configuration of System under Test .................................................................................................. 8 3.4 General Description of Applied Standards ........................................................................................ 8 4 Test Types and Results ...................................................................................................................... 9 4.1 Radiated Emission Measurement ..................................................................................................... 9 4.1.1 Limits of Radiated Emission Measurement ....................................................................................... 9 4.1.2 Test Instruments ............................................................................................................................. 10 4.1.3 Test Procedures ............................................................................................................................... 11 4.1.4 Deviation from Test Standard ........................................................................................................... 11 No deviation. .............................................................................................................................................. 11 4.1.5 Test Setup ....................................................................................................................................... 12 4.1.6 EUT Operating Conditions .............................................................................................................. 12 4.1.7 Test Results .................................................................................................................................... 13 4.2 Conducted Emission Measurement ................................................................................................ 19 4.2.1 Limits of Conducted Emission Measurement .................................................................................. 19 4.2.2 Test Instruments ........................................................................................................................…
Text truncated - open the document above for the full version.
Conducted Emission Test Front View Conducted Emission Test Rear View Radiated Emission Test below 30MHz Front View Radiated Emission Test below 30MHz Rear View Radiated Emission Test 30MHz-1GHz Front View Radiated Emission Test 30MHz-1GHz Rear View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Time Clock with HID 125 kHz Prox Card
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Time Clock with HID 13.56 MHz Smart Card
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID READER 13.56 MHz IN TOUCH DATA COLLECTIVE DEVICE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID READER HID 125 KHz; INTOUCH DATA COLLECTION DEVICE
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
PASSIVE TAG TRANSMITTER FEIG 125 KHz; INTOUCH DATA COLLECTIVE DEVICE
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz