P6ZCI00066Base Station 100W VHF

Westel Wireless Systems Pty Ltd
Base Station 100W VHF - FCC ID P6ZCI00066 - Westel Wireless Systems Pty Ltd
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Dec 14, 2004
Application Purpose
Original Equipment
Date of Application
Dec 14, 2004
Equipment Note
Base Station 100W VHF
Frequency Range
136.00000000 - 174.00000000
Company
Westel Wireless Systems Pty Ltd
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗
↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗

Operational Description

Parts List/Tune Up Info

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DRB-25 Digital Mobile Radio Repeater and Radio Base Station Installation and Operator Handbook AMX-MA-00400 Issue 0.13 (USA) Date of Issue: 16 March 2004 AMX–MA–00400 Issue 0.13 (USA) ii As part of its ongoing commitment to product improvement, The Westel Group reserves the right to alter at any time the equipment and specifications described in this publication. All performance figures quoted are typical and are subject to normal manufacturing and service tolerances. The purchaser is warned that the statements made in this publication may be inaccurate due to typographical or other errors or subsequent modification of the products described herein. Whilst every care has been taken in the preparation of this publication, no warranty of accuracy or reliability is given in relation to any advice or information contained in this publication and no responsibility for any loss or damage whatsoever arising in any way for any representation, act or omission whether express or implied (including responsibility to any person by reasons of negligence) is accepted by The Westel Group or any officer, agent, or employee of it.  The Westel Group, 2000. This work is copyright. Other than as permitted by law, no part of it may be reproduced, stored in a retrieval system or transmitted in any form or by any process without prior written permission. This device made under license under one or more of the following US patents: 5,164,986; 5,146,497; 5,185,795, 4,636,791; 4,590,473; 5,185,796; 5,148,482; 5,271,017; 5,377,229; 4,833,701; 4,972,460; 5,651,030. Other worldwide patents pending. The IMBE TM voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. The voice coding technology can be used only as part of the North American land mobile communications system for APCO Project 25. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into a human readable form. AMX–MA–00400 Issue 0.13 (USA) iii PREFACE This manual provides the information personnel will need to install and operate the DRB-25 Dual Channel Radio Base Station. The manual consists of nine documents, as described below: Title Document Ref Issue Date Preliminary Pages AMX-MA-00400 0.13 16 March 2004 1 Introduction AMX-MA-00651 0.04 24 July 2003 2 Equipment Description AMX-MA-00652 0.04 24 July 2003 3 Installation Instructions AMX-MA-00653 0.06 16 March 2004 4 Operating Instructions AMX-MA-00654 0.03 24 July 2003 5 Programming and Configuration AMX-MA-00657 1.04 24 July 2003 6 Diagnostics Monitor AMX-MA-00656 0.02 30 March 00 Appendix A Box ID and Transceiver Default Channel Settings AMX-MA-00658 0.02 30 March 00 Appendix B Module Error Codes and Recommended Actions AMX-MA-00659 0.02 30 March 00 Definitions of warnings, cautions and notes are shown on the next page. Safety of personnel and equipment depends upon adherence to these precautions. FCC Interference Warning This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this device does not cause harmful interference. For specific instructions regarding antenna safety and safe operating distances see Chapter 3. AMX–MA–00400 Issue 0.13 (USA) iv PRECAUTIONARY NOTATIONS Where it is necessary to highlight a potentially hazardous situation, a critical procedure or requirement, or an important fact, the appropriate precautionary notation is used: WARNING A WARNING PRECEDES A PRACTICE OR PROCEDURE WHICH, IF NOT CORRECTLY FOLLOWED, COULD RESULT IN PERSONAL INJURY OR LOSS OF LIFE. A caution precedes a practice or procedure which, if not strictly observed, could result in damage to or destruction of the equipment, or corruption of data. ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES A caution for static devices precedes a practice or procedure which, if not strictly observed, could result in damage to or destruction of the equipment, or corruption of data. NOTE A note either precedes or follows a practice, procedure or condition which requires highlighting. AMX–MA–00400 Issue 0.13 (USA) v LIST OF ABBREVIATIONS AC Alternating Current APCO Association of Public-Safety Communications Officials - International, Inc. BER Bit Error Rate CAI Common Air Interface CM Controller Module CDCSS Continuous Digital Carrier Squelch System Comms Communications CTCSS Continuous Tone Carrier Squelch System DC Direct Current DMR Digital Mobile Radio DTMF Dual Tone Multiple Frequency EMC Electromagnetic Compatibility EMI Electromagnetic Interference IAC Interface Adapter Card IM Interface Module kHz Kilohertz LCD Liquid Crystal Display LED Light Emitting Diode MHz Megahertz PAM Power Amplifier Module PA PSM Power Amplifier Power Supply Module PABX Private Automatic Branch Exchange PBX Private Branch Exchange PC Personal Computer PCA Printed Circuit Assembly PSTN Public Switched Telephone Network PTT Press-to-talk RF Radio Frequency RU Rack Unit Rx Receive TM Transceiver Module TMP Transceiver Module Programmer Tx Transmit UHF Ultra High Frequency V Volt VHF Very High Frequency W Watt

Block Diagram

Installation and Operator Handbook Introduction AMX–MA–00651 Issue 0.04 (USA) 5 • One Transceiver Module. • One Power Amplifier Module. • One Power Supply Module. • One Interface Module (Optional - depending on external interfaces). A dual-channel DRB-25 requires one Controller (or Repeater) Module and the following plug-in modules: • Two Transceiver Modules. • Two Power Amplifier Modules. • Two Power Supply Modules. • One Interface Module (Optional - depending on external interfaces). A single-channel DRB-25 can be easily and inexpensively converted to a dual-channel DRB-25 by the installation of the additional modules. The DRB-25 may be configured for AC or DC power, or as AC power with DC revert in the case of AC power failure. A block diagram of a DRB-25 is shown in Figure 1-3. System Power Supply Backplane Transceiver Module Transceiver Module Controller /Repeater Module Power Supply Module Power Amplifier Module Power Supply Module Power Amplifier Module Interface Module (external interfaces) Fan Module Radio 1Antenna Connections Radio 2 Antenna Connections AC/DC Power Figure 1-3 Block Diagram - DRB-25

Cover Letter(s)

14th June 2004 Federal Communications Commission EQUIPMENT APPROV AL SERVICES PO Box 358315 Pittsburgh, PA 15251-5315 Attention: Authorisation and Evaluation Division Reference: FCC ID: P6ZCIOOO66; Model: DRB-25 Pursuant to Sections 0.457 (d)(l)(ii) and 0.459 of the Commission's Rules the Applicant hereby requests confidential treatment of some of the information accompanying this Application, specifically Circuit and Schematic Diagrams and Parts Lists as listed below: I I. Circuit and Schemati~~1 Doc. Number AMX -CD-OO948 AMX-CD-OO528 AM X -CD-O 1584 AMX-CD-OO633 AMX-CD-OlO33 AMX-CD-OlO34 AMX-CI-OOO6O Issue 2.02 3.00 1.01 2.01 1.02 1.00 1.00 I Transceiver Module RF Card I Tranceiver Module Di~ital Card PAModule Controller Module Interface Module 4W Card Power SuDDly 12. Parts~ Doc. Number AMX-PL-O3304 AMX-PL-O3303 AMX-PL-O6595 AMX-PL-Q3294 AMX-PL-O3302 AMX-PL-O3300 Issue 2.00 3.04 1.00 2.01 1.02 1.00 I Transceiver Module RF Card I Tranceiver Module Dieital Card PAModule Controller Module Interface Module 4W Card WESTEL GROUP LIMITED These materials are trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. ACN 062879583 The Applicant understands that pursuant to Rule 0.457 (d)(l)(ii), disclosure of the Application and all accompanying documentation will not be made before the date of the Grant for this Application. uvel13 15 Blue Street Sydney NSW 2060 Australia Sincerely, Westel Wireless Systems Telephone 61294926161 Facsimile 61294926162 ~l~ Steve Tucker CTO Web site: www.westel.com.au

Cover Letter(s)

14th June 2004 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Gentlemen: Reference:P6ZCIOOO66 This equipment meets the requirements of the FCC Rules, Parts 90.203( e ) and (g), as applicable. Yours Sincerely, Westel Wireless Systems WESTEL GROUP LIMITED ACN 062879583 "' ~l..,£ Steve Tucker Chief Technical Officer uvel13 15 Blue Stteet Sydney NSW 2060 Ausb"alia Telephone 61294926161 Facsimile 61294926162 Web site. www.westel.com.au

ID Label/Location Info

WESTEL WIRELESS SYSTEMS PTY LTD A.B.N. 61 054 645 000 FCC ID: P6ZCI00066 Model: DRB-25 S/N L1D27xxxxxx MANUFACTURED UNDER ONE OR MORE AUSTRALIAN, UNITED STATES OR OTHER WORLDWIDE PATENTS AS IDENTIFIED IN THE OPERATOR’S MANUAL. MADE IN AUSTRALIA

RF Exposure Info

M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Date of Report: Date of Submission: September 29, 2004 December 13, 2004 Applicant: Westel Wireless Systems Pty Ltd Level 13, 15 Blue Street North Sydney, Australia NSW 2060 Attention of: Steve Tucker, CTO email: [email protected] +61 2 9492 6161; FAX: -6162 Mailing: Comserv, Inc. 895 N. White Station Road Memphis, TN 38122-3021 (901) 767-6800; FAX: -4555 Attention of: Ken Hunt, Director, Technical Services (901) 681-1716 (direct); (901) 226-7211 (pager) E-mail: [email protected] Equipment: DRB-25 FCC ID: P6ZCI00066 P.O. Number: WWS DMR PO 4026 FCC Rules: Radiofrequency Radiation Exposure Limits 47 CFR 1.1310 MPE - Mobiles Fixed Based Station X Gentlemen: Enclosed please find your copy of the Supplemental Test Data Report, the whole for Environmental Assessment (MPE) of the referenced equipment as shown. Should you need any clarification, just fax or phone. Thank you again for this order - it has been a pleasure to be of service. Sincerely yours, David E. Lee, Compliance Test Manager enclosure(s) DEL/del M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Date of Report: Date of Submission: September 29, 2004 December 13, 2004 Federal Communications Commission Via: Electronic Filing Attention: Authorization & Evaluation Division Applicant: Westel Wireless Systems Pty Ltd Equipment: DRB-25 FCC ID: P6ZCI00066 FCC Rules: Radiofrequency Radiation Exposure Limits 47 CFR 1.1310 MPE - Mobiles Fixed Based Station X Gentlemen: On behalf of the Applicant, enclosed please find the Supplemental Test Data Report, the whole for Environmental Assessment (MPE) of the referenced equipment as shown. We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized to act as agent. Sincerely yours, David E. Lee, Compliance Test Manager enclosure(s) cc: Applicant DEL/del M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Environmental Assessment for Fixed Base Station for FCC ID: FCC ID: P6ZCI00066 Model:DRB-25 to Federal Communications Commission 47 CFR 1.1310 (MPE) Radiofrequency Radiation Exposure Limits Date Of Report: September 29, 2004 On the Behalf of the Applicant: Westel Wireless Systems Pty Ltd At the Request of: P.O. WWS DMR PO 4026 Comserv, Inc. 895 N. White Station Road Memphis, TN 38122-3021 (901) 767-6800; FAX: -4555 Attention of: Ken Hunt, Director, Technical Services (901) 681-1716 (direct); (901) 226-7211 (pager) E-mail: [email protected] Supervised By: David E. Lee, Compliance Test Manager M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Table of Contents Rule Description Page . Test Report 1 . Identification of the Equipment Under Test 2 . Standard Test Conditions and Engineering Practices 4 1.1310 Environmental Assessment 5 M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Page 1 of 8 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Required information per ISO/IEC Guide 25-1990, paragraph 13.2: a) Test Report (Supplemental) b) Laboratory: (FCC: 31040/SIT) (Canada: IC 2044) M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, AZ 85225 c) Report Number: d0490063 d) Client: Comserv, Inc. 895 N. White Station Road Memphis, TN 38122-3021 (901) 767-6800; FAX: -4555 e) Identification: DRB-25 FCC ID: P6ZCI00066 Description: Base Station (100W VHF) f) EUT Condition: Not required unless specified in individual tests. g) Report Date: September 29, 2004 EUT Received: July 30, 2004 h, j, k): As indicated in individual tests. i) Sampling method: No sampling procedure used. l) Uncertainty: In accordance with MFA internal quality manual. m) Supervised by: David E. Lee, Compliance Test Manager n) Results: The results presented in this report relate only to the item tested. o) Reproduction: This report must not be reproduced, except in full, without written permission from this laboratory. M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Page 2 of 8 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 Identification of the Equipment Under Test (EUT) Name and Address of Applicant: Westel Wireless Systems Pty Ltd Level 13, 15 Blue Street North Sydney, Australia NSW 2060 Manufacturer: Westel Wireless Systems Pty Ltd Level 13, 15 Blue Street North Sydney, Australia NSW 2060 FCC ID: P6ZCI00066 Model Number: DRB-25 Description: Base Station (100W VHF) Type of Emission: 16K0F3E, 11K0F3E, 8K10F1E, 8K10F1D Frequency Range, MHz: 136 to 174 Power Rating, Watts: 100 Switchable X Variable N/A Modulation: AMPS TDMA CDMA X OTHER Antenna: Helical Monopole X Whip Other Note: For RF Safety test antenna gain taken at the upper range of expected gain (i.e. 0 dBd) and RF Power set to highest nominal power across all channels. M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Page 3 of 8 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d04900633 A2LA “A2LA has accredited M. Flom Associates, Inc. Chandler, AZ for technical competence in the field of Electrical Testing. The accreditation covers the specific tests and types of tests listed on the agreed scope of accreditation. This laboratory meets the requirements of ISO/IEC 17025 – 1999 ‘General Requirements for the Competence of Testing and Calibration Laboratories’ and any additional program requirements in the identified field of testing.” Certificate…

Text truncated - open the document above for the full version.

Test Report

M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d0490067 Date of Report: Date of Submission: September 29, 2004 December 13, 2004 Federal Communications Commission Via: Electronic Filing Attention: Authorization & Evaluation Division Applicant: Westel Wireless Systems Pty Ltd Equipment: DRB-25 FCC ID: P6ZCI00066 FCC Rules: 2, 90, 95, Confidentiality Gentlemen: On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report and all pertinent documentation, the whole for approval of the referenced equipment as shown. Filing fees are attached. We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized to act as agent. Sincerely yours, David E. Lee, Lab Manager enclosure(s) cc: Applicant DEL/ca M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d0490067 Transmitter Certification of FCC ID: P6ZCI00066 Model: DRB-25 to Federal Communications Commission Rule Part(s) 2, 90, 95, Confidentiality Date of report: September 29, 2004 On the Behalf of the Applicant: Westel Wireless Systems Pty Ltd At the Request of: P.O. WWS DMR PO 4026 Comserv, Inc. 895 N. White Station Road Memphis, TN 38122-3021 (901) 767-6800; FAX: -4555 Attention of: Ken Hunt, Director, Technical Services (901) 681-1716 (direct); (901) 226-7211 (pager) E-mail: [email protected] Supervised by: David E. Lee, Lab Manager M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d0490067 List of Exhibits (FCC Certification (Transmitters) - Revised 9/28/98) Applicant: Westel Wireless Systems Pty Ltd FCC ID: P6ZCI00066 By Applicant: 1. Letter of Authorization 2. Confidentiality Request: 0.457 And 0.459 3. Part 90.203(e) & (g) Attestation 4. Identification Drawings, 2.1033(c)(11) Label Location of Label Compliance Statement Location of Compliance Statement 5. Photographs, 2.1033(c)(12) 6. Documentation: 2.1033(c) (3) User Manual (9) Tune Up Info (10) Schematic Diagram (10) Circuit Description Block Diagram Parts List Active Devices 7. MPE Report By M.F.A. Inc.: A. Testimonial & Statement of Certification M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d0490067 The Applicant has been cautioned as to the following: 15.21 Information to the User. The users manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.27(a) Special Accessories. Equipment marketed to a consumer must be capable of complying with the necessary regulations in the configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of ensuring that the special accessories are provided to the consumer, without additional charge. Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in § 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such devices shall include appropriate instructions on the first page of text concerned with the installation of the device that these special accessories must be used with the device. It is the responsibility of the user to use the needed special accessories supplied with the equipment. M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, fax (480) 926-3598 MFA p0470015, d0490067 Table of Contents Rule Description Page 2.1033(c)(14) Rule Summary 2 . Standard Test Conditions and Engineering Practices 3 2.1033(c) General Information Required 5 2.1046(a) Carrier Output Power (Conducted) 8 2.1046(a) ERP Carrier Power (Radiated) 10 2.1051 Unwanted Emissions (Transmitter Conducted) 12 2.1053(a) Field Strength of Spurious Radiation 14 2.1049(c)(1) Emission Masks (Occupied Bandwidth) 18 90.214 Transient Frequency Behavior 29 2.1047(a) Audio Low Pass Filter (Voice Input) 35 2.1047(a) Audio Frequency Response 37 2.1047(b) Modulation Limiting 39 2.1055(a)(1) Frequency Stability (Temperature Variation) 42 2.1055(b)(1) Frequency Stability (Voltage Variation) 44 2.202(g) Necessary Bandwidth and Emission Bandwidth 46 M. Flom Associates, Inc. 3356 North San Marcos Place, Suite 107 Page 1 of 46 Chandler, Arizona 85225-7176 FCC ID: P6ZC100066 (480) 926-3100 phone, (480) 926-3598 fax MFA p0470015, d0490067 Required information per ISO/IEC Guide 25-1990, paragraph 13.2: a) Test Report b) Laboratory: (FCC: 31040/SIT) (Canada: IC 2044) M. Flom Associates, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, AZ 85225 c) Report Number: d0490067 d) Client: Comserv, Inc. 895 N. White Station Road Memphis, TN 38122-3021 (901) 767-6800; FAX: -4555 e) Identification: DRB-25 FCC ID: P6ZCI00066 EUT Description: Base Station (100W VHF) f) EUT Condition: Not required unless specified in individual tests. g) Report Date: September 29, 2004 EUT Received: June 23, 2004 h, j, k): As indicated in individual tests. i) Sampling…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Steve Tucker(Chief Technical Officer)
[email protected]61 2 9948 6564Fax: 61 2 9948 9832

Test Firm

M. Flom Associates, Inc.Morton Flom
[email protected]480-926-3100Fax: 480-926-3598

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
49136 MHz - 174 MHz100 W8K10F1D5 ppm
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 70cm from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 100 W and the peak radiated output power must not exceed 164 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of �1.1307(b)(3), for satisfying RF exposure compliance.

Other Applications from Westel Wireless Systems Pty Ltd

UHF BASE STATION TRANSCEIVER - FCC ID P6ZCI00063 - Westel Wireless Systems Pty Ltd
P6ZCI00063

UHF BASE STATION TRANSCEIVER

Aug 21, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
UHF Base Station Transceiver - FCC ID P6ZC100063 - Westel Wireless Systems Pty Ltd
P6ZC100063

UHF Base Station Transceiver

Jul 30, 2003

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter