Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 03, 2002
Application Purpose
Original Equipment
Date of Application
Jun 03, 2002
Equipment Note
Model SAVE-T Cover II pool cover controller
Frequency Range
916.50000000 - 916.50000000
Company
Cover Pools, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Touch Pad Pre-wiring Instructions Description: The Touch Pad sends a digital signal to the cover receiver unit which is mounted in the cover housing. The signal is received through the remote antenna that is connected to the receiver board. The Touch Pad must be located in line of sight of the antenna. (See "Wireless Touch Pad Placement and Antenna Mounting" instructions.) There are no wires required to be run to the Touch Pad, it is powered by a long life lithium battery with a 5 year life expectancy. Only power wires need to be run to the receiver board and the receiver board is wired to the pool cover motor or hydraulic pump motor. Touch Pad: The Touch Pad is operated by pushing and holding either the cover, or uncover buttons. The Touch Pad can be locked off or on with the lock provided. Up to 3 Touch pads may be installed to operate the same cover. Touch Pad Mounting: The Touch Pad comes in a 2" x 4" bezel mounted in a separate standoff box. The Touch Pad can be mounted in a standard recessed wall box if you choose. The Touch Pad must be mounted in full view of the pool cover and must be 5 feet above the deck to meet codes. Hydraulic Installations: Hydraulic power units are typically mounted in a remote location from the pool. Your power wires for the Touch Pad will run to the hydraulic power unit location. The antenna attached to the receiver board must be located in line of site with the Touch Pad for reception. The antenna has a 10 ft cord and may be able to be mounted in a good reception location. If not the receiver will have to be extended away from the hydraulic system until the antenna is in a good reception location. Do not cut or extend the antenna wire. It has been tuned for a specific length and will not work if changed. Electrical Requirements: 120 V AC dedicated line from 15 amp G.F.C.I. 3# 14 AWG wires, hot, neutral and ground. (Run's longer than 50 ft, may require larger wires.) Conduit from breaker must terminate in motor side of housing with at least 3 feet of flex conduit plus wires. POOL COVER HOUSING Extend 3 feet of seal tight flex conduit in to housing. Provide 3 # 14 AWG wires hot, neutral, ground. To 120 VAC dedicated 15 amp G.F.C.I circuit motor copyright Cover Pools Inc. 2000 * 66 East 3335 South Salt Lake City, UT 84115 * 801-484-2724 Fax 801-484-2763 * www.coverpools.com HYDRAULIC PUMP UNIT TANK antenna remote mounted receiver equiptment room SAVE-T COVER II cover uncover R off on cover-pools, inc. touch pad clea r lin e o f r eception Rev. 1 May 02 Page 1 Installation / Owners Manual Antenna Programming Button LED Black Green / Ground White / Neutral Black / Red strp White BlueYellowBlack Red Relay Motor Connection Wires Your Wireless Touch Pad comes to you Pre-programmed. If the System is not operating properly, follow this procedure. TO CLEAR MEMORY: Step 1: Circuit Breaker: β€˜OFF’ Step 2: Orange Button (in Receiver Box): hold down three seconds as the Circuit Breaker is switched on – this is a concurrent event. This will clear the memory. TO PROGRAM THE RECEIVER TO TOUCH PAD: Step 1: Power to the Pool Cover β€˜ON’ Step 2: Touch Pad Key: β€˜ON’ position Step 3: Hold the orange button down for 3 seconds as either Touch Pad button is held so the LED flashes. This is a concurrent event. This will complete the programming. PROGRAMMING a 2 ND or 3 rd TOUCH PAD: (Up to 3 Touch Pads can be programmed to run cover.) Repeat step 1 & 2 for programming as described above. This will complete the programming of the second Touch Pad. Repeat procedure for 3 rd Touch Pad. LED FUNCTIONS: Touch Pad LED flashes during transmission. Receiver LED flashes when receiving a signal. Note: If Receiver LED flashes but the cover does not move, clear the memory and reprogram the Touch Pad. It is not abnormal for the LED to flash intermittently. Wireless Touch Pad Control Programming Instructions cover uncover off on cover-pools, inc. Touch Pad #050133 Receiver Kit (at Motor) #050138 (120V) or #050143 (240V) Antenna Programming Button LED Black Green / Ground White / Neutral Black / Red strp White BlueYellowBlack Red Relay Motor Connection Wires Rev . 1 May02 Page 2 Installation / Owners Manual This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. Changes or modifications to SAVE-T COVER II WIRELESS CONTROL not expressly approved in writing by Cover Pools Incorporated could void the user's authority to operate this product. copyright Cover Pools Inc. 2000 * 66 East 3335 South Salt Lake City, UT 84115 * 801-484-2724 Fax 801-484-2763 * www.coverpools.com Wireless Touch Pad Placement and Antenna Mounting Mounting locations for Aluminum Lid - Bench - Hydraulic systems The antenna for the Wireless Touch Pad receiver is mounted on top of the aluminum lid or outside the bench assembly. The antenna has a 10 ft. cable and can be extended out to a clear line of reception. Never cut the antenna cable. On aluminum lids the antenna should be mounted on the lid since it is moved less than the lid ends. The Wireless Touch Pad control can be mounted within an 80 ft. circle of the antenna as long as there are no obstructions between the antenna and the Touch Pad. Hydraulic pump units are usually mounted away from the pool. In this case you will need to use the same distance requirement from the antenna location. If the antenna cannot be mounted in line of reception you may need to move the receiver box off the hydraulic unit so the antenna is in range. Always test the reception from the proposed Touch Pad mounting location before permenantly mounting the Touch Pad! Make sure the cable is secured to the housing. RECEIVER ANTENNALID Mounting locations for Vanishing Lid mounted antenna systems Antenna mounted to bottom front of lid tray with double sided tape and fully extended toward center of mechanism. The antenna for the Wireless Touch Pad receiver is mounted on the underneath side of a lid tray. This location wi…

Text truncated - open the document above for the full version.

External Photos

COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 25 of 26 Front View Of The EUT

ID Label/Location Info

copyright Cover Pools Inc. 2000 * 66 East 3335 South Salt Lake City, UT 84115 * 801-484-2724 Fax 801-484-2763 * www.coverpools.com Rev. 1 May 02 Page 1 Wireless 916.5MHz Touch Pad w/ FCC ID Schematic

Internal Photos

COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 26 of 26 Back View Of The EUT

Test Report

TEST REPORT FROM: COMMUNICATION CERTIFICATION LABORATORY 1940 W. Alexander Street Salt Lake City, Utah 84119-2039 Type of Report: Certification TEST OF: SAVE-T Cover II FCC ID: P8G-50134 To FCC PART 15, Subpart C Section 15.231 Test Report Serial No: 73-7719 Applicant: Cover-Pools,Inc. 66 East 3335 South Salt Lake City, UT 84115 Date of Test: March 5 th & 6 th , 2002 Issue Date: March 12, 2002 COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 2 of 26 CERTIFICATION OF ENGINEERING REPORT This report has been prepared by Communication Certification Laboratory to determine compliance of the device described below with the certification requirements of FCC Part 15, Subpart C Section 15.231. This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. - Applicant: Cover-Pools, Inc. - Manufacturer: KWM Electronics Corporation - Trade Name: Cover-Pools - Model Number: SAVE-T Cover II - FCC ID: P8G-50134 On this 12 th day of March 2002, I, individually, and for Communication Certification Laboratory, certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge, and are made in good faith. Although NVLAP has recognized that the Communication Certification Laboratory EMC testing facilities are in good standing, NVLAP does not endorse the product described in this report. COMMUNICATION CERTIFICATION LABORATORY _________________________ Tested by: Kirk P. Thomas Project Engineer COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 3 of 26 TABLE OF CONTENTS SECTION 1.0 CLIENT INFORMATION..................................4 SECTION 2.0 EQUIPMENT UNDER TEST (EUT)..........................5 SECTION 3.0 TEST SPECIFICATION, METHODS & PROCEDURES............6 SECTION 5.0 SUMMARY OF TEST RESULTS............................11 SECTION 6.0 MEASUREMENTS, EXAMINATIONS AND DERIVED RESUTLS.....12 APPENDIX 2 Photographs:........................................23 COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 4 of 26 SECTION 1.0 CLIENT INFORMATION 1.1 Client Information: Company Name: Cover-Pools Inc. 66 East 3335 South Salt Lake City, UT 84115 Contact Name: Cory Brady Title: Engineer 1.2 Manufacturer: Company Name: KWM Electronics Corporation 1355 West 8040 South West Jordan, UT 84088 Contact Name: Brad Jenkins Title: Engineer COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 5 of 26 SECTION 2.0 EQUIPMENT UNDER TEST (EUT) 2.1 Identification of EUT: Trade Name: Cover-Pools Model Name or Number: SAVE-T Cover II Serial Number: N/A Options Fitted: N/A Country of Manufacture: USA 2.2 Description of EUT: The SAVE-T Cover II is a wireless pool cover system, used to open and close pool covers. The SAVE-T Cover II consists of a wireless touch pad, and a receiver unit. The Touch Pad sends a digital signal to the cover receiver unit, which is mounted in the cover housing. The SAVE-T Cover II operates at 916.5 MHz. This report covers the transmitter portion of the device only the receiver and digital circuitry is covered under a separate declaration of conformity report. COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 6 of 26 SECTION 3.0 TEST SPECIFICATION, METHODS & PROCEDURES 3.1 Test Specification: Title: FCC PART 15, Subpart C (47 CFR 15). Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz. Purpose of Test: The tests were performed to demonstrate Initial compliance. 3.2 Methods & Procedures: 3.2.1  15.231 (a) The provision of this section are restricted to periodic operation within the band 40.66-40.70 MHz and above 70 MHz. Except as Shown in paragraph (e) of this section, the intentional radiator is restricted to the transmission of a control signal such as those used with alarm systems, door openers, remote switches, etc. Radio control of toys in not permitted. Continuous transmissions, such as voice or video, and data transmissions are not permitted. The prohibition against data transmissions does not preclude the use of recognition codes. Those codes are used to identify the sensor that is activated or to identify the particular component as being part of the system. The following conditions shall be met to comply with the provisions for this periodic operation: (1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. (2) A transmitter activated automatically shall cease transmission within 5 seconds after activation. (3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmission to determine system integrity of transmitters used in security or safety applications are allowed if the periodic rate of transmission does not exceed one transmission of not more than one second duration per hour for each transmitter. (4) Intentional radiators which are employed for radio control COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 7 of 26 purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operated during the pendency of the alarm condition. (b) In addition to the provisions of  15.205, the field strength of emission from intentional radiators operated under this section shall not exceed the following: Fundamental frequency (MHz) Field strength of fundamental (microvolts/meter) Field strength of spurious emissions (microvolts/meter) 40.66 - 40.70 2,250 225 70 –130 1,250 125 130 – 174 1,250 to 3,750 ** 125 to 375 ** 174 – 260 3,750 375 260 – 470 3,750 to 12,500 ** 375 to 1,250 ** Above 470 12,500 1,250 ** Linear interpolations (1) the above field strength limits are specified at a distance of 3 meters. The ti…

Text truncated - open the document above for the full version.

Test Setup Photos

COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 23 of 26 PPENDIX 2 Photographs: A Front View Of The Radiated Test Setup COMMUNICATION CERTIFICATION LABORATORY TEST REPORT: 73-7719 FCC ID: P8G-50134 Page 24 of 26 Back View Of The Radiated Test Setup

Contact Information

Applicant

Nathan Dewyea(Product Development Supervisor)
[email protected]801-484-2724Fax: 801-484-2763

Technical Contact

Cover Pools, Inc.Cory Brady
[email protected]801-484-2724

66 East 3335 South Β· Salt Lake City, Utah Β· United States

Non-Technical Contact

Cover Pools, Inc.Cory Brady
[email protected]801-484-2724

Test Firm

Communication Certification Lab.Scott Earl
[email protected]801-972-6146Fax: 801-972-8432

Technical Specifications

#Rule PartsFrequency RangePower Output