FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ECRYSTAL CORPORATION/
  3. PBS-CRC1305

PBS-CRC1305Remote Control

ECRYSTAL CORPORATION
Remote Control - FCC ID PBS-CRC1305 - ECRYSTAL CORPORATION
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 10, 2014
Application Purpose
Original Equipment
Date of Application
Mar 10, 2014
Equipment Note
Remote Control
Frequency Range
433.92000000 - 433.92000000
Company
ECRYSTAL CORPORATION
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ECRYSTAL 1 Crystal Clear Vision for Precise Level Measurement Ecrystal CRC1305 Remote Control User Manual Address: 2063 S Atlantic Blvd #2c, Monterey Park, CA 91754 Email Address: [email protected] TEL: 0010-626-262-9317 FAX : 0010-626-262-9317 ECRYSTAL 2 Disclaimer Ecrystal makes no warranty of any kind with regard to the material contained in this manual, including, but not limited to, implied warranties or fitness for a particular purpose. Ecrystal shall not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of material ECRYSTAL 3 1. Introduction Remote control is designed for users to easily use our level meter, read data of level meter and Center host and set parameters. Remote control communicates with level meter through 433 wireless modules, featured by large communication range and good signal quality. Our commitment: stable product quality, warranty period of three years Thank you for purchasing our products. ECRYSTAL 4 2. Materials Included Please confirm package content No. Items Quantity Remark 1 Warranty card 1 2 Remote control 1 3 User instruction 1 4 Kit 1 ECRYSTAL 5 3. Technical Support We are available to assist with any questions or concerns you may have regarding the operation and use of the Remote control. Te l . : Technical Support: [email protected] Support Time: If you contact with us via e-mail, we will usually reply to you within 24 hours. ECRYSTAL 6 4. Product Specifications and Certifications 4.1 Parameters of remote control shuck Battery specification 3100mAh Li-Polymer battery (15 h of continuous service, 10 h of charging time) LCD screen 3.2-cu TFT True Color screen display (65,000 colors) 4.2 Other parameters Power Input USB 5V input Working temperature 0~55 °C Working humidity 0~55 °C Waterproofing grade Non-water-proof Drop height range 1.5m ECRYSTAL 7 5. Product structure Structure Product show No. Items No. Items 1 Company logo 5 Esc. key 2 Power switch 6 USB interface 3 Left Arrow 7 Right Arrow 4 Setting key (Enter key) 1 2 3 4 5 6 7 ECRYSTAL 8 6. How to operate the Remote control 6.1. Startup picture When users slide up the ON in the upper left corner of remote control, the remote control shows normal startup state and company logo. The picture will automatically enter Address List after startup picture lasts 2 s. 6.2. Address List 6.2.1Introduction: Address list includes the addresses of n (n<127) level meters available to users. If the content cannot be displayed in one screen, users can read all by sliding the screen up/down. 6.2.2 Select address When users click the address No. of a level meter with stylus, the address No. will be shown in black, thus the selection of level meter is completed. 6.2.3 Cancel selection ECRYSTAL 9 When users click another address, the address in black will be replaced by the address clicked. 6.2.4 Establish communication When users click the address having been selected once again, the measurement data reading interface of the level meter will be shown: it shows all measurement parameters of the level meter. When remote control fails to contact with level meter and gives it up, the remote control keeps Address List and shows Connect failed! The address with Connect failed will be shown in red. 6.2.5 Multi-screen display When users touch or press Right Arrow , the data interface of all level meters having been connected and Address List will be shown in cycle. The address No. previously connected will be shown in green background, (for example: if the level meter previously connected is No. 0001 and when users can click and Address List is re-shown, 0001 will be shown in green background). At the moment, users can click another address No. to contact with level meter. And the data reading information of the level meter will be shown. Five times of operation as such are ECRYSTAL 10 allowed. After 5 times of operation, when users try to click a new address No. and get contacted, “Connect disabled” in red will be shown in the lower left corner of screen. Under multi-screen display, when users click Left Arrow or press Left Arrow on remote control, the remote control will communicate with the level meter previously connected successfully and the data obtained in communication will appear on the screen. Multiple clicks to Left Arrow can realize cycling display of multi-level meter interface and the address Nos. of the level meters having been connected are shown in green background. On Address List, users can click Right/Left Arrow above to communicate with the level meter previously contacted successfully or communicate with a new level meter by clicking a new address No. When users click the address No. in green background, remote control will automatically communicate with the corresponding level meter, show the level meter interface, and the data obtained in communication will be shown on the screen. When users click , remote control will communicate with the level meter previously connected successfully and the data obtained in communication will be shown on the screen. Multiple clicks of can make remote control communicate in order with the level meters previously connected, and the data obtained in communication will be shown on screen. If the level meter information being shown is about the last level meter previously connected, address list will appear subsequently (the address No. previously connected successfully will be shown in green background). When users click right/left arrow above or press Right/Left Arrow in the bottom of remote control, remote control will communicate with the level meter previously connected successfully or communicate with a new level meter by clicking a new address No. ECRYSTAL 11 When users click the address No. in green background, remote control will automatically communicate with corresponding level meter, show the level meter interface, and the data obtained in communication will be shown…

Text truncated - open the document above for the full version.

Cover Letter(s)

ECRYSTAL CORPORATION Add: 1617 E Adams Blvd, Los Angeles, CA 90011, USA Phone: 626 262 9317 Fax: 626 262 9317 2014-03-03 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: PBS-CRC1305 We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics Diagram - Block Diagram - Operation description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s name / title : Rongting Guo /Assistant Manager Contact information / Address : 1617 E Adams Blvd, Los Angeles, CA 90011, USA Phone: 626 262 9317 Fax: 626 262 9317 Email: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 3 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 3 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 3 Fig.5 Fig.6

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size: L5.8cm*W3.0cm Material: Tagboard Glue: adhesive sticker Font color: Black Label color: White Label Location ECRYSTAL FCC ID: PBS-CRC1305 Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Made in China Remote Control

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 3 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 3 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 3 Fig.5 Fig.6

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.: LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 25 FCC TEST REPORT For ECRYSTAL CORPORATION Remote Control Model No.: CRC1305 Prepared for : ECRYSTAL CORPORATION Address : 1617 E Adams Blvd, Los Angeles, CA 90011, USA Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China Date of receipt of test sample : December 10, 2013 Number of tested samples : 1 Serial number : Prototype Date of Test : December 10, 2013 – March 01, 2014 Date of Report : March 01, 2014 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.: LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 25 FCC TEST REPORT FCC CFR 47 PART 15 C(15.231): 2012 Report Reference No. .............. : LCS131210272TF Date of Issue ................................ : March 01, 2014 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................ : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ........ : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ....................... : ECRYSTAL CORPORATION Address ........................................ : 1617 E Adams Blvd, Los Angeles, CA 90011, USA Test Specification Standard ....................................... : FCC CFR 47 PART 15 Subpart C: 2012, ANSI C63.4-2003 Test Report Form No. ................ : LCSEMC-1.0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................. : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Remote Control Trade Mark .................................. : ECRYSTAL Model/ Type reference ................. : CRC1305 Ratings ......................................... : DC 3.7V by battery(3100mAh) Recharge Voltage: DC 5V/1A Result ......................................... : Positive Compiled by: Supervised by: Approved by: Leo Lee/ File administrators Fox Zhang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.: LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 25 FCC--TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS131210272TF March 01, 2014 Date of issue Type / Model........................... : CRC1305 EUT......................................... : Remote Control Applicant............................... : ECRYSTAL CORPORATION Address.................................. : 1617 E Adams Blvd, Los Angeles, CA 90011, USA Telephone............................... : / Fax.......................................... : / Manufacturer........................ : SHANGHAI HUIBO AUTOMATIC GAUGE CO., LTD Address................................... : Room 1611, 19 WuNing Road, ShangHai, China Telephone............................... : / Fax.......................................... : / Factory................................... : SHANGHAI HUIBO AUTOMATIC GAUGE CO., LTD Address................................... : Room 1611, 19 WuNing Road, ShangHai, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.: LCS131210272TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 25 TABLE OF CONTENTS 1. GENERAL INFORMATION ......................................................................................................................................... 5 1.1. DESCRIPTION OF DEVICE (EUT) .................................................................................................................................. 5 1.2. OBJECTIVE ................................................................................................................................................................... 5 1.3. ENVIRONMENTAL CONDITIONS.................................................................................................................................... 5 1.4. HOST SYSTEM CONFIGURATION LIST AND DETAILS .................................................................................................... 6 1.5. EXTERNAL I/O CABLE ................................................................................................................................................. 6 1.6. DESCRIPTION OF TEST FACILITY .................................................................................................................................. 6 1.7. STATEMENT OF THE MEASUREMENT UNCERTAINTY ................................................................................................... 6 2. TEST…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement (X Position) Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-CRC1305 Report No.:LCS131210272TF _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 1.2. Photo of Line Conducted Emissions Measurement

Contact Information

Applicant

Rongting Guo(Assistant Manager)
[email protected]626 262 9317Fax: 626 262 9317

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]86-0755-82591330Fax: 86-0755-82591332

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from ECRYSTAL CORPORATION

Coal Ash Sensor Host - FCC ID PBS-CASH01 - ECRYSTAL CORPORATION
PBS-CASH01

Coal Ash Sensor Host

Jan 30, 2016

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Coal Ash Detector - FCC ID PBS-CASAAC - ECRYSTAL CORPORATION
PBS-CASAAC

Coal Ash Detector

Mar 06, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Coal Ash Detector - FCC ID PBS-ECRYSTAL128 - ECRYSTAL CORPORATION
PBS-ECRYSTAL128

Coal Ash Detector

Aug 16, 2012

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter