FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ECRYSTAL CORPORATION/
  3. PBS-ECRYSTAL128

PBS-ECRYSTAL128Coal Ash Detector

ECRYSTAL CORPORATION
Coal Ash Detector - FCC ID PBS-ECRYSTAL128 - ECRYSTAL CORPORATION
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 16, 2012
Application Purpose
Original Equipment
Date of Application
Aug 16, 2012
Equipment Note
Coal Ash Detector
Frequency Range
433.92000000 - 433.92000000
Company
ECRYSTAL CORPORATION
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 FTS series passive nuclear material location Installation and operation instruction Shanghai hui bo automation instrument Co., LTD 2012.2 2 1.Product Principle FTS series without nuclear material place plan radioactive sources themselves have no radioactive sources, with just nuclear method 1.1 The characteristics of gamma rays (Gamma rays is the nucleus of a with some energy gamma photons. Nature in the widespread can emit gamma rays of the natural and artificial of radioactive nuclides. For example, traditional nuclear material a plan of the use of radioactive sources 137 Cs, 60 Co, etc. The widespread use of cement, ceramic tile, marble, etc building materials have different strength of radioactive) (Gamma rays have very strong penetration, in through the material, strength and the density of material related to abate, accord with index rule. Main mechanism is a bundle of energy gamma rays of the γ photon and material produce photoelectric effect, Compton effect and electronic after the energy loss to effect, from the original rays in the beam disappear) Strength for I0 gamma rays through the thickness of t, density of ρ tested after things, reduced intensity for I, when I0 and t must, I and ρ related. I = I0e-t ρ k One k for quality absorption coefficient 1.2(The traditional nuclear material location principle) The traditional nuclear material place plan ignored the natural environment Widespread trace amounts of natural radioactive isotopes, use The strength of the radioactive sources) issued far outweigh the environmental gamma Rays. When the material position change, higher or lower In the probe and the source of the container installation position, detection Device detected radioactive sources of a gamma rays intensity Different. This material to judge whether installation Position. 1.3 No nuclear material location principle radioactive sources Do not need artificial sources, make use of the nature The environment in the widespread trace natural radioactive isotopes. When the material position change, material number of how many, With the detector distance change, detection To measure the materials own gamma rays are different; Because the material shield effect, when the material location Change, through the vessel gamma rays strength will also send Life changes. FTS series without nuclear material place meter is radioactive sources roots According to the probe to measure the change of gamma rays, the...... Random small signal recognition technology and special signal processing process Sequence, effectively a signal from the noise that was extracted out, to determine the position of the material 3 2. Product features 2.1 The absolute non-contact measurement With the traditional nuclear material location, non-contact measurement, good reliability Don't open hole in ontology, and even in the measuring insulation layer outside Maintenance easy to change, do not affect ontology operation (Won't be dropping material broken Don't be measured by the temperature of the material influence And tested medium not contact, and not wearing, and no probe hang material problem 2.2 No radioactive sources 2.3 Installation simple The equipment is installed in the ontology outside, even in the thermal insulation layer outside. So installation, maintenance is very convenient. And even in the ontology runtime installation. 2.4 Wireless remote debugging Fission products without probe place debugging. Debugging, use the debugger in instrument Settings parameters. Debuggers can be charged inserted The products can be integrated in the probe in commissioning, also can use remote wireless debugging, still can remote debugging. 2.5 long-life No loss components, no service life limits, no maintenance, lower cost. There is no traditional nuclear material location service life restrictions 2.6 Of container wall hanging material Measurement is the total amount of the ashes of the installation position, the vessel wall hanging ash with the real material is full after all, in total have very big difference, so can distinguish exactly is to hang a material or material place really arrived 2.7 Resistance to dust Measurement is the total amount of the ashes of the installation position, container of fly ash and the real situation of the material in total full state after all have very big difference, so can tell is fly ash, or really material is full. 2.8 Resistance to bad environment Environmental temperature:-45 °C—75 °C Protection: detector stainless steel, fully closed structure, IP66 protection grade Power supply: wide voltage input, strong adaptability. 2.9 Wide application Radioactive materials (material radioactivity level higher than the environment radioactive). Such as: coal ash and slag heap, asphalt, cement. Not radioactive materials (material radioactivity level below the environment radioactive). Such as: water. Weak radioactive materials (material radioactivity level and environmental radioactive rather). Such as: some stone, ore. Ash and water as the boundary plane (radioactive materials and without the boundary of radioactive materials face) 4 2.10 The analogue Analog output ash the percentage of the amount, or gray a height, intuitive and clear. Digital display reflects the changing process of a grey, is very helpful in the operation of the personnel remove of the status of the ash system; 2.11 selfchecking function Can real-time inspect internal high voltage power supply is normal, check the environmental temperature is overrun, check grounding are good, check the 24 V power supply provided external is normal or not (4 ~ 20 mA output of analogue products), check the probe output is normal (fission products) 3. Technology parameters 3.1 power (1) AC 120V/60Hz,50mA; 3.2 output Passive contacts: DPST contact capacity for 120 VAC, 5 A Analogue for 4 ~ 20 mA signal. RS-485 output Wireless communication output; 3.3 OLED display 128 X64 all the dot matrix, and gray OLED graphic display interface 3.4…

Text truncated - open the document above for the full version.

Cover Letter(s)

ECRYSTAL CORPORATION Add: 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Phone: 626 262 9317 Fax: 626 262 9317 2012-08-10 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: PBS-ECRYSTAL128 We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics Diagram - Block Diagram - Operation description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s name / title : Rongting Guo /Assistant Manager Contact information / Address : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Phone: 626 262 9317 Fax: 626 262 9317 Email: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 1. EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 Fig.3 Antenna

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 LABEL AND LOCATION Size: 8.0cm(L) x 4.0cm(W) Label Location ECRYSTAL CORPORATION Product Name: Coal Ash Detector Model Number: NAKe-AC-DM This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: PBS-ECRYSTAL128

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 6 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 6 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 6 Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 6 Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 5 of 6 Fig.9 Fig.10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 6 of 6 Fig.11 Fig.12

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 25 RADIO TEST REPORT For ECRYSTAL CORPORATION Coal Ash Detector Model No.: NAKe-AC-DM Prepared for : ECRYSTAL CORPORATION Address : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Date of receipt of test sample : July 10, 2012 Number of tested samples : 1 Serial number : Prototype Date of Test : July 10, 2012 – August 10, 2012 Date of Report : August 10, 2012 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 25 TEST REPORT FCC CFR 47 PART 15 C(15.231) Report Reference No. .............. : LCS120710072TF Date of Issue ................................ : August 10, 2012 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................ : 1F., Xingyuan Industrial Park, Tongda Road, Bao’an Blvd., Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure........ : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name....................... : ECRYSTAL CORPORATION Address ........................................ : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Test Specification Standard ....................................... : FCC CFR 47 PART 15 Subpart C, ANSI C63.4-2003 Test Report Form No................. : LCSEMC-1.0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Coal Ash Detector Trade Mark .................................. : ECRYSTAL Manufacturer................................ : ECRYSTAL CORPORATION Model/ Type reference................. : NAKe-AC-DM Ratings ......................................... : Input: AC 120V/60Hz, Current: 50mA Result ......................................... : Positive Compiled by: Supervised by: Approved by: Ada Liang / File administrators Vito Cao/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 25 TEST REPORT Test Result: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS120710072TF August 10, 2012 Date of issue Type / Model........................... : NAKe-AC-DM EUT......................................... : Coal Ash Detector Applicant............................... : ECRYSTAL CORPORATION Address.................................. : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ECRYSTAL CORPORATION Address................................... : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Telephone............................... : / Fax.......................................... : / Factory................................... : ECRYSTAL CORPORATION Address................................... : 2063 S Atlantic Blvd #2c, Monterey Park, CA91754 Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 25 TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................................. 5 1.1. DESCRIPTION OF DEVICE (EUT) ...........................................................................................................................5 1.2. OBJECTIVE............................................................................................................................................................ 5 1.3. ENVIRONMENTAL CONDITIONS............................................................................................................................. 5 1.4. HOST SYSTEM CONFIGURATION LIST AND DETAILS............................................................................................. 5 1.5. EUT INTERFACE PORTS........................................................................................................................................ 6 1.6. EUT OPERATION.................................................................................................................................................. 6 1.7. ANTENNA SYSTEM................................................................................................................................................ 6…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emission Measurement Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: PBS-ECRYSTAL128 Report No.: LCS120710072TF ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 1.2. Photo of Conducted Emission Measurement Fig.1

Contact Information

Applicant

Rongting Guo(Assistant Manager)
[email protected]626 262 9317Fax: 626 262 9317

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]86-0755-82591330Fax: 86-0755-82591332

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from ECRYSTAL CORPORATION

Coal Ash Sensor Host - FCC ID PBS-CASH01 - ECRYSTAL CORPORATION
PBS-CASH01

Coal Ash Sensor Host

Jan 30, 2016

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Remote Control - FCC ID PBS-CRC1305 - ECRYSTAL CORPORATION
PBS-CRC1305

Remote Control

Mar 10, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Coal Ash Detector - FCC ID PBS-CASAAC - ECRYSTAL CORPORATION
PBS-CASAAC

Coal Ash Detector

Mar 06, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter