FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Waio, Inc./
  3. PG2-TDA123GGT

PG2-TDA123GGTAudio Transmitter

Waio, Inc.
Audio Transmitter - FCC ID PG2-TDA123GGT - Waio, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 14, 2013
Application Purpose
Original Equipment
Date of Application
Mar 14, 2013
Equipment Note
Audio Transmitter
Frequency Range
88.90000000 - 107.10000000
Company
Waio, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Waio Inc : www.waio.com 888.950.9246, Email: [email protected] Page 1 FCC Compliance Statement This equipment complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the unit off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult our techs support department or an experienced radio/TV technician for help This equipment has been verified to comply with the limits for a Class B computing device, pursuant to the FCC Rules. Operation with non-approved equipment is likely to result in interference to radio and TV reception. The user is cautioned that changed and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment. Canada Compliance Statement (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. FM Transmitter Models: AXS-FMTD AXS-FMTXD CT-FMTD Waio Inc : www.waio.com 888.950.9246, Email: [email protected] Page 2 OVERVIEW OF MODES The following user modes are selected by pushing the button labeled “MODE”: 1. Frequency Mode – Allows user to select a broadcast frequency. This mode is indicated by a frequency in the display window. This mode also checks for the presence of an adequate input signal. When the device is not connected properly or the input volume is not sufficient, the left-most decimal point will be illuminated. 2. Input Level Mode – Adjusts the audio level into the Transmitter. This mode is indicated by a number 0 – 10 in the display window. SELECT A BROADCAST STATION 1. Tune your car radio or Walkman-style FM receiver to 101.5 FM then advance up or down through the channels until you hear a station that is static only. This empty frequency is available to broadcast TV audio. 2. Press the UP or DOWN button on the Transmitter until the desired frequency is displayed. 3. Note that the frequency and other mode settings will be saved into the Transmitter after the buttons have not been pressed for 2 minutes so that if a power outage is experienced the proper settings will be restored when power is restored. CONNECT TO AUDIO SOURCE 1. Connect the audio source to the transmitter through one of the 3 audio input options: A. analog audio jack (RCA or headphone jack from LCD or satellite/cable box should be chosen as a first option when available) B. digital optical jack C. digital coax jack The transmitter will automatically detect the input option 2. Adjust the LCD Volume to a mid-range or until the audio broadcast from the LCD provides the best sound quality. The LCD audio level to the Transmitter can also be adjusted by pressing the mode button to access the Input Level mode. This mode is indicated by a number 0-10 in the display window. Press the UP/DOWN buttons to adjust the input audio level until the audio broadcast provides the best sound quality. 3. Note that the left-most digit and left-most decimal point functions as a simple volume level meter. The left-most decimal point will light up when no audio is detected from the audio source. The bottom LED segment illuminated indicates lower than desired audio level. The bottom and middle level segments illuminated indicates a favorable audio setting. When all 3 audio segments are lit up, the input volume level is too high resulting in an overdriven condition. NOTE: The Transmitter incorporates an Automatic Level Control feature which will automatically fine- tune the internal audio signal level for optimum performance after the initial setting (above) has been completed.

Attestation Statements

970.532.2286 PO Box 1619 Fax: 970.532.2294 Berthoud, CO 80513 25 February 2013 Re: Electrically identical models Applicant: Waio Inc FCC ID: PG2-TDA123GGT (FM Transmitter) To whom it may concern, Please be advised that models AXS-FMTD, AXS-FMTXD, and CT-FMTD are electrically identical. Sincerely, Timothy J. DePumpo President, Waio Inc.

Cover Letter(s)

970.532.2286 PO Box 1619 Fax: 970.532.2294 Berthoud, CO 80513 Letter of Agency I appoint Intertek Testing Services NA Inc. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under the FCC rules until further notice. I further certify that no party (as defined in 1.2002 of CFR 47, 1995) to this application, including myself, is subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,853A. Equipment: AXS-FMTD, AXS-FMTXD, CT-FMTD Dated this 25 th day of February, 2013. _______ Signature ___Timothy J. DePumpo___________________ Name ____President____________________________ Title ____Waio Inc____________________________ Company ____970.532.2286_________________________ Telephone

Cover Letter(s)

970.532.2286 PO Box 1619 Fax: 970.532.2294 Berthoud, CO 80513 25 February 2013 Attention: Intertek TCB Re: Request for confidentiality Applicant: Waio Inc FCC ID: PG2-TDA123GGT (FM Transmitter) To whom it may concern, Request is hereby submitted by Waio Inc to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential:  Schematics  Detailed Block diagrams  Detailed Operational/Functional Description  Parts list Waio, Inc has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Sincerely, Timothy J. DePumpo President, Waio Inc.

External Photos

Example text shown, not actual text. Actual label text is contained in a separate exhibit

ID Label/Location Info

Waio – Placement of FCC Label FCC Labels will be located on the bottom side of th e Transmitter with-in the dashed area shown below. Waio – Placement of FCC Label

ID Label/Location Info

FM Transmitter Labels This device complies with Part 15 of theFCC Rules. Operation is subject To thefollowing two conditions: (1) This device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may causeundesired operation. www.waio.com888.950.9246 AXS-FMTD FCC ID: PG2-TDA123GGTIC ID: 7212A-0729ICJDSERIAL NO. CEI1215L01 This device complies with Part 15 of theFCC Rules. Operation is subject To thefollowing two conditions: (1) This device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may causeundesired operation. www.waio.com888.950.9246 AXS-FMTXD FCC ID: PG2-TDA123GGTIC ID: 7212A-0729ICJDSERIAL NO. CEI1215L01 This device complies with Part 15 of theFCC Rules. Operation is subject To thefollowing two conditions: (1) This device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may causeundesired operation. www.waio.com888.950.9246 CT-FMTD FCC ID: PG2-TDA123GGTIC ID: 7212A-0729ICJDSERIAL NO. CEI1215L01 Waio, Inc, 970.532.2286, [email protected]

Test Report

EMC Report for WAIO on the Model: AXSFMTD Page 1 of 72 TEST REPORT Report Number: 100860883DEN-001 Project Number: G100860883 Report Issue Date: 8/31/2012 Product Designation: Model: AXS-FMTD Standards: FCC 47CFR Part 15C RSS-210 - Issue 8: 2010 RSS-GEN - Issue 3: 2010 Tested by: Client: Intertek Testing Services NA, Inc. 1795 Dogwood St. Suite 200 Louisville, CO 80027 Waio Inc. 2450 Eliot Street, Suite 5 Denver, CO 80211 Report prepared by Report reviewed by Randy Thompson Senior EMC Project Engineer Michael Spataro Engineering Team Leader This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 100860883DEN-001 Issued:8/31/2012 EMC Report for WAIO on the Model: AXSFMTD Page 2 of 72 TABLE OF CONTENTS 1 Introduction and Conclusion .............................................................................................................. 3 2 Test Summary ...................................................................................................................................... 3 3 Description of Equipment Under Test................................................................................................ 5 4 System setup including cable interconnection details, support equipment and simplified block diagram ........................................................................................................................................................ 9 5 Radiated Unintentional & Tx Spurious Emissions.......................................................................... 11 6 200kHz Bandwidth & Band Edge ...................................................................................................... 34 7 Radiated Tx Intentional Emissions – Fundamental & Harmonics of the Fundamental............... 40 8 AC Mains Conducted Emissions ...................................................................................................... 54 9 Occupied Bandwidth (OBW) ............................................................................................................. 61 10 Product Modifications required to pass....................................................................................... 66 11 Measurement Uncertainty.............................................................................................................. 70 12 Revision History ............................................................................................................................. 71 Intertek Report Number: 100860883DEN-001 Issued:8/31/2012 EMC Report for WAIO on the Model: AXSFMTD Page 3 of 72 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Test date Result 5 Radiated Unintentional Spurious Emissions - FCC 15.239(c)/ 15.209 [Covers IC RSS-210 A2.8/ RSS-Gen 7.2.5] 08/10/2012 08/13/2012 Pass 6 200kHz Bandwidth & Band Edge – FCC 15.239(a) [Covers IC RSS-210 A2.8] 08/08/2012 Pass 7 Tx Radiated Emissions - FCC 15.239(b) [Covers IC RSS-210 A2.8] 08/07/2012 08/08/2012 Pass 8 AC Conducted Emissions - FCC 15.207 [Covers RSS-Gen 7.2.4] 08/28/2012 Pass 9 Occupied Bandwidth Measurement - RSS-Gen 4.6.1 08/17/2012 Pass General Notes: 1) The testing in this report covers the following product models: FM Radio mode of operation (88.9 MHz to 107.1 MHz). All models are electrically identical:  AXS-FMTD  AXS-FMTXD  CT-FMTD 2) Product is RSS-210 Category 1 equipment. Radio Notes: 1) FCC CFR47 Part 15.31: Measurement Standards: In any case where the device is powered off a battery, a fresh battery was used during test. In cases where the device is powered off an AC supply, voltage was varied per Part 15.31 to find worst case emissions. 2) FCC CFR47 Part 15.35: Measurement Detector Functions and Bandwidths were utilized when performing the measurements within this report. 3) Testing of the product included (3) axes (product orientations). 4) Testing of the product included (3) Tx channels (low, mid, high). 5) No Duty Cycle Correction Factor for pulsed signals was utilized in this report. Intertek Report Number: 100860883DEN-001 Issued:8/31/2012 EMC Report for WAIO on the Model: AXSFMTD Page 4 of 72 2.1 Test Facility Intertek Denver’s testing facilities are located at 1795 Dogwood St. Suite 200 Louisville, CO 80027. The testing facility is ISO17025:2005 accredited by A2LA, our lab code is 2506.02, our VCCI registration numbers are. R-1643, C-1752 and T-1558, our FCC designation no. US1121 and our IC lab no. 2042N. Te…

Text truncated - open the document above for the full version.

Test Setup Photos

1.1 Setup Photographs: Product Configuration – FM Product Option Test setup – Front view (Axis 2 – Worst Case) (Axis 1) Photo: Test setup – Rear view Photo: Antenna Setup Antenna Setup: Active Loop Antenna - 10kHz to 30MHz Antenna Setup: BiLog Antenna - 30MHz to 1000MHz Antenna Setup: Ridged Guide Horn Antenna – Above 1GHz

Contact Information

Applicant

Timothy J DePumpo(President)
[email protected]303.525.8723Fax: 303.765.0467

Technical Contact

Waio Inc.Timothy J DePumpo
[email protected]9705322285

PO Box 1669 · Berthoud, Colorado · United States

Non-Technical Contact

Waio Inc.Timothy J DePumpo
[email protected]9705322285

Test Firm

Intertek Testing Services NA, Inc.Paul Coghill
[email protected]303-405-3552Fax: 303 449 6160

Technical Specifications

#Rule PartsFrequency RangePower Output
115C88.9 MHz - 107.1 MHz-
Confidentiality
Long Term
Grant Notes
Integral Antenna

Other Applications from Waio, Inc.

Audio Transmitter - FCC ID PG2-TDA789ICJ - Waio, Inc.
PG2-TDA789ICJ

Audio Transmitter

Mar 14, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Broadcast Radio - FCC ID PG2-IBR2002 - Waio, Inc.
PG2-IBR2002

Broadcast Radio

Apr 18, 2001

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter