PHGLK001Console for Sporting Goods

Tung Keng Enterprise Co. Ltd
Console for Sporting Goods - FCC ID PHGLK001 - Tung Keng Enterprise Co. Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 27, 2014
Application Purpose
Original Equipment
Date of Application
Aug 27, 2014
Equipment Note
Console for Sporting Goods
Frequency Range
2402.00000000 - 2480.00000000
Company
Tung Keng Enterprise Co. Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

25 LK500Ui / Ri / Ei CONSOLE OPERATIONS SPECIFICATIONS: ENTER RESET To reset all parameters to default value START/STOP To start or stop training UP To make upward setting change DOWN To make downward setting change RECOVERY In stop or start mode, pressing this button will start Heart Rate recover y status measurement. Time will count down from 60 seconds QUICK START Starts the machine without any preset program or data from user FUNCTION: TIME Displaying the workout time while exer cising SPEED Displaying the current speed DISTANCE Accumulating the distance while exer cising PULSE 30-240 BPM CALORIES Counts calories while exer cising RPM Displaying crank speed in rev olution per minute 26 POWER MODE When the machine powers on, the display will light up with all numerals. After two seconds, it will enter the "user selecting" mode. If the user does not operate the machine, or the machine receives no signal after 4 minutes, the computer will enter an idol mode. GETTING STARTED - OPERATING PROCEDURE: Start pedaling and the console will turn on. Use the UP/DOWN buttons to set up your user data by selecting any user U0-U4. Press the ENTER button to accept user selection. Press UP/DOWN buttons to toggle between genders. Press ENTER to accept. Use the UP/ DOWN to set AGE then press ENTER. Use the UP/DOWN buttons to enter height in inches then presss ENTER to accept. Use the UP/DOWN buttons to input weight then press ENTER to select. See below for step by step instructions. 1. Press ENTER to confirm the USER, then enter the sex setting. The right side will displays SEX, use the UP/DOWN buttons to choose male or female. 2. Press ENTER to confirm the gender selection, then enter the AGE setting. The right side will display AGE, use the UP/DOWN buttons to select age setting. 27 3. Press ENTER to confirm the AGE setting, then enter the HEIGHT setting. The right side will display HEIGHT, use the UP/DOWN buttons to select the HEIGHT setting. 4. Press ENTER to confirm the WEIGHT setting, then enter WEIGHT setting. The right side will display WEIGHT, use the UP/DOWN buttons to select the WEIGHT value. 5. Press ENTER to confirm the HEIGHT setting, then enter the exercise program selecting page. Use the UP/DOWN buttons to select between the exercise programs below. MANUALPROGRAMFITNESS WAT TPERSONALHRC RANDOM 28 NAVIGATING THE PROGRAMS MANUAL MODE User may preset their own resistance level from 1 to 24 by pressing the UP/DOWN buttons. The default resistance level is 1. Press ENTER to confirm. Using the UP/DOWN buttons enter values for TIME, DISTANCE, CALORIES, PULSE, and then press START to begin your workout. PROGRAM MODE There are 12 preset programs. Use the UP/DOWN buttons to select the desired program profile, then press the ENTER button to confirm. Use the UP/DOWN buttons to adjust the resistance level. Press ENTER to confirm. Enter values for TIME, DISTANCE, CALORIES, PULSE, and then press START/STOP to begin your workout. FITNESS TEST Use the UP/DOWN buttons to select FITNESS and press ENTER. Press START/STOP to start the test. The user has to achieve the greatest distance possible in 8 minutes. When the time is up, the electronic device will work out the difference and your fitness rating will be displayed up on the screen. PERSONAL MODE Users may create their own profile in this mode. The first segment of the profile will start blinking. Use the UP/DOWN buttons to adjust resistance level for each segment. Once all 16 segments have been entered, press the ENTER button to confirm. Press START/STOP to begin your workout. WATT CONTROL MODE Enter values for TIME, DISTANCE, CALORIES, PULSE, and then press START/STOP to begin your workout. User may set the Watt value by pressing the UP/DOWN buttons to change in 10 Watt increments. HRC MODE Input personal data: SEX, AGE, HEIGHT and WEIGHT. User may select different target Heart Rate from 55%, 75%, 90% and TARGET by using the UP/DOWN buttons. Press ENTER to confirm. Then, enter values for TIME, DISTANCE, CALORIES, and then press START/STOP to begin your workout. 29 PRESET PROGRAMS P2P2P3 P4P5P6 P7P8P9 P10P11P12 HRC PROGRAMS (55%, 75%, 90%, TAG) HRC 55%HRC 75%HRC 90%HRC Target Heart Rate 30 TEST FUNCTIONS RECOVERY TEST Press RECOVERY key to test HRC recovery speed. When in test mode, it will detect the HRC within 10 seconds. When finished, if there is no HRC displayed, the program will exit out of the HRC recovery mode. If there is HRC displayed, the workout will enter into 60 seconds HRC recovery. Test result is shown below: VALUECONDITION F1Best F2Very good F3Good F4Normal F5Bad F6Worse FITNESS TEST Enter FITNESS program and start the test. Test time is 8 minutes. Test result is below: VALUECONDITION F1Very Good F2Good F3Fair F4Poor F5Very Poor 31 FUNCTION STATISTICS AND RANGES ITEMSCREEN SHOWNRANGESETTING RANGEPRESET VALUESAVE 1SEX MALE/ FEM yes 2AGE 10 - 100 yes 3WEIGHT(METRIC) 20 - 330(Lb) 10 - 150 (KG) yes 4HEIGHT 36 - 84(INCH) 90 – 21 0(CM) yes 5TIME0:00 - 99:590:00 - 99:00 0:00no 6DISTANCE0.0 - 99.990.0 - 99.50 0.0no 7CALORIES0 - 9990 - 990 0no 8SPEED0.0 - 99.9 0.0no 9PULSE30 - 200 bpm 0no 10WAT T0 - 999 0no 11RPM0 - 250 rpm 0no 12BRAKE RESISTANCE LEVEL L1 - L24L1no “WARNING! Heart rate monitoring systems may be inaccurate. Over exercising may result in serious injury or death. If you feel faint stop exercising immediately. 32 DOWNLOADING APPS AND PAIRING YOUR DEVICE WITH YOUR EQUIPMENT DOWNLOADING THE SOFTWARE Connect the Apple device with the App Store (iTunes) or your Android Device with Google Play, search for "Pafers", then read the APP introductions and Download the APPs with bicycle/elliptical machine functions to your device, for example Pedal Monitor or other applicable apps. Note: if you download an APP for a treadmill and pair it with an Elliptical it will not work. • The App uses bluetooth mode, so please make sure the equipment and the device you are using both have bluetooth function. • The App contains the following functions, the us…

Text truncated - open the document above for the full version.

Cover Letter(s)

TUNG KENG ENTERPRISE CO., LTD. No. 1, Lane 160, Sec. 2 Tan-Fu RD., Tan-Tzu Dist Taichung , Taiwan Tel: +886-4-25321000 Fax: +886-4-25325000 E-mail: kevin [email protected] Confidentiality Letter (Permanent) Attention: Application Examiner Re: Request for confidentiality Applicant: Tung Keng Enterprise Co.,Ltd FCC ID: PHGLK001 To whom it may concern, Request is hereby submitted by Tung Keng Enterprise Co.,Ltd to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules, disclosure of this application and all accompanying documentation will not be made defore the date of the Grant for this application. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: Tung Keng Enterprise Co.,Ltd has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Sincerely, Title: Engineer Company name: Tung Keng Enterprise Co.,Ltd Date: 2013/12/23

Cover Letter(s)

TUNG KENG ENTERPRISE CO., LTD. No. 1, Lane 160, Sec. 2 Tan-Fu RD., Tan-Tzu Dist Taichung , Taiwan Tel: +886-4-25321000 Fax: +886-4-25325000 E-mail: kevin [email protected] Lettery of Agency "I, an officer of Tung Keng Enterprise Co.,Ltd do hereby authorize Jimmy Yang, who is Engineer in Intertek Testing Services Taiwan Ltd. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 and Part 18 of the FCC Rules until further notice." I further certify that no party (as defined in §1.2002(b) of CFR 47, 1992) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,853(a). By: Kevin Jen Signature Printed Title: ENGINEER Date: 2012-12-23

External Photos

External photo of EUT

ID Label/Location Info

Label Location

ID Label/Location Info

Label Location

Internal Photos

Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT RF module & Antenna RF module Internal photo of EUT RF module

RF Exposure Info

FCC ID: PHGLK001 Report No.: TS13090128-EME Page 1 of 10 0597 Maximum Permissible Exposure (MPE) Evaluation Report Report No. : TS13090128-EME Model No. : LK500Ui/Ri/Ei Issued Date : Jan. 09, 2014 Applicant: Tung Keng Enterprise Co., Ltd No. 1, Lane 160, Sec. 2, Tan-Fu Road, Tan-Tzu Dist., Taichung, Taiwan Test Method/ Standard: FCC 1.1310 Test By: Intertek Testing Services Taiwan Ltd. No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Candy Liu / Assistant These measurements were taken by: Corn Shang / Engineer The test report was reviewed by: Name Jimmy Yang Title Engineer FCC ID: PHGLK001 Report No.: TS13090128-EME Page 2 of 10 Table of Contents Summary of Tests ..............................................................................................................3 1. General information ......................................................................................................4 1.1 Identification of the EUT ........................................................................................4 1.2 Antenna description.................................................................................................4 2. Test specifications .........................................................................................................5 2.1 Introduction .............................................................................................................5 2.2 RF Exposure Limit ..................................................................................................6 2.3 RF Exposure calculations........................................................................................8 2.4 Operation mode .......................................................................................................8 2.5 Test equipment ........................................................................................................9 2.6 Test Set-up ...............................................................................................................9 3. Test results ...................................................................................................................10 FCC ID: PHGLK001 Report No.: TS13090128-EME Page 3 of 10 Summary of Tests MPE Evaluation meet FCC OET No. 65: 1997, IEEE C95.1-2005 Test Reference Results MPE Evaluation FCC Guidelines for Human Exposure IEEE C95.1Complies FCC ID: PHGLK001 Report No.: TS13090128-EME Page 4 of 10 1. General information 1.1 Identification of the EUT Product: Console for Sporting Goods Model No.: LK500Ui/Ri/Ei FCC ID.: PHGLK001 Frequency Range: 2402MHz~2480MHz Total Hopping Channel No: 79 channels Frequency of Each Channel: 2402+1k MHz, k=0~78 Type of Modulation: GFSK Rated Power: DC 9V Power Cord: N/A Data Cable: N/A Sample Received: Sep. 27, 2013 Test Date(s): Oct. 17, 2013 Note 1: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Note 2: When determining the test conclusion, the Measurement Uncertainty of test has been considered. 1.2 Antenna description The EUT uses a permanently connected antenna. Antenna Gain : 3.07 dBi Antenna Type : Chip Antenna Connector Type : Fixed FCC ID: PHGLK001 Report No.: TS13090128-EME Page 5 of 10 2. Test specifications 2.1 Introduction The EUT operates in the 2.4 GHz ISM band. Due to the EUT (include antenna) is physical secured at location is not able to be easly moved to another location, the EUT was defined as a Fixed Device. The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The maximum output power and gain of the antenna were used to calculate the limited Power density (S) at 20 cm distance away from the product. The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 and Safety Code 6 are followed. According to 1.1307 (b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. FCC ID: PHGLK001 Report No.: TS13090128-EME Page 6 of 10 2.2 RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) and KDB 447498 D01 General RF Exposure Guidance v05r02. FCC ID: PHGLK001 Report No.: TS13090128-EME Page 7 of 10 FCC ID: PHGLK001 Report No.: TS13090128-EME Page 8 of 10 2.3 RF Exposure calculations From §FCC 1.1310 table 1, the maximum permissible RF exposure for an uncontrolled environment is 1 mW/(cm 2 ) (or 10 W/m 2 )* Power density (S) is calculated by the following formula: S = (P * G)/4πR 2 where, S = Power density (mW/cm 2 ) P = Output power to antenna (mW) R = Distance between radiating structure and observation point (cm) G = Gain of antenn…

Text truncated - open the document above for the full version.

Test Report

FCC ID: PHGLK001 Report No.: TS13090119-EME Page 1 of 34 0597 EMC TEST REPORT Report No.: TS13090119-EME Model No.: LK500Ui/Ri/Ei Issued Date: Jan. 09, 2014 Applicant: Tung Keng Enterprise Co., Ltd No. 1, Lane 160, Sec. 2, Tan-Fu Road, Tan-Tzu Dist., Taichung, Taiwan Test Method/ Standard: FCC Part 15 Subpart C Section §15.205, §15.207, §15.209, §15.247, DA 00-705 and ANSI C63.4:2003 Registration No.: 93910 Test By: Intertek Testing Services Taiwan Ltd. No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Candy Liu / Assistant These measurements were taken by: Arthur Tsai / Senior Engineer The test report was reviewed by: Name Jimmy Yang Title Engineer FCC ID: PHGLK001 Report No.: TS13090119-EME Page 2 of 34 Table of Contents Summary of Tests ..............................................................................................................4 1. General Information ......................................................................................................5 1.1 Identification of the EUT ........................................................................................5 1.2 Antenna Description ................................................................................................5 2. Test Specifications.........................................................................................................6 2.1 Test Standard ...........................................................................................................6 2.2 Operation Mode.......................................................................................................6 2.3 Peripherals equipment .............................................................................................6 2.4 Measurement Uncertainty .......................................................................................6 2.5 Test Equipment........................................................................................................7 3. 20dB Bandwidth Test ....................................................................................................8 3.1 Operating Environment ...........................................................................................8 3.2 Test Setup & Procedure ...........................................................................................8 3.3 Measured Data of Modulated Bandwidth Test Results ...........................................8 4. Carrier Frequency Separation Test ..............................................................................11 4.1 Operating Environment .........................................................................................11 4.2 Test Setup & Procedure .........................................................................................11 4.3 Measured Data of Carrier Frequency Separation Test Results..............................11 5. Number of Hopping Frequencies Test.........................................................................14 5.1 Operating Environment .........................................................................................14 5.2 Test Setup & Procedure .........................................................................................14 5.3 Measured Data of Number of Hopping Frequencies Test Results ........................14 6. Time of Occupancy (Dwell Time)...............................................................................15 6.1 Operating Environment .........................................................................................15 6.2 Test Setup & Procedure .........................................................................................15 6.3 Measured Data of Maximum Output Power Test Results .....................................15 7. Maximum Output Power Test .....................................................................................20 7.1 Operating Environment .........................................................................................20 7.2 Test Setup & Procedure .........................................................................................20 7.3 Measured Data of Maximum Output Power Test Results .....................................20 8. RF Antenna Conducted Spurious Test.........................................................................21 8.1 Operating Environment .........................................................................................21 8.2 Test Setup & Procedure .........................................................................................21 8.3 Measured Data of the Highest RF Antenna Conducted Spurious Test Results.....22 9. Radiated Emission Test ...............................................................................................26 9.1 Operating Environment .........................................................................................26 9.2 Test Setup & Procedure .........................................................................................26 9.3 Emission Limits.....................................................................................................28 9.4 Radiated Spurious Emission Test Data .................................................................29 9.4.1Measurement results: frequency range from 9 kHz to 30MHz ...........................29 FCC ID: PHGLK001 Report No.: TS13090119-EME Page 3 of 34 9.4.2 Measurement Results: Frequencies Equal to or Less than 1 GHz .....................29 9.4.3 Measurement Results: Frequency above 1GHz .................................................30 10. Emission on the Band Edge §FCC 15.247(d) .........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test set-up photo

Test Setup Photos

Radiated Emission Test set-up photo Radiated Emission Test set-up photo Radiated Emission Test set-up photo

Contact Information

Applicant

Kevin Jen(Engineer)
[email protected]+886-4-2532-1000Fax: +886-4-2534-8929

Test Firm

Intertek Testing Services Taiwan Ltd.Lily Shih
[email protected]886-2-6602-2750Fax: 886-2-6602-2889

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz200.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC accepted multi-transmitter procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Tung Keng Enterprise Co. Ltd

Console for Sporting Goods - FCC ID PHGLK002 - Tung Keng Enterprise Co. Ltd
PHGLK002

Console for Sporting Goods

Aug 28, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Console for Sporting Goods - FCC ID PHGLK003 - Tung Keng Enterprise Co. Ltd
PHGLK003

Console for Sporting Goods

Aug 27, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless upper controller - FCC ID PHGDBREVO-WUC - Tung Keng Enterprise Co. Ltd
PHGDBREVO-WUC

Wireless upper controller

Oct 25, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless lower controller - FCC ID PHGDBREVO-WLC - Tung Keng Enterprise Co. Ltd
PHGDBREVO-WLC

Wireless lower controller

Oct 24, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter