Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
20 LK700Ti CONSOLE OPERATIONS 21 ABOUT THE MUSCLE DISPLAY When the USER changes the incline level it will display on the screen. Level 0 Levels 7-9 Levels 1-3 Levels 10-12 Levels 4-6 Levels 13-15 Time HRC & Age Heart Rate Training Program Array Calories Muscle Display Incline Level Speed Weight/Distance iDevice Connection Status Alpha-Numeric Display 22 START - ENTER YOUR WEIGHT When the machine first starts, all numerals will light up and then it will ask you to enter your weight. Set the weight, so that the each exercise program can calculate accurately how many calories have been lost during any given workout. 1. Press SPEED+ or SPEED- to set your weight and then press ENTER to input. 2. Screen will display SELECT PROGRAM. 3. Press SPEED+ or SPEED- to select a program or press QUICK START to begin a manual workout immediately. QUICK START 1. Press SPEED+ or SPEED- to set your weight and then press ENTER to input. 2. Press SPEED+ or SPEED- to select a program or press QUICK START to begin a manual workout immediately. 3. If you select QUICK START, the screen will display READY GO and the workout will start after a 3 seconds countdown. The workout program will start at a speed of 0.8KPH (0.5MPH) and the an incline of 0. 4. Press an Instant Incline button or INCLINE+ or INCLINE- to adjust the incline level 5. Press an Instant Speed button or SPEED+ or SPEED- to adjust the speed value. STOP OR PAUSE DURING TRAINING 1. During the workout, press STOP to pause the program. The speed of the belt will slow to zero but the incline will stay the same. 2. When the workout time has reached 99:59 or you have finished the goal of a specific 23 program, the belt will slow to zero, and the screen will display RUN END. Press STOP for 4 seconds and the systems will go back to standby mode. HOW TO SELECT A PROGRAM & PROGRAM SETUP • Press SPEED+ or SPEED- to set your weight and then press ENTER to input. • Press Mode or SPEED+/SPEED- to toggle through the programs, press ENTER to select. • List: MANUAL-P1-P2-P3-P4-P5-P6-RANDOM-USER-H.R.C.1-3-BODY FAT • Pressing STOP while in any of the programs and it will bring you back to the program selection list. • Bellow is the list of the programs and how to set up each one. MANUAL 1. Find MANUAL and press ENTER to select. 2. Press SPEED+ or SPEED- to setup target time and then press ENTER to input. 3. Press SPEED+ or SPEED- to setup target distanc and then press ENTER to input. 4. Press SPEED+ or SPEED- to setup target calories and then press ENTER to input. 5. When you have finished your set up, press START to begin the workout P1 (9 HOLE) 1. Find P1 and press ENTER to select. 2. Press SPEED+ or SPEED- to setup level and then press ENTER to input. 3. Press SPEED+ or SPEED- to setup your goal distance and then press ENTER to input. 4. The screen will display READY GO and the workout will start after a 3 seconds countdown. P2 (HILL CLIMB) 1. Find P2 and press ENTER to select. 2. Press SPEED+ or SPEED- to setup the level and then press ENTER to input. 3. Press SPEED+ or SPEED- to setup target time and then press ENTER to input. 24 4. The screen will display READY GO and the workout will start after a 3 seconds countdown. PROGRAMS P3-P6 are set up the same way as P2. RANDOM (Random Speed) 1. Find RANDOM and press ENTER to select. 2. Press SPEED+ or SPEED- to select your target time and then press ENTER to input. 3. Press SPEED+ or SPEED- to select target distance and then press ENTER to input. 4. Press SPEED+ or SPEED- to select target calories and then press ENTER to input. 4. When you have finished your setup, press START to enter begin your workout. USER (USER CAN EDIT SPEED & INCLINE PROFILE) 1. Find USER and press ENTER to select. 2. Press SPEED+ or SPEED- to choose U1, U2, U3, or U4 and then press ENTER to select. 3. Press ENTER for 3 seconds to enter into Segment Edit Mode. Press SPEED+ or SPEED- to adjust Speed and press INCLINE+ or INCLINE- to adjust incline and then press ENTER to input and go on to the next segment (there are 20 in total). When you are done with all segments, press ENTER for 3 seconds to save your custom values. 4. Press ENTER to select U1. 5. Press SPEED+ or SPEED- to set time and then press ENTER to input. 6. Press SPEED+ or SPEED- to set distance and then press ENTER to input. 7. Press SPEED+ or SPEED- to set calorie and then press ENTER to input. 8. When you are done press START to begin the workout. H.R.C: 60%/75%/THR 1. There are three HRC programs, find and choose between 60%, 75%, or THR (Target Heart Rate) and then press ENTER to select. Note: In the HRC Program, the computer will only accept the “Wireless Heart Rate Signal” (we suggest using a wireless heart belt). If no pulse signal is detected for 45 seconds, the computer will stop and display NO PULSE. 60%, 75% 1. Press ENTER to select 60% (or 75%) 2. Press SPEED+ or SPEED- to set time and then press ENTER to input. 25 3. Press SPEED+ or SPEED- to set age and then press ENTER to input. 4. Press SPEED+ or SPEED- to set target heart rate and then press ENTER to input. 5. The screen will display READY GO and the workout will start after a 3 seconds countdown. THR (Target Heart Rate) 1. Press SPEED+ or SPEED- to set target time and then press ENTER to input. 2. Press SPEED+ or SPEED- to set target heart rate and then press ENTER to input. 3. The screen will display READY GO and the workout will start after a 3 seconds countdown. BODY FAT MODE Press ENTER to select BODY FAT and the treadmill will ask for the following information: 1. AGE: the default value is 30, and the range 13~80. Press SPEED+ or SPEED- to adjust and the press ENTER to input. 2. HEIGHT: the default value is 170 cm, and the range is 120~200 cm. Press SPEED+ or SPEED- to adjust and the press ENTER to input. 3. SEX (Gender) - press SPEED+ or SPEED- to toggle between male (1) or female (0) and the press ENTER to input. 4. Weight: the default value is 70 kg (150LB) and the range is 23~130kg (50~425LB). Press SPEED+ o…
Text truncated - open the document above for the full version.
TUNG KENG ENTERPRISE CO., LTD. No. 1, Lane 160, Sec. 2 Tan-Fu RD., Tan-Tzu Dist Taichung , Taiwan Tel: +886-4-25321000 Fax: +886-4-25325000 E-mail: kevin [email protected] Confidentiality Letter (Permanent) Attention: Application Examiner Re: Request for confidentiality Applicant: Tung Keng Enterprise Co.,Ltd FCC ID: PHGLK002 To whom it may concern, Request is hereby submitted by Tung Keng Enterprise Co.,Ltd to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules, disclosure of this application and all accompanying documentation will not be made defore the date of the Grant for this application. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description Rationale for request for confidentiality: Tung Keng Enterprise Co.,Ltd has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Sincerely, Title: Engineer Company name: Tung Keng Enterprise Co.,Ltd Date: 2013/12/23
TUNG KENG ENTERPRISE CO., LTD. No. 1, Lane 160, Sec. 2 Tan-Fu RD., Tan-Tzu Dist Taichung , Taiwan Tel: +886-4-25321000 Fax: +886-4-25325000 E-mail: kevin [email protected] Lettery of Agency "I, an officer of Tung Keng Enterprise Co.,Ltd do hereby authorize Jimmy Yang, who is Engineer in Intertek Testing Services Taiwan Ltd. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under Part 15 and Part 18 of the FCC Rules until further notice." I further certify that no party (as defined in §1.2002(b) of CFR 47, 1992) to this application, including myself, is subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,853(a). By: Kevin Jen Signature Printed Title: ENGINEER Date: 2012-12-23
External photo of EUT
Label Location
Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT Internal photo of EUT RF module Internal photo of EUT Antenna
FCC ID: PHGLK002 Report No.: TS13120073-EME Page 1 of 10 0597 Maximum Permissible Exposure (MPE) Evaluation Report Report No. : TS13120073-EME Model No. : LK700Ti Issued Date : Jan. 07, 2014 Applicant: Tung Keng Enterprise Co., Ltd No. 1, Lane 160, Sec. 2, Tan-Fu Road, Tan-Tzu Dist., Taichung, Taiwan Test Method/ Standard: FCC 1.1310 Test By: Intertek Testing Services Taiwan Ltd. No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Candy Liu / Assistant These measurements were taken by: Corn Shang / Engineer The test report was reviewed by: Name Jimmy Yang Title Engineer FCC ID: PHGLK002 Report No.: TS13120073-EME Page 2 of 10 Table of Contents Summary of Tests ..............................................................................................................3 1. General information ......................................................................................................4 1.1 Identification of the EUT ........................................................................................4 1.2 Antenna description.................................................................................................4 2. Test specifications .........................................................................................................5 2.1 Introduction .............................................................................................................5 2.2 RF Exposure Limit ..................................................................................................6 2.3 RF Exposure calculations........................................................................................8 2.4 Operation mode .......................................................................................................8 2.5 Test equipment ........................................................................................................9 2.6 Test Set-up ...............................................................................................................9 3. Test results ...................................................................................................................10 FCC ID: PHGLK002 Report No.: TS13120073-EME Page 3 of 10 Summary of Tests MPE Evaluation meet FCC OET No. 65: 1997, IEEE C95.1-2005 Test Reference Results MPE Evaluation FCC Guidelines for Human Exposure IEEE C95.1Complies FCC ID: PHGLK002 Report No.: TS13120073-EME Page 4 of 10 1. General information 1.1 Identification of the EUT Product: Console For Sporting Goods Model No.: LK700Ti FCC ID: PHGLK002 Frequency Range: 2402MHz~2480MHz Total Hopping Channel No: 79 channels Frequency of Each Channel: 2402+1k MHz, k=0~78 Type of Modulation: GFSK Rated Power: 120 Vac Power Cord: N/A Data Cable: N/A Sample Received: Sep. 27, 2013 Test Date(s): Nov. 01, 2013 Note 1: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Note 2: When determining the test conclusion, the Measurement Uncertainty of test has been considered. 1.2 Antenna description The EUT uses a permanently connected antenna. Antenna Gain : 3.07 dBi Antenna Type : Chip Antenna Connector Type : Fixed FCC ID: PHGLK002 Report No.: TS13120073-EME Page 5 of 10 2. Test specifications 2.1 Introduction The EUT operates in the 2.4 GHz ISM band. Due to the EUT (include antenna) is physical secured at location is not able to be easly moved to another location, the EUT was defined as a Fixed Device. The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The maximum output power and gain of the antenna were used to calculate the limited Power density (S) at 20 cm distance away from the product. The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 and Safety Code 6 are followed. According to 1.1307 (b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. FCC ID: PHGLK002 Report No.: TS13120073-EME Page 6 of 10 2.2 RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in 1.1307(b) and KDB 447498 D01 General RF Exposure Guidance v05r02. FCC ID: PHGLK002 Report No.: TS13120073-EME Page 7 of 10 FCC ID: PHGLK002 Report No.: TS13120073-EME Page 8 of 10 2.3 RF Exposure calculations From §FCC 1.1310 table 1, the maximum permissible RF exposure for an uncontrolled environment is 1 mW/(cm 2 ) (or 10 W/m 2 )* Power density (S) is calculated by the following formula: S = (P * G)/4πR 2 where, S = Power density (mW/cm 2 ) P = Output power to antenna (mW) R = Distance between radiating structure and observation point (cm) G = Gain of antenna in numeri…
Text truncated - open the document above for the full version.
FCC ID: PHGLK002 Report No.: TS13120072-EME Page 1 of 35 0597 EMC TEST REPORT Report No.: TS13120072-EME Model No.: LK700Ti Issued Date: Jan. 06, 2014 Applicant: Tung Keng Enterprise Co., Ltd No. 1, Lane 160, Sec. 2, Tan-Fu Road, Tan-Tzu Dist., Taichung, Taiwan Test Method/ Standard: FCC Part 15 Subpart C Section §15.205, §15.207, §15.209, §15.247, DA 00-705 and ANSI C63.4:2003 Registration No.: 93910 Test By: Intertek Testing Services Taiwan Ltd. No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Candy Liu / Assistant These measurements were taken by: Corn Shang / Engineer The test report was reviewed by: Name Jimmy Yang Title Senior Engineer FCC ID: PHGLK002 Report No.: TS13120072-EME Page 2 of 35 Table of Contents Summary of Tests ..............................................................................................................4 1. General Information ......................................................................................................5 1.1 Identification of the EUT ........................................................................................5 1.2 Antenna description.................................................................................................5 2. Test Specifications.........................................................................................................6 2.1 Test Standard ...........................................................................................................6 2.2 Operation Mode.......................................................................................................6 2.3 Measurement Uncertainty .......................................................................................6 2.4 Test Equipment........................................................................................................7 3. 20dB Bandwidth Test ....................................................................................................8 3.1 Operating Environment ...........................................................................................8 3.2 Test Setup & Procedure ...........................................................................................8 3.3 Measured Data of Modulated Bandwidth Test Results ...........................................8 4. Carrier Frequency Separation Test ..............................................................................11 4.1 Operating Environment .........................................................................................11 4.2 Test Setup & Procedure .........................................................................................11 4.3 Measured Data of Carrier Frequency Separation Test Results..............................11 5. Number of Hopping Frequencies Test.........................................................................14 5.1 Operating Environment .........................................................................................14 5.2 Test Setup & Procedure .........................................................................................14 5.3 Measured Data of Number of Hopping Frequencies Test Results ........................14 6. Time of Occupancy (Dwell Time)...............................................................................15 6.1 Operating Environment .........................................................................................15 6.2 Test Setup & Procedure .........................................................................................15 6.3 Measured Data of Maximum Output Power Test Results .....................................16 7. Maximum Output Power Test .....................................................................................20 7.1 Operating Environment .........................................................................................20 7.2 Test Setup & Procedure .........................................................................................20 7.3 Measured Data of Maximum Output Power Test Results .....................................20 8. RF Antenna Conducted Spurious Test.........................................................................21 8.1 Operating Environment .........................................................................................21 8.2 Test Setup & Procedure .........................................................................................21 8.3 Measured Data of the Highest RF Antenna Conducted Spurious Test Results.....22 9. Radiated Emission Test ...............................................................................................26 9.1 Operating Environment .........................................................................................26 9.2 Test Setup & Procedure .........................................................................................26 9.3 Emission Limits.....................................................................................................28 9.4 Radiated Spurious Emission Test Data .................................................................29 9.4.1Measurement results: frequency range from 9kHz to 30MHz ............................29 9.4.2 Measurement Results: Frequencies Equal to or Less than 1 GHz .....................29 FCC ID: PHGLK002 Report No.: TS13120072-EME Page 3 of 35 9.4.3 Measurement Results: Frequency above 1GHz .................................................30 10. Emission on the Band Edge §FCC 15.247(d) ...........................................................31 10.1 Operating Environment ................................................................................…
Text truncated - open the document above for the full version.
Conducted Emission Test set-up photo
Radiated Emission Test set-up photo Radiated Emission Test set-up photo Radiated Emission Test set-up photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 100.00 µW |

Console for Sporting Goods
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Console for Sporting Goods
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless upper controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless lower controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter