Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 . Check to see if the batteries in the mouse are installed correctly. Make sure the polarity of the batteries corresponds with the polarity signs in the battery compartment. 2 . Replace the batteries to make sure the batteries are not low on power. Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. CAUTION! The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. P/N: 266-80260-2008 Quick Start Guide Of 2.4GHz Wireless Super Mini Mouse 4 Installation 1. Plug the Nano receiver into a USB port of your computer. 2. Push the Battery Cover Switch aside, open the battery door and install battery, then close the battery cover. Receiver storage and ON/OFF the mouse 1. You can store or take out the Nano receiver from the Nano receiver storage by push/pull the Nano receiver. 2. You can switch On or shut off the mouse by use the ON/OFF switch on the bottom of the mouse. Mouse Functions Speed Control Press the CPI button and you can toggle the CPI between 800 CPI and 1600 CPI. Trouble Shooting 1. Check Nano receiver connection; try to insert Nano Receiver to another USB port on your computer. 2 3 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices).
RF_160, Issue 02 Declaration of Authorization We Company name: ShenZhen Rapoo Technology Co., Ltd Address: Block A1,B1,B2,1st second stage, 1st Industrial Park, 3rd Industrial Zone, Fenghuang Fuyong, BaoAn City: Shenzhen Country: China Declare that: Name: Neutron Engineering, Inc. Ms. Cathy Wang Address: No.3 Jinshagang 1 st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification, completing and signing of the RF-731 form and apply for confidentiality request for the following products: Product description: WIRELESS LASER NOTEBOOK MOUSE Type designation: M6126G; M6134G; M6139G; M6147G; M605SG; M606DG Trademark: MLK; RAPOO on our behalf. Date: 2010-8-27 City: Shenzhen Name: Charles Zou Title: R&D Manager Signature:
FCC, Request for non-disclosure Date: 10-Aug-09 RF_501, Issue 5 Page 1 of 1 Company Name: ShenZhen Rapoo Technology Co., Ltd Address : Block A1,B1,B2,1st second stage, 1st Industrial Park, 3rd Industrial Zone, Fenghuang Fuyong, BaoAn City: Shenzhen Country: China To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: PP2M6126GII IIII II Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: 2010-06-07 Name and signature of applicant: Charles Zou Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M6126G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M6126G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M606DG 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M606DG 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M6134G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M6134G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M6139G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 7 M6139G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M6147G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M6147G 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M605SG 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 2 of 6 M605SG 1005C149 1005C149
Neutron Engineering Inc. Project No.: 1005C149 Page 3 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 3 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 4 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 4 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 5 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 5 of 6 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 6 of 6 1005C149 1005C149 1005C149 1005C149 Neutron Engineering Inc. Project No.: 1005C149 Page 6 of 6 1005C149 1005C149 1005C149 1005C149
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 2 of 46 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 3 of 46 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 16 4.2.1 RADIATED EMISSION LIMITS 16 4.2.2 MEASUREMENT INSTRUMENTS LIST 17 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 21 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHz) 22 4.2.8 TEST RESULTS (ABOVE 1000 MHz) 24 5 . BANDWIDTH TEST 36 5.1 MEASUREMENT INSTRUMENTS LIST 36 5.2 TEST PROCEDURE 36 5.3 DEVIATION FROM STANDARD 36 5.4 TEST SETUP 36 5.5 EUT OPERATION CONDITIONS 36 5.6 TEST RESULTS 37 6 . ANTENNA CONDUCTED SPURIOUS EMISSION 39 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 4 of 46 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 39 6.1.1 MEASUREMENT INSTRUMENTS LIST 39 6.1.2 TEST PROCEDURE 39 6.1.3 DEVIATION FROM STANDARD 39 6.1.4 TEST SETUP 39 6.1.5 EUT OPERATION CONDITIONS 40 6.1.6 TEST RESULTS 41 7 . EUT TEST PHOTO 46 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 5 of 46 1. CERTIFICATION E q u i p m e n t : WIRELESS LASER NOTEBOOK MOUSE Brand Name : MLK; RAPOO Model Name : M6126G; M6134G; M6139G; M6147G; M605SG; M606DG A p p l i c a n t : ShenZhen Rapoo Technology Co., Ltd Date of Test : May. 24, 2010 ~ Jun. 03, 2010 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.249)/ ANSI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1005C149) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 6 of 46 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.249) Standard Section Test Item Judgment Remark 15.207 Conducted Emission - Note(1) 15.209 Radiated Emission PASS 15.249 Radiated Spurious Emission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) The EUT used new battery. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 7 of 46 2.1 TEST FACILITY The test facilities used to collect the test data in this report is CB03 at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792 Neutron's test firm number is 319330 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE DG-C03 CISPR 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE 30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 CB03 CISPR 200MHz ~ 1,000MHz H 2.66 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 8 of 46 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment WIRELESS LASER NOTEBOOK MOUSE Brand Name MLK; RAPOO Model Name. M6126G; M6134G; M6139G; M6147G; M605SG; M606DG OEM Brand/Model Name N/A Model Difference Only different is appearance, PCB circuit diagram is identical. The models are technically identical, only differ in exclosure for marketing purpose. Product Description The EUT is a WIRELESS LASER NOTEBOOK MOUSE. Product Type Low Power Communication Device Operation Frequency: 2402~2480 MHz Modulation Type: GFSK Number Of Channel 16C…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 43 of 43 7. EUT TEST PHOTO Radiated Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1005C149 Page 43 of 43 7. EUT TEST PHOTO Radiated Measurement Photos
No.3,Jinshagang 1st Rd, ShiXia,Dalang · Dongguan City · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |
Dongle
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterMulti-mode Wireless Mouse
Equipment Class
DTS - Digital Transmission SystemWireless optical Mouse
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterMulti-mode Wireless Keyboard
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterMulti-mode Wireless Keyboard
Equipment Class
DTS - Digital Transmission System