Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Overall View Cable Top View Side View Bottom View
Label Label Location
Cover Removed Internal View PCB Top PCB Bottom
Theory Of Operation Trafcon TX3 Transmitter The TX3 transmitter uses a frequency-modulated crystal-locked PLL and operates between 2.2 and 10VDC at a current of 10 mA nominal. At 3V it delivers (nominally) 0dBm (1mW) RF output. The data to be transmitted flows through a 27 kHz low pass filter into the modulation circuit which, in turn, drives the PLL circuit. A buffer supplies final output amplification which flows into a bandpass filter to the antenna circuit.
Document 6679-01, Rev. 0 FCC Certification Test Report Washington Laboratories, Ltd August 2001 FCC Certification Test Report for Trafcon Industries, Inc. PTB50069 August 29, 2001 Prepared for: Trafcon Industries, Inc. 81 Texaco Road Mechanicsburg, PA 17050-2623 Prepared By: Washington Laboratories, Ltd. 7560 Lindbergh Drive Gaithersburg, Maryland 20879 FCC Certification Test Report Document 6679-01, Rev. 0 FCC Certification Test Report Washington Laboratories, Ltd August 2001 FCC Certification Test Program FCC Certification Test Report for the Trafcon Industries, Inc. TX3 Transmitter PTB50069 August 24, 2001 WLL JOB# 6679 Prepared by: Brian J. Dettling Documentation Specialist Reviewed by: Michael Violette President Document 6679-01, Rev. 0 FCC ID: PTB50069 FCC Certification Test Report Washington Laboratories, Ltd August 2001 ii Abstract This report has been prepared on behalf of Trafcon Industries, Inc. to support the attached Application for Equipment Authorization. The test report and application are submitted for a Periodic Intentional Radiator under Part 15.249 of the FCC Rules and Regulations. This Federal Communication Commission (FCC) Certification Test Report documents the test configuration and test results for a Trafcon Industries, Inc. TX3 Transmitter. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. Washington Laboratories, Ltd. has been accepted by the FCC and approved by NIST NVLAP (NVLAP Lab Code: 200066-0) as an independent FCC test laboratory. The Trafcon Industries, Inc. TX3 Transmitter complies with the limits for a Periodic Intentional Radiator device under Part 15.249 of the FCC Rules and Regulations. Document 6679-01, Rev. 0 FCC ID: PTB50069 FCC Certification Test Report Washington Laboratories, Ltd August 2001 iii Table of Contents Abstract......................................................................................................ii 1 Introduction...................................................................................................................1 1.1 Compliance Statement............................................................................................1 1.2 Test Scope............................................................................................................1 1.3 Contract Information..............................................................................................1 1.4 Test Dates.............................................................................................................1 1.5 Test and Support Personnel....................................................................................1 1.6 Abbreviations.........................................................................................................1 2 Equipment Under Test....................................................................................................2 2.1 EUT Identification & Description............................................................................2 2.2 Test Configuration..................................................................................................3 2.3 Testing Algorithm...................................................................................................3 2.4 Test Location.........................................................................................................3 2.5 Measurements........................................................................................................3 2.5.1 References.........................................................................................................3 2.6 Measurement Uncertainty.......................................................................................3 3 Test Equipment..............................................................................................................4 4 Test Results...................................................................................................................4 4.1 Occupied Bandwidth..............................................................................................4 4.2 Radiated Spurious Emissions..................................................................................6 4.2.1 Test Procedure................................................................................................6 List of Tables Table 1. Device Summary....................................................................................................2 Table 2: Test Equipment List................................................................................................4 Table 3. Occupied Bandwidth Results..................................................................................6 Table 4. Radiated Spurious Emissions Limits.........................................................................6 Table 5: Radiated Emission Test Data...................................................................................7 List of Figures Figure 1. Occupied Bandwidth.............................................................................................5 Document 6679-01, Rev. 0 FCC ID: PTB50069 FCC Certification Test Report Washington Laboratories, Ltd August 2001 iv Document 6679-01, Rev. 0 FCC ID: PTB50069 FCC Certification Test Report Washington Laboratories, Ltd August 2001 Page 1 of 7 1 Introduction 1.1 Compliance Statement The Trafcon Industries, Inc. TX3 Transmitter complies with the limits for an Intentional Radiator device under Part 15.249 of the FCC Rules and Regulations. 1.2 Test Scope Tests for radiated emissions were performed. All measurements were performed according to the 1992 version of ANSI C63.4. The measurement equipment conforms to ANSI C63.2 Specifications for Electromagnetic Noโฆ
Text truncated - open the document above for the full version.
Radiated Emissions Test Setup
7560 Lindbergh Drive ยท Gaithersburg, Maryland ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 914.53 MHz - 914.53 MHz | 1.00 mW |

Traffic Safety Light Control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter