Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 5 User Manual Document Technical Specification version: v1.00 status: date: 2014-11-06 project title: PUR-SCANIT-350U HILTI – User Manual org 20141106_EN_UM - PUR-SCANIT- 350U Hilti_v1.00.docx created by: Stefan Detter page: 1 von 5 RF-Embedded GmbH • Kufsteiner Straße 11 • D-83080 Oberaudorf • [email protected] www.rf-embedded.eu PUR-SCANIT-350U HILTI USER MANUAL Document Technical Specification version: v1.00 status: date: 2014-11-06 project title: PUR-SCANIT-350U HILTI – User Manual org 20141106_EN_UM - PUR-SCANIT- 350U Hilti_v1.00.docx created by: Stefan Detter page: 2 von 5 RF-Embedded GmbH • Kufsteiner Straße 11 • D-83080 Oberaudorf • [email protected] www.rf-embedded.eu 1 Plug-In To start working with the PUR-DTR-100U, plug the USB connector into a free USB port of your computer. The PC will then ask you for a valid driver. 2 Driver The driver can be found in the installation package of any software from RF-Embedded. The driver for the USB device is always stored in the directory of the installation directory of the Software. E.g. C:\Program Files\RF-Embedded\Reader Suite 1.61\driver The driver can also be found on the Download Server in the directory Software\Driver. If more information for other operating systems is required, please refer to the manual “USB Reader – Installing Driver”. 3 Software There are multiple software packages for this reader. The following list shows their purpose: - Reader Suite: Discover the full functionality of the reader. The range of functions is from simple functions like reading tags up to engineering tests to analyze the reader and/or tag. - SmartReaderApp: Easy to use application to just read the tag id and import it to any other application via keyboard input. - C#/Qt-SDK: Open Source SDK and test driver to control the reader. Document Technical Specification version: v1.00 status: date: 2014-11-06 project title: PUR-SCANIT-350U HILTI – User Manual org 20141106_EN_UM - PUR-SCANIT- 350U Hilti_v1.00.docx created by: Stefan Detter page: 3 von 5 RF-Embedded GmbH • Kufsteiner Straße 11 • D-83080 Oberaudorf • [email protected] www.rf-embedded.eu 4 Scanning a tag The first step to work with the Reader Suite is to add a reader. So first connect the reader you want to use and then you can either select Menu -> Reader -> Add in the menu bar, or you right click into the white space in the main window and select “Add reader”. After this, a dialog appears where you can specify how the reader can be connected. You can find the reader in the “Serial” tab. Here you can select one of the shown reader or explicitly enter the COM port number. Initially the list shows only serial ports that are connected via USB and have the RF-Embedded VID and PID. If you activate the “Show all Serial Devices” check box, all available ports will be shown. If you have either double clicked an entry in the lists or you entered an address and pressed OK, the Reader Suite will try to connect to the reader. If this was successfully, the reader will appear in the main widget of the Reader Suite: Now you can start an inventory with the just added reader using the “Start Scan” button at the bottom left of the application. If a tag is detected, it is shown in the tree view below the reader: For more information please refer to the manual of the Reader Suite, that can either be found on the Download Server or in the Reader Suite menu at Menu -> ? -> User Manual. Document Technical Specification version: v1.00 status: date: 2014-11-06 project title: PUR-SCANIT-350U HILTI – User Manual org 20141106_EN_UM - PUR-SCANIT- 350U Hilti_v1.00.docx created by: Stefan Detter page: 4 von 5 RF-Embedded GmbH • Kufsteiner Straße 11 • D-83080 Oberaudorf • [email protected] www.rf-embedded.eu 5 Reader Specific The reader specific features are the four LEDs. The LED state can easily be controlled with the Reader Suite. The control interface can be found in the Reader settings in the tab GPIO. Through changing the Level checkbox of the specific GPIO pin, the state of the LED can be changed. The four LEDs can also be controlled programmatically with the SDK and the GPIO commands. Document Technical Specification version: v1.00 status: date: 2014-11-06 project title: PUR-SCANIT-350U HILTI – User Manual org 20141106_EN_UM - PUR-SCANIT- 350U Hilti_v1.00.docx created by: Stefan Detter page: 5 von 5 RF-Embedded GmbH • Kufsteiner Straße 11 • D-83080 Oberaudorf • [email protected] www.rf-embedded.eu Declaration of Conformity for USA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Usually this is followed by the following FCC caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Special advice for carriers of cardiac pacemakers: Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 20 cm between the device and your cardiac pacemaker.
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 11 Antenna description PADesignator101 PADesignator102 CODesignator1
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 1 External Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 4 Label Sample Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Label sample Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Label location
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 2 Internal Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920
RF exposure calculation Regulation FCC Part 15.247(i) Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See § 1.1307(b)(1) of this Chapter. MPE calculation to FCC ID: PTS350HILTI These equations are generally accurate in the far field of an antenna but will over predict power density in the near field, where they could be used for making a “worst case” prediction. S = PG/4πR 2 where S = power density ( in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units e.g. mW) G = power gain of the antenna in the direction of interest relative to the isotropic radiator R = distance to the center of radiation of the antenna (appropriate units e.g. cm) Or S = EIRP/(4πR 2 ) where EIRP = equivalent isotropically radiated power Calculation: (Calculated for max. EIRP) EIRP: 19.4 dBm = 87.1 mW calculated at distance of 20 cm: power density = 87.1 /(4*π*20 2 ) = 0.0173 mW/ cm 2 Limit: 0.451 mW/ cm 2 is the reference level for general public exposure according to the OET Bulletin 65, Edition 97-01 Table 1.
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 3 Occupied Bandwidth and Timing Plots Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Modulation bandwidth lowest frequency Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Modulation bandwidth middle frequency Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Modulation bandwidth highest frequency Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Hopping Channels Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Channel spacing Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Transmission times (worst case) 902.750 MHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Transmission times (worst case) 915.250 MHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Transmission times (worst case) 927.250 MHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 There are 50 hopping frequencies in use, the maximum 20 dB bandwidth is 107.1 kHz and the average time of occupancy is 383.5 msec.
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 12 Spurious emission Plot Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Conducted spurious emission: 12 MHz up to 30 MHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Conducted spurious emission: 30 MHz up to 1 GHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Conducted spurious emission: 1 MHz up to 7 GHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Conducted spurious emission: 1 MHz up to 7 GHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Conducted spurious emission: 7 GHz up to 12.75 GHz Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Out of band emission
Test report no. 14009595 Page 1 of 45 EUT: PUR–SCANIT–350U FCC ID: PTSPUR350HILTI FCC Title 47 CFR Part 15 Date of issue: 2015-01-14 Date: 2015-01-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to RF-Embedded GmbH PUR-SCANIT-350U Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 14009595 Page 2 of 45 EUT: PUR–SCANIT–350U FCC ID: PTSPUR350HILTI FCC Title 47 CFR Part 15 Date of issue: 2015-01-14 Date: 2015-01-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 MANUFACTURER Manufacturer name RF-Embedded GmbH Manufacturer’s grantee code PTS Manufacturer’s address Kufsteiner Str. 11, 83030 Oberaudorf, Germany Phone +49 (0) 8033 302313 0 Fax +49 (0) 8033 302313 88 Email [email protected] TESTING LABORATORY Test engineer Mr. Ralf Trepper Testing laboratory name m. dudde hochfrequenz-technik Testing laboratory address Rottland 5a, 51429 Bergisch Gladbach, Germany Phone +49 2207 96890 Fax +49 2207 968920 Email [email protected] RELEVANT STANDARD Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart Subpart C – Intentional Radiators Measurement procedure ANSI C63.4-2009 EQUIPMENT UNDER TEST (EUT) Equipment category RFID-Reader, Wideband transmission system Trade name RF-Embedded Type designation PUR-SCANIT-350U Serial no. --- Variants --- Test report no. 14009595 Page 3 of 45 EUT: PUR–SCANIT–350U FCC ID: PTSPUR350HILTI FCC Title 47 CFR Part 15 Date of issue: 2015-01-14 Date: 2015-01-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 1. Test result summary Clause Requirements headline Test result Page number 8.1 Antenna requirement Pass Fail N.t.* 10 8.2 Conducted limits Pass Fail N.t.* 11-13 8.3 Restricted bands of operation Pass Fail N.t.* 14-17 8.4 Radiated emission limits, general requirements Pass Fail N.t.* 18-24 8.5 Bandwidth Pass Fail N.t.* 25-26 8.6 Peak output power Pass Fail N.t.* 27-31 8.7 Out of band emissions Pass Fail N.t.* 32-35 8.8 Power spectral density Pass Fail N.t.* 36-37 8.9 Radio frequency hazard Pass Fail N.t.* 38 * Not tested The equipment passed the conducted tests Yes No Signature Name Ralf Trepper Manfried Dudde Designation Technician Laboratory-Manager Date of issue 2015-01-14 2015-01-14 Test report no. 14009595 Page 4 of 45 EUT: PUR–SCANIT–350U FCC ID: PTSPUR350HILTI FCC Title 47 CFR Part 15 Date of issue: 2015-01-14 Date: 2015-01-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Table of contents 1. Test result summary .......................................................................................................................................... 3 2. Introduction ...................................................................................................................................................... 6 3. Testing laboratory ............................................................................................................................................ 6 4. Applicant .......................................................................................................................................................... 7 5. Product ............................................................................................................................................................. 7 6. Conclusions, observations and comments ....................................................................................................... 8 7. Operational description ..................................................................................................................................... 9 8.1 Antenna requirement ....................................................................................................................................... 10 8.1.1 Regulation ............................................................................................................................................. 10 8.1.2 Result .................................................................................................................................................... 10 8.2 Conducted limits ............................................................................................................................................ 11 8.2.1 Regulation ............................................................................................................................................. 11 8.2.2 Test procedures ..................................................................................................................................... 11 8.2.3 Result .................................................................................................................................................... 12 8.3 Restricted bands of operation .......................................................................................................................... 14 8.3.1 Regulation ............................................................................................................................................. 14 8.3.2 Result .................................................................................................................................................... 17 8.4 Radiated emission limits, general requirements .............................................................................................. 18 8.4.1 Regulation ............................................................................................................................................. 18 8.4.2 Test procedure ............…
Text truncated - open the document above for the full version.
Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 6 Test Setup Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Radiated spurious emissions Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 AC port conducted spurious emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 310.00 mW |

PUR-SCANiT-350U UHF-RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
UHF RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
UHF RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter