PV3WFSLCDUIWireless Display Driver

Honeywell International Inc.
Wireless Display Driver - FCC ID PV3WFSLCDUI - Honeywell International Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 30, 2013
Application Purpose
Original Equipment
Date of Application
Dec 30, 2013
Equipment Note
Wireless Display Driver
Frequency Range
903.55000000 - 926.45000000
Company
Honeywell International Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FL P/N LS10036-000FL-E:FLRevECN FLECN Document LS10036-000FL-E 10/10/FLite Firelite Wireless Sensor Network LS10036-000FL-E User Manual PRELIMINARY 2PRELIMINARY: Firelite Wireless Sensor Network — P/N LS10036-000FL-E:N0 10/10/2013 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel (FACP) with remote notifi- cation capability—can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. An emergency communication system—typically made up of an automatic fire alarm system (as described above) and a life safety communication system that may include an autonomous control unit (ACU), local operating console (LOC), voice commu- nication, and other various interoperable communication meth- ods—can broadcast a mass notification message. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire or life safety event. The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premises following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. This document can be found at http:// www.systemsensor.com/appguides/. A study by the Federal Emergency Management Agency (an agency of the United States government) indicated that smoke detectors may not go off in as many as 35% of all fires. While fire alarm systems are designed to provide early warning against fire, they do not guarantee warning or protection against fire. A fire alarm system may not provide timely or adequate warning, or simply may not function, for a variety of reasons: Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second-floor detector, for example, may not sense a first-floor or basement fire. Particles of combustion or “smoke” from a developing fire may not reach the sensing chambers of smoke detectors because: • Barriers such as closed or partially closed doors, walls, chim- neys, even wet or humid areas may inhibit particle or smoke flow. • Smoke particles may become “cold,” stratify, and not reach the ceiling or upper walls where detectors are located. • Smoke particles may be blown away from detectors by air outlets, such as air conditioning vents. • Smoke particles may be drawn into air returns before reach- ing the detector. The amount of “smoke” present may be insufficient to alarm smoke detectors. Smoke detectors are designed to alarm at var- ious levels of smoke density. If such density levels are not cre- ated by a developing fire at the location of detectors, the detectors will not go into alarm. Smoke detectors, even when working properly, have sensing limitations. Detectors that have photoelectronic sensing cham- bers tend to detect smoldering fires better than flaming fires, which have little visible smoke. Detectors that have ionizing-type sensing chambers tend to detect fast-flaming fires better than smoldering fires. Because fires develop in different ways and are often unpredictable in their growth, neither type of detector is necessarily best and a given type of detector may not provide adequate warning of a fire. Smoke detectors cannot be expected to provide adequate warn- ing of fires caused by arson, children playing with matches (especially in bedrooms), smoking in bed, and violent explosions (caused by escaping gas, improper storage of flammable materi- als, etc.). Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined rate or reaches a predetermined level. Rate-of-rise heat detec- tors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Heat detectors are designed to protect property, not life. IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signaling, and/or power. If detectors are not so located, a devel- oping fire may damage the alarm system, compromising its abil- ity to report a fire. Audible warning devices such as bells, horns, strobes, speakers and displays may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. Any warning device may fail to alert people with a disability or those who have recently consumed drugs, alcohol, or medication. Please note that: • An emergency communication system may take priority over a fire alarm system in the event of a life safety emergency. • Voice messaging systems must be designed to meet intelligi- bility requirements as defined by NFPA, local codes, and Authorities Having Jurisdiction (AHJ). • Language and instructional requirements must be clearly dis- seminated on any local displays. • Strobes can, under certain circumstances, cause seizures in people with conditions such as epilepsy. • Studies have shown that certain people, even when they hear a fire alarm signal, do not respond to or comprehend the meaning of the signal. Audible devices, such as horns and bells, can have different tonal patterns and frequencies. It is…

Text truncated - open the document above for the full version.

External Photos

Wireless Display Driver - Internal and External Photos Top View Bottom View

ID Label/Location Info

50117737-001:A ECN 13-XXX 50117737-001-A 1.750" 0.719" Approvals Name Date Drawn By: Jamie K. Schmidt6/7/13 Technical Pubs: Quality Assurance: Marketing: Mech Doc Agency Listings: R.E.M.: Tolerances +/- 0.030" Unless otherwise specified, [A.S.A] standards are followed and all dimensions are in inches. 12 Clintonville Road, Northford, CT 06472 MATERIAL: Fasson Spec. # 08486 NO SUBSTITUTIONS! FINISH: Background: White. Linework and Lettering: Black. Used On:NOTIFIER accessories, per BOMs. Filename:5011-7737-001-A.pmd Title:DOC,LBL FCC ID PV3WFSLCDUI Document Number: 50117737001 Revision: A Sheet: 1 of 1 Initial Release Number: 13-484 Current ECN 13-xxx: Scale: 1:1 Notes: 1) Vendor: This is camera-ready artwork.Shoot at 100%. 2) MAKE SECURITY CUTS 1/8" INTO LABEL AT CENTER OF FOUR SIDES (see dotted lines on artwork) — SO LABEL WILL TEAR IF REMOVED. 3) PAPER USED MUST TEAR APART IF REMOVED FROM PRODUCT. 4)Cut at dimensions/crop marks illustrated. FCC ID PV3WFSLCDUI

Internal Photos

Internal Photo – 1 Internal Photo – 2 Formex Sheet PCB – Top View PCB –Bottom View Top Cover Bottom Cover

Test Report

Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 1 of 1 16 Wireless Display Driver Model No.: W-DIS-D Date: 22-Dec-2013 Report Prepared By: Sasikala Subramani EMC Test Report Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 2 of 1 16 Report Number EMC-1259-2 EUT Nomenclature Wireless Display Dr iver Sample Identification Model No. : W-DIS-D Sl. No. : 05313 Sof tw are Version : 5.82 Hardw are Version : Rev 3 Number of Samples 01 Date of receipt of Sample 26-08-2013 Condition of Sample on receipt Good Client name Honeyw ell Internat ional Inc. Client Address Honeyw ell Lif e Saf ety, 12 , Clint onville Road, Nort hf ord, Connect icut, USA - 06472 Testing Laboratory Honeyw ell Technology Solutions Lab Pvt. Ltd. Address RMZ ECOWORLD INFRASTRUCTURE PV T. LTD., (For merly Adarsh Pr ime Projects Pvt. Ltd., SEZ). Survey # 19/2, Devarabisanahalli Village, Varthur Hobli , Bangalore East Taluk, Bangalore – 560103 Test Dates 04-Aug-2013 t o 16-Dec-2013 Applicable Standard FCC Part 15 Subpart C Test Results PA SS Pr epared By: Technical Lead Rev iew ed By : Technical Manager Name : Sasikala Subramani Signature: Date : 23-Dec-2013 Rev iew ed By: Project Lead Name : Loganathan Joghee Signature: Date : 23-Dec-2013 Authorized By: Quality Manager Rev iew ed By : Technical Manager Name : Prasanna Kumar BT Signature: Date : 23-Dec-2013 Authorized By: Lab Manager Name : Ananth Krishna Signature: Date : 23-Dec-2013 This Report relates to the above mentioned test sample only. Without the approval of Lab manager, this report shall not be reproduced except in f ull. Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 3 of 1 16 TEST SUMMARY # Name Specification Test Method Pass Fail NA FHSS 1 20dB Bandw idth FCC Part 15.247 DA 00-705 2 Maximum Peak Output Pow er FCC Part 15.247 DA 00-705 3 Carrier Frequency Separat ion FCC Part 15.247 DA 00-705 4 Number of Hopping Frequencies FCC Part 15.247 DA 00-705 5 Band-edge Compliance FCC Part 15.247 DA 00-705 6 Time of Occupancy (Dw ell Time) FCC Part 15.247 DA 00-705 7 Spurious RF Conducted Emissions FCC Part 15.247 DA 00-705 8 Spurious Radiated Emissions FCC Part 15.247 and 15.209 DA 00-705 DTS 1 DTS 6dB Bandw idth FCC Part 15.247 KDB 558074 2 Maximum Peak Output Pow er FCC Part 15.247 KDB 558074 3 Maximum Pow er Spectral Density FCC Part 15.247 KDB 558074 4 Band-edge Conducted Emissions FCC Part 15.247 KDB 558074 5 Radiated Spurious Emissions FCC Part 15.247 and 15.209 KDB 558074 MEASUREMENT UNCERTAINTY Where relevant, the f ollow ing measurement uncertainty levels has been estimated f or tests perf ormed on the EUT as specif ied in CISPR 16-4 The Expanded measurement uncertainty (K=2) is provided below # Name Value 1 20dB and 6dB bandw idth 1.4dB 2 Maximum Peak Output Pow er 1.4dB 3 Maximum Pow er Spectral Density 1.4dB 4 Band-edge Emissions 1.4dB 5 Spurious RF Conduted Emissions 1.4dB 6 Radiated Spurious Emissions 4.9dB 7 Radiated Spurious Emissions 6.3dB Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 4 of 1 16 1 PRODUCT DETAILS PRODUCT OPERATION AND INTENDED USE The W-DIS-D is a part of the w ireless netw ork and has a specif ic SLC module address. The WDIS-D and ANN-80 display t he w ireless specif ic events that cannot be displayed on t he FA CP. These w ireless events are related to t he trouble and supervisory condit ions that are specif ic to t he Wireless Gat ew ay and devices. W-DIS-D can be pow ered by external 24Vdc int erf ace f rom Fire Panel. It uses propriet ary w ireless protocol to communicate w ith w ireless f ire devices. RATINGS AND SYSTEM DETAILS Operating Frequency 902MHz to 928MHz Number of Channels DTS :6 FHSS :52 Channel Bandw idth (20dB) DTS :1MHz FHSS :320 KHz Transmitted Power DTS :12dBm & 2dBm FHSS :17dBm Modulation Type FSK Data Rate DTS : 300Kbps FHSS :150Kbps Antenna Type Inverted F Patch Antenna No. of Antenna 4 Antenna Gain 3dBi Supply Voltage and Current 24V, 30mA Dimensions ( Diameter x Height ) 193 mm x 46mm Env ironmental Conditions Operat ing Temperature :0°C t o 49°C Storage Temperature : -10°C t o 60°C Humidity :10% to 93% RH Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 5 of 1 16 TEST CONFIGURATION Config # Description Conducted Test EUT is Pow ered by external 24Vdc int erf ace f rom the Fire Panel. EUT Debug port ( UA RT) is connected to Lapt op through USB to UA RT converter cable. EUT is conf igured to the respective operat ing mode through HyperTer minal. Antenna 1 is selected f or the test as this is t he only trans mitting antenna in the f ield. Radiated Test EUT is Powered by external 24Vdc int erf ace f rom the Fire Panel. EUT Debug port ( UA RT) is connected to Lapt op through USB to UA RT converter cable. EUT is conf igured to the respective operat ing mode through HyperTer minal. Antenna 1 is selected f or the test as this is t he only trans mitting antenna in the f ield. OPERATING MODES Mode # Description DTS Follow ing DTS channels have been used f or Conducted (Cont inuous Trans mission) and Radiated (Pulsed Trans mission) Tests Channel 1 : 902.875MHz Channel 2 : 908.425MHz Channel 3 : 914.325MHz Channel 4 : 915.325MHz Channel 5 : 921.575MHz Channel 6 : 927.125MHz FHSS Follow ing FHSS channels have been used f or Conducted ( Cont inuous Trans mission) and Radiated (Continuous Trans mission) Tests Channel 1 : 903.55MHz Channel 27 : 916.35MHz Channel 52 : 926.45MHz INPUT AND OUTPUT CABLES Port # Nam e Port Type Cable Length Cable type Shielded/ Unshielded Comments 1 External 24V Power Interface Cable Input 5m Unshielded *Note: AC = AC Pow er Port DC = DC Pow er Port TP = Telecommunicat ion Ports (eg. Ethernet) DI/ DO = Digital Input/ Out put N/ E = Non-Electrical AI/ AO = Analog Input/ Out put SUPPORT EQUIPMENTS AND ACCESSORIES USED # Item Description Make Model Part No. / Sl. No Cal Due Date 1 Laptop DELL E6400 3351399400 NA 2 USB t o UA RT Cable FTDI NA TTL-232R-3…

Text truncated - open the document above for the full version.

Test Report

Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 59 of 116 2.8 SPURIOUS RADIATED EMISSIONS EUT Nomenclature Wireless Display Dr iver Test Request No. EMC-1259-2 Model No. W-DIS-D Serial No. 05313 Test Start Date 11-Sep-2013 Temperature ( ̊C) 23.5 Test End Date 23-Sep-2013 Humidity RH (%) 57.2 Tested By Sasikala Subramani Pressure (mbar) NR Input Voltage / Freq 24 Vdc Operating Mode Ref er Page 5 f or Operat ing Mode Table Test configuration Ref er Page 5 f or Test Conf iguration Table Deviation from Std NA Comment TEST FREQUENCY RANGE Start Frequency 9KHz Stop Frequency 10GHz MAXIMUM OPERATING FREQUENCY 902MHz - 928MHz TEST PARAMETERS Antenna Height 1m to 4m Turn table Rotation 0° to 360° Applicable standard FCC Part 15.247 & 15.209 Test Method DA 00-705 Equipment Class NA Measurement Distance 3m TEST EQUIPMENT Y/N Equipment Make Model Serial Number Cal Due Date Y EMI Test Receiver R&S ESU26 100229 04-Feb-2014 Y 3m Semi Anechoic Chamber ETS Lindgren DKE 6X7 DBL. DR 1625 31-Dec-2013 Y Double Ridge Guide Horn Antenna ETS Lindgren 3117 00064055 07-Nov-2013 Y Bilog Antenna ETS Lindgren HLP3003C 130525 30-Nov-2013 Y Loop Antenna ETS Lindgren 6507 000103694 12-Mar-2014 Y RF cable (9KHz to 1GHz) COLEMA N RG214 RE-1A 09-May-2014 Y RF cable (9KHz to 1GHz) COLEMA N RG214 RE-1B 09-May-2014 Y RF cable (1GHz to 18GHz) AH Systems SAC-18G-06 RE-2A 09-May-2014 Y RF cable (1GHz to 18GHz) AH Systems SAC-18G-06 RE-2B 09-May-2014 Y Signal Conditioning unit R&S SCU-18 10178 13-June-2014 Y High Pass Filt er Wainw right WHKX1.5/15G-12ST 1 09-May-2014 Y EMC32 Sof tw are R&S 8.30.0 820-OT101248 NA Note: Switch ON /OFF the Internal Preamplifier based on carrier level and or noise floor without overloading the receiver. Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 60 of 116 TEST GRAPHS – 9KHz to 30MHz Channel 1 (903.55 M Hz) Note : Peak Graph - Parallel Channel 1 (903.55 M Hz) Note : Peak Graph - Perpendicular Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 61 of 116 Channel 27 (916.35 M Hz) Note : Peak Graph - Parallel Channel 27 (916.35 M Hz) Note : Peak Graph - Perpendicular Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 62 of 116 Channel 52 (926.45 M Hz) Not e : Peak Graph - Parallel Channel 52 (926.45 M Hz) Note : Peak Graph - Perpendicular Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 63 of 116 TEST RESULT – 9KHz to 30MHz Channel Channel Frequency Measured Spurious Quasi Peak Height Ant Pol Azimuth Margin Limit @ 3m Distance Results # MHz MHz dBμV/ m cm Parallel / Perpendicular deg dB dBμV/m NO EMISSIONS FOUND PASS Note : Measured Field Strength –dBuV/m = Receiver Readings (dBuV) + Antenna Factor (dB/m) + Cable loss (dB) Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 64 of 116 TEST GRAPHS – 30 MHz to 1 GHz 0 10 20 30 40 50 60 70 80 90 100 110 30 M 5060 80100 M20 030 040 050 0 80 01G Le vel i n dB μV /m F re q u e n c y in H z El ec t r ic Fi el d St r e ngt h wi t h S weep s CIS P R2 2 F C C P a rt 1 5 C la s s B E le c t ric F ie ld S t re n g t h Q P + A V Channel 1 (903.55 M Hz) Note : Peak Graph Vertical (Red), Peak Graph Horizontal (Blue) 10 20 30 40 50 60 70 80 90 100 110 30 M 5060 80100 M20 030 040 050 0 80 01G Le vel i n dB μV /m F re q u e n c y in H z El ec t r ic Fi el d St r e ngt h wi t h S weep s CIS P R2 2 F C C P a rt 1 5 C la s s A E le c t ric F ie ld S t re n g t h Q P + A V Channel 27 (916.35 M Hz) Note : Peak Graph Vertical (Red), Peak Graph Horizontal (Blue) Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 65 of 116 TEST RESULT – 30 MHz to 1 GHz Channel Measured Spurious Quasi Peak Height Ant Pol Azimuth Margin Limit @ 3m Distance Results # MHz dBμV/m cm H / V deg dB dBμV/m 1 30.11 23.2 100 V 240 16.8 40 PA SS 1 44.42 21.5 100 V 120 18.5 40 PA SS 1 69.56 18.3 200 V 240 21.7 40 PA SS 1 87.74 17.8 400 H 90 22.2 40 PA SS 1 165.96 22.4 100 V 0 21.1 43.5 PA SS 1 209.72 23.2 300 H 120 20.3 43.5 PA SS 1 344.57 25.8 100 H 60 20.2 46 PA SS 1 461.61 27.8 400 V 240 18.2 46 PA SS 1 697.85 34.4 300 H 300 11.6 46 PA SS 1 903.61 108.6 100 V 180 -50.6 46 Intended Frequency 27 30.13 26.7 100 V 150 12.3 39 PASS 27 50.53 18.6 400 H 60 20.4 39 PA SS 27 65.08 17.8 100 H 180 21.2 39 PA SS 27 86.15 17.6 100 H 330 21.4 39 PA SS 27 172.45 23.2 300 H 0 20.3 43.5 PA SS 27 208.34 23.1 100 H 180 20.4 43.5 PA SS 10 20 30 40 50 60 70 80 90 100 110 30 M 5060 80100 M20 030 040 050 0 80 01G Le vel i n dB μV /m F re q u e n c y in H z El ec t r ic Fi el d St r e ngt h wi t h S weep s CIS P R2 2 F C C P a rt 1 5 C la s s A E le c t ric F ie ld S t re n g t h Q P + A V Channel 52 (926.45 M Hz) Note : Peak Graph Vertical (Red), Peak Graph Horizontal (Blue) Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 66 of 116 27 346.35 25.8 300 H 120 20.6 46.4 PA SS 27 479.52 28.1 200 V 210 18.3 46.4 PA SS 27 656.63 33.2 300 V 240 13.2 46.4 PA SS 27 916.41 107.3 100 V 0 -48.9 46.4 Intended Frequency 52 30.02 27.4 100 V 330 11.6 39 PA SS 52 52.16 18.4 400 H 0 20.6 39 PA SS 52 67.51 18.1 100 V 210 20.9 39 PA SS 52 85.97 17 300 V 180 22 39 PA SS 52 168.33 23.1 200 H 0 20.4 43.5 PA SS 52 202.74 23.5 400 H 240 20 43.5 PA SS 52 346.92 25.9 300 H 330 20.5 46.4 PA SS 52 483.89 28.7 300 H 30 17.7 46.4 PA SS 52 701.08 34.5 300 H 60 11.9 46.4 PA SS 52 926.5 110.6 100 V 330 -52.2 46.4 Intended Frequency NOTE: Measured Field Strengt h –dBuV/ m (9 KHz to 1GHz) = Receiver Readings (dBuV) + Antenna Factor (dB/ m) + Cable loss (dB) Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 67 of 116 TEST GRAPHS – 1 GHz to 10 GHz Channel 1 (903.55 M Hz) Note: Peak Graph - Horizontal Channel 1 (903.55 M Hz) Note: Peak Graph – Vertical Honeywell Technology Solutions Honeywell Confi dentia l and Prop rieta ry Page 68 of 116 Channel 27 (916.35 M Hz) Note: Peak Graph - Horizontal Channel 27 …

Text truncated - open the document above for the full version.

Test Setup Photos

Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 1 of 6 Wireless Display Driver –Test Setup Photos Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 2 of 6 CONDUCTED RF TEST SETUP Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 3 of 6 RADIATED EMISSION TEST SETUP EUT AUXILIARY SETUP Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 4 of 6 Radiated Emission Setup – 9 KHz to 30 MHz [ Parallel ] Radiated Emission Setup – 9 KHz to 30 MHz [ Perpendicular ] Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 5 of 6 Radiated Emission Setup – 30 MHz to 1 GHz [ Horizontal ] Radiated Emission Setup – 30 MHz to 1 GHz [ Vertical ] Honeywell Technology Solutions Honeywell Confidential and Proprietary Page 6 of 6 Radiated Emission Setup – 1 GHz to 10 GHz [ Horizontal ] Radiated Emission Setup – 1 GHz to 10 GHz [ Vertical ]

Contact Information

Applicant

Jonathan Potter(Senior Engineering Manager)
[email protected]203-484-6405Fax: 203-484-7309

Test Firm

Honeywell Technology Solutions Lab Pvt. LtdMr. Prasanna Kumar BudalTaranath
[email protected]91-80-39888400Fax: 91-80-39834455

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903.55 MHz - 926.45 MHz50.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEMs and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Honeywell International Inc.

GLSS Gateway - FCC ID PV3CGWMB - Honeywell International Inc.
PV3CGWMB

GLSS Gateway

Feb 13, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Gateway - FCC ID PV3WFSGW - Honeywell International Inc.
PV3WFSGW

Wireless Gateway

Dec 30, 2013

Equipment Class

DTS - Digital Transmission System
USB Adapter - FCC ID PV3WFSADPT - Honeywell International Inc.
PV3WFSADPT

USB Adapter

Dec 30, 2013

Equipment Class

DTS - Digital Transmission System