FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. The House of Marley.LLC/
  3. PVB-EMJT304

PVB-EMJT304Revolution with Speakers, Revolution

The House of Marley.LLC

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 25, 2024
Application Purpose
Original Equipment
Date of Application
Jul 24, 2024
Equipment Note
Revolution with Speakers, Revolution
Frequency Range
2402.00000000 - 2480.00000000
Company
The House of Marley.LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM2403WDG0249 RF EXPOSURE REPORT Applicant The House of Marley. LLC Address 3000 Pontiac Trail, Commerce Township, Michigan 48390 United States Manufacturer or Supplier The House of Marley. LLC Address 3000 Pontiac Trail, Commerce Township, Michigan 48390 United States Product Revolution with speakers, Revolution Brand Name Marley, Model EM-JT304 Additional Model & Model Difference EM-JT004, see item 1 Date of tests Apr. 25, 2024 ~ May 28, 2024 FCC Part 2 (Section 2.1091) KDB 447498 D01 V06 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Niko Zhang Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Jul. 22, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM2403WDG0249 Table of Contents RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE LIMIT ..................................................................................... 5 3. MPE CALCULATION FORMULA ..................................................................... 5 4. CLASSIFICATION ........................................................................................... 5 5. ANTENNA GAIN .............................................................................................. 6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM2403WDG0249 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2403WDG0249 Original release Jul. 22, 2024 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM2403WDG0249 1. CERTIFICATION FCC ID: PVB-EMJT304 PRODUCT: Revolution with speakers, Revolution BRAND NAME: Marley, MODEL NO.: EM-JT304 ADDITIONAL NO.: EM-JT004 APPLICANT: The House of Marley. LLC STANDARDS: FCC Part 2 (Section 2.1091) KDB 447498 D01 V06 IEEE C95.1 NOTE: Additional models (see below table) are identical with the test model EM-JT304 except the external speakers, product name and model no. for trading purpose. Product Name Model No. Different Revolution with speakers EM-JT304 With External Speakers Revolution EM-JT004 Without External Speakers Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM2403WDG0249 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center…

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 12 Report Version B Test Report No.: AN2210WDG0152 ANTENNA TEST REPORT Applicant Guangdong Leetac Electronics Technology Co .,Ltd. Address No.15 Danli Road, South District, Zhongshan, Guangdong, China. Manufacturer or Supplier Guangdong Leetac Electronics Technology Co .,Ltd. Address No.15 Danli Road, South District, Zhongshan, Guangdong, China. Product Antenna Brand Name N/A Model ANT02 Max. Peak Gain 0.26 dBi Date of tests Dec. 13, 2022 Tested by Andy Zhu Supervisor / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Dec. 19, 2022 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 12 Report Version B Test Report No.: AN2210WDG0152 TABLE OF CONTENTS 1. MEASUREMENTS SETUP ..................................................................................................................3 2. SIZE OF THE ANTENNA .....................................................................................................................3 3. TEST INSTRUMENTS .........................................................................................................................4 4. TEST RESULTS ...................................................................................................................................5 5. PHOTOGRAPHS OF THE TEST CONFIGURATION....................................................................... 12 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 12 Report Version B Test Report No.: AN2210WDG0152 1. MEASUREMENTS SETUP 2. SIZE OF THE ANTENNA Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 12 Report Version B Test Report No.: AN2210WDG0152 3. TEST INSTRUMENTS Equipment Manufacturer Model No. Serial No. Next Cal. Signal Generator Agilent N5183A MY50140980 Jul. 20, 23 Spectrum Analyzer Rohde&Schwarz FSV40 101003 Jan. 16, 23 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 D 9120D-1247 Apr. 23, 23 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 B 00740 Jul. 20, 23 Turn Table MF MF-7802 MF780208191 N/A Controller MF MF-7802 MF780208243 N/A Test Software BV ADT BV ADT Antenna Pattern V6.2 N/A NOTE: 1. The test was performed in Fully Anechoic Room. 2. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 12 Report Version B Test Report No.: AN2210WDG0152 4. TEST RESULTS ANTENNA FREQUENCY (MHz) ANTENNA POLARITY MAX. PEAK GAIN (dBi) PCB 2402 Horizontal -0.86 Vertical -1.13 2440 Horizontal 0.10 Vertical -0.47 2480 Horizontal 0.26 Vertical -0.30 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 12 Report Version B Test Report No.: AN2210WDG0152 Frequency: 2402 MHz (Horizontal) Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 7 of 12 Report Version B Test …

Text truncated - open the document above for the full version.

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 58 Report Version 1 Test Report No.: RF2403WDG0249 TEST REPORT Applicant The House of Marley. LLC Address 3000 Pontiac Trail, Commerce Township, Michigan 48390 United States Manufacturer or Supplier The House of Marley. LLC Address 3000 Pontiac Trail, Commerce Township, Michigan 48390 United States Product Revolution with speakers, Revolution Brand Name Marley, Model EM-JT304 Additional Model & Model Difference EM-JT004, see item 3.1 Date of tests Apr. 25, 2024 ~ May 28, 2024 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Niko Zhang Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Jul. 24, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 58 Report Version 1 Test Report No.: RF2403WDG0249 TABLE OF CONTENTS RELEASE CONTROL RECORD ..................................................................................................... 5 1 SUMMARY OF TEST RESULTS ............................................................................................. 6 2 MEASUREMENT UNCERTAINTY .......................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ............................................................................... 7 3.2 DESCRIPTION OF TEST MODES ................................................................................. 8 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST .................................................... 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................. 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS .......................................................................... 11 3.5 CONFIGURATION OF SYSTEM UNDER TEST ........................................................... 11 3.6 DUTY CYCLE OF TESET SIGNAL ............................................................................... 12 4 TEST TYPES AND RESULTS ............................................................................................... 13 4.1. CONDUCTED EMISSION MEASUREMENT ............................................................... 13 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ........................................ 13 4.1.2 TEST INSTRUMENTS .............................................................................................. 13 4.1.3 TEST PROCEDURES .............................................................................................. 14 4.1.4 DEVIATION FROM TEST STANDARD .................................................................... 14 4.1.5 TEST SETUP ............................................................................................................ 15 4.1.6 EUT OPERATING CONDITIONS ............................................................................. 15 4.1.7 TEST RESULTS........................................................................................................ 16 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT ....................................... 18 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ................ 18 4.2.2 TEST INSTRUMENTS .............................................................................................. 19 4.2.3 TEST PROCEDURES .............................................................................................. 20 4.2.4 DEVIATION FROM TEST STANDARD .................................................................... 21 4.2.5 TEST SETUP ..............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Sean Roe(Senior Product Development Manager-House of Marly)
[email protected]8013627820Fax: 2488633100

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.12 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from The House of Marley.LLC

Kaya - FCC ID PVB-EMCD001SB - The House of Marley.LLC
PVB-EMCD001SB

Kaya

Jul 24, 2026

Equipment Class

DTS - Digital Transmission System
Aura ANC - FCC ID PVB-EMDE045 - The House of Marley.LLC
PVB-EMDE045

Aura ANC

Jul 03, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Trenchtown ANC - FCC ID PVB-EMDE041 - The House of Marley.LLC
PVB-EMDE041

Trenchtown ANC

Nov 26, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
POSITIVE VIBRATION RIDDIM - FCC ID PVB-EMJH135 - The House of Marley.LLC
PVB-EMJH135

POSITIVE VIBRATION RIDDIM

Sep 25, 2024

Equipment Class

DTS - Digital Transmission System
PVB-EMJA027

Uplift

Jul 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter