Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 24, 2013
Application Purpose
Original Equipment
Date of Application
Jul 20, 2013
Equipment Note
Get Up Stand Up BT
Frequency Range
2402.00000000 - 2480.00000000
Company
The House of Marley.LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 2 Connecting multiple devicesWhen a device is connected to Bluetooth and another device is connected via auxiliary input, the color of the indicates the source. If the LED glows blue, the Bluetooth device will play. When red, the auxiliary input will play. Toggle between inputs by briefly pressing the . Easy To Use When the system is powered and a device is connected, you are ready to enjoy your Get Up Stand Up. 1. Press the power button to turn Get Up Stand Up on. Press the power button again to turn Get Up Stand Up off. The red LED on the power icon indicates if the Get Up Stand Up is on. 2. Increase or decrease the volume on the Get Up Stand Up by touching and/or holding the – and + buttons until the desired volume is reached. You can also adjust the system volume using the controls on your music source. Charging Your DeviceA convenient USB port is available on the back of Get Up Stand Up to charge your devices while it is on. Use the cable that came with your device to charge.NOTE: Not all devices are compatible with the USB port. If your device does not charge, use the power adapter that came with it. Important Safety Information 1. Follow and keep these instructions. 2. Heed all warnings. 3. Do not use this apparatus near water. 4. Clean only with a dry cloth. 5. Do not block any ventilation openings. Install in accordance with the ma nufacturer’s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Protect the power cord from being walked on or pinched particularly at plug, convenience receptacles, and the point where they exit from the apparatus. 8. Only use attachments/accessories specified by the manufacturer. 9. Unplug this apparatus during lightning storms or when unused for long periods of time. 10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 11. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. WEEE EXPLANATION This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of materi al resources. To return your used device, please use the return and collection systems or contact the retail er where the product was purchased. They can take this product for environmental safe recycling. Get Up Stand UpBluetooth ® Audio System Greetings and Welcome to the House of MarleyWe are honored you have selected Get Up Stand Up to become part of your music experience. The Get Up Stand Up is a two-way, stereo sound system which works with Bluetooth ® devices connected wirelessly and hundreds of other devices via the auxiliary input. The system uses two high-output, long-throw 4.5” (100mm) woofers in a ported enclosure, two 1” (25mm) tweeters and a powerful amplifier. Powering Your Get Up Stand UpYour Get Up Stand Up uses a universal power supply (100-240VAC) and is powered by a standard wall outlet.1. Insert the AC power supply cord into Get Up Stand Up. 2. Insert wall plug cord connector into the power supply.3. Insert wall plug into an appropriate wall outlet.Connecting Your Music Device(s)Pairing Mode (Blinking Blue LED)Get Up Stand Up automatically goes into reconnect mode for 5 seconds as soon as you turn it on (flashing BLUE led). It then switches to auxiliary mode (RED led). You can pair a new device to Get Up Stand Up by holding the for 3 seconds. Note: Holding the for 3 seconds will kick off the device currently connected to Get Up Stand Up and go into Pairing Mode. Connected Mode (Solid Blue LED)Use your Bluetooth-enabled device to pair to Get Up Stand Up. Get Up Stand Up does not require a pairing password. Once paired, the LED will glow solid blue.Note: Get Up Stand Up will automatically pair with the last device connected to it when turned ON (when possible).Connecting other devicesThe auxiliary inputs on the back of Get Up Stand Up allow you to connect other audio devices to the system. Simply connect your device(s) to either AUX 1 or AUX 2 using the 3.5mm stereo cable or standard composite cables (not included). EN 123 Sound System Remote AC Power Supply(100-240 VAC) 3.5mm Stereo Mini Cable Power Cord for Wall Outlet Everything You Need to JamGet Up Stand Up comes with the following items: BT FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC and IC Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device complies with Part 15 of the FCC Rules and Industry Canada …

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 03 Declaration of Authorization We Name: The House of Marley.LLC Address: 3000 Pontiac Trail Commerce Township City: Oaklang Country: United States Declare that: Name Representative of agent: Cathy Wang Agent Company name: ​Neutron Engineering, Inc. Address: No.3 Jinshagang 1 st Road, Shixia, Dalang Town City: Dong Guan Country: China is authoriz ed to apply for Certific ation of the following produc t(s ): Product description:​Get Up Stand Up BT Type designation: EM-FA001-PT Trademark:​MARLEY on our behalf. Date:​2013-6-21 City:​Oaklang Name:​Vladislav Grodzinskiy Function: ​manager Signature: ​-----------------------------------------

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: The House of Marley.LLC Address: 3000 Pontiac Trail Commerce Township City: Oaklang Country: United States To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: PVBEMFA001TP Reference number: Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: 2013-6-21 Name and signature of applicant: Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Neutron Engineering Inc. Project No.: 1305C180 Page 2 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 3 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 4 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 5 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 6 of 15

Internal Photos

Neutron Engineering Inc. Project No.: 1305C180 Page 7 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 8 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 9 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 10 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 11 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 12 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 13 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 14 of 15 Neutron Engineering Inc. Project No.: 1305C180 Page 15 of 15

RF Exposure Info

Neutron Engineering Inc. Im FCC RF EXPOSURE REPORT FCC ID: PVBEMFA001TP Project No. : 1305C180 Equipment : Get Up Stand Up BT Model Name : EM-FA001-PT Applicant : The House of Marley, LLC Address : 3000 Pontiac Trail Commerce Township MI-48390, USA According: : FCC Guidelines for Human Exposure IEEE C95.1 Neutron Engineering Inc. No.3, Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. MPE CALCULATION METHOD: Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Ant. Brand name Model Name Antenna TypeConnector Gain (dBi) 1 N/A N/A PIFA N/A 0 Maximum measured transmitter power: Output Power (dBm) Out Power (mW) Limit (mW) 3.91 2.5 10 According to FCC KDB447498 V05, Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm The maximum measured output power of this EUT is 3.91dBm (2.5mW), less than 10mW at 5mm distance. Conclusion: No SAR evaluation required since transmitter power is below FCC threshold

Test Report

Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 1 of 96 FCC/IC Radio Test Report FCC ID: PVBEMFA001TP IC: 10613A-EMFA001TP This report concerns (check one) : Original Grant Class II Change Issued Date : Jun. 05, 2013 Project No. : 1305C180 Equipment : Get Up Stand Up BT Model Name : EM-FA001-PT Applicant : The House of Marley, LLC Address : 3000 Pontiac Trail Commerce Township MI-48390, USA Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: May. 28, 2013 Date of Test: May. 28, 2013~ Jun. 04, 2013 Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 2 of 96 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 3 of 96 Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 10 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS 15 4.2 RADIATED EMISSION MEASUREMENT 18 4.2.1 RADIATED EMISSION LIMITS 18 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 19 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 22 4.2.7 TEST RESULTS: 30MHZ - 1000MHZ 22 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 25 5 . NUMBER OF HOPPING CHANNEL 49 5.1 APPLIED PROCEDURES / LIMIT 49 5.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 49 5.1.2 TEST PROCEDURE 49 5.1.3 DEVIATION FROM STANDARD 49 5.1.4 TEST SETUP 49 5.1.5 EUT OPERATION CONDITIONS 49 5.1.6 TEST RESULTS 50 6 . AVERAGE TIME OF OCCUPANCY 52 Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 4 of 96 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 52 6.1.1 MEASUREMENT INSTRUMENTS LIST 52 6.1.2 TEST PROCEDURE 52 6.1.3 DEVIATION FROM STANDARD 52 6.1.4 TEST SETUP 53 6.1.5 EUT OPERATION CONDITIONS 53 6.1.6 TEST RESULTS 54 7 . HOPPING CHANNEL SEPARATION MEASUREMENT 66 7.1 APPLIED PROCEDURES / LIMIT 66 7.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 66 7.1.2 TEST PROCEDURE 66 7.1.3 DEVIATION FROM STANDARD 66 7.1.4 TEST SETUP 66 7.1.5 EUT OPERATION CONDITIONS 66 7.1.6 TEST RESULTS 67 8 . BANDWIDTH TEST 71 8.1 APPLIED PROCEDURES / LIMIT 71 8.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 71 8.1.2 TEST PROCEDURE 71 8.1.3 DEVIATION FROM STANDARD 71 8.1.4 TEST SETUP 71 8.1.5 EUT OPERATION CONDITIONS 71 8.1.6 TEST RESULTS 72 9 . PEAK OUTPUT POWER TEST 76 9.1 APPLIED PROCEDURES / LIMIT 76 9.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 76 9.1.2 TEST PROCEDURE 76 9.1.3 DEVIATION FROM STANDARD 76 9.1.4 TEST SETUP 76 9.1.5 EUT OPERATION CONDITIONS 76 9.1.6 TEST RESULTS 77 10 . ANTENNA CONDUCTED SPURIOUS EMISSION 81 10.1 APPLIED PROCEDURES / LIMIT 81 10.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 81 10.1.2 TEST PROCEDURE 81 10.1.3 DEVIATION FROM STANDARD 81 10.1.4 TEST SETUP 81 10.1.5 EUT OPERATION CONDITIONS 81 10.1.6 TEST RESULTS 82 11 . EUT TEST PHOTO 94 Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 5 of 96 1. CERTIFICATION E q u i p m e n t : Get Up Stand Up BT Brand Name : MARLEY Model Name : EM-FA001-PT A p p l i c a n t : The House of Marley, LLC Factory : Premium Loudspeakers (Huizhou) Co., Ltd Address : Tymphany Industrial Area Xinlian Village, Xinxu Town, Huizhou City , Date of Test : May. 28, 2013~ Jun. 04, 2013 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.247) / ANSI C63.4 : 2009 / FCC Public Notice DA 00-705, March 30, 2000. Canada RSS-210:2010 RSS-GEN Issue 3, Dec 2010 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FICP-1-1305C180) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment s…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 94 of 96 11. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 95 of 96 Radiated Measurement Photos 30MHz~1GHz Neutron Engineering Inc. Report No.: NEI-FICP-1-1305C180 Page 96 of 96 Radiated Measurement Photos Above 1GHz

Contact Information

Applicant

Cody Brooner(Head of Product)
[email protected]8057047670Fax: 2488633100

Technical Contact

Neutron Engineering, Inc.Steven Lu
[email protected]86-769-8318300

No.3 Jinshagang 1st Rd, Shixia, Dalang · China

Non-Technical Contact

Neutron Engineering, Inc.Cathy Wang
[email protected]86-769-8318300

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from The House of Marley.LLC

Kaya - FCC ID PVB-EMCD001SB - The House of Marley.LLC
PVB-EMCD001SB

Kaya

Jul 24, 2026

Equipment Class

DTS - Digital Transmission System
Aura ANC - FCC ID PVB-EMDE045 - The House of Marley.LLC
PVB-EMDE045

Aura ANC

Jul 03, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Trenchtown ANC - FCC ID PVB-EMDE041 - The House of Marley.LLC
PVB-EMDE041

Trenchtown ANC

Nov 26, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
POSITIVE VIBRATION RIDDIM - FCC ID PVB-EMJH135 - The House of Marley.LLC
PVB-EMJH135

POSITIVE VIBRATION RIDDIM

Sep 25, 2024

Equipment Class

DTS - Digital Transmission System
PVB-EMJA027

Uplift

Jul 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter