FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. BenQ Mobile GmbH & Co. OHG/
  3. PWX-C60

PWX-C60GSM 1900 Mobile Phone

BenQ Mobile GmbH & Co. OHG
GSM 1900 Mobile Phone - FCC ID PWX-C60 - BenQ Mobile GmbH & Co. OHG
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Sep 28, 2003
Application Purpose
Original Equipment
Date of Application
Sep 28, 2003
Equipment Note
GSM 1900 Mobile Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
BenQ Mobile GmbH & Co. OHG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

right page (1) of C60 Lion, short, am A31008-H5850-A40-1-4A19 (08.08.2003, 10:13) © Siemens AG 2003, G:\Mobil\L55\C60_Lion\am\SUG\C60K_LionIVZ.fm Table of Contents1 VAR Language: English; VAR issue date: 11-Juli-2003 This is a short version of the operating instructions. You can download the detailed version from the Internet at: www.my- siemens.com/c60 Safety precautions ..................... 2 SAR (Cell Phone Designation) .... 4 Phone overview ......................... 6 Display symbols (selection) ....... 8 Getting started ......................... 10 Switching on/off, PIN ............... 13 Switching on your phone for the first time .......................... 13 Without a SIM card ................. 14 General information ................ 16 Security .................................... 17 Codes .................................... 17 Clear SIM card barring ............ 18 Making a phone call ................. 19 Text entry ................................. 22 Predef. texts .......................... 25 Phonebook ............................... 26 <New entry> .......................... 26 Call (search for an entry) ........ 26 Edit entry ............................... 26 Assign picture ........................ 27 Groups ................................... 28 Records/Durat/charges ............. 29 Camera (Accessories) ............... 30 Voicemail/CB services .............. 32 SMS .......................................... 33 MMS ......................................... 34 Message lists/ Message list settings ............... 36 Surf & fun ................................. 37 Internet browser (WAP) .......... 37 Games .................................... 38 Setup ........................................ 39 Ring tones ................................ 45 Extras ........................................ 46 Alarm clock ............................ 46 Calculator ............................... 46 Stopwatch .............................. 46 SIM services (optional) ........... 46 Fast access ................................ 47 Own stuff .................................. 48 Questions & Answers ............... 49 Customer Care .......................... 52 Specifications ........................... 54 Exposure to radiofrequency signals ............ 54 Technical data ....................... 54 Trademarks ............................ 54 Care and maintenance ............. 55 Battery quality statement ........ 56 U.S. FDA .................................... 57 FCC/Industry Canada Notice ..... 63 Ten Driving Safety Tips ............. 64 Intellectual Property ................. 66 Menu tree ................................. 67 Index ......................................... 72 Table of Con- tents This is a short version of the operating instructions. You can download the detailed ver- sion from the Internet at: www.my-sie- mens.com/c6 0 © Siemens AG 2003, G:\Mobil\L55\C60_Lion\am\SUG\C60K_Security.fm left page (2) of C60 Lion, short, am, A31008-H5850-A40-1-4A19 (08.08.2003, 10:13) Safety precautions 2 VAR Language: English; VAR issue date: 11-Juli-2003 Safety precautions Information for parents Please read the operating instructions and safety precautions carefully before use. Explain the content and the hazards associated with using the phone to your children. Remember to comply with legal requirements and local restric- tions when using the phone. For example in aeroplanes, petrol stations, hospitals or while driving. Mobile phones can interfere with the functioning of medical devices such as hearing aids or pacemakers. Keep at least 20 cm/9 inches between phone and pacemaker. When using the mobile phone hold it to the ear which is further away from the pacemaker. For more infor- mation consult your doctor. The SIM card and MultiMediaCard may be removed. Caution! Small parts like this could be swallowed by young children. The mains voltage specified on the power supply unit (Volt) must not be exceeded. Other- wise the charging device may be destroyed. The ringtone (p. 45), info tones and handsfree talking are repro- duced through the loudspeaker. Do not hold the phone to your ear when it rings or when you have switched on the handsfree function (p. 20). Otherwise you risk serious permanent damage to your hearing. Only use original Siemens bat- teries (100 % mercury-free) and – charging devices. Otherwise you risk serious damage to health and property. The battery could explode, for instance. You may only open the phone to replace the battery (100 % mer- cury-free), SIM card or MultiMediaCard. You must not open the battery under any circumstances. All other changes to this device are strictly prohibited and will invali- date the operating licence. right page (3) of C60 Lion, short, am, A31008-H5850-A40-1-4A19 (08.08.2003, 10:13) © Siemens AG 2003, G:\Mobil\L55\C60_Lion\am\SUG\C60K_Security.fm 3Safety precautions VAR Language: English; VAR issue date: 11-Juli-2003 Important: Please dispose of unwanted batteries and phones as permit- ted by the laws in your country. The phone may cause interfer- ence in the vicinity of TV sets, radios and PCs. Use only Siemens original accessories. This will avoid potential risks to health or prop- erty and ensure compliance with all relevant regulations. Improper use will invalidate the guarantee! © Siemens AG 2003, G:\Mobil\L55\C60_Lion\am\SUG\C60_SAR.fm left page (4) of C60 Lion, short, am, A31008-H5850-A40-1-4A19 (08.08.2003, 11:48) SAR (Cell Phone Designation) 4 VAR Language: English; VAR issue date: 11-Juli-2003 SAR (Cell Phone Designation) RF EXPOSURE /SPECIFIC ABSORPTION RATE (SAR) INFORMATION THIS SIEMENS C60 PHONE MEETS THE GOVERNMENT'S REQUIRE- MENTS FOR EXPOSURE TO ELECTRO- MAGNETIC FIELDS. Your cell phone is a radio transmitter and receiver. It is designed and man- ufactured not to exceed the emission limits for exposure to radio fre- quency (RF) energy established by the Federal Communications Com- mission (FCC) of the U.S. Govern- ment and by Health Can…

Text truncated - open the document above for the full version.

External Photos

C60 Front View C60 Back View C60 Side View C60 Side View

ID Label/Location Info

Date 17.06.03 Approval label Name Li Long Jun Standard IMEI-Label/C60 2 31.07.03 Li RD MP VC BJ 1 17.06.03 Li LETTERING PLAN Version Date Token SIEMENS AG DIS 42547 Page 1 From 1 A24850-V1-A4-2 VORSTD.DOC White label with black lettering SIEMENS S30880-SXXXX-XXXX-1 YY XXXXXXXX SSSSSS C 0682 Made xx Xxxxxxx 3) C60 Barcode: Typ 128, table C and B Characteristic: IMEI-No. has 15 digits Digit 1-14 is generated as Barcode with table C . Digit 15 is printed with table B. 1)2) 4) 5) 6) 7) 8) 9) 11) 12) XXXXXXXX Typ-Approval Code TAC SSSSSS Current serial number (6 digits), Assigned by PICS C CHECK DIGIT 15. digit 10) FCC ID: PWX-C60 IC:267E-C60 13) Ink ribbon: TTR-Band Ricoh 110-A Font: Title blocks concentric 1) Corporate logo: 1.5 SN 66324 2) Product name: Internal font D, size 4 3) Made xx Xxxxxxx Bitmap 4) Code of date: Internal font D, size 4 e.g. F3  March └─1995 5) Code number: Internal font D, size 4 6) CE- identification: Height: 5 mm according to BABT-Document 556 26/93 7) Barcode IMEI-No.: Code: 128 Size: 2 Ratio: 3.0 Height: 3 mm 8) IMEI-No. (plain writing): Internal font D, size 4, space between TAC, serial no. and 15.digit XXXXXXXX Typ-Approval Code TAC SSSSSS Current serial number (6 digits), Assigned by PICS C CHECK DIGIT 15. digit 9) Triangle: Height: 4 mm 10) Document for IMEI-No. allocation: DIS 37578 BOM 000 xx Valid is the highest level in the system 11) Code number: Corresponding to the number of the transceiver unit part list 12) Made xx Xxxxxxx Internal font B, size 3 / Depending on production location 13) Canada IC and US FCC font: B3

ID Label/Location Info

C60 Open battery cover (Final label: see extra exhibit)

Internal Photos

C60 Open battery cover (Final label: see extra exhibit) C60 Disassembly step 1 C60 Disassembly step 2 C60 Disassembly step 3 C60 GSM Tri-band Antenna C60 Board without shield

RF Exposure Info

TTI-P-G 158 DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 1 of 17 Appendix for the Report Dosimetric Assessment of the Siemens C60 (FCC ID: PWX-C60) According to the FCC Requirements SAR Distribution Plots July 30, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Siemens Information & Communication Mobile LLC 16475 West Bernado Drive, Suite 400 San Diego CA 92127 The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. dasy_report_fcc_supplemen t _c _2.0.doc/25.09.2001/CH DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 2 of 17 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Table of Contents 1 SAR DISTRIBUTION PLOTS, PCS 1900 HEAD WITHOUT QUICKPIC CAMERA............................. 3 2 SAR DISTRIBUTION PLOTS, PCS 1900 HEAD WITH QUICKPIC CAMERA ..................................... 7 3 SAR DISTRIBUTION PLOTS, PCS 1900 BODY WITH HEADSET........................................................ 11 4 SAR DISTRIBUTION PLOTS, PCS 1900 BODY WITH DATACABLE.................................................. 12 5 SAR DISTRIBUTION PLOTS, PCS 1900 BODY, C60 ............................................................................... 13 6 SAR Z-AXIS SCANS (VALIDATION) ......................................................................................................... 14 7 SAR Z-AXIS SCANS (MEASUREMENTS) .................................................................................................16 DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 3 of 17 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH 1 SAR Distribution Plots, PCS 1900 Head without QuickPic Camera Test Laboratory: IMST: File Name: c60plm_1.da4 DUT: Siemens; Type: C60; Serial: 004999002488244 Program: Measurement Communication System: GSM 1900; Frequency: 1880 MHz;Duty Cycle: 1:8 Medium: Head 1900 MHz (σ = 1.39 mho/m, ε r = 38.9, ρ = 1000 kg/m 3 ) Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(5.2, 5.2, 5.2); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1176; Type: SAM 4.0; Serial: 1176 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 cheek left/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 15.2 V/m Power Drift = 0.06 dB Maximum value of SAR = 0.304 mW/g cheek left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 0.454 W/kg SAR(1 g) = 0.307 mW/g; SAR(10 g) = 0.189 mW/g Reference Value = 15.2 V/m Power Drift = 0.06 dB Maximum value of SAR = 0.333 mW/g Fig. 1: SAR distribution for PCS 1900, channel 661, cheek position, left side of head. (28.07.2003; Liquid Temperature: 20.9° C; Ambient Temperature : 21.6° C). DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 4 of 17 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST; File Name: c60plm_2.da4 DUT: Siemens; Type: C60; Serial: 004999002488244 Program: Measurement Communication System: GSM 1900; Frequency: 1880 MHz;Duty Cycle: 1:8 Medium: Head 1900 MHz (σ = 1.39 mho/m, ε r = 38.9, ρ = 1000 kg/m 3 ) Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(5.2, 5.2, 5.2); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1176; Type: SAM 4.0; Serial: 1176 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 tilted left/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 15.2 V/m Power Drift = 0.1 dB Maximum value of SAR = 0.295 mW/g tilted left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 0.408 W/kg SAR(1 g) = 0.282 mW/g; SAR(10 g) = 0.172 mW/g Reference Value = 15.2 V/m Power Drift = 0.1 dB Maximum value of SAR = 0.308 mW/g Fig. 2: SAR distribution for PCS 1900, channel 661, tilted position, left side of head. (28.07.2003; Liquid Temperature: 20.9° C; Ambient Temperature : 21.6°C). DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 5 of 17 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST; File Name: c60prm_1.da4 DUT: Siemens; Type: C60; Serial: 004999002488244 Program: Measurement Communication System: GSM 1900; Frequency: 1880 MHz;Duty Cycle: 1:8 Medium: Head 1900 MHz (σ = 1.39 mho/m, ε r = 38.9, ρ = 1000 kg/m 3 ) Phantom section: Right Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(5.2, 5.2, 5.2); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1176; Type: SAM 4.0; Serial: 1176 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 cheek right/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 15.4 V/m Power Drift = 0.04 dB Maximum value of SAR = 0.435 mW/g cheek right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 0.708 W/kg SAR(1 g) = 0.448 mW/g; SAR(10 g) = 0.26 mW/g Reference Value = 15.4 V/m Power Drift = 0.04 dB Maximum value of SAR = 0.492 mW/g Fig. 3: SAR distribution for PCS 1900, channel 661, cheek position, right side of head. (28.07.2003; Liquid Temperature: 20.9° C; Ambient Temperature : 21.7 C). DASY Test-Report, Siemens_ 6575_330m_SAR Distribution Plots Page 6 of 17 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST; File Name: c60prm_2.da4 DUT: Siemens; Type: C60; Serial: 004999002488244 Program: Measurement Communication System: GSM 1900; Frequency: 1880 MHz;Duty Cycle: 1:8 Medium: Head 1900 MHz (σ = 1.39 mho/m, ε r = 38.9, ρ = 1000 kg/m 3 ) Phantom section: Right Section DASY4 Configuration: - Probe: …

Text truncated - open the document above for the full version.

RF Exposure Info

TTI-P-G 158 DASY Test-Report, Siemens_ 6575_330m Page 1 of 36 Report Dosimetric Assessment of the Portable Device Siemens C60 (FCC ID: PWX-C60) According to the FCC Requirements July 30, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Siemens Information & Communication Mobile LLC 16745 West Bernado Drive, Suite 400 San Diego-CA 92127 The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH DASY Test-Report, Siemens_ 6575_330m Page 2 of 36 dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH H Executive Summary The C60 is a mobile phone (Portable Device) from Siemens operating in the 900 MHz, 1800 MHz and 1900 MHz frequency range. The device has an integrated antenna. The system concepts used are the GSM 900, GSM 1800 and PCS 1900 standards including GPRS capability with 1 TX slot. The objective of the measurements done by IMST was the dosimetric assessment of one device in the PCS 1900 standard. The examinations have been carried out with the dosimetric assessment system ÑDASY4ì. The measurements were made according to the Supplement C to OET Bulletin 65 of the Federal Communications Commission (FCC) Guidelines [FCC 2001] for evaluating compliance of mobile and portable devices with FCC limits for human exposure (general population) to radiofrequency emissions. All measurements have been performed in accordance to the recommendations given by SPEAG (Fig. 13). The Siemens C60 mobile phone (FCC ID: PWX-C60) is in compliance with the Federal Communications Commission (FCC) Guidelines [FCC 2001] for uncontrolled exposure. The phone was tested in the Body Worn configuration with the following accessories and combinations with 1.5 cm distance: • GSM mode (1 TX slot) with headset • GPRS mode (1 TX slot) with datacable prepared by: ........................................... reviewed by: .............................................. Dipl.-Ing. Christoph Hennes Dr.-Ing. Frank Gustrau test engineer quality assurance engineer MST GmbH Carl-Friedrich-Gaufl-Strafle 2 D-47475 Kamp-Lintfort Tel. +49- 2842-981 373 Fax +49- 2842-981 399 email: [email protected] DASY Test-Report, Siemens_ 6575_330m Page 3 of 36 dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH H Table of Contents 1 SUBJECT OF INVESTIGATION ................................................................................................................... 4 2 THE IEEE STANDARD C95.1 AND THE FCC EXPOSURE CRITERIA................................................. 4 2.1 DISTINCTION BETWEEN EXPOSED POPULATION, DURATION OF EXPOSURE AND FREQUENCIES...................... 4 2.2 DISTINCTION BETWEEN MAXIMUM PERMISSIBLE EXPOSURE AND SAR LIMITS................................................ 5 2.3 SAR LIMIT................................................................................................................................................... 5 3 THE FCC MEASUREMENT PROCEDURE ................................................................................................ 6 3.1 GENERAL REQUIREMENTS............................................................................................................................ 6 3.2 DEVICE OPERATING NEXT TO A PERSON’S EAR............................................................................................. 6 3.3 BODY-WORN AND OTHER CONFIGURATIONS................................................................................................. 9 4 THE MEASUREMENT SYSTEM ................................................................................................................ 10 4.1 PHANTOM.................................................................................................................................................. 12 4.2 PROBE....................................................................................................................................................... 12 4.3 MEASUREMENT PROCEDURE...................................................................................................................... 13 4.4 UNCERTAINTY ASSESSMENT........................................................................................................................ 14 5 SAR RESULTS ................................................................................................................................................ 15 6 EVALUATION ................................................................................................................................................ 18 7 APPENDIX ...................................................................................................................................................... 19 7.1 ADMINISTRATIVE DATA.............................................................................................................................. 19 7.2 DEVICE UNDER TEST AND TEST CONDITIONS.............................................................................................. 19 7.3 TISSUE RECIPES......................................................................................................................................... 19 7.4 MATERIAL PARAMETERS............................................................................................................................. 20 7.5 SIMPLIFIED PERFORMANCE CHECKING...................................................................................................... 20 7.6 ENVIRONMENT........................................................................................................................................... 24 7.7 TEST EQUIPMENT....................................................................................................................................... 24 7.8 CERTIFICATES OF CONFORMITY.....................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

TTI-P-G 158 DASY Test-Report,Siemens_6575_330m_Responds Page 1 of 2 Appendix for the Report Dosimetric Assessment of the Portable Device Siemens C60 (FCC ID: PWX-C60) According to the FCC Requirements Responds to TCB request September 19, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Siemens Information & Communication Mobile LLC 16745 West Bernado Drive, Suite 400 San Diego-CA 92127 The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH DASY Test-Report,Siemens_6575_330m_Responds Page 2 of 2 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH • In the certificate from Speag concerning the uncertainty evaluation the test standard IEEE P1528-200X Draft is listed, which differs from the reference of the test report. Indeed this certificate was issued as the IEEE standard was only as Draft available. We contact Speag to issue a new certificate which listed the latest IEEE version. The expanded uncertainty (K=2) is still assessed to be ± 20.6% • For the validation of the body liquid the target values from the test report differ from the values shown in the calibration data. Indeed, the target values listed inside the report on page 20 a wrong, the right values are those inside the calibration data. If you compare the measured validation results with the target values given in the calibration data we are still within the margin. • The temperature on the validation plot differs from the temps listed in the table on page 20: Indeed, the temperature values listed on page 20 of the report for the 1900 MHz head validation a wrong. The right parameter are those listed on page 21 and inside the “SAR Plots”: Ambient Temperature: 21.6° C, Liquid Temperature: 20.9° C.

Test Report

TTI-P-G 081/94-A0 Accredited according to ISO/IEC 17025 Bluetooth Qualification Test Facility (BQTF) FCC listed # 101450 IC recognized # 3925 CETECOM Inc. 411 Dixon Landing Road Š Milpitas, CA 95035 Š U.S.A. Phone: + 1 (408) 586 6200 Š Fax: + 1 (408) 586 6299 Š E-mail: [email protected] Š http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2113686 Board of Directors: Dr. Harald Ansorge, Dr. Klaus Matkey, Hans Peter May V1.1 2003-03-01 The BLUETOOTH trademarks are owned by Bluetooth SIG, Inc., U.S.A. and licensed to CETECOM Inc. © Copyright by CETECOM FCC Test report Test report no.: EMC_530FCC-24_2003_C60 FCC Part 24 / RSS 133 FCC ID: PWX-C60 IC ID: 267E-C60 CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 2 (63) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM Inc. does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM Inc. TEST REPORT PREPARED BY: EMC Engineer: Harpreet Sidhu 1.2 Testing laboratory CETECOM Inc. 411 Dixon Landing Road, Milpitas, CA-95035, USA Phone: +1 408 586 6200 Fax: +1 408 586 6299 E-mail: [email protected] Internet: www.cetecom.com CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 3 (63) 1.3 Details of applicant Name : SIEMENS ICM Street : 16745 West Bernardo Drive City / Zip Code : San Diego CA 92127 Country : U.S.A Contact : Milton de Leon Telephone : +1 858-521-3382 Tele-fax : +1 858-521-3106 e-mail : [email protected] 1.4 Application details Date of receipt test item : 2003-08-05 Date of test : 2003-08-05/06/07/11 1.5 Test item Manufacturer : SIEMENS Street Address : Suedstr. 9 City / Zip Code : 47475 Kamp-Lintfort Country : Germany Marketing Name : C60 Model No. : C60 Description : GSM 1900 Mobile Phone FCC-ID : PWX-C60 IC ID : 267E-C60 Additional information Frequency : 1850.2MHz – 1909.8MHz for PCS 1900 Type of modulation : GMSK Number of channels : 299 for PCS 1900 Antenna : Embedded Tri-band Power supply : Battery or Charger (AC Adaptor) Output power : 32.84dBm (1.92W) maximum EIRP measured for PCS 1900 Extreme vol. Limits : 3.6VDC to 4.5VDC (nominal: 4.0VDC) Extreme temp. Tolerance : -30°C to +50°C 1.6 Test standards FCC Part 24 / RSS133 r1 CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 4 (63) 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests Performed Final Verdict: (only “passed” if all single measurements are “passed”) Passed Technical responsibility for area of testing: 2003-09-08 EMC & Radio Lothar Schmidt (Technical Manager) Date Section Name Signature Responsible for test report and project leader: 2003-09-08 EMC & Radio Harpreet Sidhu (EMC Engineer) Date Section Name Signature CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 5 (63) 2.2 Test report TEST REPORT Test report no.: EMC_530FCC-24_2003_C60 (Model: C60) CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 6 (63) TEST REPORT REFERENCE PARAMETER TO BE MEASURED PARAGRAPH PAGE POWER OUTPUT § 24.232(b) 7 FREQUENCY STABILITY § 2.1055 / § 24.235 13 OCCUPIED BANDWIDTH §2.1049(h)(i) 15 EMISSION BANDWIDTH §24.238(b) 19 EMISSIONS LIMITS §24.238 23 BAND EDGE COMPLIANCE §24.238(b) 37 RECEIVER RADIATED EMISSIONS § 15.209 49 CONDUCTED SPURIOUS EMISSIONS 54 CONDUCTED EMISSIONS § 15.107/207 59 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS 61 BLOCK DIAGRAMS 62 CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 7 (63) POWER OUTPUT § 24.232(b) Summary: During the process of testing, the EUT was controlled via Rhode & Schwarz Digital Radio Communication tester (CMD-55) to ensure max. Power transmission and proper modulation. This paragraph contains Burst Average conducted output power and EIRP measurements for the EUT. In all cases, output power is within the specified limits. Method of Measurements: The EUT was set up for the max. Output power with pseudo random data modulation. The power was measured with R&S Spectrum Analyzer ESIB 40 (peak) These measurements were done at 3 frequencies, 1850.2 MHz, 1880.0 MHz and 1909.8 MHz (bottom, middle and top of operational frequency range) CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 8 (63) Conducted: Limits: Power Step Nominal Peak Output Power (dBm) Tolerance (dB) 0 ≤30dBm (1W)* ± 2 *GSM Specification – ETSI EN 300 910 V8.5.0 (2000-07) Section 4.1 {GSM05.05 Version 8.5.0 Release 1999} Power Measurements: Conducted Average power measurements are provided by SIEMENS Please refer to attached document: FCC_C60_3 (Page 3, section 2.1, Siemens C60, “FCC Sample 4”, IMEI: 00499900248902) Frequency (MHz) Burst Average Power (dBm) 1850.2 30.3 1880.0 29.7 1909.8 28.6 CETECOM Inc. Test report no.: EMC_530FCC-24_2003_C60 Issue date: 2003-09-08 Page 9 (63) Radiated: EIRP Measurements Description: This is the test for the maximum radiated power from the EUT. Rule Part 24.232(b) specifies, "Mobile/portable stations are limited to 2 watts e.i.r.p. Peak power" and 24.232(c) specifies that "Peak transmit power must be measured over any interval of continuous transmission using instrumentation calibrated in terms of an rms-equivalent voltage." Method of Measurement: 1. In an anechoic antenna test chamber, a half-wave…

Text truncated - open the document above for the full version.

Test Setup Photos

Test setup photos C60 Test setup – Radiated Emissions Test setup photos C60 Test setup – Conducted Measurements Test setup photos C60 Test setup – AC Line Conducted Emissions

Contact Information

Applicant

Dr. Martin Weinberger(Engineering Manager)
[email protected]+49 89 722 37148Fax: +49 89 722 24799

Test Firm

Cetecom Inc.Lothar Schmidt
[email protected]408-586-6200Fax: 510-252-0559

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz1.1 W300KGXW0.0300000000 ppm
Confidentiality
Long Term
Grant Notes
This device contains 900 MHz and 1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.Power listed is EIRP. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15 mm separation between the device and the users body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest report SAR values: Head = 0.45 W/kg; Body = 0.31 W/kg.

Other Applications from BenQ Mobile GmbH & Co. OHG

Mobile Sound Set Bluetooth - FCC ID PWX-IMS100 - BenQ Mobile GmbH & Co. OHG
PWX-IMS100

Mobile Sound Set Bluetooth

Nov 09, 2006

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
GSM 900/1800/1900, UMTS Mobile Phone with BT - FCC ID PWX-SL91 - BenQ Mobile GmbH & Co. OHG
PWX-SL91

GSM 900/1800/1900, UMTS Mobile Phone with BT

Sep 13, 2006

Equipment Class

PCE - PCS Licensed Transmitter held to ear
HKW-100 CK Bluetooth Easy - FCC ID PWX-HKW100 - BenQ Mobile GmbH & Co. OHG
PWX-HKW100

HKW-100 CK Bluetooth Easy

Aug 30, 2006

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
GSM 850/1800/1900 Mobile Phone with BT - FCC ID PWX-E71A - BenQ Mobile GmbH & Co. OHG
PWX-E71A

GSM 850/1800/1900 Mobile Phone with BT

Aug 09, 2006

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
GSM 900/1800/1900 Mobile Phone with BT and FM Rece - FCC ID PWX-E71 - BenQ Mobile GmbH & Co. OHG
PWX-E71

GSM 900/1800/1900 Mobile Phone with BT and FM Rece

Aug 09, 2006

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter