Comflex NG User manual 1. System Introduction 1.1 Introduction Comba Analog DAS Solution is an industrial-leading in-building distributed antenna solution for enterprise and consumer application, supporting the wide application range of cellular generations: 4G and 5G. This solution is based on analog DAS technology with wide-band and multi-band distribution architecture, flexible off-air or wired connection mode, enabling efficient utilization of signal links. It is designed to support multi-band, multi-technology, and multi-operator networks with flexible configuration and easy commissioning. 1.2 System Architecture MU – Master Unit Select dedicated radio signal, transmit to fiber signal and then transfer to fiber Hub. It can support two kinds connectivity to radio signal: off-air connection and wired connection with different module. Fiber Hub The Fiber Hub is the central Hub and Distribution element for the analog DAS system. The fiber hub interfaces between the MU and the active antenna unit, allowing it to receive the operators service signals in optical link, and to route signals to the active antenna unit. Active Antenna Unit The active antenna unit is a low-power remote antenna unit with 19~22 dBm per MIMO stream per band 1.3 System Function 1.3.1 System features 1) Supports up to 6T6R, 4G and 5G signals 2) Output power 2.5GHz/3.5GHz: 22dBm 700MHz/850MHz/1900MHz/EAWS: 19dBm 3) Network topology ⚫ MU + Fiber HUB + ARU: 1+16+256 ⚫ MU can connect to ONE slave MU ⚫ MU can extend up to 16pcs fiber Hub ⚫ Fiber HUB can connect to 16pcs ARU ⚫ MU-HUB max fiber loss 8dBo; ⚫ HUB-ARU max fiber loss distance 45dB 4) Power Supply MU & HUB: AC 110V ARU: DC 48V 5) Couple way Off-air couple : MU - BDA Card Wired couple: MU - POI card 1.3.2 Monitoring 1) Local monitor: local debug and commission 2) Remote control: Control the system in MU site 3) System upgrade:Software upgrade in MU 4) 4G/5G demodulation: Demodulate the cellular features: RSRP, SINR, PLMN 1.4 Specification 1.4.1 Optical Specification Optical Specification Operation Frequency 600MHz-1GHz,1.7GHz-2.2GHz, 3.3GHz-4GHz Fiber Mode / Simplex Wavelength nm 1310, 1550 + WDM Optical Output MU dBm -2 – +2 HUB 6-8 Return loss dB > 45 Connector Type / SC/APC 1.4.2 Cable Specification Cable Specification Operation Frequency DC-4GHZ impedance Ω 50 VSWR / ≤1.2 Insert Loss dB ≤(L*0.48+0.2)dB@DC-4GHz @ meter 1.4.3 Radio Specification Radio Specification 700MHz 850MHz 1900MHz EAWS 2.5G band C band Frequency UL MHz 698-716 / 777-787 824-849 1850 – 1915 1710 – 1755 2496-2690 3700-3980 DL 728-746 / 746-756 869-894 1930 – 1995 2110 – 2180 IBW MHz 18/10 25 65 45/70 194 280 Carrier number (off- air card) 1 1 Carrier IBW(off-air card) MHz 194 200 Uplink Output Power (PRRU) dBm +10——+20dBm input POI card:-40 +20——+37dBm input POI card: -50 Uplink Output Power (BDA Card) dBm 19 19 19 19 22 / Downlink max output power (ARU) dBm 19 19 19 19 22 22 Downlink input range (BDA Card) dBm -95 —— -50(RSRP) -100—— -55(RSRP) Downlink input range (PRRU Card) / +10——+20dBm(RSSI) input +20——+37dBm(RSSI) input +10——+20dBm(RSSI) input +20——+37dBm(RSSI) input UL max gain (BDA Card) dB 80 80 / DL max gain (BDA Card) dB 80 80 80 UL max gain (PRRU Card) dB +10——+20dBm input: 10 +20——+37dBm input: 0 DL max gain (PRRU Card) dB +10——+20dBm input: 10 +20——+37dBm input: 0 ATT adjust range dB MU: 0 – 30, ARU: 0 – 20 In-band ripple(P-P) dB ≤ 4 ≤ 6 ≤ 6 ≤ 6 ≤ 6 ≤ 6 Emission spur FCC FCC FCC FCC FCC FCC UL NF at max gain dB ≤ 10 System delay (BDA Card) usec ≤ 10 System delay (PRRU Card) usec ≤ 3 Input VSWR ≤ 1.5 MU Max input power (BDA Card) dBm -10 MU Max input power (PRRU Card) dBm 37 ARU Max input RF power dBm -10 1.5 INSTALLATION 1.6 WARNINGS AND ALERTS Laser Laser light can cause damage to eyes. Laser light is not visible. Viewing it directly does not cause pain. The iris of the eye will not close when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. NEVER LOOK INTO THE END OF A FIBER WHICH MAY HAVE A LASER COUPLED TO IT. Radio Frequency Energies There may be situations, particularly for workplace environments near high-powered RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe use of RF energy. High Voltage The equipment has been designed and constructed to prevent practicable danger, as far as reasonably possible. Any work activity on or near equipment involving installation, operation or maintenance must be free from danger, as far as reasonably possible. Where there is a risk of damage to electrical systems involving adverse weather, extreme temperatures, wet, corrosive or dirty conditions, flammable or explosive atmospheres, the system must be suitably installed to prevent danger. Protective Earthing Equipment provided for the purpose of protecting individuals from electrical risk must be suitable for the purpose and properly maintained and used. Handling Precautions This covers a range of activities including lifting, lowering, pushing, pulling, carrying, moving, holding or restraining an object or person. It also covers activities that require the use of force or effort, such as pulling a lever, or operating power tools. Electrostatic Discharge (ESD) Observe standard precautions for handling ESD-sensitive devices. Assume that all solid-state electronic devices are ESD-sensitive. Ensure the use of a grounded wrist strap or equivalent while working with ESD-sensitive devices. Transport, store, and handle ESD-sensitive devices in static-safe environments. WARNING This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. The device not …
Text truncated - open the document above for the full version.
Applicant Declaration QSF27-14-04 Rev 1.0 Rev. Feb 6, 2023 Page 1 of 2 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Comba Telecom Network Systems Limited Address Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok HongKong, 510663, China Grantee Code PX8 FCC ID PX8CFNG-MU Authorized Contact Name Ronin Gong Contact Email [email protected] Contact Phone +86 2028390000 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Comba Telecom Network Systems Limited (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Comba Telecom Network Systems Limited (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. Applicant Signature: Date: 4/20/2023 Print Name: Ronin Gong Title: Director *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration QSF27-14-04 Rev 1.0 Rev. Feb 6, 2023 Page 2 of 2 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States
Comba Telecom Network Systems Limited Attestation To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Comba Telecom Network Systems Limited Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok HongKong, 510663, China For FCC ID:PX8CFNG-MU; Model number: Comflex NG MU We Comba Telecom Network Systems Limited declare that warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device. WARNING! This i s NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Name (Printed): Ronin GongTitle: Director Signature: On behalf of Company: Comba Telecom Network Systems Limited
Comba Telecom Network Systems Limited Authority letter FCC Date: 4/20/2023 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: PX8CFNG-MU To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Bonnie Liao in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Comba Telecom Network Systems Limited. This authorization is valid until further written notice from the applicant. Name (Printed): Ronin Gong Title: Director Signature: On behalf of Company: Comba Telecom Network Systems Limited
Comba Telecom Network Systems Limited Confidential letter FCC To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Comba Telecom Network Systems Limited Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok HongKong, 510663, China Regarding: Confidentiality Request regarding application for FCC ID: PX8CFNG-MU LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune up The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Name (Printed): Ronin Gong Title: Director Signature: On behalf of Company: Comba Telecom Network Systems Limited
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 4 FCC ID: PX8CFNG-MU Appendix - External Photos for GZCR2303000224AT Test Model No.: Comflex NG MU SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 2 of 4 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 4 of 4 - End of the Appendix -
Device FCC 1 Warming 53.00 35 . 00 Comba Telecom Ltd. Made in China Comflex NG MU ERP#: 780400-000115-0000 P/N: Comflex NG MU S /N: 60.00 30 . 00 FCC ID :PX8CFNG-MU WARNING ! ACCORDIN G TO PART 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the follow ing two conditions: (1) this devi ce may not cause harmful interfere nce, and (2) this devi ce must accept any interference receive d, including interference that may cause undesired operation. WARNING ACCORDING TO PART 20 This is NOT a CONSUMER de vice. It i s designed for install ation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this de vice. Unauthori zed use may re sult in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. 90.00 30 . 00
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 9 FCC ID: PX8CFNG-MU Appendix - Internal Photos for GZCR2303000224AT Test Model No.: Comflex NG MU SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 2 of 9 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 3 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 4 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 5 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 6 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 7 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 8 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-01 Rev 1.1 Page: 9 of 9 - End of the Appendix -
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 1 of 11 FCC ID: PX8CFNG-MU Ricky Liu Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2303000224AT Applicant: Comba Telecom Network Systems Limited Address of Applicant: Flat/Rm 10, 3/F, Bio-Informatics Ctr, 2 Science Park West Avenue, HK Science Park, Pak Shek Kok, N.T. Hong Kong Manufacturer: Comba Network Systems Company Limited Address of Manufacturer: No. 10 Shenzhou Road, Guangzhou Science City, Guangzhou 510663, Guangdong, P.R.China Factory: Comba Telecom Technology (Guangzhou) Ltd. Address of Factory: No. 6 Jinbi Road, Economics and Technology Development District, Guangzhou, Guangdong, China Equipment Under Test (EUT): EUT Name: Comflex NG Model No.: Comflex NG MU Trade Mark: Comba Standard(s) : 47 CFR Part 2.1091 47 CFR Part 1.1310, Part 1.1307 Date of Receipt: 2023-03-02 Date of Evaluation: 2023-04-17 Date of Issue: 2023-04-28 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 2 of 11 Revision Record VersionChapterDateModifier Remark 01GZCR2303000224082023-04-28Original Authorized for issue by: Kevin Zhang /Project Engineer Jerry Chan /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 3 of 11 2Evaluation Summary Radio Spectrum Technical Requirement ItemStandardRequirementMethodResult RF Exposure 47 CFR Part 2.1091 47 CFR Part 1.1310 47 CFR Part 1.1307 47 CFR Part 1.131047 CFR Part 1.1310PASS SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 4 of 11 3Contents Page 1 Covers Page................................................................................................................................................1 2Evaluation Summary..................................................................................................................................3 3Contents......................................................................................................................................................4 4General Information....................................................................................................................................5 4.1Details of E.U.T...............................................................................................................................................5 4.2Evaluated Location........................................................................................................................................6 4.3Test Facility......................................................................................................................................................6 4.4Deviation from Standards............................................................................................................................7 4.5Abnormalities from Standard Conditions................................................................................................7 5Radio Spectrum Technical Requirement..................................................................................................8 5.1RF Exposure....................................................................................................................................................8 5.1.1Requirement.................................................................................................................................................8 5.1.2Method...........................................................................................................................................................9 5.1.3Conclusion....................................................................................................................................................9 5.2EUT Constructional Details (EUT Photos).............................................................................................11 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 5 of 11 4General Information 4.1Details of E.U.T. Power Supply:AC 100-240V, 50/60Hz Test Voltage: AC 110V Cable:AC mains (2m, unshielded) Operating Temperature:-40 to +55 °C Operating Humidity:≤95% Lower 700MHz: Uplink: 698-716MHz Downlink: 728-746MHz Upper 700MHz: Uplink: 777-787MHz Downlink: 746-756MHz Cellular: Uplink: 824-849MHz Downlink: 869-894MHz EAWS: Uplink: 1710-1755MHz Downlink: 2110-2180MHz Broadband PCS: Uplink: 1850-1915MHz Downlink: 1930-1995MHz BRS/EBS: Uplink: 2496-2690MHz Downlink: 2496-2690MHz Frequency Range: 3.7GHz service*: Uplink: 3700-3980MHz Downlink: 3700-3980MHz LTE Support Technology: 5G NR Modulation Type:PSK/QPSK/QAM/16QAM/64QAM/256QAM BDA Card Port4.3-10-Female POI Card port4.3-10-Female Interface: Debug PortRJ-45 Lower 700MHz:19dBm Upper 700MHz:19dBm Cellular:19dBm EAWS:19dBm Broadband PCS:19dBm Normal Output Power: (per antenna port, uplink, BDA card) BRS/EBS:22dBm Normal System Gain:uplink & downlink: 80dB (BDA card) EUT Configuration:1T1R SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR230300022408 Page: 6 of 11 Antenna Type: External Dedicated Antenna Permission Antenna Gain:14dBi or less (declared by the manufacturer) Software Version: ChassisOAMV0100.01 Note: *: 3.7GHz service band can only operate on POI card, which connects directly to a base station via coaxial cable but cannot connect to antenna and/or amplifier. 4.2Evaluated Location All evaluation were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 1 of 29 FCC ID: PX8CFNG-MU Appendix - Test Data and Result for report GZCR230300022402 (Lower 700MHz band) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 2 of 29 1 Out-of-band rejection Out-of-band rejection Uplink The peak of the frequency response f0 is 707.5MHz. The frequency point f0 with the highest power level fall in the CMRS band under test, EUT is compiled the 935210 D05 Indus Booster Basic Meas v01r04 Out- of-band rejection verification test requirement. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 3 of 29 2 Input versus Output comparison Occupied Bandwidth Test Path Test Signal Test Channel Signal Level Verdict Uplink 5MHz AWGN Middle Channel Pre-AGC PASS 3dB above AGC PASS 100MHz AWGN Middle Channel Pre-AGC PASS* 3dB above AGC PASS* GSM Middle Channel Pre-AGC PASS 3dB above AGC PASS Remark: *: The Lower 700MHz band supports maximum channel BW is 15MHz @ NR, so the output OBW was less than the input when 100MHz AWGN was as stimulus signal. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 4 of 29 99% OBW Uplink_5MHz AWGN_Middle Channel_Input pre-AGC Uplink_5MHz AWGN_Middle Channel_Input 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 5 of 29 99% OBW Uplink_5MHz AWGN_Middle Channel_Output pre-AGC Uplink_5MHz AWGN_Middle Channel_Output 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 6 of 29 99% OBW Uplink_100MHz AWGN_Middle Channel_Input pre-AGC Uplink_100MHz AWGN_Middle Channel_Input 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 7 of 29 99% OBW Uplink_100MHz AWGN_Middle Channel_Output pre-AGC Uplink_100MHz AWGN_Middle Channel_Output 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 8 of 29 99% OBW Uplink_GSM_Middle Channel_Input pre-AGC Uplink_GSM_Middle Channel_Input 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 9 of 29 99% OBW Uplink_GSM_Middle Channel_Output pre-AGC Uplink_GSM_Middle Channel_Output 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 10 of 29 3 Mean output power and amplifier/booster gain Mean output power and gain Test Path Test Freq. f0 (MHz) Test Signal Signal Level Input power (dBm) Output Power (dBm) ERP (W) Gain (dB) Uplink 707.5 5MHz AWGN Pre-AGC -61.00 19.85 1.479 80.85 3dB above AGC -58.00 19.91 1.500 / 100MHz AWGN Pre-AGC -61.00 14.87 0.470 75.87 3dB above AGC -58.00 14.02 0.386 / GSM Pre-AGC -61.00 20.16 1.589 81.16 3dB above AGC -58.00 19.89 1.493 / Remark: 1. f0 is from Out-of-band Rejection test in the report. 2. ERP= output power (dBm)+ antenna gain (dBi)- 2.15dB, the max antenna gain is 14dBi declared by the manufacturer. Mean output power Test Path Test Freq. f0 (MHz) Test Signal Signal Level Output Power (dBm/MHz) ERP (W/MHz) Verdict Uplink 707.5 5MHz AWGN Pre-AGC 12.64 0.281 PASS 3dB above AGC 12.97 0.303 PASS 100MHz AWGN Pre-AGC 4.21 0.040 PASS 3dB above AGC 4.05 0.039 PASS GSM Pre-AGC 20.11 1.570 PASS 3dB above AGC 20.04 1.545 PASS Remark: 1. f0 is from Out-of-band Rejection test in the report. 2. ERP= output power (dBm)+ antenna gain (dBi)- 2.15dB, the max antenna gain is 14dBi declared by the manufacturer. 3. The output power is limited to an ERP of 1000W/MHz. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 11 of 29 4 Out-of-band/out-of-block (including intermodulation) emissions Out-of-band/out-of-block(including intermodulation) emissions Test Path Test Channel Test Signal Stimulus Condition Signal Level Worst conducted test level (dBm) Limit (dBm) Verdict Uplink lower edge 5MHz AWGN One signal input Pre-AGC -33.25 ≤-13 PASS 3dB above AGC -33.59 PASS Two signals input Pre-AGC -32.49 PASS 3dB above AGC -32.29 PASS upper edge One signal input Pre-AGC -31.42 PASS 3dB above AGC -30.71 PASS Two signals input Pre-AGC -31.38 PASS 3dB above AGC -31.60 PASS Remark: The power of any emission outside a licensee’s frequency block shall be attenuated below the transmitter power (P) in watts by at least 43 + 10log10 (P) dB, P = 19dBm = 0.08W, so the limit = 19dBm – [43 + 10 log10 (0.08W)] dB = -13dBm Out-of-band/out-of-block(including intermodulation) emissions Test Path Test Channel Test Signal Stimulus Condition Signal Level Worst conducted test level (dBm) Limit (dBm) Verdict Uplink lower edge 100MHz AWGN One signal input Pre-AGC -42.57 ≤-13 PASS 3dB above AGC -42.16 PASS Two signals input Pre-AGC -43.34 PASS 3dB above AGC -44.03 PASS upper edge One signal input Pre-AGC -43.63 PASS 3dB above AGC -43.91 PASS Two signals input Pre-AGC -42.79 PASS 3dB above AGC -42.42 PASS Remark: The power of any emission outside a licensee’s frequency block shall be attenuated below the transmitter power (P) in watts by at least 43 + 10log10 (P) dB, P = 19dBm = 0.08W, so the limit = 19dBm – [43 + 10 log10 (0.08W)] dB = -13dBm SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 12 of 29 Out-of-band/out-of-block(including intermodulation) emissions Test Path Test Channel Test Signal Stimulus Condition Signal Level Worst conducted test level (dBm) Limit (dBm) Verdict Uplink lower edge GSM One signal input Pre-AGC -26.67 ≤-13 PASS 3dB above AGC -27.02 PASS Two signals input Pre-AGC -27.44 PASS 3dB above AGC -27.78 PASS upper edge One signal input Pre-AGC -27.89 PASS 3dB above AGC -28.37 PASS Two signals input Pre-AGC -29.68 PASS 3dB above AGC -29.29 PASS Remark: The power of any emission outside a licensee’s frequency block shall be attenuated below the transmitter power (P) in watts by at least 43 + 10log10 (P) dB, P = 19dBm = 0.08W, so the limit = 19dBm – [43 + 10 log10 (0.08W)] dB = -13dBm SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 13 of 29 Out-of-band/out-of-block emissions Uplink_5MHz AWGN_One signal input_Pre-AGC_Lower edge Uplink_5MHz A…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 1 of 29 FCC ID: PX8CFNG-MU Appendix - Test Data and Result for report GZCR230300022403 (Upper 700MHz band) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 2 of 29 1 Out-of-band rejection Out-of-band rejection Uplink The peak of the frequency response f0 is 781.5MHz. The frequency point f0 with the highest power level fall in the CMRS band under test, EUT is compiled the 935210 D05 Indus Booster Basic Meas v01r04 Out-of-band rejection verification test requirement. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 3 of 29 2 Input versus Output comparison Occupied Bandwidth Test Path Test Signal Test Channel Signal Level Verdict Uplink 5MHz AWGN Middle Channel Pre-AGC PASS 3dB above AGC PASS 100MHz AWGN Middle Channel Pre-AGC PASS* 3dB above AGC PASS* GSM Middle Channel Pre-AGC PASS 3dB above AGC PASS Remark: *: The Upper 700MHz band supports maximum channel BW is 10MHz @ NR, so the output OBW was less than the input when 100MHz AWGN was as stimulus signal. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 4 of 29 99% OBW Uplink_5MHz AWGN_Middle Channel_Input pre-AGC Uplink_5MHz AWGN_Middle Channel_Input 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 5 of 29 99% OBW Uplink_5MHz AWGN_Middle Channel_Output pre-AGC Uplink_5MHz AWGN_Middle Channel_Output 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 6 of 29 99% OBW Uplink_100MHz AWGN_Middle Channel_Input pre-AGC Uplink_100MHz AWGN_Middle Channel_Input 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 7 of 29 99% OBW Uplink_100MHz AWGN_Middle Channel_Output pre-AGC Uplink_100MHz AWGN_Middle Channel_Output 3dB above AGC SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Page: 8 of 29 99% OBW Uplink_GSM_Middle Channel_Input pre-AGC Uplink_GSM_Middle Channel_Input 3dB above AGC SGS-CSTC Standards…
Text truncated - open the document above for the full version.
No.198 Kezhu Road, Science City Economic & · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 12 | 27 | 2.50 GHz - 2.69 GHz | 234.00 mW | W7D | Amp |

SailaJoint
Equipment Class
DTS - Digital Transmission System
Public Safety UHF and VHF Dualband Bi-Directional Amplifier
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)
Multi internal Remote Control Unit
Equipment Class
JAB - Part 15 Class B Digital Device
700MHz/800MHz Public Safety Bi-directional Amplifier
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
700MHz/800MHz Public Safety Bi-directional Amplifier
Equipment Class
B9A - Part 90 Class A Industrial Booster (non-SMR)