Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 19 of 34 6 Annex B: Photographs of Test site Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 20 of 34 Photo 2 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 21 of 34 Photo 3 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 22 of 34 Photo 4 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 23 of 34 Photo 5 (Conducted Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 24 of 34 7 Annex C: External Photographs of the Equipment Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 25 of 34 Photo 2 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 26 of 34 Annex D: Internal Photographs of the Equipment Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 27 of 34 Photo 2 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 28 of 34 Photo 3 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 29 of 34 Photo 4 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 30 of 34 Photo 5 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 31 of 34 Photo 6 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 32 of 34 Photo 7 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 33 of 34 Photo 8 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 34 of 34 Photo 9
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 19 of 34 6 Annex B: Photographs of Test site Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 20 of 34 Photo 2 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 21 of 34 Photo 3 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 22 of 34 Photo 4 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 23 of 34 Photo 5 (Conducted Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 24 of 34 7 Annex C: External Photographs of the Equipment Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 25 of 34 Photo 2 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 26 of 34 Annex D: Internal Photographs of the Equipment Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 27 of 34 Photo 2 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 28 of 34 Photo 3 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 29 of 34 Photo 4 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 30 of 34 Photo 5 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 31 of 34 Photo 6 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 32 of 34 Photo 7 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 33 of 34 Photo 8 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 34 of 34 Photo 9
Company Internal REPORT 1 (11) Prepared (also subject responsible if other) No. LD/SEMC/BGGI/NM Hamid Kami Shirazi BGGIN06:023 Approved Checked Date Rev Reference LD/SEMC/BGGI/NM Ramadan Plicanic 060202 060126 A File Report issued by Accredited SAR Laboratory For PY7A1042021 (J100a) Date of test: 17 to 20, Jan, 2006 Laboratory: Sony Ericsson SAR Test Laboratory Sonyericsson Mobile Communications AB Nya Vattentornet SE-221 82 LUND, Sweden Testing Engineer: Hamid Kami Shirazi [email protected] +46 46232644 Testing Approval Ramadan Plicanic [email protected] +46 46 19 38 62 Statement of Compliance Sony Ericsson Mobile Communications AB declares under its sole responsibility that the product Sony Ericsson Type AAA-1042021-BV; FCC ID: PY7A1042021; IC:4170B-A1042021 to which this declaration relates, is in conformity with the appropriate RF exposure standards recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (None) This laboratory is accredited to ISO/IEC 17025 (SWEDAC accreditation no. 1847). Laboratories are accredited by the Swedish Board for Accreditation and Conformity Assessment (SWEDAC) under the terms of Swedish legislation. The accredited laboratory activities meet the requirements in SS-EN ISO/IEC 17025 (2000). This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Sony Ericsson encourages all feedback, both positive and negative, on this report. © Sony Ericsson Mobile Communication AB, 2006 Company Internal REPORT 2 (11) Prepared (also subject responsible if other) No. LD/SEMC/BGGI/NM Hamid Kami Shirazi BGGIN06:023 Approved Checked Date Rev Reference LD/SEMC/BGGI/NM Ramadan Plicanic 060202 060126 A File 1 Table of contents 2 INTRODUCTION..................................................................................................................................................................3 3 DEVICE UNDER TEST........................................................................................................................................................3 3.1 A NTENNA DESCRIPTION.......................................................................................................................................................3 3.2 D EVICE DESCRIPTION...........................................................................................................................................................3 4 TEST EQUIPMENT ..............................................................................................................................................................4 4.1 D OSIMETRIC SYSTEM............................................................................................................................................................4 4.2 A DDITIONAL EQUIPMENT.....................................................................................................................................................4 5 ELECTRICAL PARAMETERS ON THE TISSUE SIMULATING LIQUID ..............................................................4 6 SYSTEM ACCURACY VERIFICATION..........................................................................................................................5 7 SAR MEASUREMENT UNCERTAINTY .........................................................................................................................6 8 TEST RESULTS ....................................................................................................................................................................7 9 REFERENCES .......................................................................................................................................................................8 10 APPENDIX .............................................................................................................................................................................9 10.1 P HOTOGRAPHS OF THE DEVICE UNDER TEST....................................................................................................................9 10.2 D EVICE POSITION ON SAM TWINS PHANTOM...............................................................................................................11 10.3 A TTACHMENTS...............................................................................................................................................................12 Company Internal REPORT 3 (11) Prepared (also subject responsible if other) No. LD/SEMC/BGGI/NM Hamid Kami Shirazi BGGIN06:023 Approved Checked Date Rev Reference LD/SEMC/BGGI/NM Ramadan Plicanic 060202 060126 A File 2 Introduction In this test report, compliance of the Sony Ericsson PY7A1042021 (J100a) portable telephone with RF safety guidelines is demonstrated. The applicable RF safety guidelines and the SAR measurement specifications used for the test are described in the SAR Measurement Specifications of Wireless Handsets [1]. 3 Device under Test 3.1 Antenna Description Type Internal antenna Location Inside, Back, at the Top Max length 38mm Dimensions Max width 16mm Configuration PIFA 3.2 Device description Device model PY7A1042021(J100a) Serial number 108939932 Mode GSM 850 GSM1900 Crest Factor 8 8 Multiple Access Scheme TDMA TDMA Ch128 Ch190 Ch251 Ch512 Ch661 Ch810 Maximum Output Power Setting dBm 32.3 32.3 32.3 29.4 29.4 29.4 Factory Tolerance in Power Setting ±0.5dB ±0.5dB Maximum Peak Output Power dBm 32.8 32.8 32.8 29.9 29.9 29.9 Transmitting Frequency Range(MHz) 824.2-848.8 1850.2 – 1909.8 Prototype…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4094-19-02/05 Date: 2006-01-27 Page 1 of 80 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Test report No. : 2-4094-19-02/05 Applicant : Sony Ericsson Mobile Communications AB Type : AAA-1042021-BV Test Standard : FCC Part 22, 24 RSS132, 133 FCC ID : PY7A1042021 Certification No. IC : 4170B-A1042021 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report No.: 2-4094-19-02/05 Date: 2006-01-27 Page 2 of 80 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT......................................................................................................................................... 4 1.4 APPLICATION DETAILS.......................................................................................................................................... 4 1.5 TEST ITEM............................................................................................................................................................. 5 1.6 TEST SETUP........................................................................................................................................................... 6 1.7 TEST STANDARDS.................................................................................................................................................. 6 2 STATEMENT OF COMPLIANCE .......................................................................................................................... 7 2.1 SUMMARY OF MEASUREMENT RESULTS................................................................................................................ 7 2.1.1 PCS 1900 ...................................................................................................................................................... 7 2.1.2 GSM 850 ....................................................................................................................................................... 7 3 MEASUREMENTS AND RESULTS ....................................................................................................................... 8 3.1 PART PCS 1900 ................................................................................................................................................... 8 3.1.1 RF Power Output .......................................................................................................................................... 8 3.1.2 Frequency Stability..................................................................................................................................... 12 3.1.3 Radiated Emissions..................................................................................................................................... 15 3.1.4 Receiver Radiated Emissions ...................................................................................................................... 25 3.1.6 Block Edge Compliance .............................................................................................................................. 33 3.1.7 Occupied Bandwidth................................................................................................................................... 36 3.2 PART GSM 850 .................................................................................................................................................. 43 3.2.1 RF Power Output ........................................................................................................................................ 43 3.2.2 Frequency Stability..................................................................................................................................... 46 3.2.3 Radiated Emissions..................................................................................................................................... 48 3.2.4 Receiver Radiated Emissions ...................................................................................................................... 59 3.2.5 Conducted Spurious Emissions ................................................................................................................... 63 3.2.6 Block Edge Compliance .............................................................................................................................. 67 4 USED TESTEQUIPMENT ...................................................................................................................................... 77 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report No.: 2-4094-19-02/05 Date: 2006-01-27 Page 3 of 80 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing …
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 1 of 34 \\ut55\2_PROJEKTE\05\4094_19\Task2(MCP)\Erg\Annex to 2-4094-19-02_05 Lisa 850.doc Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Annex to Test report no. : 2-4094-19-02/05 Applicant : Sony Ericsson Mobile Communications AB Test Standard : FCC Part 15 / RSS210 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 2 of 34 Table of contents 1 GENERAL INFORMATION ......................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY........................................................................................................... 3 1.1.1 Identification of the testing laboratory ............................................................................................................... 3 1.2. NOTES......................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT............................................................................................................................................... 4 1.4 APPLICATION DETAILS................................................................................................................................................ 4 1.5 TEST SET-UP DESCRIPTION.......................................................................................................................................... 5 1.6 TEST SPECIFICATIONS.................................................................................................................................................. 5 2 STATEMENT OF COMPLIANCE ................................................................................................................................ 6 2.1 SUMMARY OF MEASUREMENT RESULTS...................................................................................................................... 6 2.1.1 CFR 47 Part 15 Radio frequency devices ........................................................................................................... 6 3 MEASUREMENTS AND RESULTS ............................................................................................................................. 7 4 ANNEX A: FCC PART 15 SUBPART B........................................................................................................................ 8 4.1 CONDUCTED LIMITS.................................................................................................................................................... 8 4.2 RECEIVER SPURIOUS EMISSION RADIATED (IDLE MODE) ............................................................................................ 11 5 USED TESTEQUIPMENT ............................................................................................................................................ 16 6 ANNEX B: PHOTOGRAPHS OF TEST SITE ........................................................................................................... 19 7 ANNEX C: EXTERNAL PHOTOGRAPHS OF THE EQUIPMENT....................................................................... 24 8 ANNEX D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT........................................................................ 34 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 3 of 34 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing laboratory Company name: Cetecom ICT Services GmbH Address: Untertürkheimerstr. 6-10 D-66117 Saarbruecken Germany Laboratory accreditation: DAR-Registration No. DAT-P-176/94-D1 Bluetooth Qualification Test Facility (BQTF) Federal Communications Commission (FCC) Identification/Registration No : 90462 Responsible for testing laboratory: D. Hausknecht Phone: +49 681 598 0 Fax: +49 681 598 9075 email: [email protected] 1.2. Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. ..................................................................................... Responsible for test and test report (D. Gillmann) ..................................................................................... Responsible for testing laboratory (D. Hausknecht) CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Annex to Test report no.: 2-4094-19-02/05 Date: 2006-01-26 Page 4 of 34 1.3 Details of Applicant Name : Sony Ericsson Mobile Communications AB Address : Vya Vattentornet City : S-22188 Lund Country : Sweden Phone : + 46 (0) 705757 380 Fax : + 46 (0) 46 19 32 95 Contact…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 22H | 824.2 MHz - 848.8 MHz | 776.00 mW | 300KGXW | 0.0306 ppm |
GSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS
Equipment Class
NII - Unlicensed National Information Infrastructure TXGSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterGSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS
Equipment Class
PCE - PCS Licensed Transmitter held to earGSM/WCDMA/LTE/NR Phone with BT, DTS/UNII a/b/g/n/ac/ax/be, NFC, GNSS and WPT
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterGSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac, NFC and GNSS
Equipment Class
PCE - PCS Licensed Transmitter held to ear