FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sony Corporation/
  3. PY7A3880071

PY7A3880071GSM 850/900/1800/1900 GPRS / EDGE / UMTS FDD 125 / HSPA mobile phone with Bluetooth, WLAN 802.11bg, GPS, FM receiver

Sony Corporation
GSM 850/900/1800/1900 GPRS / EDGE / UMTS FDD 125 / HSPA mobile phone with Bluetooth, WLAN 802.11bg, GPS, FM receiver - FCC ID PY7A3880071 - Sony Corporation
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jun 10, 2010
Application Purpose
Original Equipment
Date of Application
Jun 10, 2010
Equipment Note
GSM 850/900/1800/1900 GPRS / EDGE / UMTS FDD 125 / HSPA mobile phone with Bluetooth, WLAN 802.11bg, GPS, FM receiver
Frequency Range
1852.40000000 - 1907.60000000
Company
Sony Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

X10 mini pro User guide Important information Please read the Important information leaflet before you use your mobile phone. Some of the services and features described in this User guide are not supported in all countries/regions or by all networks and/or service providers in all areas. Without limitation, this applies to the GSM International Emergency Number 112. Please contact your network operator or service provider to determine availability of any specific service or feature and whether additional access or usage fees apply. Experience more. Discover how. Need help? Get more, do more. Miss nothing. Visit www.sonyericsson.com/xperiax10minipro to learn more about your phone. User guide in the phone An extended User guide is available in your phone. The extended User guide and more information is also available at www.sonyericsson.com/support. To access the User guide in your phone 1 From the Home screen, drag upwards. 2 Find and tap User guide . 2 Getting started To insert the SIM card and the memory card 2 1 1 Remove the battery cover. 2 Slide the SIM card with the gold-coloured contacts facing down and memory card with the gold-coloured contacts facing up. To insert the battery 1 2 3 1 Insert the battery with the label side up and the connectors facing each other. 2 Attach the battery cover. To turn on the phone 1 Press and hold down the key on the top of the phone. 2 Enter your SIM card PIN, if requested, and select OK. 3 At first startup, follow the instructions in Setup guide. Your PIN is supplied by your network operator. If you want to correct a mistake made while entering your SIM card PIN, press . To turn off the phone 1 Press and hold until the options menu opens. 2 In the options menu, tap Power off. 3 Tap OK. To activate the screen • Press . To lock the screen • Press . Starting your phone for the first time The first time you start your phone, a setup guide lets you enter essential phone settings, import contacts, and set up your email and online services accounts. You can also access the setup guide later from the phone settings. To set the language 1 Scroll through the available languages list. 2 Tap the language you want to use in your phone. The language is marked. 4 3 Tap Save. Internet and messaging settings In order to send messages and use the Internet you will need a 2G/3G mobile data connection. For most mobile phone networks and operators, settings for messaging and the Internet will be preinstalled on the phone or downloaded to your phone the first time you turn on the phone with a SIM card inserted. If not, you can go to www.sonyericsson.com/support from your computer to download the settings to your phone. To import contacts from the SIM card 1 From the setup guide, tap Import contacts. 2 When you are asked to confirm if you want to import the contacts from the SIM card to the phone, tap Yes. By using Sony Ericsson Sync you can synchronise contacts, bookmarks and calendar events between your phone and your Sony Ericsson account. This way you can transfer information from your old phone to the Sony Ericsson account, and then transfer it to your new phone. You can set up a Sony Ericsson account from the Sony Ericsson Sync application in your phone, or by going to www.sonyericsson.com/user from your computer. To set the time and date 1 From the setup guide, tap Time & date. 2 Unmark the Automatic checkbox, if it is marked. 3 Tap Set date or Set time. 4 Tap or to adjust the date or hour and minute. 5 5 Tap Set. While setting time, you can shift between 12-hour and 24-hour format. If you want to use AM and PM, you have to unmark Use 24-hour format. To create a new Google™ account in your phone 1 From the setup guide, tap Google account. 2 Tap Next. 3 Tap Create. 4 Enter your personal information and desired Google™ username. Tap Next. 5 Enter and confirm your password. Tap Next. 6 Select a security question and enter a personal answer that only you know. You can also enter a secondary email address to which your Google™ account information could be sent in case you forget the information. Tap Next. 7 To agree to the Google™ Terms of service, tap I agree, Next. 8 Enter the security word displayed as an image. Tap Next. 9 Mark the checkboxes to allow the additional Google™ services, or leave them blank if you do not agree to use these services. Tap Next. 10 Tap Finish setup. Your new Google™ account has now been created and set up to be used with the Google™ services in your phone. To set up an existing Google™ account in your phone 1 From the setup guide, tap Google account. 2 Tap Next. 3 Tap Sign in. 6 4 Enter your Google™ username and password. Tap Sign in to continue. 5 Mark the checkboxes to allow the additional Google™ services, or leave them blank if you do not agree to use these services. Tap Next. 6 Tap Finish setup. Your Google™ account has now been set up in your phone. In most cases, your Google™ username is the first part of your Google™ email address. To set up an email account 1 From the setup guide, tap Email. 2 Tap Email address, enter your email address and tap Next. 3 Enter your password and tap Done. 4 Tap Continue. 5 If the phone cannot download your email account settings automatically, enter the account settings manually. If you need to enter the settings manually, contact your email service provider for the correct email account settings. For example, you need to know if the account type is POP3 or IMAP. Sony Ericsson Timescape™ settings Sony Ericsson Timescape™ collects all the communication events at one place and keeps you updated with messages, missed calls from your contacts and friends in Facebook™ and Twitter™. To set up a Facebook™ account 1 From the setup guide, tap Facebook. 2 Tap Username, enter your username and tap Next. 7 3 Enter your password and tap Done. To set up a Twitter™ account 1 From the setup guide, tap Twitter. 2 Tap Username, enter your username and tap Next. 3 Enter your password and tap Done. To exit the setup …

Text truncated - open the document above for the full version.

Cover Letter(s)

Sony Ericsson Confidentiality Request 2010-05-31 CWA10:237 SEMC/CWALG Afrah Sadiq +46 108012250 Receiver Federal Communications Commission Subject: Request for Confidentiality FCC 10: PY7A3880071 To Whom It May Concern: In accordance with §0.459 of CFR 47, Sony Ericsson Mobile Communications AB requests confidentiality for the below listed items for our mobile phone type AAD­ 3880071-BV, FCC 10: PY7A3880071: 1. Block Diagram 2. Schematic Diagram 3. Part List 4. Operational/Technical Descriptions These items contain detailed system and equipment description and related information about the product which Sony Ericsson Mobile Communications AB considers to be proprietary, confidential and a custom design which otherwise would not be released to the general public. Since this design is a basis from which future technological products will evolve, Sony Ericsson Mobile Communications AB also feels that this information would be of benefit to its competitors, and that the disclosure of the information in these exhibits would give our competitors an unfair advantage in the market. Please contact the undersigned if there are any further questions or additional information needed in this matter. Best Regards, Afrah Sadiq Development Engineer - Global Type Approval Sony Ericsson Mobile Communications AB Sony Ericsson Mobile Communications AS Styrelsens sate: Lund Momsnr· \l.A. T.No: SE556615665801 Registered office: Lund Organisationsnr· Reg No: 556615-6658 Postadress • Mail Bes6ksadress • Office address Telefon • Telephone Telefax • Telefax SE-221 88 Lund Nya Vallentornet Nat 010-80 00000 Nat 010-80 02040 Sweden Lund Int +46 10 80 00000 Int +46 10 80 02040

External Photos

CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 20 of 33 9 Photographs of t he E UT Photo documentation: external photos Photo 1: Photo 2: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 21 of 33 Photo 3: Photo 4: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 22 of 33 Photo 5: Photo 6: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 23 of 33 Photo 7:

ID Label/Location Info

1 ( 4) Company Internal MARKING DRAWIN G Prepared (also subject responsible if other) No. SEM/CVVGP, Anna Englund 1238-3476 Uen Approved Checked Date Rev Reference SEM/CVVGP, Anna Englund 2010-05-04 2 15 U20a, Mobile Phone label content, a-version, Made in... 1 General information Mobile Phone label part no  1232-1232 Mobile Phone label content part no  1238-3475 Bar code  Print quality: according to COSMETIC GUIDELINE – Bar code labels document 1222-6072 Uen  Quiet zone: No bar codes are allowed to be closer to a label edge than 2 mm! Text If applicable, or nothing else specified, Zebra printer Scaleable Smooth Font CG Triumvirate Bold Condensed is imposed. When needed, the text is adjusted to fit the label. Coordinates “(x/y)” under each line number specifies the bottom / left alignment for text, graphics and bar codes, x is measured vertically, and y horizontally from the upper left corner of the label (landscape format), both in mm. When needed, the alignment is adjusted to fit the label. 2 Printing information Content Format Line 1 (6,5/30,0) Micro SD logo Graphics height 4,5mm acc to 1235-6655 Line 2 (8,0/20,0) SIM-card logo Graphics height 6,0mm acc to 1235-2274 Line 3a (10,0/2,0) Sony Ericsson stylized name. Graphics, height 1,5 mm. According to 1200-1925 Line 3b (10,0/16,0) Model Name “X000x” Text, height 1,2 mm. According to Chapter 1 in MLCI. Line 4a (12,0/2,0) Product number of the Sales Item in which the phone is packed, if applicable. “SI XXXX-XXXX” Text, height 1,2 mm. Line 4b (12,0/20,0) Location code of where the phone is flashed, if applicable, “XXX” Text, height 1,2 mm. Line 5a (15,0/2,0) “TYPE: AAD-3880071-BV” Text, height 1,2 mm. According to Chapter 1 in MLCI. Line 5b (15,0/20,0) HW & SW identification field, if applicable; “FFGG” Text, height 1,2 mm. According to Type-testing report under Product Model Specifying Documents Line 6a (17,0/2,0) ”FCC ID: PY7A3880071” Text, height 1,2 mm. According to Chapter 1 in MLCI. Line 6b (17,0/20,0) Production week (flash), “yy’W’ww” (yy = year, ww = week) Text, height 1,2 mm. Line 7a (19,0/2,0) “IC: 4170B-A3880071” Text, height 1,2 mm. According to Chapter 1 in MLCI. 2 ( 4) Company Internal MARKING DRAWI NG Prepared (also subject responsible if other) No. SEM/CVVGP, Anna Englund 1238-3476 Uen Approved Checked Date Rev Reference SEM/CVVGP, Anna Englund 2010-05-04 2 15 Line 7b (19,0/20,0) Repair week, if applicable. “Ry’W’ww” (y = year, ww = week) Text, height 1,2 mm. Line 8 (20,0/32,0) WEEE trashcan without bar symbol Graphics, min. height 5mm, according to 1202-5537. Line 9 (24,0/4,0) Line 9 in bar code, according to line 10a. As desired by supplier (e.g. only actual number). Bar code, height 2,0 mm. As desired by supplier (e.g. Code 128 symbology). Line 10a (26,0/2,0) Supplier’s identification for trace-ability of the telephone, as desired by supplier (e.g. “S/N: nnn....” for serial number). Text, height 1,2 mm. Defined by supplier. Line 10b (26,0/17,0) Actual electronic serial number (IMEI) of the mobile phone, “00000000-000000-0” Text, height 1,2 mm. In the format TAC-SNR-CD. TAC and SNR derived from pos 500 in BOM. CD = check digit according to the Luhn formula (ISO/IEC 7812), GSM 02.16. Line 11 (29,0/4,0) Line 10b in bar code (only actual number, without data identifier). Bar code, height 2,0 mm. Code 128 symbology, code C subset. If uneven number of digits, code B subset shall be used for the last digit. Line 12 (30,8/2,0) Marking of origin. “Made in Xxx”; “Xxx” = actual country of production of the included telephone, in English Text, height 1,2 mm. Line 13a (36,5/2,0) CE approval symbol Graphics, height 5 mm. According to 1210-0131. Line 13b (36,5/9,5) The notified body number “0682” Text, height 5mm Line 13c (36,5/21,5) “Alert Symbol” Graphics, height 5 mm According to 1001-5859 Company Internal MARKING DRAWING 3 (4) Prepared (also subject responsible if other) No. SEM/CVVGP, Anna Englund 1238-3476 Uen Approved Checked Date Rev Reference SEM/CVVGP, Anna Englund 2010-05-04 2 15 3 Layout The conceptual picture (for Zebra 90XiII printer, or equivalent) should not be considered as specifications, but as an additional help for setting up the label. 3.1 Conceptual picture double underlined = major changes since last revision. Company Internal MARKING DRAWING 4 (4) Prepared (also subject responsible if other) No. SEM/CVVGP, Anna Englund 1238-3476 Uen Approved Checked Date Rev Reference SEM/CVVGP, Anna Englund 2010-05-04 2 20 Label placement To find the label follow these steps: 1. Remove the cover on the rear side of the product. 2. Remove the battery. 3. The label is located behind the battery. Rear side of the phone Place for battery Label placement

Internal Photos

CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 24 of 33 Photo documentation: internal photos Photo 1: Photo 2: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 25 of 33 Photo 3: Photo 4: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 26 of 33 Photo 5: Photo 6: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 27 of 33 Photo 7: Photo 8: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 28 of 33 Photo 9: Photo 10: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 29 of 33 Photo 11: Photo 12: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 30 of 33 Photo 13: Photo 14: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 31 of 33 Photo 15: Photo 16: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 32 of 33 Photo 17: Photo 18: CETECOM ICT Services GmbH Annex to Test report no.: 1-1954-23-02/10 Annex 2010-04-28 Page 33 of 33 Photo 19:

RF Exposure Info

Company Internal REPORT 1 (19) Prepared (also subject responsible if other) No. LD/SEMC/CVVBALE Kent Lorentzon CVVA10:213 Approved Checked Date Rev Reference BA/SEMC/CVVBAU Jon Kenny JK 100518 A File Report issued by Accredited SAR Laboratory for FCC ID: PY7A3880071 IC: 4170B-A3880071 Date of test: 2010-04-27 to 2010-05-04 Laboratory: Sony Ericsson SAR Test Laboratory Sony Ericsson Mobile Communications AB Nya Vattentornet SE-221 88 Lund, Sweden Testing Engineer: Kent Lorentzon [email protected] +46 10 80 19043 Testing Approval: Jon Kenny [email protected] +44 1252 55 5711 Statement of Compliance Sony Ericsson Mobile Communications AB declares under its sole responsibility that the product Sony Ericsson Type AAD-3880071-BV; FCC ID PY7A3880071; IC 4170B-A3880071 to which this declaration relates, is in conformity with the appropriate RF exposure standards recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (None) This laboratory is accredited to ISO/IEC 17025 (SWEDAC accreditation no. 1847). Laboratories are accredited by the Swedish Board for Accreditation and Conformity Assessment (SWEDAC) under the terms of Swedish legislation. The accredited laboratory activities meet the requirements in SS-EN ISO/IEC 17025 (2005). This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Sony Ericsson encourages all feedback, both positive and negative, on this report. © Sony Ericsson Mobile Communication AB, 2010 Company Internal REPORT 2 (19) Prepared (also subject responsible if other) No. LD/SEMC/CVVBALE Kent Lorentzon CVVA10:213 Approved Checked Date Rev Reference BA/SEMC/CVVBAU Jon Kenny JK 100518 A File Table of contents 1 INTRODUCTION ............................................................................................................................................................. 3 2 CUSTOMER DETAILS .................................................................................................................................................... 3 3 DEVICE UNDER TEST ................................................................................................................................................... 3 3.1 ANTENNA DESCRIPTION .............................................................................................................................................. 3 3.2 DEVICE DESCRIPTION .................................................................................................................................................. 4 3.3 HSPA POWER CHARACTERISTICS ................................................................................................................................ 6 4 TEST EQUIPMENT.......................................................................................................................................................... 8 4.1 DOSIMETRIC SYSTEM ................................................................................................................................................... 8 4.2 ADDITIONAL EQUIPMENT ............................................................................................................................................. 8 5 ELECTRICAL PARAMETERS ON THE TISSUE SIMULATING LIQUID ............................................................ 9 6 SYSTEM ACCURACY VERIFICATION .................................................................................................................... 10 7 SAR MEASUREMENT UNCERTAINTY .................................................................................................................... 11 8 TEST RESULTS .............................................................................................................................................................. 12 9 REFERENCES ................................................................................................................................................................ 15 APPENDIX ............................................................................................................................................................................... 16 9.1 PHOTOGRAPHS OF THE DEVICE UNDER TEST ............................................................................................................... 16 9.2 DEVICE POSITION AT SAM TWIN PHANTOM .............................................................................................................. 17 9.3 ATTACHMENTS .......................................................................................................................................................... 19 Company Internal REPORT 3 (19) Prepared (also subject responsible if other) No. LD/SEMC/CVVBALE Kent Lorentzon CVVA10:213 Approved Checked Date Rev Reference BA/SEMC/CVVBAU Jon Kenny JK 100518 A File 1 Introduction In this test report, compliance of the Sony Ericsson FCC ID: PY7A3880071 (U20a) portable telephone with RF safety guidelines is demonstrated. The applicable RF safety guidelines and the SAR measurement specifications used for the test are described in the SAR Measurement Specifications of Wireless Handsets [1]. 2 Customer details Company Name: Sony Ericsson Mobile Communications AB Address: Sony Ericsson, Lund, Sweden Contact Name: Ola Samuelsson 3 Device Under Test 3.1 Antenna Description Type Internal antenna Location Bottom of the phone Main and BT antennas distance 65,3 mm Dimensions Max length 46 mm Max width 10 mm Configuration PIFA Company Internal REPORT …

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Phone: +49 (0) 681-598-0 Fax: -9075 RSC-Laboratory 2010-04-28 Page 1 of 127 Accredited testing-laboratory DAR registration number: DGA-PL-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3462C-1 (IC) Certification ID: DE 0001 Accreditation ID: DE 0002 Accredited Bluetooth ® Test Facility (BQTF) The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Cetecom ICT is under license Test report no. : 1-1954-23-02/10 Type identification : AAD-3880071-BV Applicant : Sony Ericsson Mobile Communications AB FCC ID : PY7A3880071 IC Certification No : 4170B-A3880071 Test standards : 47 CFR Part 22 47 CFR Part 24 RSS - 132 Issue 2 RSS - 133 Issue 5 CETECOM ICT Services GmbH Test report no.: 1-1954-23-02/10 2010-04-28 Page 2 of 127 Table of contents 1 G e n e r a l i n f o r m a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 3 1.1 Notes ...................................................................................................................................................................3 1.2 Testing laboratory ...............................................................................................................................................4 1.3 Details of applicant .............................................................................................................................................4 1.4 Application details ..............................................................................................................................................4 2 T e s t s t a n d a r d / s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . 5 3 T e c h n i c a l t e s t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . 6 3.1 Details of manufacturer .......................................................................................................................................6 3.1.1 Test item......................................................................................................................................................6 3.2 Test Setup............................................................................................................................................................8 4 S t a t e m e n t o f C o m p l i a n c e . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 9 4.1 Summary of Measurement Results......................................................................................................................9 4.1.1 PCS 1900.....................................................................................................................................................9 4.1.2 GSM 850 .....................................................................................................................................................9 4.1.3 UMTS Band II...........................................................................................................................................10 4.1.4 UMTS Band V ..........................................................................................................................................10 4.1.5 Receiver ....................................................................................................................................................10 5 M e a s u r e m e n t s a n d r e s u l t s . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . 1 1 5.1 PART PCS 1900 ...............................................................................................................................................11 5.1.1 RF Power Output.......................................................................................................................................11 5.1.2 Frequency Stability ...................................................................................................................................16 5.1.3 Radiated Emissions ...................................................................................................................................19 5.1.4 Conducted Spurious Emissions .................................................................................................................28 5.1.5 Block Edge Compliance............................................................................................................................31 5.1.6 Occupied Bandwidth .................................................................................................................................34 5.2 PART GSM 850 ................................................................................................................................................41 5.2.1 RF Power Output.......................................................................................................................................41 5.2.2 Frequency Stability ...................................................................................................................................45 5.2.3 Radiated Emissions ...........…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mika Kaneko(Chief Regulatory Compliance Manager)
[email protected]+81367103225Fax: +815038096297

Technical Contact

Sony Ericsson Mobile Communications ABJohan Wedin Svensk
[email protected]

Nya Vattentornet · Lund · Sweden

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
624E1.85 GHz - 1.91 GHz190.00 mW4M93F9W0.0282 ppm
Confidentiality
Long Term
Grant Notes
Output power is ERP for Part 22 and EIRP for Part 24. This filing is only applicable for 850/1900 MHz PCS, WLAN and Bluetooth operations. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22: Head: 0.31W/kg - Body-worn: 0.76W/kg; Part 24: Head: 1.48W/kg - Body-worn: 0.71W/kg; Part 15: Head: 0.14W/kg - Body-worn: 0.20W/kg

Other Applications from Sony Corporation

PY7-75158T

GSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS

Jul 16, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
PY7-52715J

GSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS

Jul 16, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PY7-84526Y

GSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac/ax, NFC and GNSS

Jul 16, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
PY7-30515Z

GSM/WCDMA/LTE/NR Phone with BT, DTS/UNII a/b/g/n/ac/ax/be, NFC, GNSS and WPT

Apr 13, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PY7-73716J

GSM/WCDMA/LTE Phone with BT, DTS/UNII a/b/g/n/ac, NFC and GNSS

Apr 11, 2024

Equipment Class

PCE - PCS Licensed Transmitter held to ear