Q22-IF2802ASmart Body Fat Scale

Zhongshan Camry Electronic Co.,LTD.
Smart Body Fat Scale - FCC ID Q22-IF2802A - Zhongshan Camry Electronic Co.,LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 08, 2023
Application Purpose
Original Equipment
Date of Application
Oct 08, 2023
Equipment Note
Smart Body Fat Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhongshan Camry Electronic Co.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

21345 ● Body composition measuring and analyzing PICTURE 1: TOP VIEW OF PRODUCT (FRONT SIDE) PICTURE 2: TOP VIEW OF PRODUCT (BACK SIDE) Handle Electrode(1) for left hand Electrode(1) for right hand Data line Electrode (1) for left foot Electrode (2) for left foot LED display Electrode (1) for right foot Electrode (2) for right foot Scale body Electrode(2) for right hand Electrode(2) for left hand Batter y case MovingLife 1. BATTERY INSTALLATION AND CHANGING 4x1.5V AAA batteries, please install as shown below: Fir st Use: Remove the insulation sheet before using ( Noteif the batter y is included ). Change batter y: Open the batter y cover , take out the used batteries, then install the new ones pr operly as directed shown below NotePlease use the right batter y. R emove batter y if the scale leaves unused for more than 3 months. 2. DOWNLOAD AND SET UP THE APPLICATION Search “MovingLife” in “App Stor e” or “Google Play” to download the Application. Or in another most convenient way by scanning the QR code below. TipsAPP is kept updating, so it may differ fr om showed on manual. For the final and accurate information, please check on App. 3. CONNECTING AND REGISTERING Open APP "MovingLife", connect the scale with App Submit your personal profile as directed on the App TipsBefore connection, please make sure the Bluetooth on the smart device is on, and the scale is also turned on; In order to ensure the measuring accuracy, please make sure the personal profile you submitted is correct. The display is lighted up Step gently to turn on the scale Connect the scale with APP 4. MEASURING Place the scale on the hard flat floor Check out the body composition data on APP TipsActual numbers of users depend on the product's storage. 5. MULTIPLE USERS SUPPORTED The App can support multiple users, and each user can be with 15 groups histor y data maximum. Data will be automatically synchronizing to the phone when the App is on ● Installing Hold the two front electrodes with thumbs Hold the two back electrodes with rest fingers Hold the handle and stand on the scale 6. DISPLAY ICONS MeasuringLow battery power Over loaded Re-measuring needed Too low body fat rate Too high body fat rate Tips In order to ensure the measuring accuracy, please hold the handle and stand on the scale as directed. Please wait patiently until the measuring finished which will take about 20 seconds All the measuring should be finished with handle, otherwise, only weighing function is workable. All measuring should be finished with App, if the smart device is not available, the scale body will only show the weight data (certain item will show the body fat and body water data also, please refer to the actual product) Before measuring, please connect the handle and scale body with the data line. 1. Place the scale on hard flat floor, run the APP on the smart device. 2. Lift up the handle, stand slightly on the 4 electrodes on the scale with bar e feet; Hold the handle as picture shown, adjust the height of both hands and keep your arms unbend (keep your arms away from waist). 3. When the measuring is finished, the scale starts to analyze the body composition. After a fews seconds, all the body composition data will be shown on APP and saved automatically. The scale will be auto off if there is no any further operation. App: MovingLife 22iF-017E R2 786 1.To ensure the accuracy of the data, it is recommended that each measurement be carried out at the same time of day. Don't use in strong electro-magnetic condition and field with intense shake . 2.If the scale leaves unused for long time, when first weighing, please tap on the scale t o make display show zero and let the scale be off automatically. Then you can tap on again t o start weighing. 3.To ensure the measuring accuracy, please take off the shoes and socks and other heavy belongs, keep your hands and feet clean, and then stand on the scale with bare feet and hold the handle with both hands. 4.Since the scale surface is smooth, please do not use the scale on slippery floor or stand on the edge of the scale; Always stand onto the central part of the scale and adjust your feet to touch the 4 electrodes after you s tand stably. Please keep standing firmly and balanced to prevent sliding. 5.Measuring results will be not accurate after s trong ex ercises, overeating or in seriously dehydrated status. 6.Regarding the body composition analyzing, the measuring data may be not accurate for the below users: ● Children under 18 or adults over 70 ● Professional sporters such as body builder 7.Below people are not suggested to use this product: ● Pregnant women, Artificial dialysis patients, Bloated body status ● People who are with heart pacemakers or other medical instruments inside the body are forbidden to use this product 8.When the batteries run out, please remove the batteries in time to prevent leakage of the battery lead scale body corrosion; 9.Do not drop, shock or stri ke the scale as it is a precise instrument. 10.Keep the scale clean. Do not use acid cleaning agent. I n s tructions for Use iF-17 S E RIES ISO 9001 CERTIFIED BY SGS Manufacturer: Zhongshan Camry Electronic Co., Ltd. Address: Baishawan Industri al Park, Qiwan Road(N), East District, Zhongshan City, Guangdong Province Postal Code: 528403 Tel: 0760-88235622 Fax: 0760-88235600 Email: [email protected] The product picture is indicative only. Appearance specifications please in kind prev ail. UNIT 7. ABOUT THE UNIT It is suggested to set the unit on App Or you can change the unit by the UNIT switch button on bottom of the scale(If the scale is with such button). The factory unit setting differs from different sales destination. Please refer to the actual product. ADVICE FOR USE & CARE USER-FRIENDLY TIPS The body composition data are for reference purpose. Should not be used for medical treatment and can not be used in any medical institution. Growing children, pregnant women, those with symptom of edema or, on heart byp…

Text truncated - open the document above for the full version.

Cover Letter(s)

Zhongshan Camry Electronic Co.,LTD. Baishawan Industrial Park, Qiwan Road(N), East Dis, zhongshan 528403, China Agent Authorization Company: Zhongshan Camry Electronic Co.,LTD. Address: Baishawan Industrial Park, Qiwan Road(N), East Dis, zhongshan 528403, China Product Name: Smart Body Fat Scale Model Number(s): iF2802A, iF2801A Product Description: Smart Body Fat Scale We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Sep. 14, 2023 Name: Carry Xu Title: General Manager Company: Zhongshan Camry Electronic Co.,LTD.

Cover Letter(s)

Zhongshan Camry Electronic Co.,LTD. Baishawan Industrial Park, Qiwan Road(N), East Dis, zhongshan 528403, China Sep. 14, 2023 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID: Q22-IF2802A Models: iF2802A, iF2801A To Whom It May Concern: We, The Zhongshan Camry Electronic Co.,LTD hereby declare that the model : iF2802A is identical with the model : iF2801A, The glass looks different in color. Except for the different above, no other modification is performed. Sincerely, Zhongshan Camry Electronic Co.,LTD Signature: [Carry Xu, General Manager]

External Photos

Report No.: AGC09355230704AP02 Page 1 of 4 EXTERNAL PHOTOS All VIEW OF EUT TOP VIEW OF EUT Report No.: AGC09355230704AP02 Page 2 of 4 BOTTOM VIEW OF EUT FRONT VIEW OF EUT Report No.: AGC09355230704AP02 Page 3 of 4 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC09355230704AP02 Page 4 of 4 RIGHT VIEW OF EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID Label Location 10mm*20mm FCC ID: Q22-IF2802A

Internal Photos

Report No.: AGC09355230704AP02 Page 1 of 4 INTERNAL PHOTOS OPEN VIEW OF EUT (FIGURE 1) OPEN VIEW OF EUT (FIGURE 2) Report No.: AGC09355230704AP02 Page 2 of 4 INTERNAL VIEW OF EUT (FIGURE 1) INTERNAL OF EUT (FIGURE 2) Report No.: AGC09355230704AP02 Page 3 of 4 INTERNAL OF EUT (FIGURE 2) INTERNAL OF EUT (FIGURE 2) Report No.: AGC09355230704AP02 Page 4 of 4 INTERNAL OF EUT (FIGURE 3) ****************************************End of Report************************************* BT Antenna

RF Exposure Info

RF EXPOSURE EVALUATION 1. PRODUCT INFORMATION FCC ID Q22-IF2802A Product Description Smart Body Fat Scale Model Name iF2802A Frequency Band (Operating) WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz WLAN: 5.745GHz ~ 5825GHz Bluetooth: 2.402GHz ~ 2.480GHz Others (NFC:13.56MHz) Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Max. Output Power 3.381dBm (Max) Antenna Gain 3.85dBi Minimum Assessment Distance 5mm Evaluation Applied MPE Evaluation SAR Evaluation Evaluation Result Pass 2. PORTABLE DEVICE EVALUATION METHOD AND LIMIT Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz.  Power and distance are rounded to the nearest mW and mm before calculation.  The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm) ( f(MHz)/150)] mW, at 100MHz to 1500 MHz; b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)-10] mW at > 1500 MHz and ≤6 GHz; 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by 1/2 for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. 3. MOBILE DEVICE EVALUATION METHOD AND LIMIT Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (Minutes) 0.3 -- 1.34 614 1.63 (100)* 30 1.34 -- 30 824/f 2.19/f (180/f 2 )* 30 30 -- 300 27.5 0.073 0.2 30 300 -- 1500 -- -- f/1500 30 1500 -- 100,000 -- -- 1.0 30 *Note: 1. f= Frequency in MHz * Plane-wave Equivalent Power Density 2. The averaging time for General Population/Uncontrolled exposure to fixed transmitters is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091 and 2.1093 on source-based time-averaging requirement for mobile and portable transmitters. S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. MEASUREMENT RESULT Test Mode Channel Frequency (MHz) Max Output power (dBm) Max Output power (mW) Calculation Value (Note 1) Limit Value GFSK BT_BR 2480 3.381 2.178 0.69 3.0 Note 1: Calculation Value =[(max. power of channel, mW)/(min. test separation distance, mm)] ·[√f(GHz)]. Fox example: 2.178 /5*√2.480=0.69≤ 3.0 5. CONCLUSION Since Source-base time average power is below SAR test exclusion power thresholds, the SAR evaluation is not required.

Test Report

Page 1 of 42 FCC Test Report Report No.: AGC09355230704FR01 FCC ID : Q22-IF2802A APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Smart Body Fat Scale BRAND NAME : SENSSUN MODEL NAME : iF2802A, iF2801A APPLICANT : Zhongshan Camry Electronic Co.,LTD. DATE OF ISSUE : Aug. 22, 2023 STANDARD(S) : FCC Part 15 Subpart C §15.247 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC09355230704FR01 Page 2 of 42 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 22, 2023 Valid Initial Release Report No.: AGC09355230704FR01 Page 3 of 42 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE .................................................................................................................. 5 2. GENERAL INFORMATION .............................................................................................................................. 6 2.1. PRODUCT DESCRIPTION ........................................................................................................................ 6 2.2. TABLE OF CARRIER FREQUENCYS ....................................................................................................... 6 2.3. RELATED SUBMITTAL(S)/GRANT(S) ...................................................................................................... 7 2.4. TEST METHODOLOGY ............................................................................................................................. 7 2.5. SPECIAL ACCESSORIES ......................................................................................................................... 7 2.6. EQUIPMENT MODIFICATIONS ................................................................................................................ 7 2.7. ANTENNA REQUIREMENT ....................................................................................................................... 7 3. MEASUREMENT UNCERTAINTY ................................................................................................................... 8 4. DESCRIPTION OF TEST MODES ................................................................................................................... 9 5. SYSTEM TEST CONFIGURATION ................................................................................................................ 10 5.1. CONFIGURATION OF TESTED SYSTEM .............................................................................................. 10 5.2. EQUIPMENT USED IN TESTED SYSTEM ............................................................................................. 10 5.3. SUMMARY OF TEST RESULTS ............................................................................................................. 10 6. TEST FACILITY .............................................................................................................................................. 11 7. PEAK OUTPUT POWER ................................................................................................................................ 12 7.1. MEASUREMENT PROCEDURE ............................................................................................................. 12 7.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 12 7.3. LIMITS AND MEASUREMENT RESULT ................................................................................................. 13 8. BANDWIDTH .................................................................................................................................................. 15 8.1. MEASUREMENT PROCEDURE ............................................................................................................. 15 8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 15 8.3. LIMITS AND MEASUREMENT RESULTS .............................................................................................. 15 9. CONDUCTED SPURIOUS EMISSION........................................................................................................... 19 9.1. MEASUREMENT PROCEDURE ............................................................................................................. 19 9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 19 9.3. MEASUREMENT EQUIPMENT USED .................................................................................................... 19 9.4. LIMITS AND MEASUREMENT RESULT ................................................................................................. 19 10. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY ........................................................ 26 10.1. MEASUREMENT PROCEDURE ........................................................................................................... 26 10.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................. 26 10.3. MEASUREMENT EQUIPMENT USED .................................................................................................. 26 10.4. LIMITS AND MEASUREMENT RESULT ............................................................................................... 26 Report No.: AGC09355230704FR01 Page 4 of 42 11. RADIATED EMISSION ................................................................................................................................. 28 11.1. MEASUREMENT PROCEDURE ........................................................................................................... 28 11.2. TEST SETUP ......................................................................................................................................... 29 11.3. LIMITS AND MEASUREMENT RESULT .............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: AGC09355230704AP01 Page 1 of 2 TEST SETUP PHOTOS RADIATED EMISSION TEST SETUP BELOW 1GHz RADIATED EMISSION TEST SETUP ABOVE 1GHz Report No.: AGC09355230704AP01 Page 2 of 2 RF CONDUCTED TEST SETUP ****************************************End of Report*************************************

Contact Information

Applicant

Carry Xu
[email protected]0760-88269930Fax: +86-0760-88269939

Technical Contact

Zhongshan Camry Electronic Co.,LTD.
[email protected]

China

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.20 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from Zhongshan Camry Electronic Co.,LTD.

Weighplate - FCC ID Q22-IN4926B - Zhongshan Camry Electronic Co.,LTD.
Q22-IN4926B

Weighplate

Feb 10, 2026

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID Q22-IF1131D - Zhongshan Camry Electronic Co.,LTD.
Q22-IF1131D

Smart Body Fat Scale

Aug 11, 2024

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID Q22-IF1090D - Zhongshan Camry Electronic Co.,LTD.
Q22-IF1090D

Smart Body Fat Scale

Jul 18, 2024

Equipment Class

DTS - Digital Transmission System
Q22-IF2825A

Smart Body Fat Scale

Apr 10, 2024

Equipment Class

DTS - Digital Transmission System
Bluetooth Body Scale - FCC ID Q22IB931B - Zhongshan Camry Electronic Co.,LTD.
Q22IB931B

Bluetooth Body Scale

Jun 03, 2015

Equipment Class

DTS - Digital Transmission System