FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Camry Electronic Co.,LTD./
  3. Q22-IN4926B

Q22-IN4926BWeighplate

Zhongshan Camry Electronic Co.,LTD.
Weighplate - FCC ID Q22-IN4926B - Zhongshan Camry Electronic Co.,LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 10, 2026
Application Purpose
Original Equipment
Equipment Note
Weighplate
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhongshan Camry Electronic Co.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Photos are only for indicative, please refer to actual product. Our company owns final interpretation right for the product. Weighplate iN4926B Instructions for Use 56 1.The item is IP67 dust and water proof designed. It can be washable, immersed in water with depth within 1 meter within 30 minutes. The scale can not be used right after taking from water. Please wipe up the scale, especially the breathable membrane with cloth, and dry it in cool and ventilate place before using again. 2. This product is not dishwasher safe and must not be placed or used in a microwave oven. 3. All plastics parts should be cleaned immediately after contacting with fats, spices, vinegar and strongly flavored/colored foods. (Avoid contacting with acids citrus juice.) DO NOT clean the item with chemical / corrosive cleaner. 4. Always use the scale on a solid, flat surface, keep the scale unmoved when weighing. 5. This product is precise instrument, please handle with care; Do not strike, shake or drop the scale. 6. The normal working temperature range of the product is 0-60°C, but it can also be briefly exposed to food with temperature not higher than 100°C. 7. If fail to turn on or can't work normally, please check whether battery is low and needs to charge. If still not solved, please contact your distributor. 8. This product can’t be discarded as household garbage and should be sent to collection points for electrical and electronic equipment. 9. Designed for family use only, not for commercial use. Breathable membrane WARNING OVER LOADED WARNING When display shows “Err”, it is over loaded( Max capacity is shown on product), please take off the loads to prevent damage to the scale. LOW BATTERY WARNING When display shows “Lo”, battery power is low, Please charge in time. ADVICE FOR USE & CARE The silicone cover of the charging terminal should be closed before putting into water. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful i nterference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 123 ON/OFF button LED display TARE button UNIT button Platform TYPE-C charging terminal Back Convert between Metric and Imperial system Metric unit Imperial unit PRODUCT LAYOUT With high precision load cell IP67 designed Low battery and overloaded warning function Tare and unit/mode conversion with touch button Auto off function Water & milk & oil volume measuring function Bluetooth UNIT TARE Breathable membrane FEATURES CHARGING Note * When used first time or stored for long time, please charge the scale fully before use. * To avoid damage to built-in lithium battery, please charge every 3 months if not used for long time. * If the product can't work normally, please charge to reset. The scale is powered by 3.7V/400mAh chargeable polymer lithium battery. Adapter: DC 5V, output current 0.5A or above. Charging: flash. Fully charged: indicators “FULL”. Time to charge fully: about 2 hours. TARE ON/OFF BUTTONS FUNCTION UNIT/MODE changing Weight mode Water mode Milk mode Oil mode Negative Value Tare WeightVolume unit Volume unit Weight unit Weight unit DISPLAY ICONS INDICATION Remark: Display differs from one product to another, so above icons are only for indicative. OPERATION Place the scale on solid and flat surface. UNIT/MODE conversion Turn on Remark: UNIT/MODE conversion method differs from one product to another, so above operation is only for indicative. Press Long press 4 3 4 12 Press " " button at the bottom of scale to switch on, wait until display shows zero. WEIGHING Press "UNIT" to switch mode; Press "TARE" to tare(if any); Remark: These pictures are only for indicative, appearance & button of actual product maybe different from above. Total weight of container & object can't exceed Max. capacity of product. Auto off if idle for 2 minutes. Load objects, display shows the weight; Press" " to turn off manually;

Attestation Statements

2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: Zhongshan Camry Electronic Co., LTD. Address: Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China FCC ID: Q22-IN4926B Date: Jan. 22, 2026 2.911(d)(7) USA Designated Agent for Service of Process We, [Zhongshan Camry Electronic Co., LTD.] (“the applicant”) designate [Wedo Group] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Wedo Group Address: 710 Arabian Ln Walnut, CA 91789, United States FRN:0037730611 Contact Name: Jeffrey Chen Telephone No: (323) 528-1888 Email: [email protected] Applicant Company name: Zhongshan Camry Electronic Co., LTD. Address: Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China FRN: 0032742710 Contact Name: Carry Xu Telephone No: 0760-88269930 Email: [email protected] Signature: Signature:

Attestation Statements

Zhongshan Camry Electronic Co., LTD. Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China 1 | P a g e Attestation Statements To: Federal Communications Commission Date: Jan. 22, 2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: Q22-IN4926B Product Name: Weighplate This letter serves as an attestation that the equipment identified above ☐ is / ☒ is not (select one) "covered" software as defined under the Federal Communications Commission (FCC) Covered List requirements, as outlined in FCC 22-84 and KDB 986446. Specifically, the undersigned certifies that the equipment for which authorization is sought: 1. Does not contain cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors, assignees, parents, subsidiaries, affiliates, or any entity that has rebranded or relabeled software produced by the aforementioned entities. 2. Does not have the capability to store, run, or deliver any software identified on the FCC Covered List, including but not limited to cybersecurity and anti-virus software. To support this attestation, the appendix evaluation documentation has been prepared and is included in the certification filing. This attestation is based on a thorough evaluation of the device's design, functionality, and software environment. The undersigned affirms that the information provided is accurate and complete to the best of their knowledge. Sincerely yours, Applicant Signature Printed Name: Carry Xu Title: General Manager Address: Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China Tel.: 0760-88269930 Email: [email protected] Zhongshan Camry Electronic Co., LTD. Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China 2 | P a g e Evaluation regarding to the Covered List Software: Compliance Methodology Evaluation Process Results Device is Inherent compliance ☒ The Chipset(s) used is limited to run the Cybersecurity or anti-virus software. Compliance ☐ The Memory used is limited to run the Cybersecurity or anti-virus software. Compliance ☐ There is storage capacity limitation for store or install the Cybersecurity or anti-virus software. Compliance ☐ Operating system used is limited to run, install or deliver the Cybersecurity or anti-virus software. Compliance Device is not Inherent compliance ☐ Evaluation Based on Software Bill of Materials (SBoM) See attached “SBoM“ Note:The SBoM content is limited to the scope of covered list software (e.g. antivirus and cybersecurity software). ☐ Evaluation Based on Scan for Software on the device ☐ Evaluation Based on Filesystem scan ☐ Evaluation Based on Running software check

Cover Letter(s)

Zhongshan Camry Electronic Co., LTD. Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China (Jan. 22, 2026) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: Q22-IN4926B I, the undersigned, hereby authorize (Attestation of Global Compliance (Shenzhen) Co., Ltd) to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by (Attestation of Global Compliance (Shenzhen) Co., Ltd) shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with (Zhongshan Camry Electronic Co., LTD.). We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, (Signature) (Full name of contact person listed on FCC’s website) Carry Xu (General Manager) Tel.: 0760-88269930 Email: [email protected]

External Photos

Report No.: AGC09355260102AP02 Page 1 of 4 EXTERNAL PHOTOS ALL VIEW OF EUT TOP VIEW OF EUT Report No.: AGC09355260102AP02 Page 2 of 4 BOTTOM VIEW OF EUT FRONT VIEW OF EUT Report No.: AGC09355260102AP02 Page 3 of 4 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC09355260102AP02 Page 4 of 4 RIGHT VIEW OF EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID Label Location 20mm*15mm FCC ID: Q22-IN4926B

Internal Photos

Report No.: AGC09355260102AP02 Page 1 of 5 INTERNAL PHOTOS OPEN VIEW OF EUT (FIGURE 1) INTERNAL VIEW OF EUT (FIGURE 1) Report No.: AGC09355260102AP02 Page 2 of 5 INTERNAL VIEW OF EUT (FIGURE 2) INTERNAL VIEW OF EUT (FIGURE 3) Report No.: AGC09355260102AP02 Page 3 of 5 INTERNAL VIEW OF EUT (FIGURE 4) INTERNAL VIEW OF EUT (FIGURE 5) Report No.: AGC09355260102AP02 Page 4 of 5 INTERNAL VIEW OF EUT (FIGURE 6) INTERNAL VIEW OF EUT (FIGURE 7) BT Antenna Report No.: AGC09355260102AP02 Page 5 of 5 BATTERY VIEW OF EUT(FIGURE 1) ****************************************End of Report*************************************

RF Exposure Info

Page 1 of 10 RF Exposure Report Report No.: AGC09355260102FH01 FCC ID : Q22-IN4926B APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Weighplate BRAND NAME : N/A MODEL NAME : iN4926B APPLICANT : Zhongshan Camry Electronic Co., LTD. DATE OF ISSUE : Jan. 22, 2026 STANDARD(S) : FCC Part 2 Subpart J §2.1093 FCC KDB 447498 D01 V06 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC09355260102FH01 Page 2 of 10 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jan. 22, 2026 Valid Initial Release Report No.: AGC09355260102FH01 Page 3 of 10 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 3. Test Environment ............................................................................................................................................ 6 3.1 Address Of The Test Laboratory ............................................................................................................... 6 3.2 Test Facility ................................................................................................................................................ 6 3.3 Environmental Conditions ......................................................................................................................... 7 4. Portable Device Evaluation Method and Limit ............................................................................................. 8 5. Measurement Results ..................................................................................................................................... 9 6. Measurement Evaluation ................................................................................................................................ 9 Report No.: AGC09355260102FH01 Page 4 of 10 1. General Information Applicant Zhongshan Camry Electronic Co., LTD. Address Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China Manufacturer Zhongshan Camry Electronic Co., LTD. Address Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China Factory Zhongshan Camry Electronic Co., LTD. Address Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China Product Designation Weighplate Brand Name N/A Test Model iN4926B Series Model(s) N/A Difference Description N/A Date of receipt of test item Jan. 12, 2026 Date of Test Jan. 12, 2026 to Jan. 22, 2026 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RF Exposure-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Jasiel Xie (Project Engineer) Jan. 22, 2026 Reviewed By Jack Gui (Reviewer) Jan. 22, 2026 Approved By Angela Li (Authorized Officer) Jan. 22, 2026 Report No.: AGC09355260102FH01 Page 5 of 10 2. Product Information 2.1 Product Technical Description Frequency Band (Operating) 2.402GHz ~ 2.480GHz Hardware Version iN4926BCV2 Software Version AC6328A_Senssun_V1.0.4_5C29-30AA9F5D Maximum Transmitter Power BLE (1Mbps): -4.562 dBm BLE (2Mbps): -4.328 dBm Device Category Portable (<20cm separation) Mobile (>20cm separation) Others: Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Designation PCB Antenna Antenna Gain 2.39dBi Minimum Assessment Distance 5mm Evaluation Applied MPE Evaluation SAR Evaluation Report No.: AGC09355260102FH01 Page 6 of 10 3. Test Environment 3.1 Address Of The Test Laboratory Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to follow CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories.) A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to follow ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. FCC-Registration No.: 975832 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files with Registration 975832. IC-Registration No.: 24842(CAB identifier: CN0063) Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the Certification and Engineering Bureau of Industry Canada. The acceptance letter from the IC is maintained in our files with Registration 24842. Report No.: AGC09355260102FH01 Page 7 of 10 3.3 Environmental Conditions NORMAL CONDITIONS Temperature range (°C) 15 - 35 Relative humidity range 20 % - 75 % Pressure range (kPa) 86 - 106 Power supply DC 3.7V by battery or DC 5V by adapter Note: The Extreme Temperature and Extreme Voltages declared by the manufacturer. Report No.: AGC0935…

Text truncated - open the document above for the full version.

Test Report

Antenna specification Model: iN4926BCV2 Version: V1.00 Device Manufacturer: Zhongshan Camry Electronic CO., LTD PREPARED BY: LU YONGHU APPROVED BY: DATE: 2026.1.13 DATE: Baishawan Industrial Park, Qiwan Road(N) , East Dis, Zhongshan, Guangdong, 528403, China 1. PCB Location Definition 2. Antenna Dimensions 3. Antenna Gain Table 4. Pattern(Theta=90°) FreeSpace Frequency (MHz) Efficiency (dB) Efficiency (%) Gain(dBi) 2400 -7.00 19.96 1.79 2402 -6.97 20.07 1.75 2405 -6.90 20.40 1.90 2410 -6.90 20.43 1.94 2415 -6.86 20.59 2.00 2420 -6.85 20.63 2.07 2425 -6.78 20.98 2.11 2430 -6.75 21.14 2.16 2435 -6.67 21.54 2.14 2440 -6.52 22.29 2.30 2441 -6.52 22.29 2.29 2445 -6.50 22.39 2.24 2450 -6.44 22.68 2.34 2455 -6.42 22.79 2.33 2460 -6.45 22.64 2.39 2465 -6.39 22.97 2.37 2470 -6.56 22.10 2.31 2475 -6.48 22.51 2.32 2480 -6.60 21.88 2.23 2482 -6.54 22.19 2.34 2485 -6.44 22.72 2.32 5. VSWR 6. Stimulus 7. 2D Antenna Pattern(Theta=90°) 8. 3D Antenna Pattern

Test Report

Page 1 of 63 FCCTestReport ReportNo.:AGC09355260102FR01 FCCID: Q22-IN4926B APPLICATIONPURPOSE: OriginalEquipment PRODUCTDESIGNATION:Weighplate BRANDNAME:N/A MODELNAME:iN4926B APPLICANT:ZhongshanCamryElectronicCo.,LTD. DATEOFISSUE:Jan.22,2026 STANDARD(S):FCCPart15SubpartC§15.247 REPORTVERSION:V1.0 AttestationOfGlobalCompliance(Shenzhen)Co.,Ltd ReportNo.:AGC09355260102FR01 Page2of63 ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Jan.22,2026ValidInitialRelease ReportNo.:AGC09355260102FR01 Page3of63 TableofContents 1.GeneralInformation..........................................................................................................................................5 2.ProductInformation..........................................................................................................................................6 2.1ProductTechnicalDescription....................................................................................................................6 2.2TestFrequencyList.....................................................................................................................................6 2.3RelatedSubmittal(S)/Grant(S).................................................................................................................7 2.4TestMethodology........................................................................................................................................7 2.5SpecialAccessories....................................................................................................................................7 2.6EquipmentModifications.............................................................................................................................7 2.7AntennaRequirement.................................................................................................................................7 3.TestEnvironment..............................................................................................................................................8 3.1AddressoftheTestLaboratory...................................................................................................................8 3.2TestFacility..................................................................................................................................................8 3.3EnvironmentalConditions...........................................................................................................................9 3.4MeasurementUncertainty...........................................................................................................................9 3.5ListofEquipmentUse...............................................................................................................................10 4.SystemTestConfiguration.............................................................................................................................12 4.1EUTConfiguration.....................................................................................................................................12 4.2EUTExercise............................................................................................................................................12 4.3ConfigurationofTestedSystem................................................................................................................12 4.4EquipmentUsedInTestedSystem..........................................................................................................13 4.5SummaryofTestResults..........................................................................................................................14 5.DescriptionofTestModes.............................................................................................................................15 6.DutyCycleMeasurement...............................................................................................................................17 7.RFOutputPowerMeasurement....................................................................................................................18 7.1ProvisionsApplicable................................................................................................................................18 7.2MeasurementProcedure..........................................................................................................................18 7.3MeasurementSetup(BlockDiagramofConfiguration)...........................................................................18 7.4MeasurementResult.................................................................................................................................19 8.6dBBandwidthMeasurement.......................................................................................................................23 8.1ProvisionsApplicable................................................................................................................................23 8.2MeasurementProcedure..........................................................................................................................23 8.3MeasurementSetup(BlockDiagramofConfiguration)...........................................................................23 8.4MeasurementResults...............................................................................................................................24 9.PowerSpectralDensityMeasurement.........................................................................................................31 9.1ProvisionsApplicable................................................................................................................................31 9.2MeasurementProcedure..........................................................................................................................31 9.3MeasurementSetup(BlockDiagramofConfiguration)......…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:AGC09355260102FR01 Page41of63 Test_Graph_LE1M_ANT1_2480_1Mbps_HigherBandEmissions Test_Graph_LE2M_ANT1_2402_2Mbps_ReferenceLevel ReportNo.:AGC09355260102FR01 Page42of63 Test_Graph_LE2M_ANT1_2402_2Mbps_LowerBandEmissions Test_Graph_LE2M_ANT1_2402_2Mbps_HigherBandEmissions ReportNo.:AGC09355260102FR01 Page43of63 Test_Graph_LE2M_ANT1_2440_2Mbps_ReferenceLevel Test_Graph_LE2M_ANT1_2440_2Mbps_LowerBandEmissions ReportNo.:AGC09355260102FR01 Page44of63 Test_Graph_LE2M_ANT1_2440_2Mbps_HigherBandEmissions Test_Graph_LE2M_ANT1_2480_2Mbps_ReferenceLevel ReportNo.:AGC09355260102FR01 Page45of63 Test_Graph_LE2M_ANT1_2480_2Mbps_LowerBandEmissions Test_Graph_LE2M_ANT1_2480_2Mbps_HigherBandEmissions ReportNo.:AGC09355260102FR01 Page46of63 TestGraphsofBandEdgeEmissionsinNon-RestrictedFrequencyBands Test_Graph_LE1M_ANT1_2402_1Mbps_LowerBandEdgeEmissions Test_Graph_LE1M_ANT1_2480_1Mbps_HigherBandEdgeEmissions ReportNo.:AGC09355260102FR01 Page47of63 Test_Graph_LE2M_ANT1_2402_2Mbps_LowerBandEdgeEmissions Test_Graph_LE2M_ANT1_2480_2Mbps_HigherBandEdgeEmissions ReportNo.:AGC09355260102FR01 Page48of63 11.RadiatedSpuriousEmission 11.1MeasurementLimit  FCCPart15.209Limitinthebelowtabletobefollowed Frequencies (MHz) FieldStrength (microvolts/meter) MeasurementDistance (meters) 0.009~0.4902400/F(kHz)300 0.490~1.70524000/F(kHz)30 1.705~30.03030 30~881003 88~2161503 216~9602003 Above9605003 Note:Allmodesweretestedforrestrictedbandradiatedemission,thetestrecordsreportedbelowaretheworst resultcomparedtoothermodes. 11.2MeasurementProcedure 1.TheEUTwasplacedonthetopoftheturntable0.8or1.5meteraboveground.Thephasecenterofthe receivingantennamountedonthetopofaheight-variableantennatowerwasplaced3metersfaraway fromtheturntable. 2.PowerontheEUTandallthesupportingunits.Theturntablewasrotatedby360degreestodeterminethe positionofthehighestradiation. 3.Theheightofthebroadbandreceivingantennawasvariedbetweenonemeterandfourmetersabove groundtofindthemaximumemissionsfieldstrengthofbothhorizontalandverticalpolarization. 4.Foreachsuspectedemission,theantennatowerwasscan(from1Mto4M)andthentheturntablewas rotated(from0degreeto360degrees)tofindthemaximumreading. 5.Setthetest-receiversystemtoPeakorCISPRquasi-peakDetectFunctionwithspecifiedbandwidthunder MaximumHoldMode. 6.Foremissionsabove1GHz,use1MHzRBWand3MHzVBWforpeakreading.Placethemeasurement antennaawayfromeachareaoftheEUTdeterminedtobeasourceofemissionsatthespecified measurementdistance,whilekeepingthemeasurementantennaaimedatthesourceofemissionsateach frequencyofsignificantemissions,withpolarizationorientedformaximumresponse.Themeasurement antennamayhavetobehigherorlowerthantheEUT,dependingontheradiationpatternoftheemission andstayingaimedattheemissionsourceforreceivingthemaximumsignal.Thefinalmeasurement antennaelevationshallbethatwhichmaximizestheemissions.Themeasurementantennaelevationfor maximumemissionsshallberestrictedtoarangeofheightsoffrom1mto4mabovethegroundor referencegroundplane. 7.Whentheradiatedemissionslimitsareexpressedintermsoftheaveragevalueoftheemissions,and pulsedoperationisemployed,themeasurementfieldstrengthshallbedeterminedbyaveragingoverone completepulsetrain,includingblankingintervals,aslongasthepulsetraindoesnotexceed0.1seconds. ReportNo.:AGC09355260102FR01 Page49of63 8.Asanalternative(providedthetransmitteroperatesforlongerthan0.1seconds)orincaseswherethe pulsetrainexceeds0.1seconds,themeasuredfieldstrengthshallbedeterminedfromtheaverage absolutevoltageduringa0.1secondintervalduringwhichthefieldstrengthisatitsmaximumvalues. 9.IftheemissionsleveloftheEUTinpeakmodewas3dBlowerthantheaveragelimitspecified,then testingwillbestoppedandpeakvaluesofEUTwillbereported,otherwise,theemissionswhichdonot have3dBmarginwillberepeatedonebyoneusingthequasi-peakmethodforbelow1GHz. 10.Fortestingabove1GHz,theemissionsleveloftheEUTinpeakmodewaslowerthanaveragelimit(that meanstheemissionslevelinpeakmodealsocomplieswiththelimitinaveragemode),thentestingwillbe stoppedandpeakvaluesofEUTwillbereported,otherwise,theemissionswillbemeasuredinaverage modeagainandreported. 11.Incasetheemissionislowerthan30MHz,loopantennahastobeusedformeasurementandtherecorded datashouldbeQPmeasuredbyreceiver.High-Lowscanisnotrequiredinthiscase. Thefollowingtableisthesettingofspectrumanalyzerandreceiver. SpectrumParameterSetting Start~StopFrequency9kHz~150kHz/RB200HzforQP Start~StopFrequency150kHz~30MHz/RB9kHzforQP Start~StopFrequency30MHz~1000MHz/RB120kHzforQP Start~StopFrequency 1GHz~26.5GHz 1MHz/3MHzforPeak,1MHz/3MHzforAverage ReceiverParameterSetting Start~StopFrequency9kHz~150kHz/RB200HzforQP S…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Carry Xu
[email protected]Fax: +86-0760-88269939

Technical Contact

Wedo GroupJeffrey Chen
[email protected]

710 Arabian Ln · Walnut, 91789 · United States

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Zhongshan Camry Electronic Co.,LTD.

Smart Body Fat Scale - FCC ID Q22-IF1131D - Zhongshan Camry Electronic Co.,LTD.
Q22-IF1131D

Smart Body Fat Scale

Aug 11, 2024

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID Q22-IF1090D - Zhongshan Camry Electronic Co.,LTD.
Q22-IF1090D

Smart Body Fat Scale

Jul 18, 2024

Equipment Class

DTS - Digital Transmission System
Q22-IF2825A

Smart Body Fat Scale

Apr 10, 2024

Equipment Class

DTS - Digital Transmission System
Smart Body Fat Scale - FCC ID Q22-IF2802A - Zhongshan Camry Electronic Co.,LTD.
Q22-IF2802A

Smart Body Fat Scale

Oct 08, 2023

Equipment Class

DTS - Digital Transmission System
Bluetooth Body Scale - FCC ID Q22IB931B - Zhongshan Camry Electronic Co.,LTD.
Q22IB931B

Bluetooth Body Scale

Jun 03, 2015

Equipment Class

DTS - Digital Transmission System