FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Schulte-Schlagbaum AG/
  3. Q3ISOT02

Q3ISOT02Inductive Tag Reader

Schulte-Schlagbaum AG
Inductive Tag Reader - FCC ID Q3ISOT02 - Schulte-Schlagbaum AG
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Nov 17, 2004
Application Purpose
Original Equipment
Date of Application
Nov 17, 2004
Equipment Note
Inductive Tag Reader
Frequency Range
0.12500000 - 0.12500000
Company
Schulte-Schlagbaum AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALLATION final public 2004-10-05 SOT-manual.DOC Cabinet Lock SAFE-O-TRONIC up from Firmware 4.00 (with real time clock) (1) (2) Fig. 1: SAFE-O-TRONIC layout right (layout left = mirror image) (1) Recommended door hole diameter 23 mm (2) max. door thickness 21.5 mm SAGSAFE-O-TRONICInstallation Schulte- Schlagbaum AGPage 2 of 14SOT-manual.DOC Note  Copyright 1998 - 2004 by Schulte-Schlagbaum AG Nevigeser Straße 100 D-42553 Velbert Tel.: +49 20512086155 With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. Schulte- Schlagbaum AG does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. Schulte-Schlagbaum AG does not give any guarantee promise for perfect function in cross environments. Schulte-Schlagbaum AG assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. Schulte-Schlagbaum AG does not convey any license under its patent rights nor the rights of others. SAGSAFE-O-TRONICInstallation Schulte- Schlagbaum AGPage 3 of 14SOT-manual.DOC Contents 1. Safety and warning notices – read before commissioning............................................4 2. Basic functions of the SAFE-O-TRONIC..............................................................................5 2.1. Locking the SAFE-O-TRONIC.............................................................................................5 2.2. Unlocking the SAFE-O-TRONIC..........................................................................................5 3. Installation....................................................................................................................................6 4. Start-up procedure....................................................................................................................6 4.1. Function testing with the "TestKey"......................................................................................6 4.2. Configuring the SAFE-O-TRONIC with the "SetupKey"...................................................7 4.3. Configuring for standard/daylight saving time "DSTKey"..................................................8 4.4. . Setting time of day and date "ClockSetKey".....................................................................8 5. Resetting a SAFE-O-TRONIC with the "ResetKey"........................................................10 6. Replacing a SAFE-O-TRONIC...............................................................................................10 7. Battery.........................................................................................................................................11 7.1. Battery replacement.............................................................................................................11 8. Service / Maintenance.............................................................................................................11 ANNEX A Technical Data............................................................................................................12 ANNEX B:........................................................................................................................................13 Europe (CE)..................................................................................................................................13 USA (FCC)....................................................................................................................................13 ANHANG C: LED Blink-Codes...................................................................................................14 SAGSAFE-O-TRONICInstallation Schulte- Schlagbaum AGPage 4 of 14SOT-manual.DOC 1. Safety and warning notices – read before commissioning • The device may only be used for the purpose intended by the manufacturer. • The operating instructions have to be handed out to every user and kept in an easily accessible place. • Unacceptable changes as well as the use of spare parts and special features which are not sold or recommended by the manufacturer, may cause fire, electric shocks and injuries. Therefore, such measures lead to nonliability of the manufacturer and a lapse of all warranty claims. • The appliance is subject to the manufacturer’s guarantee regulations in the version valid at the time of purchase. We cannot be held liable for improper or faulty manual or automatic adjust- ment of parameters resp. improper use of the appliance. • Repair work may only be carried out by the manufacturer. • The user has to make sure that the appliance is installed and operated according to the techni- cal rules of the country of installation as well as other regional regulations. SAGSAFE-O-TRONICInstallation Schulte- Schlagbaum AGPage 5 of 14SOT-manual.DOC 2. Basic functions of the SAFE-O-TRONIC (1) Rotary knob: With integrated LED display (red / green) and antenna for exchange between SAFE-O-TRONIC and megaKey. (2) Battery compartment: Use special screwdriver to open (Type: ID MS.SSD-A). 2.1. Locking the SAFE-O-TRONIC 1. Push rotary knob SAFE-O-TRONIC is activated for 8 sec. (no indicator) 2. Present megaKey: The green LED flashes for a max. of 8 sec.…

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidentiality 16 November 2004 PHOENIX TEST-LAB GmbH Königswinkel 10 D32825 Blomberg Germany RE: Certification Application FCC ID: Q3ISOT02 Please be advised that the following information is to be held confidential on behalf of Schulte- Schlagbaum AG • Schematics • Parts Lists • Block Diagram • Technical Description The application contains technical information which Schulte-Schlagbaum AG deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Signatory

External Photos

EMV-Pr ̧fzentrum EMI/EMC-Testcenter EMV-Pr ̧fzentrum EMI/EMC-Testcenter

ID Label/Location Info

EMV-Pr ̧fzentrum EMI/EMC-Testcenter

Internal Photos

EMV-Pr ̧fzentrum EMI/EMC-Testcenter EMV-Pr ̧fzentrum EMI/EMC-Testcenter EMV-Pr ̧fzentrum EMI/EMC-Testcenter EMV-Pr ̧fzentrum EMI/EMC-Testcenter EMV-Pr ̧fzentrum EMI/EMC-Testcenter

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 50602-40686-3b (Edition 1) Page 1 of 26 Pages Straubing, October 28, 2004 T E S T - R E P O R T No. 50602-40686-3b for SAVE-O-TRONIC Electronic Locking Lock Applicant: Schulte-Schlagbaum AG Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207 and 15.209 Industry Canada Radio Standards Specification RSS-210 Issue 5, Sections 6.2.1, 6.3 and 6.6 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 2 of 26 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measuring Methods .................................................................................................... 8 6.1 Conducted AC powerline emission....................................................................... 8 6.2 Radiated Emission Measurement 9 kHz ñ 30 MHz .............................................. 9 6.3 Radiated emission in Fully Anechoic Room ....................................................... 11 6.4 Radiated emission at Open Field Test Site ........................................................ 13 7 Photographs Taken During Testing .......................................................................... 14 8 List of Measurements ............................................................................................... 18 9 Referenced Regulations ........................................................................................... 25 10 Charts taken during testing ....................................................................................... 26 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 3 of 26 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : SAVE-O-TRONIC Parts 2 : --- Serial number(s): 01 Manufacturer: Schulte-Schlagbaum AG Type of equipment: Electronic Locking Lock Version: As delivered FCC ID: Q31SOT02 Additional parts/accessories: Tag 04FEBOH47 Technical data of EUT Application frequency range: Not applicable 3 Frequency range: 125 kHz Operating frequency: 125 kHz Type of modulation: ASK Pulse train: 373 ms Pulse width: 65.4 ms Number of RF-channels: 1 Channel spacing: Not applicable Class of emission: 5k00A1D Type of antenna: Coil antenna Size/length of antenna: Dimensions of coil: 15 x 17 x 7 mm Number of loops: 280 Type of power supply: Battery supply Specifications for power supply: nominal voltage: 6.0 V minimum voltage: 5.5 V maximum voltage: 6.0 V nominal frequency: --- Hz 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 General requirements according to CFR 47 Part 15 section 15.209 apply. Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 4 of 26 Pages 2 Administrative Data Application details Applicant (full address): Schulte-Schlagbaum AG Nevigeser Strafle 100 D-42553 Velbert Germany Contact person: Mr. Helmut Guth Contract identification: --- Receipt of EUT: October 4, 2004 Date(s) of test: October 2004 Note(s): --- Report details Report number: 50602-40686-3b Edition: 1 Issue date: October 28, 2004 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 5 of 26 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory Accreditation: DAR-Registration No. DAT-P-171/94-02 FCC Test Site registration number 90926 Industry Canada Test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 6 of 26 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 15, Sections 15.205, 15.207 and 15.209 of the Federal Communication Commission (FCC) and the Radio Standards Specification RSS-210 Issue 5, Sections 6.2.1, 6.3 and 6.6 (Category I Equipment) of Industry Canada (IC). Personnel involved in this report Laboratory Manager: Mr. Johann Roidt Responsible for testing: Mr. Martin Steindl Responsible for test report: Mr. Martin Steindl Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 7 of 26 Pages 5 Operation Mode and Configuration of EUT Operation Mode Reading transponder continuously. Configuration of EUT EUT is configured to transmit continuously, when a transponder is found within 5 seconds after activation. List of ports and cables Port Description Classification 4 Cable type Cable length Not Applicable List of devices connected to EUT Item Description Type Designation Serial no. or ID Manufacturer Not Applicable 4 Ports shall be classified as ac power, dc power or signal/control port Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) …

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 15 of 26 Pages Test setup for radiated emission test (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 16 of 26 Pages Test setup for radiated emission test (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-40686-3b (Edition 1) Page 17 of 26 Pages

Contact Information

Applicant

Helmut Guth(QC Manger)
[email protected]+49 2051 2086

Technical Contact

Senton GmbHJohann Roidt
[email protected]+49 9421 55 22 13

Aeussere Fruehlingstrasse 45 · Straubing · Germany

Non-Technical Contact

Senton GmbHJohann Roidt
[email protected]+49 9421 55 22 13

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Schulte-Schlagbaum AG

Inductive Reader SAFE-O-TRONIC - FCC ID Q3ISOT01 - Schulte-Schlagbaum AG
Q3ISOT01

Inductive Reader SAFE-O-TRONIC

Jun 16, 2003

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz