FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Echometer Company/
  3. Q5Q-WB100

Q5Q-WB100Base unit equipped with 802.15.4 radios

Echometer Company
Base unit equipped with 802.15.4 radios - FCC ID Q5Q-WB100 - Echometer Company
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 09, 2012
Application Purpose
Original Equipment
Date of Application
Oct 07, 2012
Equipment Note
Base unit equipped with 802.15.4 radios
Frequency Range
2405.00000000 - 2480.00000000
Company
Echometer Company
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Base User Guide Echometer Company 5001 Ditto Lane Wichita Falls, TX 76302 11 Sep 2012 This manual pertains to the Echometer Wireless Base WB100. Associated FCC and IC identification numbers are provided in Table 1, with label image and location images in Table 2. Model FCCID IC ID Wireless Base Model WB100 Q5Q-WB100 10048A-WB100 Table 1 FCC/IC Label Design/Location FCC/IC Label Location Table 2: Label shown will be placed on the bottom of the product enclosure Wireless Base User Guide Echometer Company 5001 Ditto Lane Wichita Falls, TX 76302 11 Sep 2012 The Wireless Base WB100 is a component of the Echometer Well Analyzer and designed to be used with Echometer Wireless Sensors, (WRFG, WPRT, WPP, WPT, WHT, WHT50K, and WGDA), providing a wireless option for obtaining data, (such as dynamometer, power and pressure/temperature). The data is analyzed by the Echometer TAM software and utilized to provide analysis of well performance. Please refer to the Echometer TAM User Manual for instruction specific to software operation and to Echometer Wireless Sensor User Guide for instructions specific to those devices. Wireless Base User Guide Echometer Company 5001 Ditto Lane Wichita Falls, TX 76302 11 Sep 2012 • WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user’s expense. • This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the antenna and your body. • This Class A digital apparatus complies with Canadian ICES-003. (Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada) • This device has been designed to operate with the antennas listed below. The specific models listed or substitutes as specified below may be used. o Pulse W1030 o Linx Tech ANT-2.4-CW-RAH-RPS: 2.4GHz o Substitutes may be used, as long as they meet the 2.4GHz, 50Ω, <2dBi gain, RPSMA Male requirements. Wireless Base User Guide Echometer Company 5001 Ditto Lane Wichita Falls, TX 76302 11 Sep 2012 Wireless Base WB100 Installation: 1. Connect antennae to the WB100 as shown: 2. A backup battery (+5-15VDC ) may be connected to the WB100 using the power connector shown: 3. Connect the supplied USB cable between the Echometer Computer and the WB100 USB port. 4. Proceed with setup using the Echometer TAM Software User Manual.

ID Label/Location Info

1.905 3.200 R.100 .025 5 4 3 2 1 DRAWN BY: MATERIAL Plastic w/ Adhesive DATE INITIALS ECHOMETER TITLE: SIZE A DWG. NO. REVISION: 0 SCALE: 1:1 UNLESS OTHERWISE SPECIFIED: DO NOT SCALE DRAWING DIMENSIONS ARE IN INCHES TOLERANCES: FRAC. 1/32 .XX .01 .XXX .005 .XXXX .0005 ANG. .5 JBW 09-11-12 SHEET 1 OF 1 WBA-0010-001 FCC LABEL PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING WAS GENERATED ON BEHALF OF JERRY WEST, LLC CLIENT, ECHOMETER. THIS DRAWING IS THE SOLE PROPERTY OF ECHOMETER. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF ECHOMETER IS PROHIBITED. FINISH None CLIENT: (((ECHOMETER))) MODEL WB100 WIRELESS SYSTEM BASE STATION FCC ID:Q5Q-WB100 IC:10048A-WB100 www.echometer.com ECHOMETER COMPANY Wichita Falls, TX This device complies with part 15 of the FCC rules. Operation is subject to the folloowing two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Info

1. ANT-2.4-CW-RAH-xxx Radiation Patterns (at Edge of Jig #50-V2) 2. Chamber

RF Exposure Info

Wireless External Antenna for 2.4 GHz Applications Pulse Part Number: W1030 © 2007 All Rights Reserved. W1030 Datasheet Version 1.1. September 2007 Feat ures - Shortest antennas in product lin e - For WLAN devices using WiFi (802.11b/g), Bluetooth® and ZigBee TM - Omni-directional radiation patte rn provides broad 360° coverage - One-quarter wavelength dipole confi guratio n - Connection options easily integrate with OEM designs Connector Option s - Reverse SMA (Male)* - SMA (Male) * Default Configuration – Please contact Pulse Applications Engineering for assistance in ordering connectors Weight........................................................6.3 grams Carton...........................................20/bag; 500/carton Dimensions: Inches mm Unless otherwise specified, a ll to lerances are ± .010 0.25 Frequency [GHz] VSWR Length Impedance [Nom] ≤ 2. 01/4, dipole50 Ω Electrical Specifications @ 25 ºC Note: This par t number is lead- free and RoHS compliant. N o additional suffix or identifier is required. Gain [dBi] 2.0 Radiatio n Omni Polarization Vertic al Antenna Part No. W1030 Pulse Antennas Takatie 6 90440 K empele Finland Tel: +358 207 935 500 www.pulseeng.com/antennas Exte rnal Antennas Sal es Contacts USA858 674 8100 UK44 1483 401 700 France33 3 84 35 04 04 Singapore65 6287 8998 Shanghai86 21 32181071 China86 769 5538070 Taiwan886 2 26980228 Electrical Wireless External Antenna for 2.4 GHz Applications Pulse Part Number: W1030 © 2007 All Rights Reserved. W1030 Datasheet Version 1.1. September 2007 Vertical Posi tion Horizontal Posi tion Gain Performance W1030 Omni-directional antennas provide a uniform, donut- shaped, 360° radiation pattern. The omni-directional pattern is suitable for point-to-multipoint broadcasting in all directions. This antenna is primarily used for WLAN applications. However, it can also be used for a variety of other applications within the specified frequency range. When used as an access point, th e antenna is ideally located at the center of the coverage ar ea. Application Notes Pulse Antennas Takatie 6 90440 K empele Finland Tel: +358 207 935 500 www.pulseeng.com/antennas Exte rnal Antennas Sales Contacts USA858 674 8100 UK44 1483 401 700 France33 3 84 35 04 04 Singapore65 6287 8998 Shanghai86 21 32181071 China86 769 5538070 Taiwan886 2 26980228

RF Exposure Info

§ 15.247(i) Maximum Permissible Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 2405-2480 MHz; highest conducted power = 4.68 dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 2 dBi. Worst case configuration is being evaluated: the power is doubled to account for two radios simultaneously on same channel (this device will never transmit simultaneously on same channels) Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (1 mW/cm 2 ) P = Combined Power Input to antenna (5.88 mW) G = Antenna Gain (1.58 numeric) S = (5.88*1.58/ 4*3.14*20^2) = 0.002 mW/cm2 So the exposure limit is met at 20 cm.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory September 28, 2012 TenX Precision, LLC 11824 Jollyville Road, Suite 102 Austin, Texas 78759 Dear Daraius Hathiram, Enclosed is the EMC Wireless test report for compliance testing of the TenX Precision, LLC, Echometer Wireless Base as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15 Subpart C and RSS-210, Issue 8, Dec. 2010 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\TenX Precision, LLC\EMCA33149A-FCC247 Rev. 3) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility TenX Precision, LLC Cover Page Echometer Wireless Base CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCA33149A-FCC247 Rev. 3 © 2012, MET Laboratories, Inc. Page ii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the TenX Precision, LLC Echometer Wireless Base Tested under the FCC Certification Rules contained in Title 47 of the CFR, Part 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators MET Report: EMCA33149A-FCC247 Rev. 3 September 28, 2012 Prepared For: TenX Precision, LLC 11824 Jollyville Road, Suite 102 Austin, Texas 78759 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 Electromagnetic Compatibility TenX Precision, LLC Cover Page Echometer Wireless Base CFR Title 47, Part 15B, 15.247; RSS-210, Issue 8, Dec. 2010 & ICES-003 MET Report: EMCA33149A-FCC247 Rev. 3 © 2012, MET Laboratories, Inc. Page iii of viii DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the TenX Precision, LLC Echometer Wireless Base Tested under the FCC Certification Rules contained in Title 47 of the CFR, Part 15.247 Subpart C & RSS-210, Issue 8, Dec. 2010 for Intentional Radiators Dusmantha Tennakoon Jennifer Warnell Project Engineer, Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Part 15.247 and Industry Canada standard RSS-210, Issue 8, Dec. 2010 under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility TenX Precision, LLC Report Status Echometer Wireless Base CFR Title 47, Part 15.247; RSS-210, Issue 8, Dec. 2010 MET Report: EMCA33149A-FCC247 Rev. 3 © 2012, MET Laboratories, Inc. Page iv of viii DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision  December 19, 2011 Initial Issue. 1 September 12, 2012 Revised to reflect engineer corrections. 2 September 26, 2012 Revised to reflect engineer corrections. 3 September 28, 2012 Revised MPE per engineer corrections. Electromagnetic Compatibility TenX Precision, LLC Table of Contents Echometer Wireless Base CFR Title 47, Part 15.247; RSS-210, Issue 8, Dec. 2010 MET Report: EMCA33149A-FCC247 Rev. 3 © 2012, MET Laboratories, Inc. Page v of viii DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................6 E. Equipment Configuration ....................................................................................................................................6 F. Support Equipment .............................................................................................................................................6 G. Ports and Cabling Information ............................................................................................................................6 H. Mode of Operation ...................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ! UNION CITY, CALIFORNIA 94587 ! PHONE (510) 489-6300 ! FAX (510) 489-6372 3162 BELICK STREET ! SANTA CLARA, CA 95054 ! PHONE (408) 748-3585 ! FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory TenX Precision, LLC November 22, 2011 11824 Jollyville Road, Suite 102 Austin, Texas 78759 Dear Daraius Hathiram, Enclosed is the EMC test report for compliance testing of the TenX Precision, LLC, Echometer Wireless Base, tested to the requirements of Title 47 of the Code of Federal Regulations (CFR), Part 15 Subpart B, Section 15.101(a) and ICES-003, Issue 4 February 2004. Based on these results, MET Laboratories, Inc. certifies that the Echometer Wireless Base, tested as configured, meets the requirements and interference limitations for a Class A Digital Devices under Title 47 of the CFR, Part 15 Subpart B, Section 15.107(a) and 15.109(a) and ICES-003, Issue 4 February 2004. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\TenX Precision, LLC\EMCA33149-FCC) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. This letter of transmittal is not a part of the attached report. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ! UNION CITY, CALIFORNIA 94587 ! PHONE (510) 489-6300 ! FAX (510) 489-6372 3162 BELICK STREET ! SANTA CLARA, CA 95054 ! PHONE (408) 748-3585 ! FAX (510) 489-6372 13301 MCCALLEN PASS ! AUSTIN, TX 78753 ! PHONE (512) 287-2500 ! FAX (512) 287-2513 DOC-EMC707 8/22/2008 Electromagnetic Compatibility Criteria Test Report For the TenX Precision, LLC Echometer Wireless Base Title 47 of the Code of Federal Regulations (CFR), Part 15 Subpart B & ICES-003 for a Class A Digital Device MET Report: EMCA33149-FCC November 22, 2011 Prepared for: TenX Precision, LLC 11824 Jollyville Road, Suite 102 Austin, Texas 78759 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 TenX Precision, LLC Electromagnetic Compatibility Echometer Wireless Base CFR Title 47, Part 15, Subpart B & ICES-003 MET Report: EMCA33149-FCC © 2011, MET Laboratories, Inc. Page ii of vi DOC-EMC707 8/22/2008 Electromagnetic Compatibility Criteria Test Report For the TenX Precision, LLC Echometer Wireless Base Title 47 of the Code of Federal Regulations (CFR), Part 15 Subpart B & ICES-003 for a Class A Digital Device MET Report: EMCA33149-FCC Dusmantha Tennakoon Jennifer Warnell Project Engineer, Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the applicable limits. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Title 47 of the CFR, Part 15, Subpart B and Industry Canada standards ICES-003, Issue 4 February 2004 for a Class A Digital Device under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab TenX Precision, LLC Electromagnetic Compatibility Echometer Wireless Base CFR Title 47, Part 15, Subpart B & ICES-003 MET Report: EMCA33149-FCC © 2011, MET Laboratories, Inc. Page iii of vi DOC-EMC707 8/22/2008 Report Status Sheet Revision Report Date Reason for Revision Ø November 22, 2011 Initial Issue. TenX Precision, LLC Electromagnetic Compatibility Echometer Wireless Base CFR Title 47, Part 15, Subpart B & ICES-003 MET Report: EMCA33149-FCC © 2011, MET Laboratories, Inc. Page iv of vi DOC-EMC707 8/22/2008 Table of Contents 1.0 Testing Summary ........................................................................................................................................................ 1 2.0 Equipment Configuration........................................................................................................................................... 2 2.1 Overview ................................................................................................................................................................. 2 2.2 Test Site .................................................................................................................................................................. 3 2.3 Description of Test Sample ..................................................................................................................................... 3 2.4 Equipment Configuration ........................................................................................................................................ 3 2.5 Support Equipment ................................................................................................................................................. 3 2.6 Ports and Cabling Information ................................................................................................................................ 4 2.7 Mode of Operation .................................................................................................................................................. 4 2.8 Modifications ..............…

Text truncated - open the document above for the full version.

Test Setup Photos

Photograph 1. Conducted Emissions, 15.207(a), Test Setup Photograph 2. Radiated Spurious Emissions, Test Setup, Below 1 GHz Photograph 3. Radiated Spurious Emissions, Test Setup, 1 GHz – 18 GHz Photograph 4. Radiated Spurious Emissions, Test Setup, 18 GHz – 26 GHz

Contact Information

Applicant

Dieter Becker(Engineeer)
[email protected]9407674334Fax: 9407237507

Technical Contact

Echometer CompanyDieter J. Becker
[email protected]940-737-4334

5001 Ditto Lane · Wichita Falls, Texas · United States

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.90 mW
Confidentiality
Long Term
Grant Notes
Power is listed as conducted.

Other Applications from Echometer Company

Q5Q-WRFG200

Wireless Sensor System

Sep 15, 2025

Equipment Class

DTS - Digital Transmission System
Echometer wireless sensor - FCC ID Q5Q-WRFG - Echometer Company
Q5Q-WRFG

Echometer wireless sensor

Jan 27, 2013

Equipment Class

DTS - Digital Transmission System
Echometer Wireless Sensor - FCC ID Q5Q-WS - Echometer Company
Q5Q-WS

Echometer Wireless Sensor

Oct 09, 2012

Equipment Class

DTS - Digital Transmission System