FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Carrin Electronics Co., Ltd./
  3. Q9E-91166

Q9E-91166Wireless Thermometer

Carrin Electronics Co., Ltd.
Wireless Thermometer - FCC ID Q9E-91166 - Carrin Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 25, 2003
Application Purpose
Original Equipment
Date of Application
Sep 25, 2003
Equipment Note
Wireless Thermometer
Frequency Range
433.95600000 - 433.95600000
Company
Carrin Electronics Co., Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166

External Photos

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 (1) EUT top view (2) EUT bottom view

ID Label/Location Info

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 Proposed Label Location on EUT EUT Bottom View/Proposed FCC ID Location FCC ID: Q9E-91166

Internal Photos

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 (3) EUT inside whole view (4) Main board component side (5) Main board solder side

Operational Description

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 91166 Operational Description This is a LCD display thermometer for household application. The unit use 2 pcs of 1.5V battery in-series connection give 3V supply. Devices operated under the provisions of this paragraph shall be provided with a means for auto- matically limiting operation so that the duration of each transmission shall be at least 30 times the duration of the transmission. The function of the 91166Tx is to regularly measure its surrounding temperature at its point of location and transmit the data using wireless 433MHz to a standing alone receiving unit. The data would them be displayed on the receiving units LCD. For all description please read the enclosed user instruction manual.

Schematics

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166

Test Report

The test report consists 22 pages in total. It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Ke Mei Ou Laboratory Corporation. The test result in the report only applied to the tested sample. FCC TEST REPORT UNDER FCC 15 Subpart C, Paragraph 15.231 Prepared For : Carrin Electronics Co., Ltd. Unit 1308, Tower A, Regent Centre, 63 Wo Yi Hop Road, Kwai Chung, N.T., Hong Kong September 19, 2003 FCC ID: Q9E-91166 EUT: Wireless Thermometer Model: 91166 Report Type: Original Report Test Engineer: Peter Lin Test Date: September 17, 2003 Review By: Apollo Liu / Manager FEDERAL COMMUNICATIONS COMMISSION Registration Number: 125782 Ke Mei Ou Laboratory Co., Ltd. 7A, Jiaxiangge, Jiahuixincheng, No.3027, Shennan Rd., Futian, Shenzhen, Guangdong, P.R.China. Zip Code: 518033 Tel: + 86 755 83642690 Fax: + 86 755 83297077 www.kmolab.com Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 FCC ID Report Report #: KSZ2003091602J Page 2 of 2 TABLE OF CONTENTS 1. General Information...........................................................................................................................................................3 1. 1 Notes...............................................................................................................................................................................3 1. 2 Testing Laboratory..........................................................................................................................................................3 1. 3 Details of Applicant........................................................................................................................................................3 1. 4 Application Details.........................................................................................................................................................3 1. 5 Test Item.........................................................................................................................................................................3 1. 6 Test Standards.................................................................................................................................................................4 2. Technical Test.......................................................................................................................................................................5 2. 1 Summary of Test Results................................................................................................................................................5 3. EUT Modifications..............................................................................................................................................................6 4. Conducted Power Line Test................................................................................................................................................7 4. 1 Test Equipment...............................................................................................................................................................7 4. 2 Test Procedure................................................................................................................................................................7 4. 3 Test Setup.......................................................................................................................................................................7 4. 4 Configuration of The EUT..............................................................................................................................................8 4. 5 EUT Operating Condition...............................................................................................................................................9 4. 6 Conducted Power Line Emission Limits........................................................................................................................9 4. 7 Conducted Power Line Test Result...............................................................................................................................10 5. Radiated Emission Test......................................................................................................................................................11 5. 1 Test Equipment.............................................................................................................................................................11 5. 2 Test Procedure..............................................................................................................................................................11 5. 3 Radiated Test Setup......................................................................................................................................................11 5. 4 Configuration of The EUT............................................................................................................................................12 5. 5 EUT Operating Condition.............................................................................................................................................12 5. 6 Radiated Emission Limit..............................................................................................................................................12 5. 7 Radiated Emission Test Result......................................................................................................................................13 6. Band Edge..........................................................................................................................................................................14 6. 1 Test Equipment....................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Applicant: Carrin Electronics Co., Ltd. FCC ID: Q9E-91166 Radiated emission test view

Contact Information

Applicant

Jianxin Li(General Manager)
[email protected]+(852) 2418 2262Fax: +(852) 2489 0703

Test Firm

Ke Mei Ou Laboratory Co., Ltd.Apollo Liu
[email protected]86-755-83642690Fax: 86-755-83297077

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)433.956 MHz - 433.956 MHz-

Other Applications from Carrin Electronics Co., Ltd.

LCD Thermo Sensor - FCC ID Q9E-91527 - Carrin Electronics Co., Ltd.
Q9E-91527

LCD Thermo Sensor

Aug 15, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Thermometer Station with Wireless Outdoor Sensor - FCC ID Q9E-ART80 - Carrin Electronics Co., Ltd.
Q9E-ART80

Thermometer Station with Wireless Outdoor Sensor

Jun 14, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Thermometer - FCC ID Q9E-KW5012 - Carrin Electronics Co., Ltd.
Q9E-KW5012

Wireless Thermometer

Sep 16, 2003

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
WIRELESS THERMOMETER - FCC ID Q9E-91465 - Carrin Electronics Co., Ltd.
Q9E-91465

WIRELESS THERMOMETER

Jul 27, 2003

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter