QB3CORECESS3213NVDSL Modem

Corecess Inc.
VDSL Modem - FCC ID QB3CORECESS3213N - Corecess Inc.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Nov 24, 2003
Application Purpose
Original Equipment
Date of Application
Nov 24, 2003
Equipment Note
VDSL Modem
Company
Corecess Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

| FCC Part 15 Notice | This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class B limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is not guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: โ€ข Reorient the receiving antenna. โ€ข Increase the separate between the equipment and the receiver. โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. โ€ข Consult the dealer or an experienced radio/TV technician for help. | Copyright | Copyright โ“’ Corecess All rights Reserved. No Part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from the publisher. The specifications and information regarding the products in this manual are subject to changed without notice. | Trademark Credit | Corecess 3311N and Corecess 3312N are registered trademark of Corecess Inc. Windows is registered trademark of Microsoft Corp. Corecess Inc. 997-4, Daechi-dong, Kangnam-ku, Seoul, Korea TEL:82-2-3016-6900 FAX:82-2-3016-6622 http://www.corecess.com Table of Contents Introduction ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 Before Installing ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 Installing the SHDSL Modem ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 Configuring the TCP/IP ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 Troubleshooting ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 Product Specifications ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 Thank you for using the product of Corecess. This manual helps users to install the Corecess SHDSL Modem Corecess 3311N and Corecess 3312N. Corecess 3311N/3312N Installation Guide 4 Introduction The Corecess 3311N and Corecess 3312 N are Single-pair High-speed Digital Subscriber Line (SHDSL) modems used for connection to the Internet or corporate intranets over ordinary telephone lines. Key Features The Corecess 3311N and Corecess 3312N SHDSL modem provides the following key features: y Provides auto-negotiating 10/100Base-TX Ethernet interface. y Provides SHDSL interface supporting the following data transmission rate: - Corecess 3311N : up to 2.3 Mbps for both upstream and downstream (2-wire mode) - Corecess 3312N : up to 4.6 Mbps for both upstream and downstream (4-wire mode) y Supports both symmetric and asymmetric services. y Supports both adaptive and fixed data rate modes. y Supports both server (CO) and client (CPE) operation modes. y Supports PPPoE, PPPoA, IPoA, RFC 1483 bridged/routed protocols. y Supports static routing and dynamic routing (RIP v1 and RIP v2) y Supports DHCP (Dynamic Host Configuration Protocol) server and client for dynamic IP address allocation. y Supports DNS (Domain Name Server) client and relay for easy mapping the domain name and IP address. y Supports NAT (Network Address Translation) for conservation of registered IP addresses. y Supports Telnet and HTML browser interface for configuring the SHDSL modem. y Can upgrade the latest modem software remotely using TFTP or FTP. y Supports Back-to-Back Connections for high-speed LAN extensions over a private network. 5 Before Installing Safety Precautions When installing or using the SHDSL modem, the following safety precautions should always be followed. y Do not use the SHDSL modem near water, for example, near a bath tub, wash bowl, kitchen sink of laundry tub, in a wet basement or near a swimming pool. y Use caution when installing or modifying telephone lines to prevent electric shock. y Do not connect or disconnect telephone lines during periods of lightning activity. y Use only the power supply and power cord provided with the SHDSL modem. Unpacking the Box Check the shipping carton carefully to ensure that the contents include the items you ordered. Note: The PC with a Ethernet port or adapter is neccssary to install the SHDSL modem. Before installing the SHDSL modem, prepare a PC with Ethernet port or adapter. Caution: To reduce the risk of fire, use only No. 26AWG or larger telecommunication line cord. Installation Guide SHDSL Modem Ethernet Cable (Straight-through Category-5) SHDSL Cable (4-wire Telephone Line) Power Supply and Power Cord Corecess 3311N/3312N Installation Guide 6 Installing the SHDSL Modem n Connect the provided SHDSL cable to the wall receptacle and connect the other end of the cable to the LINE port of the SHDSL modem. o Connect the provided Ethernet cable to the LAN port of the SHDSL modem and then connect the other end of the cable to Ethernet port on the NIC installed to your PC. p Connect the provided power supply cable into the DC IN port of the SHDSL modem. q Connect the provided power cord to the power supply and connect the other end of the cord to an appropriate electrical outlet. r Turn on the SHDSL modem with the power switch on the rear panel of the SHDSL modem. s Power on your PC. Caution: You should power on the SHDSL modem before powering on your PC. If you power on your PC first, PCโ€™s IP address may not be properly assigned. In this case, assign new IP address referring to โ€˜Troubleshootingโ€™ on page 10-11 or restart your PC.โ€ฆ

Text truncated - open the document above for the full version.

Block Diagram

M II PEF 2 2 8 2 2 V DS L PUM P A C101L Ethernet PHY RJ-11 PO R (TEL PEB 22811 VDSL- A T24C6 A PC77124 VDSL FILTE B4010POTD/ISSPLITT RJ-45 PO R PEB 22810 V DSL- DATA RJ-11 PO R (LINE X-TAL (25M Hz ) PEB22811 P E F22822 AC101L 25 MHz 25 MHz

Cover Letter(s)

1 Mike Kuo From: ldy [[email protected]] Sent: November242003Monday 11:54 PM To: Mike Kuo Subject: Re: [TCB] Corecess 3213N / Corecess Inc / VDSL Modem test-setup.pdf [01/10] BlockDiagram.pdfCC3213N manual.pdf external.pdfinternal.pdflabel.pdfreport.pdftest-setup.pdf Dear Mike Kuo Thank you for your cooperation. I am sorry for my mistake. Please see the attached file. This project is very urgent. If you possible, please send me TCB Approval sheet in today. I'm sorry. Best Regards. Brucelim. ----- Original Message ----- From: "Mike Kuo" <[email protected]> To: "'ldy'" <[email protected]> Sent: Tuesday, November 25, 2003 12:18 PM Subject: RE: [TCB] Corecess 3213N / Corecess Inc / VDSL Modem test-setup.pdf [01/10] > Hi Bluce : > > Question #1: User manual does not contain information required under > section 15.21 of FCC rules. Please provide revised user manual to comply > this requirement. > > Question #2: Please provide internal photo of AC/DC adapter. > > Best Regards > > Mike Kuo > > > -----Original Message----- > > From: ldy [mailto:[email protected]] > > Sent: Monday, November 24, 2003 5:17 PM 2 > > To: Mike Kuo > > Subject: Fw: [TCB] Corecess 3213N / Corecess Inc / VDSL Modem test- > > setup.pdf [01/10] > > Importance: High > > > > << Message: Untitled Attachment >> << File: report.pdf >>

External Photos

CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK EUT External Photographs Test Report No.: CTK03-F111 Date: November 5, 2003 Page 1 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK Test Report No.: CTK03-F111 Date: November 5, 2003 Page 2 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2

ID Label/Location Info

CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK Photographs related to Label Test Report No.: CTK03-F111 Date: November 5, 2003 Page 1 of 1 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2

Internal Photos

CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK EUT Internal Photographs Test Report No.: CTK03-F111 Date: November 5, 2003 Page 1 of 3 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK PCB Test Report No.: CTK03-F111 Date: November 5, 2003 Page 2 of 3 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK Test Report No.: CTK03-F111 Date: November 5, 2003 Page 3 of 3 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2

Test Setup Photos

CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK APPENDIX B - Test Setup Photos and Configuration Conducted Voltage Emissions Test Report No.: CTK03-F111 Date: November 5, 2003 Page 1 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2 CERTiTEK Standards Laboratory Co., Ltd. 386-1, Ho-Dong, Yongin-City, Kyungki-Do, Korea 449-100 Tel: +82-31-339-9970 Fax: +82-31-339-9855 http://www.certitek.com/ CERTiTEK Radiated Electric Field Emissions Test Report No.: CTK03-F111 Date: November 5, 2003 Page 2 of 2 This Report shall not be reproduced except in full without the written approval of CERTiTEK Form No.: CTK-FF1.2

Contact Information

Applicant

Ho-joong Kim(Engineer)
[email protected]82-2-3016-6859Fax: 82-2-3016-6866

Test Firm

CTK Co., Ltd.Jang-Hee Hong
[email protected]031-339-9871Fax: 031-339-9855

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Corecess Inc.

SHDSL MODEM - FCC ID QB3CORECESS3311N - Corecess Inc.
QB3CORECESS3311N

SHDSL MODEM

Jan 23, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
VDSL Modem - FCC ID QB3CORECESS3221 - Corecess Inc.
QB3CORECESS3221

VDSL Modem

Sep 06, 2004

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
ADSL Modem - FCC ID QB3CORECESS3121 - Corecess Inc.
QB3CORECESS3121

ADSL Modem

Apr 12, 2004

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
ADSL Router - FCC ID QB3CORECESS3115 - Corecess Inc.
QB3CORECESS3115

ADSL Router

Apr 06, 2004

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
ADSL Modem - FCC ID QB3CORECESS3114 - Corecess Inc.
QB3CORECESS3114

ADSL Modem

Sep 18, 2002

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral