FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Technalogix, Ltd./
  3. QH5TM100

QH5TM100Modulator

Technalogix, Ltd.
Modulator - FCC ID QH5TM100 - Technalogix, Ltd.
Click to zoom

Application Details

Equipment Class
TBC - Licensed Broadcast Station Transmitter
Date of Grant
Apr 14, 2005
Application Purpose
Original Equipment
Date of Application
Mar 01, 2005
Equipment Note
Modulator
Frequency Range
54.00000000 - 806.00000000
Company
Technalogix, Ltd.
Country
Canada

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—
โ†—
โ†—

Operational Description

โ†—

Parts List/Tune Up Info

โ†—

Schematics

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Test Report

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TM-100 BROADCAST MODULATOR OPERATING MANUAL Technalogix Technalogix Ltd. TM-100 Modulator 1 TABLE OF CONTENTS 1.0 SAFEGUARDS.....................................................................................................................2 General Safeguards................................................................................................................2 Safety and First Aid.................................................................................................................3 2.0 WARRANTY........................................................................................................................4 3.0 DESCRIPTION AND SPECIFICATIONS....................................................................................5 General Description................................................................................................................5 Available Options....................................................................................................................6 Specifications..........................................................................................................................6 Video Conditioning Module.....................................................................................................9 4.0 INSTALLATION....................................................................................................................9 Building Recommendations....................................................................................................9 Heating and Cooling Requirements........................................................................................9 Electrical Service Recommendations...................................................................................10 Antenna and Tower Recommendations...............................................................................10 Shelter Security.....................................................................................................................11 Unpacking and Inspection....................................................................................................12 Location and Function of Controls and Connectors.............................................................13 5.0 OPERATING PROCEDURE..................................................................................................15 Preliminary Hook-up.............................................................................................................15 Setup and Operation.............................................................................................................15 Transmitter Hookup..............................................................................................................18 6.0 BILL OF MATERIALS, SCHEMATICS, AND PCB OVERLAYS................................................20 Agile Logic Board..................................................................................................................20 Agile Output Amplifier Board................................................................................................25 Audio Video Modulator Board...............................................................................................28 Digital Up converter Board....................................................................................................37 750 MHz Down Converter Board..........................................................................................43 Power Supply Board.............................................................................................................49 Technalogix Ltd. TM-100 Modulator 2 1.0 SAFEGUARDS General Safeguards This section is written as a general guide for those having previous knowledge and experience with these kinds of equipment. It is not intended to contain a complete statement of all safety precautions, which should be observed by personnel using this or other electronic equipment. To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. Do not open the cabinet. Refer servicing to qualified personnel. 1. READ INSTRUCTIONS - All safety, installation, and operating instructions should be read before the equipment is operated. 2. RETAIN INSTRUCTIONS - The safety and operating instructions should be retained for future reference. 3. FOLLOW INSTRUCTIONS - All safety, installation, and operating instructions should be followed. 4. GROUNDING AND POLARIZATION - The TM-100 Modulator is equipped with a three prong grounded power plug. Do not remove the ground prong from the plug. Do not use an AC receptacle where the plug blades cannot be fully inserted. 5. SERVICING - Do not attempt to service this equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards and will void the warranty. Refer all servicing to qualified service personnel. 6. DAMAGE REQUIRING SERVICE - Unplug this equipment and refer servicing to qualified service personnel under the following conditions: โ€ข if the power cord or plug is damaged. โ€ข if liquid has been spilled or objects have fallen into the equipment. โ€ข if the equipment has been exposed to rain or water. โ€ข if the equipment does not operate normally by following the operating instructions. Adjust only those controls covered by the operating instructions. An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the equipment to its normal operation. โ€ข if the equipment has been dropped or the cabinet has been damaged. โ€ข if the equipment exhibits a distinct change in performance. Technalogix Ltd. TM-100 Modulator 3 Safety and First Aid Personnel engaged in the installation, operation, maintenance, or servicing of electronic equipment are exposed to the hazard of high voltage. It is imperative that all safety regulations and precautions are consistently observed.โ€ฆ

Text truncated - open the document above for the full version.

Block Diagram

Local Oscillator Output 952 MHz to 1.703 GHz Ch T7 to Ch 118 750 MHz Low Pass Filter 945 MHz Toko Filter Up Converter Output V 945.75 MHz A 941.25 MHz 945 MHz Toko Filter 900 MHz Oscillator Combined IF Input V 45.75 Mhz + A 41.25 Mhz Audio IF Output 41.25 MHz @ 29dBmV PLL 41.25 MHz Audio Deviation pot on Logic Board 45.75 MHz Oscillator Biasing Amp to control IF Power Video IF Output 45.75 MHz @ 44dBmV 44MHz Saw Amp Amp AmpAmp Amp Amp AmpAmp Amp Amp Amp Amp Mixer Filter Adjustable Bankdpass Filter Harmonic Filter Harmonic Filter Pin Diode Power Control Pin Diode Power Control Mixer Mixer Out UC input Out Input Out Audio IN Out Video In TM100 Block Diagram Title: Date: March 3, 2005Page: 1 of 2 RevID

Cover Letter(s)

February 8, 2005 This report is in support of an application by Technalogix Ltd. for certification of transmitting equipment used for VHF and UHF television systems (54-806 MHz). Specifically, Technalogix is requesting certification of the Technalogix TM-100 frequency agile television modulator. The TM-100 accept standard video and audio and supplies a +15 dBm peak video signal in addition to 10% aural power on any of the VHF (2 through 13) and UHF (14 through 69) channels. Tests were conducted on production models of the equipment on location at Technalogix: #4, 8021 Edgar Industrial Place Red Deer, Alberta Canada T4P 3R3 403.347.5400 ph 403.347.7444 fx All tests were carried out on representative channels in the VHF and UHF bands in accordance with FCC Part 73 and Part 74. The results in the attached documentation show that the equipment meets or exceeds the required specifications. Included with the documentation is: โ€ข Drawing of the FCC label that will be attached to the equipment โ€ข Test report โ€ข RF exposure statements โ€ข Construction photos โ€ข Technalogix user manual. The user manual includes block diagrams of the various systems and sub-systems, schematics and printed circuit board component outlines, and specifications. The emission designators based on FCC Part 74 transmitters are 5M75C3F (for visual) and 250KF3E (for aural). Should you have any questions, please do not hesitate to contact Technalogix: Bob Gullon, President and CEO [email protected] Aaron Sivacoe, Engineering Manager [email protected] Technalogix Ltd. #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 Fax: (403) 347-7444 www.technalogix.ca [email protected]

Cover Letter(s)

Please note that the following sections are included in the instruction manual and are not separate sections: a. Tune-up Procedure b. Block Diagrams c. Schematics d. Specifications Technalogix Ltd. #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 Fax: (403) 347-7444 www.technalogix.ca [email protected]

Cover Letter(s)

February 8, 2005 This report is in support of an application by Technalogix Ltd. for certification of transmitting equipment used for VHF and UHF television systems (54-806 MHz). Specifically, Technalogix is requesting certification of the Technalogix TM-100 frequency agile television modulator. The TM-100 accept standard video and audio and supplies a +15 dBm peak video signal in addition to 10% aural power on any of the VHF (2 through 13) and UHF (14 through 69) channels. Tests were conducted on production models of the equipment on location at Technalogix: #4, 8021 Edgar Industrial Place Red Deer, Alberta Canada T4P 3R3 403.347.5400 ph 403.347.7444 fx All tests were carried out on representative channels in the VHF and UHF bands in accordance with FCC Part 73 and Part 74. The results in the attached documentation show that the equipment meets or exceeds the required specifications. Included with the documentation is: โ€ข Drawing of the FCC label that will be attached to the equipment โ€ข Test report โ€ข RF exposure statements โ€ข Construction photos โ€ข Technalogix user manual. The user manual includes block diagrams of the various systems and sub-systems, schematics and printed circuit board component outlines, and specifications. The emission designators based on FCC Part 74 transmitters are 5M75C3F (for visual) and 250KF3E (for aural). Should you have any questions, please do not hesitate to contact Technalogix: Bob Gullon, President and CEO [email protected] Aaron Sivacoe, Engineering Manager [email protected] Technalogix Ltd. #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 Fax: (403) 347-7444 www.technalogix.ca [email protected]

Cover Letter(s)

[email protected] April 12, 2005 ATT: FCC ID: QH5TM100 Correspondence: 28757 The data submitted for FCC certification was for VHF channels. We also tested the TM- 100 at UHF channels and found identical results as long as the video/audio carrier ratio was set at the same level. Thank you Bay 4, 8021 Edgar Industrial Place Red Deer, AB T4P 3R3 PH: 1-403-347-5400 FAX: 1-403-347-7444

External Photos

Construction Photographs

ID Label/Location Info

Label location will be centered in the middle of the top cover of the enclosure. Technalogix Ltd. #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 Fax: (403) 347-7444 www.technalogix.ca [email protected] TECHNALOGIX LTD. Made in Red Deer, AB Canada FCC ID:QH5TM100 I.C. :tbd Model No:TM-100 Serial No: Actual Size: 2" x 3 1/4"

Internal Photos

Construction Photographs

Internal Photos

Technalogix โ€“ the company that can! CONSTRUCTION POTOGRAPHS Front and Back Panel View: Internal View: #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 [email protected] Fax: (403) 347-7444 www.technalogix.ca Technalogix โ€“ the company that can! Internal View with Shields of Upconverter and Downconverter Removed: Solder Side of Main Audio Video Modulator PCB: Technalogix โ€“ the company that can! Internal view of Upconverter and Downconverter PCB:

Internal Photos

Technalogix โ€“ the company that can! CONSTRUCTION POTOGRAPHS Front and Back Panel View: Internal View: #4 โ€“ 8021 Edgar Ind. Place, Red Deer, AB T4P 3R3 Ph: (403) 347-5400 [email protected] Fax: (403) 347-7444 www.technalogix.ca Technalogix โ€“ the company that can! Internal View with Shields of Upconverter and Downconverter Removed: Solder Side of Main Audio Video Modulator PCB: Technalogix โ€“ the company that can! Internal view of Upconverter and Downconverter PCB:

Operational Description

TM-100 BROADCAST MODULATOR OPERATING MANUAL Technalogix Technalogix Ltd. TM-100 Modulator 1 TABLE OF CONTENTS 1.0 SAFEGUARDS.....................................................................................................................2 General Safeguards................................................................................................................2 Safety and First Aid.................................................................................................................3 2.0 WARRANTY........................................................................................................................4 3.0 DESCRIPTION AND SPECIFICATIONS....................................................................................5 General Description................................................................................................................5 Available Options....................................................................................................................6 Specifications..........................................................................................................................6 Video Conditioning Module.....................................................................................................9 4.0 INSTALLATION....................................................................................................................9 Building Recommendations....................................................................................................9 Heating and Cooling Requirements........................................................................................9 Electrical Service Recommendations...................................................................................10 Antenna and Tower Recommendations...............................................................................10 Shelter Security.....................................................................................................................11 Unpacking and Inspection....................................................................................................12 Location and Function of Controls and Connectors.............................................................13 5.0 OPERATING PROCEDURE..................................................................................................15 Preliminary Hook-up.............................................................................................................15 Setup and Operation.............................................................................................................15 Transmitter Hookup..............................................................................................................18 6.0 BILL OF MATERIALS, SCHEMATICS, AND PCB OVERLAYS................................................20 Agile Logic Board..................................................................................................................20 Agile Output Amplifier Board................................................................................................25 Audio Video Modulator Board...............................................................................................28 Digital Up converter Board....................................................................................................37 750 MHz Down Converter Board..........................................................................................43 Power Supply Board.............................................................................................................49 Technalogix Ltd. TM-100 Modulator 2 1.0 SAFEGUARDS General Safeguards This section is written as a general guide for those having previous knowledge and experience with these kinds of equipment. It is not intended to contain a complete statement of all safety precautions, which should be observed by personnel using this or other electronic equipment. To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. Do not open the cabinet. Refer servicing to qualified personnel. 1. READ INSTRUCTIONS - All safety, installation, and operating instructions should be read before the equipment is operated. 2. RETAIN INSTRUCTIONS - The safety and operating instructions should be retained for future reference. 3. FOLLOW INSTRUCTIONS - All safety, installation, and operating instructions should be followed. 4. GROUNDING AND POLARIZATION - The TM-100 Modulator is equipped with a three prong grounded power plug. Do not remove the ground prong from the plug. Do not use an AC receptacle where the plug blades cannot be fully inserted. 5. SERVICING - Do not attempt to service this equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards and will void the warranty. Refer all servicing to qualified service personnel. 6. DAMAGE REQUIRING SERVICE - Unplug this equipment and refer servicing to qualified service personnel under the following conditions: โ€ข if the power cord or plug is damaged. โ€ข if liquid has been spilled or objects have fallen into the equipment. โ€ข if the equipment has been exposed to rain or water. โ€ข if the equipment does not operate normally by following the operating instructions. Adjust only those controls covered by the operating instructions. An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the equipment to its normal operation. โ€ข if the equipment has been dropped or the cabinet has been damaged. โ€ข if the equipment exhibits a distinct change in performance. Technalogix Ltd. TM-100 Modulator 3 Safety and First Aid Personnel engaged in the installation, operation, maintenance, or servicing of electronic equipment are exposed to the hazard of high voltage. It is imperative that all safety regulations and precautions are consistently observed.โ€ฆ

Text truncated - open the document above for the full version.

Parts List/Tune Up Info

TM-100 BROADCAST MODULATOR OPERATING MANUAL Technalogix Technalogix Ltd. TM-100 Modulator 1 TABLE OF CONTENTS 1.0 SAFEGUARDS.....................................................................................................................2 General Safeguards................................................................................................................2 Safety and First Aid.................................................................................................................3 2.0 WARRANTY........................................................................................................................4 3.0 DESCRIPTION AND SPECIFICATIONS....................................................................................5 General Description................................................................................................................5 Available Options....................................................................................................................6 Specifications..........................................................................................................................6 Video Conditioning Module.....................................................................................................9 4.0 INSTALLATION....................................................................................................................9 Building Recommendations....................................................................................................9 Heating and Cooling Requirements........................................................................................9 Electrical Service Recommendations...................................................................................10 Antenna and Tower Recommendations...............................................................................10 Shelter Security.....................................................................................................................11 Unpacking and Inspection....................................................................................................12 Location and Function of Controls and Connectors.............................................................13 5.0 OPERATING PROCEDURE..................................................................................................15 Preliminary Hook-up.............................................................................................................15 Setup and Operation.............................................................................................................15 Transmitter Hookup..............................................................................................................18 6.0 BILL OF MATERIALS, SCHEMATICS, AND PCB OVERLAYS................................................20 Agile Logic Board..................................................................................................................20 Agile Output Amplifier Board................................................................................................25 Audio Video Modulator Board...............................................................................................28 Digital Up converter Board....................................................................................................37 750 MHz Down Converter Board..........................................................................................43 Power Supply Board.............................................................................................................49 Technalogix Ltd. TM-100 Modulator 2 1.0 SAFEGUARDS General Safeguards This section is written as a general guide for those having previous knowledge and experience with these kinds of equipment. It is not intended to contain a complete statement of all safety precautions, which should be observed by personnel using this or other electronic equipment. To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. Do not open the cabinet. Refer servicing to qualified personnel. 1. READ INSTRUCTIONS - All safety, installation, and operating instructions should be read before the equipment is operated. 2. RETAIN INSTRUCTIONS - The safety and operating instructions should be retained for future reference. 3. FOLLOW INSTRUCTIONS - All safety, installation, and operating instructions should be followed. 4. GROUNDING AND POLARIZATION - The TM-100 Modulator is equipped with a three prong grounded power plug. Do not remove the ground prong from the plug. Do not use an AC receptacle where the plug blades cannot be fully inserted. 5. SERVICING - Do not attempt to service this equipment yourself as opening or removing covers may expose you to dangerous voltage or other hazards and will void the warranty. Refer all servicing to qualified service personnel. 6. DAMAGE REQUIRING SERVICE - Unplug this equipment and refer servicing to qualified service personnel under the following conditions: โ€ข if the power cord or plug is damaged. โ€ข if liquid has been spilled or objects have fallen into the equipment. โ€ข if the equipment has been exposed to rain or water. โ€ข if the equipment does not operate normally by following the operating instructions. Adjust only those controls covered by the operating instructions. An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the equipment to its normal operation. โ€ข if the equipment has been dropped or the cabinet has been damaged. โ€ข if the equipment exhibits a distinct change in performance. Technalogix Ltd. TM-100 Modulator 3 Safety and First Aid Personnel engaged in the installation, operation, maintenance, or servicing of electronic equipment are exposed to the hazard of high voltage. It is imperative that all safety regulations and precautions are consistently observed.โ€ฆ

Text truncated - open the document above for the full version.

Schematics

1 1 3 3 EEPROM MEMORY STORAGE MUTE SPARES/DEMOD (360 MOD)VIDEO MODULATION VIDEO OUT MODULATOR INPUT VIDEO IN 370/370T VIDEO GAIN (360.361.362 360 VIDEO MOD ADJ 361/2 ALR LEVEL 360 VIDEO MODULATION NOTES: ON M/N UNITS W411808 DISPLAY BD. ONLY 1. CUT THE ETCH CONNECTING PINS 6&9 ON TOP OF P5 ON TOP OF BOARD 2. CUT THE ETCH CONNECTING PINS 7&11 ON P5 ON BOTTOM OF BOARD 3. CONNECT PINS 1&6 OF P5 W/INSULATED WIRE ON BOTTOM OF BOARD 4. CONNECT PINS 2&7 OF P5 W/INSULATED WIRE ON BOTTOM OF BOARD -20dB RF MONITOR 90-F MONITOR IN 360 BAR GRAPH DISPLAY (370 MOD) T CHANNEL (370 MOD) VHF/UHF TO JP2 P5-4 TO P6.2 DEDOM INTERFACE +12V N/C 360 TEXT OVERLAY OPTION5K/370 500R/360 100K/361-2 (360/370) (361/2) TDO RDI RSTX RSRX LDO LDI LD +12V TEST NORM INPUT CH OUTPUT CH INPUT MODE INPUT LD +30V +12V (362.SW3 3 W/R17) +5V +5V (DEMOD) W/R23 CW/R23 RSTX RSRX 25 KHz 12.5KHz +12V TO RP RJ11 +5V MUTE -12V REF DATA LDO 12.5KHz OUT PLL EN CLOCK 25KHz +12V +5V -12V +24V +12V IN PLL EN DATA CLOCK LD OFF OUT LVL OUT LVL PROCESSOR INPUT TO UP CONV. TO OUTPUT CONV. W/R17 C20 PLLI EN PLLO EN PLL EN DATA IO CLK PWR SBSEL LED1 LED0 SPR41 SPR51 SPR61 VIN VRST DATA IO CLK +5V N/C OUT LVL OMIT FOR DEMOD FP OUTPUT LEVEL ADJ TO JP5.2 TO JP5.3 TO P4.2 RSRX TO P4.1 RSTX C5045.6 REAR PANEL RJ11/RS232 INPUT +25V P/S LED +30V +12V -12V FROM P/S VIDEO TEXT OVERLAY P1 P2 P3 P4P5 P6 P7 P8 JP3 P1 P2 P3 P4P5 P6 P7 P8 U8 1 2 3 4 5 6 7 89 10 11 12 13 14 15 16 U11 QP1 12 10 5 3 13 14 9 8 6 7 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 P5 1 2 3 4 5 6 7 89 10 11 12 13 14 15 16 JP2 RP5 RP4 1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 U9 1 2 3 4 5 6 7 89 10 11 12 13 14 15 16 U7 NOT RESET NOT IRQ NOT VPR SW1UP SW1DWN SW0UP SW0DWN PA3 PA2 S/L SHREG DATAIO CLK DSPEN VRST PLLIEN PLLOEN PLLEN PWR GNDISTHR OFF AIR SPR6I SPR5I SPR4I LED0 LED1 SBSEL RDI TDO LD0 LDI LD PD 5 MUTE1 VIN TCAP OSC 2 OSC 1 Vdd U6 S1 S2 S3 5V 1 9 8 6 7 3 2 5 4 RP3 + C8 IN COM OUT U3 + C7 5V Y1 C4C3 1 2 3 4 5 6 9 10 RP2 RP1 5V 5V C2 L1 + C9 +5V Q1 Q2 +12V JP4 + C12 + C13 + C14 + C1 + C11 + C10 + C6 + C5 5V D4 LOCK LED P7 P4 P3 P6 U2F U2E U2D U2C U2B U2A U1F U1E U1D U1C U1B U1A P10 R3 +5V D3 D2 R171 P1 J1 L3 +5V + C181 +12V JPR P111 P9 R111 R14 10k 40% + C200 J2 CON + C191 + C161 +5V SW4 12V JP6 P100 P200 J101 P12 POWER ON LED C22C21 L4 +5V L5 C23C24 +12V U4 U5 +5V+5V P1 P2 P3 P4P5 P6 P7 P8 JP1 R11 R2 R18 R19 R20 R16 R9 R8 R7R6 R4 R121 R13 R10 R5 R21 R1 R15 R221 32 11 9 1 1 4 3 2 1 3 21 98 4 11 5 13 10 3 9 1 1 12 11 5 4 3 7 6 5 4 3 2 1 10 9 8 7 6 5 4 2 1 1 7 6 5 11 32 31 4 3 2 4 1 3 1 3 2 3 3 1 35 12 13 14 1 1 13 10 1 1 2 37 36 34 22 21 6 7 4 5 21 22 9 8 12 19 1 37 19 18 17 16 15 14 13 12 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 11 10 9 8 7 6 5 4 2 1 1 111 1 1 1 1 Technalogix Ltd. #4, 8021 Edgar Industrial Place Red Deer, Alberta, Canada T4P 3R3 Agile Logic C Date: 09/11/00Page: 1 of 1 RevID 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 AA BB CC DD EE FF GG

Schematics

4 3 2 1 4 3 2 1 4 3 2 1 GND +24V GND +12V +5V +30V 1 2 3 4 5 6 P2 1 2 3 4 5 6 P3 1 2 3 4 5 6 P4 1 2 3 4 5 6 P5 1 2 3 4 5 6 P6 C13C11 + C17C3 1 IN 2 COM 3 OUT +30V U3 LM317 C6 + C14 C19 C18 + C2C8 1 IN 2 COM 3 OUT +12V U5 7812 C10 + C9 C12 1 2 3 4 5 6 7 8 P7 + C16C15 1 IN 2 COM 3 OUT +5V U6 7805 6 5 4 3 2 1 P1 + C7C5 1 IN 2 COM 3 OUT +24V U4 7824 + C1C4 U7 U2 U1 R2 R4 R1 Technalogix Ltd. #4, 8021 Edgar Industrial Place Red Deer, Alberta, Canada T4P 3R3 Power Supply Board D Date: 09/11/00Page: 1 of 1 RevID 1 1 2 2 3 3 4 4 5 5 6 6 7 7 AA BB CC DD EE FF GG HH II JJ

Schematics

AUDIO/INPUT FROM LOGIC BOARD P8 TO LOGIC BOARD P11 VIDEO OUT P103 P2:4 P2:3P2:1 L2 L200 P1 P2 P3 P4P5 P6 P7 P8 U11 3 8 1 65 7 2 4 U100 P101 P1 P2P3 P4 GROUP DELAY F100 P1P2P3P4 P5P6P7P8 U102 P1P2P3P4P5P6P7P8 P9 P10P11P12P13P14P15P16 U101 P1 P2 P3 P4 P5 P6 P7 P8 P9P10 P11 P12 P13 P14 P15 P16 P17 P18 U10 L15 +12V C47 D1 C4 C2 5 6 4 7 + U1:B + C3 P2:5 TB1 P2:6 C6 + C5 +12V + C8 3 2 8 1 + U1:A C9 C7 J1 STEREO + C46 +12V C13 C21 C25 C22 C23 C24 Y1 JP5 JP4 JP2 JP1 JP3 C27 C26 +12V D8 C28 D7 +12VA C11 D2 D3 C10 3 28 4 1 + U103:A +12V P2:9 C12 R15 C14 D6 L1 C15 +12V C16 + C38 Q3 C17 C18 C115 D101 D100 C116 5 6 8 4 7 + U103:B +12V P2:10 C117 R125 TP100 Q102 +12V C113 + C112 Q103 Q101 Q104 C114 R120 +12V +12V + C45 Q106 C118 +12V C129 + C106 C107 C109 + C108 C111 +12V C110 +12V Q100 P100P102 + C100 + C102 C130 C101 C105 C104 C103 +12V C29 C30 C32 C31 P8:1 P8:2 P2:7 +12V C41 C40 C39 D11 D9 D10 C43 P2:8 L5 C42 P1 +12V + C44 + C156 P2:2 P7:5 TP1 C33 C20 Q2 C19 L3L4 TP2 C35 C34 C36C37 C123 L100 C124 C128 C125 C126 y100 Q107 C127 C122 12V C120 Q5 + C121 R130 MX2 1 2 3 45 6 7 8 TP1 C119 C131 C132 Q6 C133 L101 C136 C134 C135 12V F101 5 1 C142 C139 12V C137 C140C141 C138 Q7 L102 C143 C145 L103L104 C146 C144 C147 C148 Q4 C149 L105 C150 C154 C155 12V C151C152 C153 L106L107 R5 R4 R2 R1R23 R10 R8R9 R3 R12 R7 R11 R24R26 R25 R13 R18 R27 R29 R28 R14 R17 R16 R19 R20 R21 R22 R123 R126 R124 R118 R115R114 R116 R119 R117 R121 R122 R134 R133 R127 R107 R106 R105 R113 R112 R104 R111 R110 R109 R108 R100 R101R102 R103 R37R36R35 R32 R33 R34 R31 R38R39 R40 R30 R42 R135 R136 R137 R140 R138 R139 R132 R131 R129 R128 R141 R142 R143 R147 R144 R145 R146 R148 R150 R151 R152 R149 R159 R156R155 R158 R153R154 R157 R160 R161 R162 R163 R164 R166 R165 R170 R167 R168 R169 Technalogix Ltd. #4, 8021 Edgar Industrial Place Red Deer, Alberta, Canada T4P 3R3 Audio Video Modulator Board E Date: 09/11/00Page: 1 of 1 RevID 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 AA BB CC DD EE FF GG

Schematics

L3 C4C5 L5L2 C6 L4 C3 P1 OUTPUT E3 -20dB TEST 19 5 2 + U1 C7 E2 +24V E1 INPUT L1 C2C1 R1 Technalogix Ltd. #4, 8021 Edgar Industrial Place Red Deer, Alberta, Canada T4P 3R3 Agile Output Amplifier Board H Date: 09/11/00Page: 1 of 1 RevID 1 1 2 2 3 3 4 4 5 5 6 6 7 7 AA BB CC DD EE FF GG HH II JJ

Schematics

P3 LOCK DETECT TO MPU LO RF RF OUT L204 C214 C211 12V C215 C213C212 C210 C209 L203L202 C208 C207 C206 L201 L200 C205 C42 12V C47C48 C43 C20โ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Robert Gullon(President)
[email protected]403-347-5400Fax: 403-347-7444

Technical Contact

Technalogix LtdAaron M Sivacoe
[email protected]403-347-5400

Bay 4, ยท Red Deer, Alberta ยท Canada

Non-Technical Contact

Technalogix LtddAaron M Sivacoe
[email protected]403-347-5400

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
27454 MHz - 806 MHz1.40 mW250KF3E1000 Hz

Other Applications from Technalogix, Ltd.

FM Broadcast Transmitter, 500-Watts - FCC ID QH5TXF500 - Technalogix, Ltd.
QH5TXF500

FM Broadcast Transmitter, 500-Watts

Dec 16, 2014

Equipment Class

TBC - Licensed Broadcast Station Transmitter
FM Broadcast Transmitter, 50 Watts - FCC ID QH5TXF50 - Technalogix, Ltd.
QH5TXF50

FM Broadcast Transmitter, 50 Watts

Oct 02, 2014

Equipment Class

TBC - Licensed Broadcast Station Transmitter
FM Broadcast Transmitter, 1000-Watts - FCC ID QH5TXF1000 - Technalogix, Ltd.
QH5TXF1000

FM Broadcast Transmitter, 1000-Watts

Jun 11, 2014

Equipment Class

TBC - Licensed Broadcast Station Transmitter
FM Broadcast Transmitter, 300 Watts - FCC ID QH5TXF300 - Technalogix, Ltd.
QH5TXF300

FM Broadcast Transmitter, 300 Watts

May 08, 2014

Equipment Class

TBC - Licensed Broadcast Station Transmitter
1000 W Digital TV Transmitter - FCC ID QH5TXUD1000 - Technalogix, Ltd.
QH5TXUD1000

1000 W Digital TV Transmitter

May 24, 2011

Equipment Class

TBC - Licensed Broadcast Station Transmitter