Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Oct 05, 2003
Application Purpose
Original Equipment
Date of Application
Oct 05, 2003
Equipment Note
Energy Saving Lamp
Frequency Range
0.04000000 - 0.05000000
Company
Everbright Lighting Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page 1 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 EXHIBIT 7 User Manual Page 2 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 USER MANUAL OF ENERGY SAVING LAMP Self-ballasted fluorescent (electronic energy saving lamp) is a new kind of lighting style that uses trip-phospher tube with electronic ballast. It is characterized of energy saving, long life and flicker-free, and is widely used for restaurants, hotels, shops, homes lighting. 1. Specifications: EBU - 5W, 7W, 11W, 13W, 15W AC 120V 60Hz 2. Working environment temperature: -18~ 40. 3. Precautions: z Use only on 120 volt, 60 hertz; z Never disassemble of modify the lamp---any changes could void the user’s authority to operate this device; z Not for use in totally enclosed fixture; z Risk of electric shock---do not use where directly exposed to water; z This device is not intended for use with emergency exit fixtures or emergency exit lights; z To prevent burns, do not touch the bulb or cap during operation or immediately after switching off; z Handle the plastic enclosure when replacement; z Not for use with dimmers, electronic timer or photocell devices or occupancy sensor. z This product could produce interference when used near a TV, radio, wireless remote control or maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. If interference should occur, move the lamp away from the appliance a distance of three feet or more. Or plug the lamp or the compliance into a different outlet. Page 3 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 z To prevent risk of fire, never install this device in the following fixtures: a. Fixture on dimming circuits. b. Emergency exit lights powered by direct current (DC). 4. COMPLIANCE INFORMATION STATEMENT Product Name: Energy Saving Lamp Model number: EBU - 5W, 7W, 11W, 13W, 15W This device complies with part 18 of FCC Rules. ****** FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance will void the user’s authority to operate this equipment.

Block Diagram

Page 3 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Block Diagram AC120V/60Hz AC INPUT COMMUTATE LAMP TUBE TOUCH OFF CHOKE HIGH FREQUENCY TRANSFER > 40 KHz FILTER

External Photos

Page 5 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Bill of Difference The models EBU-5W, 7W, 11W, 13W, 15W are the same, except the following components list different: Components/ rating Models C1 C5 C6 C7 C2 Fuse Q1, 2 5W 0.1uF 400V 47nF, 400V 2.2nF, 1000V 2.2nF, 1000V 6.8uF 250V 250V, 0.5A 13001/ DK52 7W 0.1uF 400V 47nF, 400V 3.3 nF, 1000V 2.2nF, 1000V 6.8uF 250V 250V, 0.5A 13001/ DK2 11W 0.1uF 400V 47nF, 400V 3.3 nF, 1000V 2.2nF, 1000V 10uF 250V 250V, 1A 13002/ DK-52 13W 0.1uF 400V 47nF, 400V 4.7nF, 1000V 2.2nF, 1000V 15uF 250V 250V, 1A 13003 15W 0.1uF 400V 47nF, 400V 4.7nF, 1000V 2.2nF, 1000V 15uF 250V 250V, 1A 13003 Page 6 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Circuit Diagram

ID Label/Location Info

Page 1 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 EXHIBIT 1 Label Drawing Page 2 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 For M/N: EBU-5/7/11/13/15W Label FCC ID: QJKEBETUS0310 This device complies with part 18 of the FCC Rules. Not for use with dimmers EBU-5W 120Vac/60Hz Made in Everbright Lighting Ltd FCC ID: QJKEBETUS0310 This device complies with part 18 of the FCC Rules. Not for use with dimmers EBU-7W 120Vac/60Hz Made in Everbright Lighting Ltd FCC ID: QJKEBETUS0310 This device complies with part 18 of the FCC Rules. Not for use with dimmers EBU-11W 120Vac/60Hz Made in Everbright Lighting Ltd FCC ID: QJKEBETUS0310 This device complies with part 18 of the FCC Rules. Not for use with dimmers EBU-13W 120Vac/60Hz Made in Everbright Lighting Ltd FCC ID: QJKEBETUS0310 This device complies with part 18 of the FCC Rules. Not for use with dimmers EBU-15W 120Vac/60Hz Made in Everbright Lighting Ltd

ID Label/Location Info

Page 1 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 EXHIBIT 2 ID Label Page 2 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Figure 1 M/N: EBU-5W ID Label Figure 2 M/N: EBU-7W ID Label Label Location Label Location Page 3 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Figure 3 M/N: EBU-11W ID Label Figure 4 M/N: EBU-13W ID Label Label Location Label Location Page 4 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Figure 5 M/N: EBU-15W ID Label Label Location

Internal Photos

Page 4 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Figure 3 M/N: EBU-5/7/11/13/15W Main Board, Component Side Figure 4 M/N: EBU-5/7/11/13/15W Main Board, Cu Foil Side

Schematics

Page 5 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Bill of Difference The models EBU-5W, 7W, 11W, 13W, 15W are the same, except the following components list different: Components/ rating Models C1 C5 C6 C7 C2 Fuse Q1, 2 5W 0.1uF 400V 47nF, 400V 2.2nF, 1000V 2.2nF, 1000V 6.8uF 250V 250V, 0.5A 13001/ DK52 7W 0.1uF 400V 47nF, 400V 3.3 nF, 1000V 2.2nF, 1000V 6.8uF 250V 250V, 0.5A 13001/ DK2 11W 0.1uF 400V 47nF, 400V 3.3 nF, 1000V 2.2nF, 1000V 10uF 250V 250V, 1A 13002/ DK-52 13W 0.1uF 400V 47nF, 400V 4.7nF, 1000V 2.2nF, 1000V 15uF 250V 250V, 1A 13003 15W 0.1uF 400V 47nF, 400V 4.7nF, 1000V 2.2nF, 1000V 15uF 250V 250V, 1A 13003 Page 6 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Circuit Diagram

Test Report

Page 1 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 EXHIBIT 5 Test Report Page 2 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 APPLICATION FOR CERTIFICATION On Behalf of Everbright Lighting Ltd. Energy Saving Lamp Model Number : EBU-5W, 7W, 11W, 13W, 15W Prepared for : Everbright Lighting Ltd. 13/F., Universal Industrial Center, 19-21Shan Mei Street, Fo Tan, Shatin, N.T., Hong Kong Prepared by : Shenzhen EMTEK Co., Ltd. Bldg 69, Majialong, Taipinyang Industrial Zone, Nanshan District, Shenzhen, Guangdong, China Telephone : (0755) 26954280 Report No. : AT03282-3 Date of Test : July 30 – August 5, 2003 Date of Report : August 6, 2002 Page 3 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 TABLE OF CONTENTS Description Page Test Report Declaration EXHIBIT 5..........................................................................................................................................1 1. GENERAL INFORMATION........................................................................................................5 1.1 Description of Device (EUT).................................................................................................................5 1.2 Test Facility..............................................................................................................................................6 1.3 Test Uncertainty......................................................................................................................................6 2. POWER LINE CONDUCTED EMISSION TEST.....................................................................7 2.1 Test Equipment.....................................................................................................................................7 2.2 Block Diagram of Test Setup.............................................................................................................7 2.3 Power Line Conducted Emission Test Limits...............................................................................7 2.4 Configuration of EUT on Test............................................................................................................7 2.5 Operating Condition of EUT..............................................................................................................8 2.6 Test Procedure......................................................................................................................................8 2.7 Power Line Conducted Emission Test Results............................................................................8 3. MODIFICATION TO TEST SPECIFICATIONS.....................................................................12 Appendix I: Power Line Conduction Emission Test Data Page 4 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 Page 5 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 1. GENERAL INFORMATION 1.1 Description of Device (EUT) Description :Energy Saving Lamp Model Number : EBU-5W, 7W, 11W, 13W, 15W Applicant :Everbright Lighting Ltd. 13/F., Universal Industrial Center, 19-21Shan Mei Street, Fo Tan, Shatin, N.T., Hong Kong Manufacturer :City Bright Lighting (Shenzhen) Co., Ltd Fuchengao Village, Pinghu Town, Longgang Region, Shenzhen, Guangdong, China Date of Receipt :July 10, 2003 Date of Test :July 30 – August 5, 2003 Page 6 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 1.2 Test Facility Site Description EMC Laboratory : Accredited by FCC, December 09,2002 The Certificate Registration No. is 709623. : Accredited by Industry Canada, January 8,2003 The Certificate Registration No. is 46405-4480 : Accredited by TUV Rheinland Guangdong March 26, 2001 The Certificate Registration No. is G2130000 Name of Firm : Shenzhen EMTEK Co., Ltd. Site Location : Bldg 69, Taipinyang Industrial Zone, Majialong, Nanshan, Shenzhen, Guangdong, China 1.3 Test Uncertainty Conducted Emission Uncertainty=Β±2.66dB Page 7 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 2. POWER LINE CONDUCTED EMISSION TEST 2.1 Test Equipment The following test equipments are used during the power line conducted emission test: Item Equipment Manufacturer Model No Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCS30 1102.4500 May 30, 03 1 Year 2. Pulse Limiter Rohde & Schwarz ESH3-Z2 100007 May 30, 03 1 Year 3. L.I.S.N Kyoritsu Corp. KNW407 8-1492-9 May 30, 03 1 Year 4. 50Ω Coaxial Switch Anritsu Corp. MP59B 61002175589 May 30, 03 1 Year 2.2 Block Diagram of Test Setup Block diagram of connection between the EUT and simulators (EUT: Energy Saving Lamp) 2.3 Power Line Conducted Emission Test Limits Te s t L i m i t s Frequency MHz dBΞΌV 0.45 ~ 2.51 48 2.51-3.0 70 3.0-30 48 2.4 Configuration of EUT on Test The following equipment are installed on Power Line Conducted Emission Test to meet the commission requirement and operating regulations in a manner which tends to maximize its emission characteristics in a normal application. Te s t R e c e i v e r AC Mains L.I.S.N. EUT Page 8 Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 2.4.1 Energy Saving Lamp (EUT) Model No. : EBU-5W, 7W, 11W, 13W, 15W Serial No. : F20030806003 Manufacturer : City Bright Lighting (Shenzhen) Co., Ltd 2.5 Operating Condition of EUT 2.5.1 Setup the EUT and simulator as shown as Section 2.2. 2.5.2 Turn on the power of all equipment. 2.5.3 Let the EUT work in test mode (ON) and test it. 2.6 Test Procedure 2.6.1 The EUT is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohms coupling impedance for the EUT. Please refer the block diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum conducted emission levels. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to ANSI C63.4…

Text truncated - open the document above for the full version.

Test Setup Photos

Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 4. PHOTOGRAPH 4.1 Photo of Power Line Conducted Emission Test (EBU-5W) (Front View) (Left View) Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 4.2 Photo of Power Line Conducted Emission Test (EBU-7W) (Front View) (Left View) Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 4.3 Photo of Power Line Conducted Emission Test (EBU-11W) (Front View) (Left View) Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 4.4 Photo of Power Line Conducted Emission Test (EBU-13W) (Front View) (Left View) Everbright Lighting Ltd. Energy Saving Lamp FCC ID: QJKEBETUS0310 4.5 Photo of Power Line Conducted Emission Test (EBU-15W) (Front View) (Left View)

Contact Information

Applicant

Edgar Wong(Marketing Manager)
[email protected](852) 2698 5388Fax: (852) 2695 0075

Test Firm

EMTEK (Shenzhen) Co., Ltd.David Lee
[email protected]86-755-26504659Fax: 86-755-26954282

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.04 MHz - 0.05 MHz-

Other Applications from Everbright Lighting Limited

Energy Saving Lamp - FCC ID QJKEBETUS0308 - Everbright Lighting Limited
QJKEBETUS0308

Energy Saving Lamp

Oct 05, 2003

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID QJKEBETUS0309 - Everbright Lighting Limited
QJKEBETUS0309

Energy Saving Lamp

Oct 05, 2003

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID QJKEBETUS0207 - Everbright Lighting Limited
QJKEBETUS0207

Energy Saving Lamp

Oct 02, 2002

Equipment Class

8CC - Part 18 Consumer Device