
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF-2054 Emitter Block Diagram Code Select PT2262 Encoder RF Amp Oscillator 315MHz SAW Filter ANT
Test Setup FCCID : QJORF2054 External Photo -front External Photo - rear
FCC ID : QJORF2054 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 31.1 mm 18.6mm
Test Setup FCCID : QJORF2054 Internal Photo - 1 Internal Photo - 2 Test Setup FCCID : QJORF2054 Internal Photo โ 3 Internal Photo โ 4
โข The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. โข This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. โข For Terms And Conditions of the services, it can be provided upon request. โข The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Advanced Timer Technologies Ltd. Application For Certification (FCC ID: QJORF2054) Transmitter WO# 0212749 DL/Sandy September 20, 2002 INTERTEK TESTING SERVICES FCC ID: QJORF2054 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: QJORF2054 ii MEASUREMENT/TECHNICAL REPORT Advanced Timer Technologies Ltd. - MODEL: Advanced Timer Technologies Ltd. RF-2054 FCC ID: QJORF2054 September 20, 2002 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-18-01 Edition] provision. Report prepared by:Derek Leung Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG. Phone:852-2173-8504 Fax:852-2371-0521 INTERTEK TESTING SERVICES FCC ID: QJORF2054 iii Table of Contents 1.0 General Description............................................................................................................2 1.1 Product Description............................................................................................................2 1.2 Related Submittal(s) Grants.................................................................................................2 1.3 Test Methodology...............................................................................................................3 1.4 Test Facility........................................................................................................................3 2.0 System Test Configuration.................................................................................................5 2.1 Justification.........................................................................................................................5 2.2 EUT Exercising Software....................................................................................................5 2.3 Special Accessories............................................................................................................5 2.4 Equipment Modification......................................................................................................6 2.5 Measurement Uncertainty....................................................................................................6 2.6 Support Equipment List and Description..............................................................................6 3.0 Emission Results.................................................................................................................8 3.1 Field Strength Calculation....................................................................................................9 3.2 Radiated Emission Configuration Photograph.....................................................................11 3.3 Radiated Emission Data....................................................................................................12 4.0 Equipment Photographs....................................................................................................15 5.0 Product Labelling..............................................................................................................17 6.0 Technical Specifications....................................................................................................19 7.0 Instruction Manual............................................................................................................21 8.0 Miscellaneous Information...............................................................................................23 8.1 Measured Bandwidth........................................................................................................24 8.2 Discussion of Pulse Desensitization....................................................................................25 8.3 Calculation of Average Factor...........................................................................................26 8.4 Emissions Test Procedures................................................................................................27 INTERTEK TESTING SERVICES FCC ID: QJORF2054 iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated photos.doc Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoexternal photos.doc Internal PhotoInternal Photointernal photos.doc Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf Timing DiagramTiming Diagramtiming.pdf INTERTEK TESTING SERVICES FCC ID: QJORF2054 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: QJOโฆ
Text truncated - open the document above for the full version.
Test Setup FCCID : QJORF2054 Radiated -front Radiated - rear
2/F., Garment Centre, ยท Kowloon ยท Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

REMOTE SWITCH
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter