QKH-2YEKN007Powered Speaker system

Kanto Living Inc.
Powered Speaker system - FCC ID QKH-2YEKN007 - Kanto Living Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 25, 2015
Application Purpose
Original Equipment
Date of Application
Jan 25, 2015
Equipment Note
Powered Speaker system
Frequency Range
2402.00000000 - 2480.00000000
Company
Kanto Living Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Kanto Grandstand Grandstand GRANDSTAND Le pré sent appareil est conforme aux CNR d’ Industrie Canada applicables aux appareils radio L’ exploitation est autorisé e aux deux conditions suivantes : (1) l’ appareil ne doit pas produire de brouillage, et (2) l’ utilisateur de l’ appareil doit accepter tout brouillage radioé lectrique subi, mê me si le brouillage est susceptible d’ en le fonctionnement. exempts de licence. B Grandstand RCA 3.5mm Model:Grandstand POWER SUB OUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1.Standby button press to enter standby mode. 2.Spdif(coaxial) 3.Spdif(optical) 4.Aux input 5.Bluetooth 6.Reset:default volume, 7.Volume button press" ", then volume will decrease; press" ", then volume will increase; 8.Bass button press"-", then bass will decrease; press"+", then bass will increase; 9.Treble button press"-", then treble will decrease; press"+", then treble will increase; 10.Bass reset 11.Mute 12.Treble reset 13.Balance L 14.Balance reset 15.Balance R 16.Next track 17.Prev track 18.Play/pause Standby power consumption: < 0.5W Kanto GS 8 OPTIONAL EXTERNAL SUBWOOFER: If you would like to hook-up an external Powered Subwoofer, connect it to Sub Out jack on the rear of the Speaker, using and RCA cable. This will not affect the function of the built-in powered subwoofer in the Speaker-Base. 3 audio

Cover Letter(s)

DATE : Jan 09, 2015 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: QKH-2YEKN007 Product Name: Powered Speaker system Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this Jan 09, 2015 Agency agreement expiration date: Usually Give 8 - 12 Months By: Robert E. Maudsley Signature Printed Title: VP Marketing & General Manager On behalf of : Kanto Distribution Inc. Telephone: 1-778-284-6942

External Photos

Outside view Outside view Outside view Outside view Outside view

ID Label/Location Info

GRANDSTAND SUB LR OPTICALCOAX DIGITAL INANALOG INOUT RCA GAIN Vol -Vol +SOURCEPOWER 20 / 30 / 40 dB RCA Made in China Designed in Canada www.kantospeakers.com

ID Label/Location Info

Label Location

Internal Photos

Inside view Inside view Inside view Inside view

RF Exposure Info

RF Exposure Applicable Standard According to §1.1307(b)(5), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. The Section 4.3.1 and Appendix A of KDB447498 D01 V05 was used as the guidance. Calculation Result (Worse Case): WIFI Mode: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] =2.09/5 * 1.57= 0.66, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. The SAR measurement is not necessary.

Test Report

ISO/IEC17025Accredited Lab. Report No: FCC 1412162 File reference No: 2015-01-10 Applicant: Kanto Distribution Inc Product: Powered Speaker system Model No: Grandstand Trademark: Kanto Test Standards: FCC Part 15.247 and RSS-210 Issue 8 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4, FCC Part 15.247 and RSS-210 Issue 8 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: January 10, 2015 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] ANSI C63.4:2009, Report No: FCC1412162 Page 2 of 89 Date: 2015-01-10 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement˖ The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.:899988. IC-Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration No.: IC 5205A-02. Report No: FCC1412162 Page 3 of 89 Date: 2015-01-10 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration.................................................................................................... 4 1.6 Test Uncertainty.................................................................................................5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Operating Condition..............................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Rob Maudsley(Director of Engineering)
[email protected]1-778-284-6942Fax: 1-778-284-6945

Test Firm

Shenzhen Timeway Testing LaboratoriesJack Chung
[email protected]0755-83448688Fax: 86-755-83442996

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.09 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Kanto Living Inc.

Powered Speaker System - FCC ID QKH-KANTOREN - Kanto Living Inc.
QKH-KANTOREN

Powered Speaker System

Sep 17, 2024

Equipment Class

DTS - Digital Transmission System
Active Loudspeaker System - FCC ID QKH-2YEKN002 - Kanto Living Inc.
QKH-2YEKN002

Active Loudspeaker System

Nov 17, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLUETOOTH SPEAKER - FCC ID QKH-2YEKN001 - Kanto Living Inc.
QKH-2YEKN001

BLUETOOTH SPEAKER

Nov 11, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter