Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCCID:QQ2-GA900 Friday, June 11, 2004 Subject: ANTENNA INFORMATION Antenna Type - MT-262002/C/A Back side Antenna Type - MT-262002/C/A Front side Antenna Type - MT-262001/N/A Back side Antenna Type - MT-262001/N/A - FRONT SIDE Antenna Type – HG-906U Antenna Type – HG-906U Antenna Type - HG-908U Antenna Type - MT-262003/N/V Antenna Type - MT-262003/N/V Antenna Type - MT-262004/N/V
CONFIDENTIALITY REQUEST FOR FCCID:QQ2-GA900 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. WaveIP Ltd. would like the following documents regarding this submission for FCC ID: QQ2-GA900 to be kept confidential. 1. Pages 1 of 3 of document GA900_Radio_Scheme 2. Pages 1 of document GA900_Clock_Tree 3. Pages 1 of document GA900_Power_Tree. 4. Pages 1 to 41 of document GA900_user_guide. The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, Company Name: WaveIP Ltd. Technical Contact: Michael Dayan Phone: 972-4-9937333 ext. 121 Fax: 972-4-9592614 Email: [email protected] Address: 1 Tavor Building P.O.B 335 Yokneam 20692, Israel
Saturday, June 05, 2004 FCCID:QQ2-GA900 Lable ARTWORK LABLE ON TEST ITEMLOCATION OF LABLE LOCATION
FCC ID: QQ2-GA900 Subject: Internal & External pictures for GigAccess 900 FCC ID:QQ2-GA900
FCCID: QQ2-GA900 Subject: Environmental evaluation and Exposure limit according to FCC CFR 47 §15.247(b)(5) and §1.1307, §1.1310 Limit for power density for general population /uncontrolled exposure is 0.604 mW/cm² (for 902MHz). The Power density: P (mW/cm²)= P T /4π R² where P T is the maximal transmitted power, which is equal to the transmitter output power 29.88 dBm plus the maximum antenna gain 14 dBi, the maximum equivalent isotropically radiated power EIRP is: P T = 29.88 dBm + 14dBi = 43.88 dBm = 24.434 W Hence, according to 15.247(b)(4) the maximum transmitted power should be reduced by: Power Correction factor = (maximum antenna gain dBi - 6 dBi ) dB In our case the transmitted power was reduced by: Power Correction factor = 14 dBi - 6 dBi = 8 dB P T1 = P T - Power Correction factor = 29.88 dBm - 8 dB = 21.88 dBm Corrected P T = 21.88 dBm + 14dBi = 35.88 dBm = 3.873 W The minimum safe distance “R” where RF exposure does not exceed FCC permitted limit is 17.5 cm. R=sqrt (P T / 0.604 mW/cm² *4π)= sqrt (3,873/7.58)= 22.6 cm
GigAccess WaveIP EMI Test Report REV ∆ Description Sheet Effected Date Drawn Checked A 09.06.04 D.Lanuel S.Cohen EMC Laboratory Manufactured by WaveIP Ltd. EMC Test Report According FCC Part 15 Requirements JUNE 2004 Function/Title Name Signatur e Date Prepared by Test Engineer D.Lanuel 09.06.04 Checked by Test Engineer D.Lanuel 08.06.04 Approved by EMC Lab. Manager S.Cohen 08.06.04 EMC/30020FC04064 1/89 GigAccess WaveIP EMI Test Report Table of Contents Para Page 1 GENERAL INFORMATION........................................................................................................... 3 2 TEST SUMMARY AND SIGNATURES...........................................................................................4 3 EUT DESCRIPTION.....................................................................................................................5 4 OCCUPIED BANDWIDTH FOR DSSS SYSTEM ACCORDING TO 15.247(A) (2)...........................8 5 MAXIMUM PEAK OUTPUT POWER TEST ACCORDING 15.247(B)(3).......................................10 6 OUT OF BAND CONDUCTED EMISSION TEST ACCORDING T0 15.247(C)...............................13 7 RADIATED EMISSION IN RESTRICTED BANDS TEST ACCORDING 15.247(C), 15.205 AND 15.209...........................................................................................................................................15 8 PEAK POWER SPECTRAL DENSITY OF DSSS ACCORDING 15.247D........................................22 9 UNINTENTIONAL RADIATED EMISSION TEST ACCORDING TO 15.109..................................24 10 CONDUCTED EMISSION TEST ACCORDING TO 15.207.15.107...........................................26 11 PLOTS...................................................................................................................................29 12 PICTURES............................................................................................................................84 13 CORRECTION FACTORS.......................................................................................................87 14 ABBREVIATIONS AND ACRONYMS......................................................................................89 EMC/30020FC04064 2/89 GigAccess WaveIP EMI Test Report 1 GENERAL Information a. Description of equipment under test. Equipment Under Test: GigAccess 900 FCCID QQ2-GA900 Manufacturer: WaveIP. Serial Numbers: 00-50-C2-1C-C3-3D Mode of Operation: TX MODE Operating frequency: 902-928MHZ Year of Manufacture: 2004 b. Applicant Information: Applicant: WaveIP Ltd. Applicant Address TAVOR Building YOKNEAM Telephone: +972-4-9937333 FAX: +972-4-9592614 The testing was observed by: Yoram Singer following applicant's personnel: Yoram Singer c. Test Performance: Date of reception for testing: 10.04.04 Dates of testing 11.04.04-20.04.04 Test Laboratory Location TADIRAN EMC LAB , Hashoftim 26 Holon 58102 ISRAEL Tel: 972-3-5574476 Fax: 972-3- 5575320 Applicable EMC Specification: Federal Communication Commission (FCC), Code of Federal Regulations 47, FCC Docket 89-103,Part 15: Radio Frequency Devices, Sections 15.109, 15.209 & 15.207, 15.205, 15.247. EMC/30020FC04064 3/89 GigAccess WaveIP EMI Test Report 2 Test Summary and Signatures. TADIRAN EMC Laboratory has completed testing of E.U.T in accordance with the requirements of the FCC 15.247 The E.U.T was found to comply with the requirements of the FCC Part 15.247 Regulations given below Test Description Specification Reference Date of Testing Test Report Paragraph Compliance PASS/FAIL Occupied 6db bandwidth 15.247 (a) (2) 16/05/04 4 PASS Max peak output power 15.247 (b) (3) 07/06/04 5 PASS Out of band Conducted emission 15.247 (c) 16/05/04 6 PASS Spurious emission radiated In Restricted band 15.209 15.205(a ,c) 13.05/04- 18.05.04 7 PASS Peak power spectral density 15.247 (d) 16.05.04 8 PASS Unintentional radiated emission 15.109 23.05.04 9 PASS Power leads Conducted emission 15.207, 15.107 13.05.04 10 PASS a. Test performed by: Mr. D. Lanuel Test Engineer b. Test Report prepared by: Mr. D. Lanuel Test Engineer c. Test Report Approved by: Mr. Samuel Cohen EMC Lab. Manager EMC/30020FC04064 4/89 GigAccess WaveIP EMI Test Report 3 EUT Description a. General Model Number(s): GigAccess 900 Brief Description (Purpose of Device): GigAccess TM 900 is WaveIP’s wireless point-to-point and point-to-multipoint broadband communication system. The basic subsystem is composed of a single sector, which consists of an AU (Access Unit) and up to 64 SUs (Subscriber Units). Each sector is a stand-alone communication network operating on a star topology with a gateway to the WAN, which allows two-way communication between the SUs and the WAN via the AU. A Sector may be divided into sub sectors, which are consecutive to the SUs within the sector. GigAccess TM 900 system allows operators that provide IP services using GigAccess TM (at 2.4 GHz band) to extend the reach of their system and provide services to clusters of customers that cannot otherwise be reached due to being obstructed by heavy foliage or other obstacles existing in rural areas. For detailed description see GigAccess TM 900 User Guide. b. General Information: (1) Intended Environment: Outdoor (2) Operating Temperature Range: -20°C - +55°C (3) Physical Dimensions of Unit: 190 x 190 x 30 mm (with 6.5 dBi integrated antenna) Table 1 EUT ports and lines Port type Port descri ption Conne ctor type Quantit y Cable type descript ion Cable length, m Connect ed to GigAccess Data input Ethernet 802.3 RJ45 2 CAT 5 Shielded Up to 100m Indoor Outlet output GigAccess Power input 48V DC RJ45 2 CAT 5 Shielded Up to 100m Indoor Outlet output Indoor Outlet data input Ethernet 802.3 RJ45 1 CAT 5 Shielded Up to 100m Computer NIC Indoor Outlet power input 48V DC DC Jack 1 DC standard 2m AC/DC Unit output AC/DC Unit input 90-264V AC AC Jack 1 AC standard 2m Power Wall Socket Figure 1 EUT test configuration EMC/30020FC04064 5/89 GigAccess WaveIP EMI Test Report AU AC/DC Power Supply Indoor Out…
Text truncated - open the document above for the full version.
GigAccess WaveIP EMI SET-UP PICTURES REV ∆ Description Sheet Effected Date Drawn Checked A 09.06.04 D.Lanuel S.Cohen EMC Laboratory Manufactured by WaveIP Ltd. SET-UP Pictures JUNE 2004 Function/Title Name Signatur e Date Prepared by Test Engineer D.Lanuel 09.06.04 Checked by Test Engineer D.Lanuel 08.06.04 Approved by EMC Lab. Manager S.Cohen 08.06.04 1/6 GigAccess WaveIP EMI SET-UP PICTURES 2/6 GigAccess WaveIP EMI SET-UP PICTURES 3/6 GigAccess WaveIP EMI SET-UP PICTURES 4/6 GigAccess WaveIP EMI SET-UP PICTURES 5/6 GigAccess WaveIP EMI SET-UP PICTURES 6/6
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912 MHz - 918 MHz | 973.00 mW |

Point-to-Point & Point-to-Multipoint broadband wireless bridge
Equipment Class
DTS - Digital Transmission System
Point-to-Point & Point-to-Multipoint broadband wireless bridge
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Point-to-Point & Point-to-Multipoint broadband wireless bridge
Equipment Class
DTS - Digital Transmission System
Outdoor Transmitter Unit
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Indoor Transmitter Unit
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter