Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Notice : (1) For FCC Caution: The changes or modifications not expressly approved by the party responsible for compliance could void the userβs authority to operate the equipment. (2) For Industry Canada "Operation is subjects to the following two conditions:(1)this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device."
Sent: Wednesday, January 22, 2003 9:36 PM To: [email protected] Subject: Fw: Interquartz(Malaysia)Bhd.Representative Office, FCC ID:QS5-02WS2000, AN03T2516 Dear Mike: I have do something for this project : FCC ID:QS5-02WS2000, AN03T2516 , please changed them. Question #1 : I have provide a Confidentiality letter in Extend file. Question #2 : Pls Change ID Label with Extend file. Question #3 : Now changed photos, Before is photos of RX, Sorry Question #4 : We have been change the Description in the test Report. Question #5 : User Manual has changed with new pdf file. ETC , Wen ----- Original Message ----- From: "Mike Kuo" <[email protected]> Sent: Saturday, January 18, 2003 6:52 AM Subject: FW: Interquartz(Malaysia)Bhd.Representative Office, FCC ID:QS5-02WS2000, AN03T2516 > > > -----Original Message----- > From: CERTADM > Sent: Friday, January 17, 2003 2:28 PM > To: '[email protected]' > Subject: Interquartz(Malaysia)Bhd.Representative Office, FCC > ID:QS5-02WS2000, AN03T2516 > > > Notice_content > ------------- > Question #1: Request for confidentiality box is checked on the TCB > application form. However, there is no request for confidentiality letter > was submitted. Please provide it. > > Question #2: FCC ID number listed in the FCC ID label format does not agree > with FCC ID number listed in the TCB application and in the test report. > Please provide revised FCC ID label format with correct ID number. > > Question #3: The EUT in the external does not match with the EUT in the > internal photo. The EUT is the test setup photo does not match with Eut in > the external or internal photos. Please explain and provide information. > > Question #4: Section 6.2 of test report, it describes the EUT is activate > manually which does not agree the product description. Please explain. > > Question #5: User manual does not contain information required under section > 15.21 of FCC rules. Please provide revised user manual. > > Best Regards > > Mike Kuo > The items indicated above must be submitted before processing can continue > on the above referenced application. Failure to provide the requested > information within 60 days of the original e-mail date may result in > application dismissal and forfeiture of the filing fee. Also, please note > that partial responses increase processing time and should not be submitted. > Any questions about the content of this correspondence should be directed to > the e-mail address listed below the name of the sender.
ETC Report No.: ET91S-12-101-01Page A1 of A1 FCC ID: QS5-02WS2000 ANNEX A: EXTERNAL CONSTRUCTION PHOTOS OF EUT 1. Front view of EUT 2. Rear view of EUT
ETC Report No.: ET91S-12-101-01Page B1 of B3 FCC ID: QS5-02WS2000 ANNEX B: INTERNAL CONSTRUCTION PHOTOS OF EUT 1. Inside 1 of EUT 2. Inside 2 of EUT ETC Report No.: ET91S-12-101-01Page B2 of B3 FCC ID: QS5-02WS2000 3. Inside 3 of EUT 4. Inside 4 of EUT ETC Report No.: ET91S-12-101-01Page B3 of B3 FCC ID: QS5-02WS2000 5. Front view of PCB 6. Front view of PCB
FCC ID.: QS5-02WS2000 Rev. No 1.0 FCC Part 15 Subpart C EMI TEST REPORT of E.U.T. : DC PIR Transmitter FCC ID. : QS5-02WS2000 MODEL : WS-2000 Working Frequency : 433.92 MHz for APPLICANT: Interquartz (Malaysia) Bhd. Representative office ADDRESS: 5 th F1, No 16, Lane 130,Ming-Chun Road, Hsin Tien, Taipei Hsien, Taiwan Test Performed by ELECTRONICS TESTING CENTER, TAIWAN NO. 8, LANE 29, WEN-MING RD., LO-SHAN TSUN, KUI-SHAN HSIANG, TAOYUAN HSIEN 333, TAIWAN, R.O.C. Tel: (03) 3276170-3276174 Fax: (03) 3276188 Report Number: ET91S-12-101-01 ETC Report No.:ET91S-12-101-01FCC ID.: QS5-02WS2000 Rev. No 1.0 TEST REPORT CERTIFICATION Applicant: Interquartz (Malaysia) Bhd. Representative office 5 th F1, No 16, Lane 130,Ming-Chun Road, Hsin Tien, Taipei Hsien, Taiwan Manufacturer: IQ Group Sdn. Bhd. 149 Jalan Sultan Azlan Shah, Taman Perindustrian Bayan Lepas, 11900 Pulau Pinang, Malaysia Description of EUT: a) Type of EUT: DC PIR Transmitter b) Model No.: WS-2000 c) Serial No.: ---- d) FCC ID: QS5-02WS2000 e) Working Frequency: 433.92 MHz f) Power Supply: DC 1.5V Battery x 3 Regulation Applied: FCC Rules and Regulations Part 15 Subpart C (2002) I HEREBY CERTIFY THAT; The data shown in this report were made in accordance with the procedures given in ANSI C63.4 and the energy emitted by the device was founded to be within the limits applicable. I assume full responsibility for accuracy and completeness of these data. Note:1.The results of the testing report relate only to the items tested. 2.The testing report shall not be reproduced except in full, without the written approval of ETC. 3.The report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. Issue Date : Dec. 30, 2002 Test Engineer : Approve & Authorized Signer : Win-Po Tsai, Manager, NVLAP Signatory EMC Dept. of ELECTRONICS TESTING CENTER, TAIWAN ETC Report No.:ET91S-12-101-01FCC ID.: QS5-02WS2000 Rev. No 1.0 Table of Contents Page 1. GENERAL INFORMATION............................................................................................................................................................1 1.1 PRODUCT DESCRIPTION...................................................................................................................................................................1 1.2 CHARACTERISTICS OF DEVICE:.......................................................................................................................................................1 1.3 TEST METHODOLOGY......................................................................................................................................................................1 1.4 TEST FACILITY..................................................................................................................................................................................1 2. DEFINITION AND LIMITS..............................................................................................................................................................2 2.1 DEFINITION........................................................................................................................................................................................2 2.2 RESTRICTED BANDS OF OPERATION.............................................................................................................................................2 2.3 LIMITATION.......................................................................................................................................................................................3 2.4 LABELING REQUIREMENT...............................................................................................................................................................4 2.5 USER INFORMATION.........................................................................................................................................................................4 3. RADIATED EMISSION MEASUREMENT....................................................................................................................................5 3.1 APPLICABLE STANDARD.................................................................................................................................................................5 3.2 MEASUREMENT PROCEDURE..........................................................................................................................................................5 3.3 TEST DATA.........................................................................................................................................................................................7 3.4 FIELD STRENGTH CALCULATION..................................................................................................................................................8 3.5 RADIATED TEST EQUIPMENT.........................................................................................................................................................8 3.6 MEASURING INSTRUMENT SETUP.................................................................................................................................................8 3.7 RADIATED MEASUREMENT PHOTOS.............................................................................................................................................9 4. BANDWIDTH OF EMISSION AND DUTY FACTOR..............................................................................................................12 4.1 APPLICABLE STANDARD PLOT GRAPHIC OF BANDWIDTH AND DUTY FACTOR...............................................................12 4.2 TEST EQUIPMENT...........................................................................................................................................................................12 4.3 ACTIVE TIME...........................β¦
Text truncated - open the document above for the full version.
ETC Report No.:ET91S-12-101-01Sheet 1 of 1 Sheets FCC ID.: QS5-02WS2000 3.7 Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

DC Push Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
DC Magnetic Door Push Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
DC Wall Switch Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
AC PIR Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter