Test Setup FCC ID : QU7JPAR External Photo -front External Photo - rear
Test Setup FCC ID : QU7JPAR Internal Photo β 1 Internal Photo - 2 Test Setup FCC ID : QU7JPAR Internal Photo β 3 Internal Photo β 4
β’ The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. β’ This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. β’ For Terms And Conditions of the services, it can be provided upon request. β’ The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2371 0521 Website: www.hk.intertek-etlsemko.com Joyce Park Industrial Ltd. Application For Certification (FCC ID: QU7JPAR) Superheterodyne Receiver 0214479(S1) DL/Sandy May 18, 2004 INTERTEK TESTING SERVICES FCC ID: QU7JPAR i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: QU7JPAR ii MEASUREMENT/TECHNICAL REPORT Joyce Park Industrial Ltd. - MODEL: SE-8100 SE-7100 SE-6100 FCC ID: QU7JPAR May 18, 2004 This report concerns (check one:) Original Grant X Class II Change _____ Equipment Type: Superheterodyne Receiver (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart B for unintentional radiator - the new 47 CFR [12-08-03 Edition] provision. Report prepared by: Derek Leung Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576, Castle Peak Road, Kowloon, Hong Kong. Phone: 852-2173-8504 Fax: 852-2371-0521 INTERTEK TESTING SERVICES FCC ID: QU7JPAR iii Table of Contents 1.0 General Description............................................................................................ 2 1.1 Product Description............................................................................................ 2 1.2 Related Submittal(s) Grants................................................................................ 2 1.3 Test Methodology............................................................................................... 3 1.4 Test Facility........................................................................................................ 3 2.0 System Test Configuration ................................................................................. 5 2.1 Justification ........................................................................................................ 5 2.2 EUT Exercising Software .................................................................................... 5 2.3 Special Accessories ........................................................................................... 5 2.4 Equipment Modification ...................................................................................... 6 2.5 Measurement Uncertainty................................................................................... 6 2.6 Support Equipment List and Description............................................................. 6 3.0 Emission Results ................................................................................................ 8 3.1 Field Strength Calculation................................................................................... 9 3.2 Radiated Emission Configuration Photograph ................................................... 10 3.3 Radiated Emission Data ................................................................................... 11 4.0 Equipment Photographs ................................................................................... 14 5.0 Product Labelling .............................................................................................. 16 6.0 Technical Specifications................................................................................... 18 7.0 Instruction Manual ............................................................................................. 20 8.0 Miscellaneous Information ................................................................................ 22 8.1 Discussion of Pulse Desensitization .................................................................. 23 8.2 Calculation of Average Factor........................................................................... 24 8.3 Emissions Test Procedures.............................................................................. 25 INTERTEK TESTING SERVICES FCC ID: QU7JPAR iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated Emission radiated photos.doc External Photo External Photo external photos.doc Internal Photo Internal Photo internal photos.doc Block Diagram Block Diagram block.pdf Schematics Circuit Diagram circuit.pdf ID Label/Location Label Artwork and Location label.pdf User Manual User Manual manual.pdf INTERTEK TESTING SERVICES FCC ID: QU7JPAR 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: QU7JPAR 2 1.0 General Description 1.1 Product Description The Equipment Under Test (EUT) is a Receiver Part of a Parking Sensor operating at 915MHz. The EUT is powered by 12V d.c. It will install on the dashboard in the interior of a car. When the driver select reverse gear, the EUT will sound a beep. This indicates that the Parking Sensor is working and has been activated. It can receive the signal from the corresponding transmitter. It can receive the signal from up to four remote sensors. Thβ¦
Text truncated - open the document above for the full version.
Test Setup FCC ID : QU7JPAR Radiated -front Radiated - rear 0214479(S1) 0214479(S1)
2/F., Garment Centre, Β· Kowloon Β· Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 915 MHz - 915 MHz | - |

Parking Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter